Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW VELOCITY - DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Experimental system for the control of surgically induced infections

The results are presented of the development tests performed on the experimental system for the control of surgically induced infections. Tests were performed on the portable clean room to demonstrate assembly, collapsability, portability and storage. Collapsing, relocating and storing within the surgery room can be accomplished in 12 minutes. The storage envelope dimensions are 1.64 m x 4.24 m x 2.62 m high. The disassembly transfer to another room, and reassembly were demonstrated. The laminar air flow velocity profile within the enclosure was measured. In the undisturbed area of the enclosure the air flow met the Federal Standard 209a requirements of 27.45 meters per minute + or - 6.10 meters per minute. Smoke tests with simulated surgery equipment and personnel in the enclosure did not indicate any detrimental air flow patterns. It is concluded that the system as designed will perform the functions required for its intended use.

Source record↗

Measurements of compressible secondary flow in a circular S-duct

This paper presents the results of an experimental study of secondary flow in a circular cross section 30 deg - 30 deg S-duct with entrance Mach number of 0.6. Local flow velocity vectors have been measured along the length of the duct at six stations. These measurements have been made using a five-port cone probe. Static and total pressure profiles in the transverse planes are obtained from the cone probe measurements. Wall static pressure measurements along three azimuth angles of 0 deg, 90 deg, and 180 deg along the duct are also made. Contour plots presenting the three dimensional velocity field as well as the total- and static-pressure fields are obtained. Surface oil flow visualization technique has been used to provide details of the flow on the S-duct boundaries. The experimental observations have been compared with typical computational results.

Vakili, A.↗

Meridional plasma flow in the outer heliosphere

Voyager 2 observations made in the outer heliosphere near 25 AU and within 2 deg of the heliographic equatorial plane show periodic variations in the meridional (North/South) flow velocities that are much more prominent than the East/West variations. An autocorrelation analysis shows that the flow variation has a period of about 25.5 days in the latter half of 1986, in approximate agreement with the solar rotation period. The results suggest that increased pressure in interaction regions remains the best candidate for the driver of the nonradial flows.

Lazarus, A. J.↗

Aero-thermal Calibration of the NASA Glenn Icing Research Tunnel (2000 Tests)

Aerothermal calibration measurements and flow quality surveys were made in the test section of the Icing Research Tunnel at the NASA Glenn Research Center. These surveys were made following major facility modifications including widening of the heat exchanger tunnel section, replacement of the heat exchanger, installation of new turning vanes, and installation of new fan exit guide vanes. Standard practice at NASA Glenn requires that test section calibration and flow quality surveys be performed following such major facility modifications. A single horizontally oriented rake was used to survey the flow field at several vertical positions within a single cross-sectional plane of the test section. These surveys provided a detailed mapping of the total and static pressure, total temperature, Mach number, velocity, flow angle and turbulence intensity. Data were acquired over the entire velocity and total temperature range of the facility. No icing conditions were tested; however, the effects of air sprayed through the water injecting spray bars were assessed. All data indicate good flow quality. Mach number standard deviations were less than 0.0017, flow angle standard deviations were between 0.3 deg and 0.8 deg, total temperature standard deviations were between 0.5 and 1.8 F for subfreezing conditions, axial turbulence intensities varied between 0.3 and 1.0 percent, and transverse turbulence intensities varied between 0.3 and 1.5 percent. Measurement uncertainties were also quantified.

Gonsalez, Jose C.↗

Measurement of velocity fields in fluid dynamics experiments

A microcomputer-video system was used to measure both spatial and temporal variations of two dimensional fluid flow velocity fields. The system utilizes two methods: the first method is the traditional one in which tracers are introduced into the fluid and their position compared at two closely spaced times; and the second method involves scattering coherent light in the fluid and obtaining motion by analyzing the multiple exposed speckle pattern recorded on photographic film.

Fitzjarrald, D. E.↗

Experimental study of combustion in a turbulent free shear layer formed at a rearward facing step

A premixed propane-air flame is stabilized in a turbulent free shear layer formed at a rearward facing step. The mean and rms averages of the turbulent velocity flow field are determined by LDV for both reacting (equivalence ratio 0.57) and nonreacting flows (Reynolds number 15,000-37,000 based on step height). The effect of combustion is to shift the layer toward the recirculation zone and reduce the flame spread. For reacting flow, the growth rate is unchanged except very near the step. The probability density function of the velocity is bimodial near the origin of the reacting layer and single-peaked but often skewed elsewhere. Large-scale structures dominate the reacting shear layer. Measurements of their passing frequency from LDV are consistent with high-speed Schlieren movies of the reacting layer and indicate that the coalescence rate of the eddies in the shear layer is reduced by combustion.

