Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Completion Report for Well ER-2-2 Corrective Action Unit 97: Yucca Flat/Climax Mine, Revision 1

Well ER-2-2 was drilled for the U.S. Department of Energy, Nevada National Security Administration Nevada Field Office in support of the Underground Test Area (UGTA) Activity. The well was drilled from January 17 to February 8, 2016, as part of the Corrective Action Investigation Plan (CAIP) for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada Test Site, Nevada. The primary purpose of the well was to collect hydrogeologic data to evaluate uncertainty in the flow and transport conceptual model and its contamination boundary forecasts, and to detect radionuclides in groundwater from the CALABASH (U2av) underground test. Well ER-2-2 was not completed as planned due to borehole stability problems. As completed, the well includes a piezometer (p1) to 582 meters (m) (1,909 feet [ft]) below ground surface (bgs) installed in the Timber Mountain lower vitric-tuff aquifer (TMLVTA) and a 12.25-inch (in.) diameter open borehole to 836 m (2,743 ft) bgs in the Lower tuff confining unit (LTCU). A 13.375-in. diameter carbon-steel casing is installed from the surface to a depth of 607 m (1,990 ft) bgs. Data collected during borehole construction include composite drill cutting samples collected every 3.0 m (10 ft), geophysical logs to a depth of 672.4 m (2,206 ft) bgs, water-quality measurements (including tritium), water-level measurements, and slug test data. The well penetrated 384.05 m (1,260 ft) of Quaternary alluvium, 541.93 m (1,778 ft) of Tertiary Volcanics (Tv) rocks, and 127.71 m (419 ft) of Paleozoic carbonates. The stratigraphy and lithology were generally as expected. However, several of the stratigraphic units were significantly thicker then predicted—principally, the Tunnel formation (Tn), which had been predicted to be 30 m (100 ft) thick; the actual thickness of this unit was 268.22 m (880 ft). Fluid depths were measured in the borehole during drilling as follows: (1) in the piezometer (p1) at 552.15 m (1,811.53 ft) bgs and (2) in the main casing (m1) at 551.69 m (1,810.01 ft) bgs. As expected, field measurements for tritium were above the Safe Drinking Water Act limit (20,000 picocuries per liter) for a portion of the Tertiary volcanic section near the water table. Tritium concentrations were at or near the field detection limit in the Lower carbonate aquifer (LCA) while drilling. During drilling, a sample was collected while circulating in the LCA. The sample was submitted for off-site laboratory analysis. The sample results indicated low but measurable tritium concentrations. All Fluid Management Plan requirements were met during drilling activities.

54 ENVIRONMENTAL SCIENCES↗

Bio-medical flow sensor

A bio-medical flow sensor including a packageable unit of a bottle, tubing and hypodermic needle which can be pre-sterilized and is disposable. The tubing has spaced apart tubular metal segments. The temperature of the metal segments and fluid flow therein is sensed by thermistors and at a downstream location heat is input by a resistor to the metal segment by a control electronics. The fluids flow and the electrical power required for the resisto to maintain a constant temperature differential between the tubular metal segments is a measurable function of fluid flow through the tubing. The differential temperature measurement is made in a control electronics and also can be used to control a flow control valve or pump on the tubing to maintain a constant flow in the tubing and to shut off the tubing when air is present in the tubing.

Winkler, H. E.↗

Towards replacing physical testing of granular materials with a Topology-based Model

