Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Aerodynamic testing in cryogenic nitrogen gas - A precursor to testing in superfluid helium

Testing techniques for transonic cryogenic tunnels using nitrogen as the test fluid are presented. The measurement of static aerodynamic coefficients used to determine component efficiency is discussed, focusing on tests of two-dimensional airfoils at transonic Mach numbers. Also, three-dimensional tests of complete configurations and sidewall mounted wings are examined. Consideration is given to time-dependent phenomena, fluid mechanics, nonintrusive laser techniques, the detection of transition and separation, and testing for flutter, buffet, and oscillating airfoil characteristics.

Lawing, Pierce L.↗

New Programs Utilizing Light Scattering and Flow Imaging Techniques for Macromolecular Crystal Growth and Fluid Dynamics Studies

Dr. Phil Segre, a physicist by training, is a recent addition to the Biotech group, SD46, having joined NASA in August of 2000. Over the past two years he has been developing a laboratory for the study of macromolecular and protein crystal growth. The main apparatus for this work is a Dynamic Light Scattering apparatus, DLS, which is capable of making highly precise measurements of size distributions of both protein solutions and protein crystals. With Drs. Chernov and Thomas (USRA), he has begun a collaboration studying the affects of protein impurities on protein crystal growth and subsequent crystal quality. One of the hypotheses behind the differences between Earth and space grown protein crystals is that the absorption of harmful impurities is reduced in space due to the absence of convective flows. Using DLS measurements we are examining crystal growth with varying amounts of impurities and testing whether there is a strong physical basis behind this hypothesis. With Dr. Joe Ng of UAH he has been collaborating on a project to examine the folding/unfolding dynamics of large RNA complexes. A detailed understanding of this process is necessary for the handling of RNA in biotech applications, and the DLS instrument gives details and results beyond that of other instruments. With Prof. Jim McClymer of the University of Maine (summer faculty visitor to NASA in 2001, 2002), we have been studying the crystallization process in model colloidal suspensions whose behavior in some cases can mimic that of much smaller protein solutions. An understanding of the self-assembly of colloids is the first step in the process of engineering novel materials for photonic and light switching applications. Finally, he has begun an investigation into the physics of particle sedimentation. In addition to the DLS instrument he also has an instrument (called PIV) that can measure flow fields of fluids. The applications are to the dynamics of protein crystal motions both on earth and in low-gravity.

Source record↗

Device Stores and Discharges Metered Fluid

Hand-held container accepts measured amount of liquid from pressurized supply. Supply pressure drives spring-loaded piston that stores enough mechanical energy to discharge measured liquid into another container. Original application of container was to rehydrate sterilized pre-packaged food in zerogravity environment of space vehicles. Possible terrestrial applicatios include dispensing of toxic fluids or metering of fluids for household, commercial or laboratory uses.

Hooper, S. L.↗

Heat transfer studies on the liquid droplet radiator

This paper examines radiation transfer in the droplet sheet of a liquid droplet radiator including non-isotropic scattering by the droplets. Non-isotropic scattering becomes significant for small droplets (diameter less than 0.1 mm) and for low emissivity liquids. For droplets with an emittance of 0.1 and for a droplet sheet optical depth or 5, the radiated power varies by about 12 percent, depending on whether scattering is predominantly forward or backward. An experimental measurement of the power emitted by a cylindrical cloud of heated droplets of silicone fluid is also reported. The measured cloud emissivity correlates, within experimental error, with the analytical model.

