Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLEXIBILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Land-based wind turbines with flexible rail-transportable blades – Part 1: Conceptual design and aeroservoelastic performance

This work investigates the conceptual design and the aeroservoelastic performance of land-based wind turbines whose blades can be transported on rail via controlled bending. The turbines have a nameplate power of 5 MW and a rotor diameter of 206 m, and they aim to represent the next generation of land-based machines. Three upwind designs and two downwind designs are presented, combining different design goals together with conventional glass and pultruded carbon fiber laminates in the spar caps. One of the five blade designs is segmented and serves as a benchmark to the state of the art in industry. The results show that controlled flexing requires a reduction in the flapwise stiffness of the blades, but it represents a promising pathway for increasing the size of land-based wind turbine rotors. Given the required stiffness, the rotor can be designed either downwind with standard rotor preconing and nacelle uptilt angles or upwind with higher-than-usual angles. A downwind-specific controller is also presented, featuring a cut-out wind speed reduced to 19 m s –1 and a pitch-to-stall shutdown strategy to minimize blade tip deflections toward the tower. The flexible upwind and downwind rotor designs equipped with pultruded carbon fiber spar caps are found to generate the lowest levelized cost of energy, 2.9 % and 1.3 %, respectively, less than the segmented design. The paper concludes with several recommendations for future work in the area of large flexible wind turbine rotors.

17 WIND ENERGY↗

Structure and flexibility of the yeast NuA4 histone acetyltransferase complex

The NuA4 protein complex acetylates histones H4 and H2A to activate both transcription and DNA repair. We report the 3.1-Å resolution cryo-electron microscopy structure of the central hub of NuA4, which flexibly tethers the histone acetyltransferase (HAT) and Trimer Independent of NuA4 involved in Transcription Interactions with Nucleosomes (TINTIN) modules. The hub contains the large Tra1 subunit and a core that includes Swc4, Arp4, Act1, Eaf1, and the C-terminal region of Epl1. Eaf1 stands out as the primary scaffolding factor that interacts with the Tra1, Swc4, and Epl1 subunits and contributes the conserved HSA helix to the Arp module. Using nucleosome-binding assays, we find that the HAT module, which is anchored to the core through Epl1, recognizes H3K4me3 nucleosomes with hyperacetylated H3 tails, while the TINTIN module, anchored to the core via Eaf1, recognizes nucleosomes that have hyperacetylated H2A and H4 tails. Together with the known interaction of Tra1 with site-specific transcription factors, our data suggest a model in which Tra1 recruits NuA4 to specific genomic sites then allowing the flexible HAT and TINTIN modules to select nearby nucleosomes for acetylation.

59 BASIC BIOLOGICAL SCIENCES↗

Options for Resilient and Flexible Power Systems in Select South American Economies

This poster provides highlights from the published report, Options for Resilient and Flexible Power Systems in Select South American Economies, which summarizes opportunities for Argentina, Brazil, Chile, and Colombia to adapt to the new forces buffeting electricity sectors around the globe to ensure reliable, affordable, sustainable, and resilient power systems. Special attention is placed on the potential role for natural gas to help ensure flexible and resilient power.

ENERGY PLANNING, POLICY, AND ECONOMY,NATURAL GAS,P↗

Resilient buildings for fire-adapted landscapes: EE and flexible loads integrated with solar and storage microgrids

Energy efficiency (EE) and flexible loads can be part of a resilient buildings packagewhen they are combined with solar and storage in a clean energy microgrid to reduce the carbonfootprint of buildings and enable resilience to extreme events. Recent large wildfires and an emerging understanding of the fire-adapted landscapes in the American West underscore the urgency of work towards scaling and commercializing these systems. For example, a recent power shutoff in Northern California (October 9-12, 2019) resulted in 738k customers disconnected at the peak of the outage and is emblematic of challenges to come. Our paper reports on insights from a clean energy microgrid deployment pilot that integrates a 50 kWAC PV array, a 109 kW / 174 kWh battery system, switchgear to safely isolate from the regional power system, and communicating controllers for HVAC and refrigeration. The project will be commissioned in May 2020 and is sited at a critical infrastructure site in rural Northern California – in this case a gasoline station with convenience store. Our experience and results shed light on capabilities of integrated microgrids to provide value to customers during blue sky conditions and resilience during black sky days with high fire risk, and what opportunities and barriers exist for scaling these integrated microgrid systems in the near term. We use a simulation model to estimate how EE and flexibility can extend the run time of solar and storage, improving the reliability of power at critical sites.