In the study of packed granular materials, the performance of a sample (e.g., the detonation of a high-energy explosive) often correlates to measurements of a fluid flowing through it. The “effective surface area,” the surface area accessible to the airflow, is typically measured using a permeametry apparatus that relates the flow conductance to the permeable surface area via the Carman-Kozeny equation. This equation allows calculating the flow rate of a fluid flowing through the granules packed in the sample for a given pressure drop. However, Carman-Kozeny makes inherent assumptions about tunnel shapes and flow paths that may not accurately hold in situations where the particles possess a wide distribution in shapes, sizes, and aspect ratios, as is true with many powdered systems of technological and commercial interest. To address this challenge, we replicate these measurements virtually on micro-CT images of the powdered material, introducing a new Pore Network Model based on the skeleton of the Morse-Smale complex. Pores are identified as basins of the complex, their incidence encodes adjacency, and the conductivity of the capillary between them is computed from the cross-section at their interface. We build and solve a resistive network to compute an approximate laminar fluid flow through the pore structure. Here, we provide two means of estimating flow-permeable surface area: (i) by direct computation of conductivity, and (ii) by identifying dead-ends in the flow coupled with isosurface extraction and the application of the Carman-Kozeny equation, with the aim of establishing consistency over a range of particle shapes, sizes, porosity levels, and void distribution patterns.

36 MATERIALS SCIENCE↗

Prospect of Continuous VLBI Measurement of Earth Rotation in Monitoring Geophysical Fluids

Large-scale mass transports in the geophysical fluids of the Earth system excite Earth's rotational variations in both length-of-day and polar motion. The excitation process is via the conservation of angular momentum. Therefore Earth rotation observations contain information about the integrated angular momentum (consisting of both the mass term and the motion term) of the geophysical fluids, which include atmosphere, hydrosphere, mantle, and the outer and inner cores. Such global information is often important and otherwise unattainable depending on the nature of the mass transport, its magnitude and time scale. The last few years have seen great advances in VLBI measurement of Earth rotation in precision and temporal resolution. These advances have opened new. areas in geophysical fluid studies, such as oceanic tidal angular momentum, atmospheric tides, Earth librations, and rapid atmospheric angular momentum fluctuations. Precision of 10 microseconds in UTI and 200 microarcseconds in polar motion can now be achieved on hourly basis. Building upon this heritage, the multi-network geodetic VLBI project, Continuous Observation of the Rotation of the Earth (CORE), promises to further these studies and to make possible studies on elusive but tell-tale geophysical processes such as oscillatory modes in the core and in the atmosphere. Currently the early phase of CORE is underway. Within a few years into the new mellinnium, the upcoming space gravity missions (such as GRACE) will measure the temporal variations in Earth's gravitational field, thus providing complementary information to that from Earth rotation study for a better understanding of global geophysical fluid processes.

Chao, Benjamin F.↗

Transcapillary fluid responses to lower body negative pressure

The effect of lower body negative pressure (LBNP) on transcapillary fluid balance, with and without saline ingestion, was investigated in normally hydrated human subjects by measuring leg interstitial fluid pressure, leg circumference, plasma volume, and net whole body transcapillary fluid transport during and after supine LBNP in human subjects. The results indicate that prolonged LBNP, especially with saline ingestion, promotes fluid filtration into lower body tissues.

Aratow, Michael↗

Sensor for Direct Measurement of the Boundary Shear Stress in Fluid Flow

The formation of scour patterns at bridge piers is driven by the forces at the boundary of the water flow. In most experimental scour studies, indirect processes have been applied to estimate the shear and normal stress using measured velocity profiles. The estimations are based on theoretical models and associated assumptions. However, the turbulence flow fields and boundary layer in the pier-scour region are very complex. In addition, available turbulence models cannot account accurately for the bed roughness effect. Direct measurement of the boundary shear and normal stress and their fluctuations are attractive alternatives. However, this approach is a challenging one especially for high spatial resolution and high fidelity measurements. The authors designed and fabricated a prototype miniature shear stress sensor including an EDM machined floating plate and a high-resolution laser optical encoder. Tests were performed both in air as well as operation in water with controlled flow. The sensor sensitivity, stability and signal-to-noise level were measured and evaluated. The detailed test results and a discussion of future work will be presented in this paper.