Pitz, R. W.↗

Plasma regimes in the deep geomagnetic tail - ISEE 3

The spacecraft remained close to or within a previously unexplored part of the distant (60-220 earth radii) geomagnetic tail nearly continuously from January 1 to March 30, 1983. Analysis of the data reveals that all of the plasma regimes identified previously with near-earth measurements (plasma sheet, low-latitude boundary layer, plasma mantle, lobe, and magnetosheath) remain recognizable in the distant tail. These regimes, however, are found to be intermingled in a more chaotic fashion than near the earth. Within the plasma sheet at approximately 200 earth radii, typical flow velocities are about 500 km/s tailward, considerably higher than in the near-earth plasma sheet. Earthward flow within the plasma sheet is observed occasionally, indicating the temporary presence of a neutral line beyond 220 earth radii. Also found are strong bidirectional electron anisotropies throughout much of the distant plasma sheet, boundary layer, and magnetosheath.

Bame, S. J.↗

A Critical Assessment of Protein Crystal Growth in Microgravity

Experiments to grow higher diffraction quality protein crystals in the microgravity environment of an orbiting spacecraft are one of the most frequently flown space experiments. Ground-based research has shown that convective flows occur even about protein crystals growing in the Earth's gravitational field. Further, this research has shown that the resultant flow velocities can cause growth cessation, and probably affect the measured X-ray data quality obtained. How flow deleteriously affects protein crystal growth (PCG) is still not known, and is the subject of ongoing research. Failing a rational method for ameliorating flow effects on Earth, one can, through NASA and other nations space agency sponsored programs, carry out protein crystal growth in the microgravity environment of an orbiting spacecraft. Early first generation PCG hardware was characterized by a very low success rate and a steep design learning curve. Subsequent hardware designs have improved upon their predecessors. Now the crystal grower has a wide variety of hardware configurations and crystal growth protocols to choose from, many of which implement "standard" laboratory protein crystal growth methods. While many of these are first or early second generation hardware the success rate, defined as growing crystals giving data better than has been obtained on Earth, is at least 20% overall and may be considerably higher if one only considers latter experiments. There are a large number of protein crystals grown every year, with hundreds of structures determined. Those crystallized in microgravity represent a small proportion of this total, and there is concern that the costs of the microgravity PCG program(s) do not justify such limited returns. Empirical evidence suggests that optimum crystal growth conditions in microgravity differ from those determined on Earth, further exacerbating the chances of success. Microgravity PCG is probably best suited for "mature" crystallizations, where one has considerable experience with the particular macromolecular system and has reached an apparent limit in diffraction resolution. Under such circumstances the cost of one or two successful flight experiments may more than offset the equivalent cost of several years effort to obtain the same improvement in data quality.

Pusey, Marc↗

Radial Flows in Supergranules

We determine the radial component of the supergranular flow velocity by examining the center-to-limb variation of the Doppler velocity signal. We acquire individual Doppler images obtained with the MDI instrument on the SOHO spacecraft and process them to remove the p-mode oscillation signal, the axisymmetric flows, the convective blueshift signal, and instrumental artifacts. The remaining Doppler signal contains only cellular flow structures. The Doppler signal from the horizontal flows in these cells varies like sin p, where p is the heliocentric angle from disk center. The Doppler signal from radial flows varies like cos p. We fit the center-to-limb variation of the mean squared velocity signal to a straight line in sin(exp 2) rho over the central portion of the disk. The intercept of this line at disk center gives the amplitude of the radial component of the flow. The slope of the line gives the amplitude of the horizontal component. We find that the radial flows for typical supergranules have speeds about 10% that of their associated horizontal flows or about 30 m/s. The ratio of the radial to horizontal flow speed increases from 9% to about 18% as the size of the cells decreases from > 60 Mm to approximately 5 Mm. We use data simulations to check these results and find a ratio that increases from 5% to only about 12% over the same range of cell sizes. These smaller ratios are attributed to an underestimation of the horizontal flow speeds due to the fact that, the transverse component of the horizontal flow is not detected by the Doppler measurements.

