Search NASA⌕ Search

SEARCH · Search NASA

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Nuclear imaging to diagnose and correct target-driver registration at high-repetition-rate for improved reactor efficiency

Inertial Confinement Fusion produces energy from a burning plasma lasting a fraction of a nanosecond. Power plant designs based on Inertial Fusion Energy (IFE) will need to ignite targets 1-10 times a second, fired as projectiles into a chamber and delivering the driver to the target location. Driver asymmetry is known to impact ICF experiments at gain near unity and remains a candidate for primary yield degradation, and therefore fusion power plant energy output, for high-gain target designs. For a Fusion Power Plant (FPP), continuous and real-time monitoring of target performance provides an opportunity to stabilize or correct the target-driver registration. This requires x-ray and neutron imaging with a large field-of-view, sufficiently high resolution, fast analysis and to subtend a minimal solid angle. We introduce design criteria for such an imaging system that uses a coded aperture and time-gated, lens-coupled scintillators as a viable solution and outline the research steps required to field such a system. Integrating the imaging system into an IFE power plant as part of an active feedback loop could increase average power output by reducing the failure rate due to mis-aligned drivers with respect to the target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-Term Results of a Prospective, Phase II Study of Long-Term Androgen Ablation, Pelvic Radiotherapy, Brachytherapy Boost, and Adjuvant Docetaxel in Patients With High-Risk Prostate Cancer

Purpose: We report the long-term results of a prospective, Phase II study of long-term androgen deprivation (AD), pelvic radiotherapy (EBRT), permanent transperineal prostate brachytherapy boost (PB), and adjuvant docetaxel in patients with high-risk prostate cancer. Methods and Materials: Eligibility included biopsy-proven prostate adenocarcinoma with the following: prostate-specific antigen (PSA) > 20 ng/ml; or Gleason score of 7 and a PSA >10 ng/ml; or any Gleason score of 8 to 10; or stage T2b to T3 irrespective of Gleason score or PSA. Treatment consisted of 45 Gy of pelvic EBRT, followed 1 month later by PB with either iodine-125 or Pd-103. One month after PB, patients received three cycles of docetaxel chemotherapy (35 mg/m{sup 2} per week, Days 1, 8, and 15 every 28 days). All patients received 2 years of AD. Biochemical failure was defined as per the Phoenix definition (PSA nadir + 2). Results: From August 2000 to March 2004, 42 patients were enrolled. The median overall and active follow-ups were 5.6 years (range, 0.9-7.8 years) and 6.3 years (range, 4-7.8 years), respectively. Grade 2 and 3 acute genitourinary (GU) and gastrointestinal (GI) toxicities were 50.0% and 14.2%, respectively, with no Grade 4 toxicities noted. Grade 3 and 4 acute hematologic toxicities were 19% and 2.4%, respectively. Of the patients, 85.7% were able to complete the planned multimodality treatment. The 5- and 7-year actuarial freedom from biochemical failures rates were 89.6% and 86.5%, and corresponding rates for disease-free survival were 76.2% and 70.4%, respectively. The 5- and 7-year actuarial overall survival rates were 83.3% and 80.1%, respectively. The 5- and 7-year actuarial rates of late Grade 2 GI/GU toxicity (no Grade 3-5) was 7.7%. Conclusions: The trimodality approach of using 2 years of AD, external radiation, brachytherapy, and upfront docetaxel in high-risk prostate cancer is well tolerated, produces encouraging long-term results, and should be validated in a multi-institutional setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lessons learned in the hot cell at the transuranic waste processing center - 15336