sheer stress↗

Sensor for Direct Measurement of the Boundary Shear Stress in Fluid Flow

The formation of scour patterns at bridge piers is driven by the forces at the boundary of the water flow. In most experimental scour studies, indirect processes have been applied to estimate the shear and normal stress using measured velocity profiles. The estimations are based on theoretical models and associated assumptions. However, the turbulence flow fields and boundary layer in the pier-scour region are very complex. In addition, available turbulence models cannot account accurately for the bed roughness effect. Direct measurement of the boundary shear and normal stress and their fluctuations are attractive alternatives. However, this approach is a challenging one especially for high spatial resolution and high fidelity measurements. The authors designed and fabricated a prototype miniature shear stress sensor including an EDM machined floating plate and a high-resolution laser optical encoder. Tests were performed both in air as well as operation in water with controlled flow. The sensor sensitivity, stability and signal-to-noise level were measured and evaluated. The detailed test results and a discussion of future work will be presented in this paper.

shear stress↗

Experimental Investigation of Hydraulic Fracturing and Stress Sensitivity of Fracture Permeability Under Changing Polyaxial Stress Conditions

Understanding and predicting fracture propagation and subsequent fluid flow characteristics is critical to geoenergy technologies that engineer and/or utilize favorable geological conditions to store or extract fluids from the subsurface. Fracture permeability decreases nonlinearly with increasing normal stress, but the relationship between shear displacement and fracture permeability is less well understood. We utilize the new Geo–Reservoir Experimental Analogue Technology (GREAT cell), which can apply polyaxial stress states and realistic reservoir temperatures and pressures to cylindrical samples and has the unique capability to alter both the magnitude and orientation of the radial stress field by increments of 11.25° during an experiment. We load synthetic analogue materials and real rock samples to stress conditions representative of 500–1,000 m depth, investigate the hydraulic stimulation process, and then conduct flow experiments while changing the fluid pressure and the orientation of the intermediate and minimum principal stresses. High–resolution circumferential strain measurements combined with fluid pressure data indicate fracture propagation can be both stable (no fluid pressure drop) and unstable (fluid pressure drop). The induced fractures exhibit both opening and shear displacements during their creation and/or during fluid flow with changing radial stress states. Flow tests during radial stress field rotation reveal that fracture normal effective stress has first–order control on fracture permeability but increasing fracture offset can lead to elevated permeabilities at maximum shear stress. Here, the results have implications for our conceptual understanding of fracture propagation as well as fluid flow and deformation around fractures.