Hathaway, D. H.↗

Liquid crystal torons in Poiseuille-like flows

Three-dimensional (3D) simulations of the structure of liquid crystal (LC) torons, topologically protected distortions of the LC director field, under material flows are rare but essential in microfluidic applications. Here, we show that torons adopt a steady-state configuration at low flow velocity before disintegrating at higher velocities, in line with experimental results. Furthermore, we show that under partial slip conditions at the boundaries, the flow induces a reversible elongation of the torons, also consistent with the experimental observations. These results are in contrast with previous simulation results for 2D skyrmions under similar flow conditions, highlighting the need for a 3D description of this LC soliton in relation to its coupling to the material flow. These findings pave the way for future studies of other topological solitons, like hopfions and heliknotons, in flowing soft matter systems.

Science & Technology - Other Topics↗

Shear flow aerodynamics - Lifting surface theory

A lifting surface theory based on a parallel shear flow model is presented for steady, incompressible flows. The theory is intended to account approximately for the presence of a boundary layer. The method of Fourier transforms is used to calculate the pressure on a surface of infinite extent and arbitrary contour. Immediately above the surface is a region of sheared flow (the boundary layer), outside of which the flow velocity is constant. The Fourier transform of the pressure on this surface is used to derive the shear flow equivalent to the kernel function of classical potential flow lifting surface theory. The kernel function provides an integral relation between the upwash at a given point on the surface and the pressure everywhere on the surface. This relation is treated as an integral equation for the pressure, and is solved numerically. Computations are presented for the lift and pitching moment on a flat plate in two-dimensional flow, and for flat, rectangular wings of aspect ratio 1, 2, and 5. As expected, the shear layer decreases the lift curve slope; however, the shear layer (whose thickness is constant along the wing chord) has little effect on the center of pressure.

Ventres, C. S.↗

Asymptotic methods for internal transonic flows

For many internal transonic flows of practical interest, some of the relevant nondimensional parameters typically are small enough that a perturbation scheme can be expected to give a useful level of numerical accuracy. A variety of steady and unsteady transonic channel and cascade flows is studied with the help of systematic perturbation methods which take advantage of this fact. Asymptotic representations are constructed for small changes in channel cross-section area, small flow deflection angles, small differences between the flow velocity and the sound speed, small amplitudes of imposed oscillations, and small reduced frequencies. Inside a channel the flow is nearly one-dimensional except in thin regions immediately downstream of a shock wave, at the channel entrance and exit, and near the channel throat. A study of two-dimensional cascade flow is extended to include a description of three-dimensional compressor-rotor flow which leads to analytical results except in thin edge regions which require numerical solution. For unsteady flow the qualitative nature of the shock-wave motion in a channel depends strongly on the orders of magnitude of the frequency and amplitude of impressed wall oscillations or fluctuations in back pressure. One example of supersonic flow is considered, for a channel with length large compared to its width, including the effect of separation bubbles and the possibility of self-sustained oscillations. The effect of viscosity on a weak shock wave in a channel is discussed.

Adamson, T. C., Jr.↗

Comparison of Two Acoustic Waveguide Methods for Determining Liner Impedance

Acoustic measurements taken in a flow impedance tube are used to assess the relative accuracy of two waveguide methods for impedance eduction in the presence of grazing flow. The aeroacoustic environment is assumed to contain forward and backward-traveling acoustic waves, consisting of multiple modes, and uniform mean flow. Both methods require a measurement of the complex acoustic pressure profile over the length of the test liner. The Single Mode Method assumes that the sound pressure level and phase decay-rates of a single progressive mode can be extracted from this measured complex acoustic pressure profile. No a priori assumptions are made in the Finite Element. Method regarding the modal or reflection content in the measured acoustic pressure profile. The integrity of each method is initially demonstrated by how well their no-flow impedances match those acquired in a normal incidence impedance tube. These tests were conducted using ceramic tubular and conventional perforate liners. Ceramic tubular liners were included because of their impedance insensitivity to mean flow effects. Conversely, the conventional perforate liner was included because its impedance is known to be sensitive to mean flow velocity effects. Excellent comparisons between impedance values educed with the two waveguide methods in the absence of mean flow and the corresponding values educed with the normal incident impedance tube were observed. The two methods are then compared for mean flow Mach numbers up to 0.5, and are shown to give consistent results for both types of test liners. The quality of the results indicates that the Single Mode Method should be used when the measured acoustic pressure profile is clearly dominated by a single progressive mode, and the Finite Element Method should be used for all other cases.