Mattick, A. T.↗

Splashing Droplets

Current data on droplet breakup is scarce for the sizes and velocities typical of practical applications such as in spray combustion processes and coating processes. While much more representative of practical applications, the small spatial scales and rapid time-scales prevent detailed measurement of the internal fluid dynamics and liquid property gradients produced by impinging upon surfaces. Realized through the extended spatial and temporal scales afforded by a microgravity environment, an improved understanding of drop breakup dynamics is sought to understand and ultimately control the impingement dynamics of droplets upon surfaces in practical situations. The primary objective of this research will be to mark the onset of different 'splashing modes' and to determine their temperature, pressure and angle dependence for impinging droplets representative of practical fluids. In addition, we are modeling the evolution of droplets that do not initially splash but rather undergo a 'fingering' evolution observed on the spreading fluid front and the transformation of these fingers into splashed products. An example of our experimental data is presented below. These images are of Isopar V impacting a mirror-polished surface. They were acquired using a high-speed camera at 1000 frames per second. They show the spreading of a single droplet after impact and ensuing finger instabilities. Normal gravity experimental data such as this will guide low gravity measurements in the 2.2 second drop tower and KC-135 aircraft as available. Presently we are in the process of comparing the experimental data of droplet shape evolution to numerical models, which can also capture the internal fluid dynamics and liquid property gradients such as produced by impingement upon a heated surface. To-date isothermal numerical data has been modeled using direct numerical simulations of representative splashing droplets. The data obtained so far indicates that the present model describes well the droplet wall interactions to a point in time just before splash. Additional information is included in the original extended abstract.

VanderWal, Randall L.↗

Microgravity Effects on Transendothelial Transport

The Endothelial Cell (EC) layer which lines blood vessels from the aorta to the capillaries provides the principal barrier to transport of water and solutes between blood and underlying tissue. Endothelial cells are continuously exposed to the mechanical shearing force (shear stress) and normal force (pressure) imposed by flowing blood on their surface, and they are adapted to this mechanical environment. When the cardiovascular system is exposed to microgravity, the mechanical environmental of endothelial cells is perturbed drastically and the transport properties of EC layers are altered in response. We have shown recently that step changes in shear stress have an acute effect on transport properties of EC layers in a cell culture model, and several recent studies in different vessels of live animals have confirmed the shear-dependent transport properties of the endothelium. We hypothesize that alterations in mechanical forces induced by microgravity and their resultant influence on transendothelial transport of water and solutes are, in large measure, responsible for the characteristic cephalad fluid shift observed in humans experiencing microgravity. To study the effects of altered mechanical forces on transendothelial transport and to test pharmacologic agents as counter measures to microgravity induced fluid shifts we have proposed ground-based studies using well defined cell culture models.

Tarbell, John M.↗

Critical Transport Phenomena in Fluid Helium Under Low Gravity

The feasibility of carrying out measurements of certain critical transport properties of pure fluid under conditions of low gravity was studied. These properties are the thermal conductivity, kappa, the shear viscosity zeta and the diffusive relaxation time tau, which are predicted to diverge (tend to infinity) as the liquid-vapor critical point is approached. However, in this critical region, the Earth's gravity effect becomes very important. As the critical point is approached, the gravity effects increasingly distort the results. The reason for this is that the compressibility of the fluid also diverges and under the influence of gravity causes a vertical density gradient in the fluid, which is significant even when very thin fluid layers (typically 1 mm high) are being used. The result is that the temperature dependence of kappa, zeta, and tau tends to flatten off as T sub c is approached instead of continuing to increase, and therefore the predictions from the renormalization group and mode coupling theories cannot be subjected to a satisfactory test.

Meyer, H.↗

Ice Detector and Deicing Fluid Effectiveness Monitoring System

An ice detector and deicing fluid effectiveness monitoring system for an aircraft is disclosed. The ice detection portion is particularly suited for use in flight to notify the flight crew of an accumulation of ice on an aircraft lifting and control surfaces, or helicopter rotors, whereas the deicing fluid effectiveness monitoring portion is particularly suited for use on the ground to notify the flight crew of the possible loss of the effectiveness of the deicing fluid. The ice detection portion comprises a temperature sensor and a parallel arrangement of electrodes whose coefficient of coupling is indicative of the formation of the ice, as well as the thickness of the formed ice. The fluid effectiveness monitoring portion comprises a temperature sensor and an ionic-conduction cell array that measures the conductivity of the deicing fluid which is indicative of its concentration and, thus, its freezing point. By measuring the temperature and having knowledge of the freezing point of the deicing fluid, the fluid effectiveness monitoring portion predicts when the deicing fluid may lose its effectiveness because its freezing point may correspond to the temperature of the ambient.