58 GEOSCIENCES↗

Hydrophobicity of Cryogenic Fluids for Fuel Transfer in Space Applicaitons

Introduction Hydrophobicity is the tendency of a fluid to repel another material or fluid. Hydrophobiciy can be measured through the wetting angle of the fluid on the surface of the other material. The greater the wetting angle, the more hydrophobic the surface is against the fluid. Hydrophobicity properties can be caused by one of two means, either through physical properties or chemical properties [\citenum{NARBUTT2020121}]. Physical hydrophobicity due to the surface of a solid creating surface roughness/patterning, minimizing the contact area between the fluid and the surface. This can be observed throughout nature, such as the surface of lotus leaves or butterfly wings. This physical property can be induced on a variety of surfaces, namely through laser etching, allowing a surface to be finely lineated to imitate these natural surfaces while controlling quantity, depth, and patterns of the etching on the surface [\citenum{10.1063/1.4905616}]. Physical hydrophobicity is therefore dependent on several variables, including the surface that the fluid is on and properties of the fluid itself, such as density and surface tension, both of which are dependent on temperature and/or pressure. Chemical hydrophobicity [\citenum{MadeiraHydrophobocicicici}] is due to the inherent chemical properties of the materials being used. This is most commonly due to the molecular structures changing the polarity of the materials. Depending on a nonpolar material will repel a polar material, proving to be hydrophobic, conversely if the polarity of the materials is the same (polar – polar, nonpolar – nonpolar), they will attract each other. Cryogenics refers to the behavior of materials at very low temperatures (<\ang{-100} C) [\citenum{ZOHURI20181}]. In space applications many things are inherently cryogenic, therefore this is an important field. There has been little research in how hydrophobicity changes at cryogenic temperatures. Cryogenic fluids are commonly used as fuels for spacecraft, therefore, integrating a hydrophobic surface can increase the transfer rate of the fuel. To test this, several experiments were set up to determine the hydrophobic properties of cryogenic fluids, including nitrogen (LN2), argon (LAr), oxygen (LOx), hydrogen (LH2), and methane (CH4), at cryogenic temperatures. Etched Wafer Testing A silicon wafer cut from a crystal of silicon [100] was used to model the potential hydrophobicity of various cryogenic fluids. Silicon [100] references to the crystallographic orientation of the silicon crystals in the wafer. These wafers were then laser etched to create a surface that is more likely to be hydrophobic. To test the hydrophobicity of the wafers at cryogenic temperatures, the temperatures of the wafers must be reduced to the same temperature as the cryogenic fluid being used to prevent rapid boil-off. To achieve this a double-walled vacuum insulated glass chamber was utilized. The chamber is open, with a double-walled glass that can be placed in a vacuum to remove condensation from the outside to allow easier viewing of the experiment. Furthermore, the silicon wafer's temperature must be lowered to the temperature of LN2, as well as maintain the temperature throughout the experiment. To achieve this a piece of 6061 aluminum was used, creating a stand-off for the wafer and it would allow for the insulation of the temperature of the wafers. The container was then filled with LN2 and once the LN2 stabilized the vaporization and the levels of LN2 dropped under the height of the wafer, the wafer was then allowed to air dry. Once the wafer was dry from the LN2, drops of LN2 were placed on the surface of the wafer for observation. During the first trial, the LN2 that was dropped on the surface displayed nonhydrophobic behaviors, spreading out along the surface, with a minimal wetting angle (too small to be measured). This process was repeated for liquid argon. Further testing with other cryogenic liquids will require different testing apparatuses due to being more volatile. Furthermore, several papers [\citenum{voltvolt7}] have suggested that running a voltage can induce a hydrophobic effect throughout a surface, further testing will include a voltage (constant and oscillating) to determine if voltage influences inducing hydrophobicity at cryogenic temperatures. Chemical Testing Coating the interior walls of the fuel tanks and fuel lines can successfully create a hydrophobic surface. The inherent problem is finding a material that can be used to coat the surface, furthermore, at these temperatures, the coating will remain solid, which could pose issues in maintaining the hydrophobic properties. To test this water (polar) is hydrophobic against oils and fats (nonpolar), therefore the same experiment as the etched wafer testing was conducted to determine if the hydrophobic properties will persist as the nonpolar material remains solid and the polar material remains a fluid. The water remained hydrophobic, allowing testing can expand to the cryogenic fluids. However, another hurdle is faced in finding a chemically opposite material to the cryogenic fluids being tested. As many of the cryogenic fluids being tested are diatomic, they are inherently nonpolar, therefore, the material used for the hydrophobic coating must be polar. Polar greases and lubricants are difficult to come by, however, lithium stearate, appears to be a potential candidate for creating a coated hydrophobic surface for cryogenic fluids at cryogenic temperatures.

Cryogenics↗

Quantifying error of lidar and sodar Doppler beam swinging measurements of wind turbine wakes using computational fluid dynamics