Alstone, Peter↗

A Flexible Power Method for Solving Infinite Dimensional Tensor Eigenvalue Problems

We propose a flexible power method for computing the leftmost, i.e., algebraically smallest, eigenvalue of an infinite dimensional tensor eigenvalue problem, $H x = \lambda x$, where the infinite dimensional symmetric matrix $H$ exhibits a translational invariant structure. We assume the smallest eigenvalue of $H$ is simple and apply a power iteration of $e^{-H}$ with the eigenvector represented in a compact way as a translational invariant infinite Tensor Ring (iTR). Hence, the infinite dimensional eigenvector can be represented by a finite number of iTR cores of finite rank. In order to implement this power iteration, we use a small parameter $t$ so that the infinite matrix-vector operation $e^{-Ht}x$ can efficiently be approximated by the Lie product formula, also known as Suzuki--Trotter splitting, and we employ a low rank approximation through a truncated singular value decomposition on the iTR cores in order to keep the cost of subsequent power iterations bounded. We also use an efficient way for computing the iTR Rayleigh quotient and introduce a finite size iTR residual which is used to monitor the convergence of the Rayleigh quotient and to modify the timestep $t$. In this paper, we discuss 2 different implementations of the flexible power algorithm and illustrate the automatic timestep adaption approach for several numerical examples.

Beeumen, Roel Van↗

Impact of Thermal Plant Operational Flexibility on VRE Curtailment: The Curtailment Paradox

This presentation provides an overview of a previously published paper in Joule "The curtailment paradox in the transition to high solar power systems." The adoption of PV and battery storage has accelerated globally in recent years, driven by rapid cost declines. A corresponding increase in curtailment is anticipated as PV growth continues. This study explores the effect of system flexibility options on curtailment across increasing PV penetration levels. Results highlight a paradox where thermal generator flexibility matters most only at mid-PV penetration levels (25%-40%), and a misalignment exists where PV provides system value by providing operating reserves without sufficient opportunity for monetary compensation.

capacity expansion modeling↗

Seamlessly Fuel Flexible Heat Pump with Optimal Model-based Control Strategies to Reduce Peak Demand, Utility Cost and CO2 Emission

This research develops a novel hybrid fuel heat pump system for space heating of residential and small commercial buildings with built-in optimization and control. Whereas conventional dual fuel systems either run on gas or electricity at any given moment, the proposed seamlessly fuel flexible heat pump (SFFHP) simultaneously consumes gas and electricity and continuously optimizes the proportion of each. The building air flows across the heat pump condenser first and then flows across the furnace coil, and this reduces the heat pump temperature lift. The SFFHP delivers energy savings by allowing each subsystem (gas furnace and electric heat pump) to operate where it performs best to improve energy efficiency, minimize energy cost, and minimize carbon footprint. The capacities of the electric heat pump and gas furnace are continuously adjusted based on ambient conditions, utility price signals, and marginal grid emission signals. An optimal model predictive control strategy was developed with the goal of minimizing utility cost and minimizing CO2 emission. Two case studies were conducted to simulate the performance of SFFHP during the heating season in Chicago and Los Angeles, respectively. Compared with a conventional electric heat pump, SFFHP yields 33% utility cost reduction and 49% CO2 emission reduction in Chicago. Similarly, it achieves 23% utility cost reduction and 17% CO2 emission reduction in Los Angeles. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. Due to the hybrid fuel nature of this novel equipment, user comfort will always be maintained. The fuel flexibility makes it an attractive option for demand response programs.