Seegmiller, H. Lee B.↗

Chemical environments of submarine hydrothermal systems

Perhaps because black-smoker chimneys make tremendous subjects for magazine covers, the proposal that submarine hydrothermal systems were involved in the origin of life has caused many investigators to focus on the eye-catching hydrothermal vents. In much the same way that tourists rush to watch the spectacular eruptions of Old Faithful geyser with little regard for the hydrology of the Yellowstone basin, attention is focused on the spectacular, high-temperature hydrothermal vents to the near exclusion of the enormous underlying hydrothermal systems. Nevertheless, the magnitude and complexity of geologic structures, heat flow, and hydrologic parameters which characterize the geyser basins at Yellowstone also characterize submarine hydrothermal systems. However, in the submarine systems the scale can be considerably more vast. Like Old Faithful, submarine hydrothermal vents have a spectacular quality, but they are only one fascinating aspect of enormous geologic systems operating at seafloor spreading centers throughout all of the ocean basins. A critical study of the possible role of hydrothermal processes in the origin of life should include the full spectrum of probable environments. The goals of this chapter are to synthesize diverse information about the inorganic geochemistry of submarine hydrothermal systems, assemble a description of the fundamental physical and chemical attributes of these systems, and consider the implications of high-temperature, fluid-driven processes for organic synthesis. Information about submarine hydrothermal systems comes from many directions. Measurements made directly on venting fluids provide useful, but remarkably limited, clues about processes operating at depth. The oceanic crust has been drilled to approximately 2.0 km depth providing many other pieces of information, but drilling technology has not allowed the bore holes and core samples to reach the maximum depths to which aqueous fluids circulate in oceanic crust. Such determinations rely on studies of pieces of deep oceanic crust uplifted by tectonic forces such as along the Southwest Indian Ridge, or more complete sections of oceanic crust called ophiolite sequences which are presently exposed on continents owing to tectonic emplacement. Much of what is thought to happen in submarine hydrothermal systems is inferred from studies of ophiolite sequences, and especially from the better-exposed ophiolites in Oman, Cyprus and North America. The focus of much that follows is on a few general features: pressure, temperature, oxidation states, fluid composition and mineral alteration, because these features will control whether organic synthesis can occur in hydrothermal systems.

Shock, Everett L.↗

Measurements of the performance of an electrohydrodynamic heat pipe

The performance of an electrohydrodynamic heat pipe formed by enclosing three straight axial electrodes with a 1.27 cm O.D. internally threaded stainless steel tube was measured with Freon-11 as working fluid. The condenser and evaporator conductances at low power were comparable to those measured in a conventional capillary driven heat pipe using similar working fluids. The evaporator conductance improved at high power probably due to the onset of nucleate boiling. The maximum heat throughput for this pipe was substantially higher than that of a conventional pipe.

Loehrke, R. I.↗

Material Remodelling and Unconventional Gaits Facilitate Locomotion of a Robophysical Rover Over Granular Terrain

Autonomous robots and vehicles must occasionally recover from locomotion failure in loosely consolidated granular terrain. Recent mobility challenges led NASA Johnson Space Center to develop a prototype robotic lunar rover Resource Prospector 15 (RP15) capable of wheeled, legged, and crawling behavior. To systematically understand performance of such a device, we developed a scaled-down rover robot and studied its locomotion on slopes of dry and wet granular media. Addition of a cyclic legged gait to the robot’s wheel spinning action changes the robot dynamics from that of a wheeled vehicle to a locomotor paddling through frictional fluid. Granular drag force measurements and modified Resistive Force Theory facilitate modeling of such dynamics. A peculiar gait strategy that agitates and cyclically reflows grains under the robot allows it to ‘swim’ up loosely consolidated hills. Whereas substrate disturbance typically hinders locomotion in granular media, the multi-mode design of RP15 and a diversity of possible gaits facilitate formation of self-organized localized frictional fluids that enable effective robust transport.