The hot cell at the Transuranic Waste Processing Center (TWPC) has been in operation for seven years. Its mission is to empty, process, and repackage the contents Remote Handled (RH) concrete waste casks. The sequence of operation for processing the RH casks includes using a remotely operated manipulator (manipulator) to remove the cask contents and deliver them to a work table where operators process the waste into RH-TRU, CH-TRU, LLW drums using Master Slave Manipulators (MSMs). The manipulator is the only piece of equipment that can remove material from the cask and represents a single point failure that can shut down hot cell processing should it fail. During the first six years of operation the project processing goals were constantly in jeopardy due to the high frequency and extent of manipulator failures that forced unplanned down time in the hot cell to facilitate repairs. In 2013 a hot cell maintenance outage was planned and executed to improve the operability and reduce the equipment failure rate. A new remotely operated manipulator, purchased as a spare before the outage, was installed in the hot cell during the outage. Prior to installing the manipulator into the hot cell several major and minor modifications were made to the manipulator to incorporate improvements manipulator reliability and maintainability based upon operating and maintenance lessons learned from the previous years of operation. Additionally a maintenance glovebox was added to the hot cell for servicing the removable manipulator components. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Crew Time for Maintenance and Repair Activities for Lunar Surface Missions

NASA is currently evaluating different methods to predict how much time crewmembers will spend conducting repair and maintenance activities on future space missions. As mission scope and spacecraft architectures change, understanding how crew repair and maintenance timelines are impacted by mission operations and technology changes is vital for future mission planning. Past work has been done using historical International Space Station (ISS) data to accurately predict crew habitation and operation timelines, resulting in the development of NASA’s Exploration Crew Time Model (ECTM). However, understanding crew maintenance and repair requirements has posed a unique challenge due to the complexity of available datasets, the probabilistic nature of sub-system failures, and the impacts of reliability growth on failure rates. This paper presents a methodology to collect and condition empirical repair and maintenance time data from available datasets, to extrapolate from that data to estimate projected maintenance and repair times for a lunar Surface Habitat (SH), and to assess how uncertainty in repair time could impact utilization time on the lunar surface. NASA ISS maintenance and crew time data are logged into two central databases: the Maintenance Data Collection (MDC) and the Operations Planning Timeline Integration System (OPTimIS). Separately, each of these two datasets capture only portions of the complete set of data required to generate an accurate assessment of crew time spent on maintenance activities at a sub-system level. To create a more useful crew time estimate for maintenance timelines, the authors developed a methodology to capture relevant data from each set and combine and utilize that data by linking crew time requirements to specific components. The authors compare the failure logs in the MDC to crew activity logs pulled from OPTimIS and then process the data to estimate required repair time for each failure and repair event. The entire maintenance activity dataset is then categorized based on the class of failed component to ensure a significant sample size for each class and accurate crew time estimates for any components lacking relevant data. This resultant component repair time data can be used in the future to generate Mean Time to Repair (MTTR) estimates and confidence intervals for each class of component based on a probabilistic distribution of documented maintenance events. These improved MTTR values can then be applied to candidate element sub-system architectures, along with component Mean Time Between Failure (MTBF) data to generate distributions for potential required system crew repair time estimates for a given mission. The authors applied these modeling methods to a case study of a crewed mission to the planned SH and produced expected corrective maintenance crew time distributions. The results produced an expected corrective maintenance crew time at over 24 hours per mission, and a maintenance crew time distribution that reflects the importance of planning for sufficient maintenance requirements each mission. Repair time distributions can then be used to develop more accurate crew schedules and to assess potential available utilization time.

Crew Time↗

Positron Emission Tomography for Assessing Local Failure After Stereotactic Body Radiotherapy for Non-Small-Cell Lung Cancer