Li, Zhenning↗

Hybrid Heat Pump Controls: Conventional Dual Fuel versus Seamlessly Fuel Flexible Heat Pump

This paper compares the performance of a novel seamlessly fuel flexible heat pump (SFFHP) and conventional dual fuel heat pump (DFHP) for space heating. The conventional dual fuel systems either run on the gas furnace or electric heat pump at any given moment, as a comparison, the proposed seamlessly fuel flexible heat pump simultaneously consumes gas and electricity by continuously optimizing the proportion of each. The process air flows across the heat pump condenser first and then flows across the furnace coil, therefore, the heat pump temperature lift is reduced. SFFHP delivers energy savings by allowing each subsystem, i.e., gas furnace and electric heat pump, to operate where it performs best.For DFHP, two operation control strategies, i.e., non-restricted control and restricted control, are available on market. For the non-restricted mode, the thermostat has a switching temperature-programmed according to the balancing point of heating load and capacity curve. Heat pump operates above the switching temperature, while the furnace takes over under the switching temperature. For the restricted control, the compressor of a heat pump is disabled below a predefined lockout outdoor temperature to let the furnace take over. For SFFHP, a model predictive control strategy is developed to continuously adjust the capacities of the electric heat pump and gas furnace based on the foreseen weather data, utility price signals, and marginal grid emission signals with the goal of minimizing the utility cost and CO2 emission while guaranteeing comfort requirements.In this paper, DFHP and SFFHP are simulated using high-fidelity heat pump performance curves generated from DOE/ORNL heat pump design model. Performance comparison of DFHP and SFFHP during 2019-2020 heating season in Los Angeles shows that SFFHP with model predictive control achieves 23% utility cost reduction and 17 % CO2 emission reduction. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. As a result, SFFHP can deliver superior benefits for utility cost reduction and CO2 emission reduction over conventional dual fuel heat pump.

Li, Zhenning↗

Rigid stiffener-reinforced flexible neural probes, and methods of fabrication using wicking channel-distributed adhesives and tissue insertion and extraction

A stiffener-reinforced microelectrode array probe and fabrication method using wicking channel-distributed adhesives which temporarily adheres a flexible device onto a rigid stiffener for insertion and extraction. Assembly is by dispensing a liquid adhesive into a narrow open groove wicking channel formed on the stiffener so that the adhesive is wicked along and fills the channel by capillary action, and adhering the adhesive-filled bonding side of the elongated section of the rigid substrate to a flexible device.

Shah, Kedar G.↗

Transient Efficiency, Flexibility, and Reliability Optimization of Coal-Fired Power Plants - Final Program Review

This program developed an advanced model-based monitoring and model-predictive control algorithms for a coal fired power plant (CFPP), and deployed these algorithms in a real-time platform to demonstrate performance benefits for transient flexibility and plant operation efficiency. More specifically, the objectives were successfully achieved through a combination of (i) developing a high-fidelity transient plant model in Apros, which was used as a high-fidelity plant simulation between $100-50\% TMCR$ where TMCR denotes the turbine maximum continuous rating, i.e., baseload, (ii) developing a very fast physics-based reduced-order model (ROM) of the plant, which ran more than $100\times$ faster than real-time, enabling its use as real-time embedded model for model-based estimation (MBE) and model predictive control (MPC) (iii) implementing a real-time MBE based on ROM using a robust unscented Kalman filter (UKF) to continuously tune the ROM to match the measurements from high-fidelity Apros plant model despite significant plant-model mismatch, and thus, obtain a Digital Twin of the plant (iv) designing and implementing a real-time MPC with dual objectives of transient plant load tracking with high ramp rates and minimizing coal consumption, i.e., improving plant efficiency in the baseload-partload operation range of $100-50\% TMCR$. Each key element above was developed and tested individually, and has been reported in corresponding Topical Reports. Finally, all the individual elements were integrated in an overall closed-loop system, that was successfully tested in desktop Simulink test harness simulations with ROM or high-fidelity model as the plant. Thereafter, the Simulink implementation was used to auto-generate C-code and deploy as real-time Docker microservice containers in Linux, and validate that they can run in real-time in the hardware-in-the loop (HIL) setup and produce the same results as in Simulink. The results of the integrated simulation tests in Simulink as well as the real-time HIL deployment are documented in this final report, showing good load tracking for load ramps at $3-4\%/min$ ramp rates, and achieving up to $5.5\%$ reduction in coal relative to baseline operation at $50\% TMCR$ load. The desktop and HIL simulations show successful performance of the overall model based estimation and control solution and achieve the key objectives of the program for flexible, efficient and reliable operation of sub-critical coal fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

A flexible linear diffusion acceleration to k-eigenvalue neutron transport with SN discontinuous finite element method