Wind-profiling lidars are now regularly used in boundary-layer meteorology and in applications such as wind energy and air quality. Lidar wind profilers exploit the Doppler shift of laser light backscattered from particulates carried by the wind to measure a line-of-sight (LOS) velocity. The Doppler beam swinging (DBS) technique, used by many commercial systems, considers measurements of this LOS velocity in multiple radial directions in order to estimate horizontal and vertical winds. The method relies on the assumption of homogeneous flow across the region sampled by the beams. Using such a system in inhomogeneous flow, such as wind turbine wakes or complex terrain, will result in errors. To quantify the errors expected from such violation of the assumption of horizontal homogeneity, we simulate inhomogeneous flow in the atmospheric boundary layer, notably stably stratified flow past a wind turbine, with a mean wind speed of 6.5 m s -1 at the turbine hub-height of 80 m. This slightly stable case results in 15° of wind direction change across the turbine rotor disk. The resulting flow field is sampled in the same fashion that a lidar samples the atmosphere with the DBS approach, including the lidar range weighting function, enabling quantification of the error in the DBS observations. The observations from the instruments located upwind have small errors, which are ameliorated with time averaging. However, the downwind observations, particularly within the first two rotor diameters downwind from the wind turbine, suffer from errors due to the heterogeneity of the wind turbine wake. Errors in the stream-wise component of the flow approach 30% of the hub-height inflow wind speed close to the rotor disk. Errors in the cross-stream and vertical velocity components are also significant: cross-stream component errors are on the order of 15% of the hub-height inflow wind speed (1.0 m s &minus;1 ) and errors in the vertical velocity measurement exceed the actual vertical velocity. By three rotor diameters downwind, DBS-based assessments of wake wind speed deficits based on the stream-wise velocity can be relied on even within the near wake within 1.0 s -1 (or 15% of the hub-height inflow wind speed), and the cross-stream velocity error is reduced to 8% while vertical velocity estimates are compromised. Furthermore, measurements of inhomogeneous flow such as wind turbine wakes are susceptible to these errors, and interpretations of field observations should account for this uncertainty.

17 WIND ENERGY↗

Axisymmetric flows from fluid injection into a confined porous medium

In this work, we study the axisymmetric flows generated from fluid injection into a horizontal confined porous medium that is originally saturated with another fluid of different density and viscosity. Neglecting the effects of surface tension and fluid mixing, we use the lubrication approximation to obtain a nonlinear advection-diffusion equation that describes the time evolution of the sharp fluid-fluid interface. The flow behaviors are controlled by two dimensionless groups: M , the viscosity ratio of displaced fluid relative to injected fluid, and Γ , which measures the relative importance of buoyancy and fluid injection. For this axisymmetric geometry, the similarity solution involving R 2 /T (where R is the dimensionless radial coordinate and T is the dimensionless time) is an exact solution to the nonlinear governing equation for all times. Four analytical expressions are identified as asymptotic approximations (two of which are new solutions): (i) injection-driven flow with the injected fluid being more viscous than the displaced fluid ( Γ $\ll$ 1 and M < 1) where we identify a self-similar solution that indicates a parabolic interface shape; (ii) injection-driven flow with injected and displaced fluids of equal viscosity ( Γ $\ll$ 1 and M = 1), where we find a self-similar solution that predicts a distinct parabolic interface shape; (iii) injection-driven flow with a less viscous injected fluid ( Γ $\ll$ 1 and M > 1) for which there is a rarefaction wave solution, assuming that the Saffman-Taylor instability does not occur at the reservoir scale; and (iv) buoyancy-driven flow ( Γ $\gg$ 1) for which there is a well-known self-similar solution corresponding to gravity currents in an unconfined porous medium [S. Lyle et al. “Axisymmetric gravity currents in a porous medium,” J. Fluid Mech. 543, 293–302 (2005)]. The various axisymmetric flows are summarized in a Γ - M regime diagram with five distinct dynamic behaviors including the four asymptotic regimes and an intermediate regime. The implications of the regime diagram are discussed using practical engineering projects of geological CO 2 sequestration, enhanced oil recovery, and underground waste disposal.