Purpose: We analyzed whether positron emission tomography (PET)/computed tomography standardized uptake values (SUVs) after stereotactic body radiotherapy (SBRT) could predict local recurrence (LR) in non-small-cell lung cancer (NSCLC). Methods and Materials: This study comprised 128 patients with Stage I (n = 68) or isolated recurrent/secondary parenchymal (n = 60) NSCLC treated with image-guided SBRT to 50 Gy over 4 consecutive days; prior radiotherapy was allowed. PET/computed tomography scans were obtained before therapy and at 1 to 6 months after therapy, as well as subsequently as clinically indicated. Continuous variables were analyzed with Kruskal-Wallis tests and categorical variables with Pearson chi-square or Fisher exact tests. Actuarial local failure rates were calculated with the Kaplan-Meier method. Results: At a median follow-up of 31 months (range, 6-71 months), the actuarial 1-, 2-, and 3-year local control rates were 100%, 98.5%, and 98.5%, respectively, in the Stage I group and 95.8%, 87.6%, and 85.8%, respectively, in the recurrent group. The cumulative rates of regional nodal recurrence and distant metastasis were 8.8% (6 of 68) and 14.7% (10 of 68), respectively, for the Stage I group and 11.7% (7 of 60) and 16.7% (10 of 60), respectively, for the recurrent group. Univariate analysis showed that SUVs obtained 12.1 to 24 months after treatment for the Stage I group (p = 0.007) and 6.1 to 12 months and 12.1 to 24 months after treatment for the recurrent group were associated with LR (p < 0.001 for both). Of the 128 patients, 17 (13.3%) had ipsilateral consolidation after SBRT but no elevated metabolic activity on PET; none had LR. The cutoff maximum SUV of 5 was found to have 100% sensitivity, 91% specificity, a 50% positive predictive value, and a 100% negative predictive value for predicting LR. Conclusions: PET was helpful for distinguishing SBRT-induced consolidation from LR. SUVs obtained more than 6 months after SBRT for NSCLC were associated with local failure. A maximum SUV greater than 5, especially at more than 6 months after SBRT, should prompt biopsy to rule out LR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-AB-202-05: BEST IN PHYSICS (JOINT IMAGING-THERAPY): First Online Ultrasound-Guided MLC Tracking for Real-Time Motion Compensation in Radiotherapy

Purpose: While MLC tracking has been successfully used for motion compensation of moving targets, current real-time target localization methods rely on correlation models with x-ray imaging or implanted electromagnetic transponders rather than direct target visualization. In contrast, ultrasound imaging yields volumetric data in real-time (4D) without ionizing radiation. We report the first results of online 4D ultrasound-guided MLC tracking in a phantom. Methods: A real-time tracking framework was installed on a 4D ultrasound station (Vivid7 dimension, GE) and used to detect a 2mm spherical lead marker inside a water tank. The volumetric frame rate was 21.3Hz (47ms). The marker was rigidly attached to a motion stage programmed to reproduce nine tumor trajectories (five prostate, four lung). The 3D marker position from ultrasound was used for real-time MLC aperture adaption. The tracking system latency was measured and compensated by prediction for lung trajectories. To measure geometric accuracy, anterior and lateral conformal fields with 10cm circular aperture were delivered for each trajectory. The tracking error was measured as the difference between marker position and MLC aperture in continuous portal imaging. For dosimetric evaluation, 358° VMAT fields were delivered to a biplanar diode array dosimeter using the same trajectories. Dose measurements with and without MLC tracking were compared to a static reference dose using a 3%/3 mm γ-test. Results: The tracking system latency was 170ms. The mean root-mean-square tracking error was 1.01mm (0.75mm prostate, 1.33mm lung). Tracking reduced the mean γ-failure rate from 13.9% to 4.6% for prostate and from 21.8% to 0.6% for lung with high-modulation VMAT plans and from 5% (prostate) and 18% (lung) to 0% with low modulation. Conclusion: Real-time ultrasound tracking was successfully integrated with MLC tracking for the first time and showed similar accuracy and latency as other methods while holding the potential to measure target motion non-invasively. SI was supported by the Graduate School for Computing in Medicine and Life Science, German Excellence Initiative [grant DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

Failure time distributions for complex equipment

The exponential distribution is inadequate as a failure time model for most components; however, under certain conditions (in particular, that component failure rates are small and mutually independent, and failed components are immediately replaced or perfectly repaired), it is applicable to complex repairable systems with large numbers of components in series, regardless of component distributions, as shown by Drenick in 1960. This result implies that system behavior may become simpler as more components are added. We review necessary conditions for the result and present some simulation studies to assess how well it holds in systems with finite numbers of components. Lastly, we also note that Drenick's result is analogous to similar results in other systems disciplines, again resulting in simpler behavior as the number of entities in the system increases.