Siddharth Shrivastava↗

Zero Boil-Off Tank (ZBOT) Experiment

The Zero-Boil-Off Tank (ZBOT) experiment has been developed as a small scale ISS experiment aimed at delineating important fluid flow, heat and mass transport, and phase change phenomena that affect cryogenic storage tank pressurization and pressure control in microgravity. The experiments use a simulant transparent low boiling point fluid (PnP) in a sealed transparent Dewar to study and quantify: (a) fluid flow and thermal stratification during pressurization; (b) mixing, thermal destratification, depressurization, and jet-ullage penetration during pressure control by jet mixing. The experiment will provide valuable microgravity empirical two-phase data associated with the above-mentioned physical phenomena through highly accurate local wall and fluid temperature and pressure measurements, full-field phase-distribution and flow visualization. Moreover, the experiments are performed under tightly controlled and definable heat transfer boundary conditions to provide reliable high-fidelity data and precise input as required for validation verification of state-of-the-art two-phase CFD models developed as part of this research and by other groups in the international scientific and cryogenic fluid management communities.

ISS↗

Viscous pour point of microquantities of fluid lubricants

A method is described involving the measurement of the viscous desolidification (pour) point of wax-free lubricant fluids. This method is especially useful for pour point testing of experimental quantities, since only six to sixteen drops of the oil are required for a single determination (automatically performed in duplicate) with nearly full recovery of the sample. The technique consists of: (1) rapidly freezing a small, predetermined amount of the oil on the side of a small test tube to form a frozen drop of given dimensions; (2) immersing duplicates of the charged and stoppered tubes into a cold bath; and (3) measuring the temperature when the drop front has moved a predetermined distance as the bath warms up.

Gardos, M. N.↗

Cardiovascular Deconditioning and Venous Air Embolism in Simulated Microgravity in the Rat

Astronauts conducting extravehicular activities undergo decompression to a lower ambient pressure, potentially resulting in gas bubble formation within the tissues and venous circulation. Additionally, exposure to microgravity produces fluid shifts within the body leading to cardiovascular deconditioning. A lower incidence of decompression illness in actual spaceflight compared with that in ground-based altitude chamber flights suggests that there is a possible interaction between microgravity exposure and decompression illness. The purpose of this study was to evaluate the cardiovascular and pulmonary effects of simulated hypobaric decompression stress using a tail suspension (head-down tilt) model of microgravity to produce the fluid shifts associated with weightlessness in conscious, chronically instrumented rats. Venous bubble formation resulting from altitude decompression illness was simulated by a 3-h intravenous air infusion. Cardiovascular deconditioning was simulated by 96 h of head-down tilt. Heart rate, mean arterial blood pressure, central venous pressure, left ventricular wall thickening and cardiac output were continuously recorded. Lung studies were performed to evaluate edema formation and compliance measurement. Blood and pleural fluid were examined for changes in white cell counts and protein concentration. Our data demonstrated that in tail-suspended rats subjected to venous air infusions, there was a reduction in pulmonary edema formation and less of a decrease in cardiac output than occurred following venous air infusion alone. Mean arterial blood pressure and myocardial wall thickening fractions were unchanged with either tail-suspension or venous air infusion. Heart rate decreased in both conditions while systemic vascular resistance increased. These differences may be due in part to a change or redistribution of pulmonary blood flow or to a diminished cellular response to the microvascular insult of the venous air embolization.

Robinson, R. R.↗

Numerical Analysis of Film Cooling at High Blowing Ratio

Computational Fluid Dynamics is used in the analysis of a film cooling jet in crossflow. Predictions of film effectiveness are compared with experimental results for a circular jet at blowing ratios ranging from 0.5 to 2.0. Film effectiveness is a surface quantity which alone is insufficient in understanding the source and finding a remedy for shortcomings of the numerical model. Therefore, in addition, comparisons are made to flow field measurements of temperature along the jet centerline. These comparisons show that the CFD model is accurately predicting the extent and trajectory of the film cooling jet; however, there is a lack of agreement in the near-wall region downstream of the film hole. The effects of main stream turbulence conditions, boundary layer thickness, turbulence modeling, and numerical artificial dissipation are evaluated and found to have an insufficient impact in the wake region of separated films (i.e. cannot account for the discrepancy between measured and predicted centerline fluid temperatures). Analyses of low and moderate blowing ratio cases are carried out and results are in good agreement with data.