42 ENGINEERING↗

Study of a Double Bubbler for Material Balance in Liquids (Training Report 2013)

The objective of this project was to determine the potential of a double bubbler to measure density and fluid level of the molten salt contained in an electrorefiner. Such in-situ real-time measurements can provide key information for material balances in the pyroprocessing of the nuclear spent fuel. This theoretical study showed this technique has a lot of promise. Four different experiments were designed and performed. The first three experiments studied the influence of a variety of factors such as depth difference between the two tubes, gas flow rate, the radius of the tubes and determining the best operating conditions. The last experiment purpose was to determine the precision and accuracy of the apparatus during specific conditions. The elected operating conditions for the characterization of the system were a difference of depth of 25 cm and a flow rate of 55 ml/min in each tube. The measured densities were between 1,000 g/l and 1,400g/l and the level between 34cm and 40 cm. The depth difference between the tubes is critical, the larger, the better. The experiments showed that the flow rate should be the same in each tube. The concordances with theoretical predictions were very good. The density precision was very satisfying (spread<0.1%) and the accuracy was about 1%. For the level determination, the precision was also very satisfying (spread<0.1%), but the accuracy was about 3%. However, those two biases could be corrected with calibration curves. In addition to the aqueous systems studied in the present work, future work will focus on examining the behavior of the double bubbler instrumentation in molten salt systems. The two main challenges which were identified in this work are the effect of the temperature and the variation of the superficial tension.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tissue factor pathway inhibitor prevents airway obstruction, respiratory failure and death due to sulfur mustard analog inhalation

Sulfur mustard (SM) inhalation causes airway injury, with enhanced vascular permeability, coagulation, and airway obstruction. The objective of this study was to determine whether recombinant tissue factor pathway inhibitor (TFPI) could inhibit this pathogenic sequence. Methods: Rats were exposed to the SM analog 2-chloroethyl ethyl sulfide (CEES) via nose-only aerosol inhalation. One hour later, TFPI (1.5 mg/kg) in vehicle, or vehicle alone, was instilled into the trachea. Arterial O{sub 2} saturation was monitored using pulse oximetry. Twelve hours after exposure, animals were euthanized and bronchoalveolar lavage fluid (BALF) and plasma were analyzed for prothrombin, thrombin–antithrombin complex (TAT), active plasminogen activator inhibitor-1 (PAI-1) levels, and fluid fibrinolytic capacity. Lung steady-state PAI-1 mRNA was measured by RT-PCR analysis. Airway-capillary leak was estimated by BALF protein and IgM, and by pleural fluid measurement. In additional animals, airway cast formation was assessed by microdissection and immunohistochemical detection of airway fibrin. Results: Airway obstruction in the form of fibrin-containing casts was evident in central conducting airways of rats receiving CEES. TFPI decreased cast formation, and limited severe hypoxemia. Findings of reduced prothrombin consumption, and lower TAT complexes in BALF, demonstrated that TFPI acted to limit thrombin activation in airways. TFPI, however, did not appreciably affect CEES-induced airway protein leak, PAI-1 mRNA induction, or inhibition of the fibrinolytic activity present in airway surface liquid. Conclusions: Intratracheal administration of TFPI limits airway obstruction, improves gas exchange, and prevents mortality in rats with sulfur mustard-analog-induced acute lung injury. - Highlights: • TFPI administration to rats after mustard inhalation reduces airway cast formation. • Inhibition of thrombin activation is the likely mechanism for limiting casts. • Rats given TFPI had improved tissue oxygenation, and mortality was prevented.

60 APPLIED LIFE SCIENCES↗

Functional performance of pyrovalves

Following several flight and ground test failures of spacecraft systems using single-shot, 'normally closed' pyrotechnically actuated valves (pyrovalves), a Government/Industry cooperative program was initiated to assess the functional performance of five qualified designs. The goal of the program was to provide information on functional performance of pyrovalves to allow users the opportunity to improve procurement requirements. Specific objectives included the demonstration of performance test methods, the seating; these gases/particles entered the fluid path of measurement of 'blowby' (the passage of gases from the pyrotechnic energy source around the activating piston into the valve's fluid path), and the quantification of functional margins for each design. Experiments were conducted at NASA's Langley Research Center on several units for each of the five valve designs. The test methods used for this program measured the forces and energies required to actuate the valves, as well as the energies and the pressures (where possible) delivered by the pyrotechnic sources. Functional performance ranged widely among the designs. Blowby cannot be prevented by o-ring seals; metal-to-metal seals were effective. Functional margin was determined by dividing the energy delivered by the pyrotechnic sources in excess to that required to accomplish the function by the energy required for that function. Two of the five designs had inadequate functional margins with the pyrotechnic cartridges evaluated.