42 ENGINEERING↗

Integration of Real-Time Internal Electromagnetic Position Monitoring Coupled With Dynamic Multileaf Collimator Tracking: An Intensity-Modulated Radiation Therapy Feasibility Study

Purpose: Continuous tumor position measurement coupled with a tumor tracking system would result in a highly accurate radiation therapy system. Previous internal position monitoring systems have been limited by fluoroscopic radiation dose and low delivery efficiency. We aimed to incorporate a continuous, electromagnetic, three-dimensional position tracking system (Calypso 4D Localization System) with a dynamic multileaf collimator (DMLC)-based dose delivery system. Methods and Materials: A research version of the Calypso System provided real-time position of three Beacon transponders. These real-time three-dimensional positions were sent to research MLC controller with a motion-tracking algorithm that changed the planned leaf sequence. Electromagnetic transponders were embedded in a solid water film phantom that moved with patient lung trajectories while being irradiated with two different plans: a step-and-shoot intensity-modulated radiation therapy (S-IMRT) field and a dynamic IMRT (D-IMRT) field. Dosimetric results were recorded under three conditions: no intervention, DMLC tracking, and a spatial gating system. Results: Dosimetric accuracy was comparable for gating and DMLC tracking. Failure rates for gating/DMLC tracking are as follows: {+-}3 cGy 10.9/ 7.5% for S-IMRT, 3.3/7.2% for D-IMRT; gamma (3mm/3%) 0.2/1.2% for S-IMRT, 0.2/0.2% for D-IMRT. DMLC tracking proved to be as efficient as standard delivery, with a two- to fivefold efficiency increase over gating. Conclusions: Real-time target position information was successfully integrated into a DMLC effector system to modify dose delivery. Experimental results show both comparable dosimetric accuracy as well as improved efficiency compared with spatial gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cable Diagnostic Focused Initiative

This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online knowledge based system (KBS) that helps utilities select the most effective diagnostic technologies for a given cable circuit and circuit conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generic and ML Workloads in an HPC Datacenter: Node Energy, Job Failures, and Node-Job Analysis

HPC datacenters offer a backbone to the modern digital society. Increasingly, they run Machine Learning (ML) jobs next to generic, compute-intensive workloads, supporting science, business, and other decision-making processes. However, understanding how ML jobs impact the operation of HPC datacenters, relative to generic jobs, remains desirable but understudied. In this work, we leverage long-term operational data, collected from a national-scale production HPC datacenter, and statistically compare how ML and generic jobs can impact the performance, failures, resource utilization, and energy consumption of HPC datacenters. Our study provides key insights, e.g., ML-related power usage causes GPU nodes to run into temperature limitations, median/mean runtime and failure rates are higher for ML jobs than for generic jobs, both ML and generic jobs exhibit highly variable arrival processes and resource demands, significant amounts of energy are spent on unsuccessfully terminating jobs, and concurrent jobs tend to terminate in the same state. We open-source our cleaned-up data traces on Zenodo (https://doi. org/10.5281/zenodo.13685426), and provide our analysis toolkit as software hosted on GitHub (https://github.com/atlarge-research/2024-icpads-hpc-workload-characterization). This study offers multiple benefits for data center administrators, who can improve operational efficiency, and for researchers, who can further improve system designs, scheduling techniques, etc.

crossanalysis↗

Two-sided estimates of minimum-error distinguishability of mixed quantum states via generalized Holevo-Curlander bounds