Jones, Michael G.↗

Steady State Sedimentation in a Liquid Fluidized Bed

The velocity fluctuations and the local particle concentration of a particle suspension exhibiting steady state sedimentation in a fluidized bed are determined as a function of height along the particle column. Both the velocity fluctuations and the particle volume fraction are found to strongly depend on height. We account for the stability of the bed by a simple model evoking a flux balance. Velocity fluctuations driving a downward particle flux are compensated by an upward particle flux stemming from an excess flow velocity due to the concentration gradient of the system.

Segre, P. N.↗

Summary of the 5th Propulsion Aerodynamics Workshop Nozzle Test Case: Heated Nozzle Exhaust Passing Over A Film-Cooled Plate

This paper summarizes findings from the fifth AIAA Propulsion Aerodynamics Workshop nozzle test case. The experimental configuration examined by workshop participants was a subsonic nozzle with a square exit blowing a heated exhaust over a film-cooled plate. Computational fluid dynamics solutions were obtained and compared to experimental measurements of flow velocities and temperatures, as well as plate surface temperatures. The heated nozzle operated with a Mach 0.3 exit flow at a static temperature ratio of 2.7. Cooling air blowing ratios of 0, 1, and 2 were considered. Computational meshes for the flow domain were provided for participants. Workshop participants from eight separate organizations represented government, industry, and academia. A variety of flow solutions were obtained: Most of the flow solutions employed a Reynolds-averaged Navier-Stokes (RANS) approach, but scale-resolving simulations were used in some cases, including wall-modeled large-eddy simulation (LES), and a few hybrid RANS-LES approaches. One Lattice-Boltzmann solver was employed. For heat transfer to the test article, many participants used a conjugate heat transfer approach. Effects of mesh sensitivity, flow solution approach, and wall heat transfer approach are considered. In general, a fully three-dimensional conjugate heat transfer approach enabled better prediction of surface temperatures than simpler wall temperature boundary treatments. Also, the scale resolving approaches provided better prediction of static temperatures in the flow immediately above the plate consisting of the hot jet exhaust boundary layer interacting with the cooling film. Comparisons of plate surface friction drag and heat transfer obtained from the computations are also presented.

nozzle↗

Summary of the 5th Propulsion Aerodynamics Workshop Nozzle Test Case: Heated Nozzle Exhaust Passing Over A Film-Cooled Plate

This paper summarizes findings from the fifth AIAA Propulsion Aerodynamics Workshop nozzle test case. The experimental configuration examined by workshop participants was a subsonic nozzle with a square exit blowing a heated exhaust over a film-cooled plate. Computational fluid dynamics solutions were obtained and compared to experimental measurements of flow velocities and temperatures, as well as plate surface temperatures. The heated nozzle operated with a Mach 0.3 exit flow at a static temperature ratio of 2.7. Cooling air blowing ratios of 0, 1, and 2 were considered. Computational meshes for the flow domain were provided for participants. Workshop participants from eight separate organizations represented government, industry, and academia. A variety of flow solutions were obtained: Most of the flow solutions employed a Reynolds-averaged Navier-Stokes (RANS) approach, but scale-resolving simulations were used in some cases, including wall-modeled large-eddy simulation (LES), and a few hybrid RANS-LES approaches. One Lattice-Boltzmann solver was employed. For heat transfer to the test article, many participants used a conjugate heat transfer approach. Effects of mesh sensitivity, flow solution approach, and wall heat transfer approach are considered. In general, a fully three-dimensional conjugate heat transfer approach enabled better prediction of surface temperatures than simpler wall temperature boundary treatments. Also, the scale resolving approaches provided better prediction of static temperatures in the flow immediately above the plate consisting of the hot jet exhaust boundary layer interacting with the cooling film. Comparisons of plate surface friction drag and heat transfer obtained from the computations are also presented.

nozzle↗

Flow Induced Corrosion in 6061-T6 Aluminum Pipes in De-Ionized Water Environments

Flow induced corrosion/erosion of 6061-T6 aluminum in de-ionized (DI) water environments has not been studied widely. Especially, the long-term effects of corrosion/erosion in seemingly benign flow velocity, temperature, and resistivity ranges of 8 ft/s, 85 oF, 3-5 MOhm-cm, respectively. This study concludes that the flow induced corrosion/erosion in the above parameter ranges is minimal. This is detailed by presenting a literature survey, measuring pipe wall samples from a system that has operated in the above parameter range, predict the loss of material in mm/year at the above velocities and at higher temperatures using electric potential values from other experimental studies coupled with wall shear stress simulated using Computational Fluid Dynamic (CFD) analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