In this paper, we derive a flexible linear diffusion acceleration (LDA) for k-eigenvalue neutron transport discretized with discontinuous finite element method (DFEM) and discrete ordinates(SN). This LDA is based on our two pieces of previous works: the flexible non linear diffusion acceleration (NDA) for DFEM-SN and LDA for k-eigenvalue neutron transport using pre-conditioned Jacobian-free Newton-Krylov with self-adjoint angular flux (SAAF), continuous finite element method(CFEM), and SN. We point out the differences between LDA and NDA for DFEM-SN and the difference between DFEM-SN and SAAF-CFEM-SN for LDA. Numerical tests are presented to compare the convergence behaviour of NDA and LDA. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

A hardware-in-the-loop approach for laboratory performance verification of flexible building equipment in a typical commercial building

The overall objective of the project is to develop datasets that measure the holistic load flexibility performance of a suite of commonly-used commercial building HVAC and thermal storage equipment using a hardware-in-the-loop test method. The development of the software side of the hardware-in-the-loop flexible load testbed is summarized in this paper.

Chen, Zhelun↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

Impacts of Renewable Energy and Green Hydrogen Policies on Uttar Pradesh's Power Sector Future: Additional Modeling Scenarios to Explore Hydrogen Flexibility [Slides]

This slide deck is part of a broader program focused on supporting Indian states with long-term power system planning. More information about this program can be found at the National Renewable Energy Laboratory's "Supporting India's States With Renewable Energy Integration" web page at https://www.nrel.gov/international/india-renewable-energy-integration.html. The power sector in Uttar Pradesh, India's most populous state, is poised to transform over the next few decades due to a combination of national and state-level policies impacting both the supply and demand of electricity. The Government of Uttar Pradesh has policies and plans to develop in-state solar PV, pumped storage hydropower, and green hydrogen. Power system policymakers and utilities in Uttar Pradesh are faced with the challenges of planning a system that incorporates increasing amounts of renewable energy and storage resources, meets rising electricity demand due to economic development and green hydrogen production, and satisfies operational and reliability requirements. To support these various objectives, the National Renewable Energy Laboratory (NREL), RMI, and the Uttar Pradesh New and Renewable Energy Development Agency (UPNEDA) evaluated the least-cost pathways for the state's power sector through 2050. NREL developed a capacity expansion model that identifies investment and operational decisions for every year (2024-2050) for all of India, with detailed representation for the state of Uttar Pradesh, which can provide a framework for recurring planning studies. The purpose of this slide deck is to supplement the main study (published in May 2024) with additional modeling scenarios to explore hydrogen flexibility.

08 HYDROGEN↗

Actions to Enable Flexible Nuclear Energy

This fact sheet includes key findings and possible actions identified by the Nuclear Innovation: Clean Energy Future (NICE Future) initiative’s Flexible Nuclear Campaign (FNC).

ENERGY PLANNING, POLICY, AND ECONOMY↗

Hydrogen-Bonding Reinforced Flexible Composite Electrodes for Enhanced Energy Storage

The lack of advanced electrode materials is one of the main factors hindering the development of flexible rechargeable aqueous batteries (RABs) for high specific energy density and structural stability. It is also challenging to achieve high-capacity performance for both the positive and negative electrodes simultaneously. In this work, it is demonstrated that, by smartly designing the composite structures of positive and negative electrodes via one-step electrodeposition strategy, the energy storage performance of the RAB is largely enhanced. For positive electrode material synthesis, Co-Cu double hydroxides (Co-Cu-DH) nanosheets are skillfully rooted into electroreduced graphene oxide (eRG) via hydrogen bonding, in which graphene oxide reduction, Co-Cu-DH nucleation/growth, and formation of hydrogen bonding between Co-Cu-DH and eRG simultaneously occur. Moreover, when a RAB based on Co-Cu-DH@eRG//FeOOH@eRG using the same composite design strategy is established, a wide operating voltage window of ≈1.8 V, a high specific energy density of ≈142.8 Wh kg –1 at ≈890 W kg –1 , and long-term cyclic stability (88.5% of capacity retention after 12 000 cycles) are obtained. This study presents a general compositing strategy for the development of advanced electrode materials, and it is expected to stimulate future material synthesis/design in RABs toward the goal of high energy density storage.

25 ENERGY STORAGE↗