Bement, Laurence J.↗

Petrophysical properties of saprolites from the Oak Ridge Integrated Field Research Challenge site, Tennessee

At the Oak Ridge Integrated Field Research Challenge site, near Oak Ridge, Tennessee, the shallow saprolitic aquifer is contaminated by nitric acid, uranium, and metals originating from the former S3 settling ponds. To interpret low-frequency geophysical methods used to image contaminant plumes, we have characterized the petrophysical properties of three representative saprolite core samples. Their hydraulic conductivity ranges from to in agreement with field data. Complex conductivity measurements, in the frequency range of 1 mHz to 45 kHz, were performed with NaCl solutions with electrical conductivities in the range to , a range representative of field conditions. The electrical conductivity data were well reproduced with a simple linear conductivity model between the saprolite conductivity and the pore water conductivity. The conductivity plots were used to estimate the formation factor (the cementation exponent was about ) and the surface conductivity ( ). The magnitude of the surface conductivity depended on the degree of weathering and therefore on the amount of smectite and mixed layer (illite-smectite) clays present in the saprolite. The chargeability of the core samples was in the range of and is strongly dependent on the salinity. We also performed streaming potential measurements with the same pore fluid composition as that used for the complex conductivity measurements. We found an excess of movable electrical charges on the order of 100 to in agreement with previous investigations connecting the movable excess charge density to permeability. The zeta potential was in the range of to independent on the salinity. The electrical measurements were consistent with an average cation exchange capacity in the range of 1.4 to and a specific surface area on the order of 4000 to about 30,000 . Read More: http://library.seg.org/doi/abs/10.1190/geo2012-0176.1

Revil, André↗

PIV Investigations of the Flow Field in the Volute of a Rotary Blood Pump

A full-size acrylic model of a rotary blood pump was developed in order to utilize Particle Image Velocimetry (PIV) to make measurements of the fluid velocities and turbulent stresses throughout the device. The development of an understanding of the hemodynamics within the blood pump is critical to the development and validation of computational models. A blood analog solution, consisting of sodium iodide solution and glycerin, was developed to match physiological kinematic viscosity. The refractive indecies of the fluid, the pump casing and the impeller were matched to facilitate the use of PIV to make velocity measurements. Velocity measurements made in the volute exit/diffuser region are presented for pumps speeds of 3000-3850 rpm. At each speed data were obtained at a physiological pressure of 90 mmHg and at a maximum flow condition. Four hundred data pairs were used for each resultant mean velocity vector value, representing greater than an order of magnitude more data pairs than reported previously in the literature on similar devices and resulting in velocity uncertainty levels of approximately 2.9%.

Sankovic, John M.↗

PIV Investigations of the Flow Field in the Volute of a Rotary Blood Pump

A full-size acrylic model of a rotary blood pump was developed in order to utilize Particle Image Velocimetry (PIV) to make measurements of the fluid velocities and turbulent stresses throughout the device. The development of an understanding of the hemodynamics within the blood pump is critical to the development and validation of computational models. A blood analog solution, consisting of sodium iodide solution and glycerin, was developed to match physiological kinematic viscosity. The refractive indices of the fluid, the pump casing, and the impeller were matched to facilitate the use of PIV to make velocity measurements. Velocity measurements made in the volute exit/diffuser region are presented for pumps speeds of 3000-3850 rpm. At each speed data were obtained at a physiological pressure of 12 kPa and at a maximum flow condition. Four hundred data pairs were used for each resultant mean velocity vector value, representing greater than an order of magnitude more data pairs than reported previously in the literature on similar devices and resulting in velocity uncertainty levels of approximately 22.9%.

Sankovic, John M.↗