El-Gabry, Lamyaa↗

Error analysis for reducing noisy wide-gap concentric cylinder rheometric data for nonlinear fluids - Theory and applications

This work discusses the propagation of errors for the recovery of the shear rate from wide-gap concentric cylinder viscometric measurements of non-Newtonian fluids. A least-square regression of stress on angular velocity data to a system of arbitrary functions is used to propagate the errors for the series solution to the viscometric flow developed by Krieger and Elrod (1953) and Pawlowski (1953) ('power-law' approximation) and for the first term of the series developed by Krieger (1968). A numerical experiment shows that, for measurements affected by significant errors, the first term of the Krieger-Elrod-Pawlowski series ('infinite radius' approximation) and the power-law approximation may recover the shear rate with equal accuracy as the full Krieger-Elrod-Pawlowski solution. An experiment on a clay slurry indicates that the clay has a larger yield stress at rest than during shearing, and that, for the range of shear rates investigated, a four-parameter constitutive equation approximates reasonably well its rheology. The error analysis presented is useful for studying the rheology of fluids such as particle suspensions, slurries, foams, and magma.

Borgia, Andrea↗

Optical measurements and tests performed in a low-gravity environment

Shadowgraph and schlieren techniques have been used on board the NASA KC-135 low-gravity simulation aircraft to measure gravity-related fluid flow occurring in various experimental configurations. These configurations included cooled and solidified ammonium chloride and water, electrodeposited cobalt in CoSO4 solution, and immiscible and crystal melt solutions. Hardware tests have also been performed for such critical optical system components as lasers and spatial filters to determine their performance and operation under low-gravity conditions. These test results will be used in the design of the various future Shuttle experiments which will utilize advanced optical measurement techniques. The design and configuration of the optical systems used to make these measurements and tests are presented, and the performance and operation of these systems and their components under low-gravity conditions are discussed. Some preliminary results are included.

Owen, R. B.↗

Calibration, Data Acquisition, and Post Analysis of Turbulent Fluid Flow in a Calibration Jet Using Hot-wire Anemometry

The Turbine Branch concentrates on the following areas: Computational Fluid Dynamics (CFD), and implementing experimental procedures to obtain physical modeling data. Hot-wire Anemometry is a valuable tool for obtaining physical modeling data. Hot-wire Anemometry is likely to remain the principal research tool for most turbulent air/gas flow studies. The Hot-wire anemometer consists of a fine wire heated by electric current. When placed in a fluid stream, the hot-wire loses heat to the fluid by forced convection. In forced convection, energy transfer is due to molecular motion imposed by an extraneous force moving fluid parcels. When the hot-wire is in "equilibrium", the rate of heat input to the wire is equal to the rate of heat loss at the wire ends. The equality between heat input and heat loss is the basis for King s equation, which relates the electrical parameters of the hot-wire to the flow parameters of the fluid. Hot-wire anemometry is based on convective heat transfer from a heated wire element placed in a fluid flow. Any change in the fluid flow condition that affects the heat transfer from the heated element will be detected virtually instantaneously by a constant-temperature Hot-wire anemometry system. The system implemented for this research is the IFA 300. The system is a fully-integrated, thermal anemometer-based system that measures mean and fluctuating velocity components in air, water, and other fluids. It also measures turbulence and makes localized temperature measurements. A constant-temperature anemometer is a bridge and amplifier circuit that controls a tiny wire at constant temperature. As a fluid flow passes over the heated sensor, the amplifier senses the bridge off-balance and adjusts the voltage to the top of the bridge, keeping the bridge in balance. The voltage on top of the bridge can then be related to the velocity of the flow. The bridge voltage is sensitive to temperature as well as velocity and so the built-in thermocouple circuit can be attached to a thermocouple that can measure the fluid temperature. Additional information is included in the original extended abstract.

Moreno, Michelle↗