We prove a concise factor-of-2 estimate for the failure rate of optimally distinguishing an arbitrary ensemble of mixed quantum states, generalizing work of Holevo [Theor. Probab. Appl. 23, 411 (1978)] and Curlander [Ph.D. Thesis, MIT, 1979]. A modification to the minimal principle of Cocha and Poor [Proceedings of the 6th International Conference on Quantum Communication, Measurement, and Computing (Rinton, Princeton, NJ, 2003)] is used to derive a suboptimal measurement which has an error rate within a factor of 2 of the optimal by construction. This measurement is quadratically weighted and has appeared as the first iterate of a sequence of measurements proposed by Jezek et al. [Phys. Rev. A 65, 060301 (2002)]. Unlike the so-called pretty good measurement, it coincides with Holevo's asymptotically optimal measurement in the case of nonequiprobable pure states. A quadratically weighted version of the measurement bound by Barnum and Knill [J. Math. Phys. 43, 2097 (2002)] is proven. Bounds on the distinguishability of syndromes in the sense of Schumacher and Westmoreland [Phys. Rev. A 56, 131 (1997)] appear as a corollary. An appendix relates our bounds to the trace-Jensen inequality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-BRD-04: The Impact of Automatic Radiation Therapy Plan Checks in Treatment Planning

Purpose: The physics plan check verifies various aspects of a treatment plan after dosimetrists have finished creating the plan. Some errors in the plan which are caught by the physics check could be caught earlier in the departmental workflow. The purpose of this project was to evaluate a plan checking script that can be run within the treatment planning system (TPS) by the dosimetrists prior to plan approval and export to the record and verify system. Methods: A script was created in the Pinnacle TPS to automatically check 15 aspects of a plan for clinical practice conformity. The script outputs a list of checks which the plan has passed and a list of checks which the plan has failed so that appropriate adjustments can be made. For this study, the script was run on a total of 108 plans: IMRT (46/108), VMAT (35/108) and SBRT (27/108). Results: Of the plans checked by the script, 77/108 (71%) failed at least one of the fifteen checks. IMRT plans resulted in more failed checks (91%) than VMAT (51%) or SBRT (63%), due to the high failure rate of an IMRT-specific check, which checks that no IMRT segment < 5 MU. The dose grid size and couch removal checks caught errors in 10% and 14% of all plans – errors that ultimately may have resulted in harm to the patient. Conclusion: Approximately three-fourths of the plans being examined contain errors that could be caught by dosimetrists running an automated script embedded in the TPS. The results of this study will improve the departmental workflow by cutting down on the number of plans that, due to these types of errors, necessitate re-planning and re-approval of plans, increase dosimetrist and physician workload and, in urgent cases, inconvenience patients by causing treatment delays.

60 APPLIED LIFE SCIENCES↗

Chemoradiation With Concomitant Boosts Followed by Radical Surgery in Locally Advanced Cervical Cancer: Long-term Results of the ROMA-2 Prospective Phase 2 Study

Purpose: This prospective, phase 2 study aimed at assessing the efficacy of accelerated fractionation radiation therapy by concomitant boosts (CBs) associated with chemoradiation therapy (CRT) of the whole pelvis, in improving the rate of pathological complete response (pCR) to treatment in patients with International Federation of Gynaecology and Obstetrics (FIGO) stage IB2-IVA locally advanced cervical cancer. Methods and Materials: Neoadjuvant CRT included conformal irradiation of the whole pelvis with a total dose of 39.6 Gy (1.8 cGy/fraction, 22 fractions), plus additional irradiation of primary tumor and parametria with 10.8 Gy administered with CBs (0.9 cGy/fraction, 12 fractions, every other day). Concomitant chemotherapy included cisplatin (20 mg/m{sup 2}, days 1-4 and 26-30 of treatment), and capecitabine (1300 mg/m{sup 2}/daily, orally) during the first 2 and the last 2 weeks of treatment. Radical hysterectomy plus pelvic with or without aortic lymphadenectomy was performed within 6 to 8 weeks from CRT. Toxicity was recorded according to Radiation Therapy Oncology Group toxicity criteria and Chassagne grading system. Based on the Simon design, 103 cases were required, and the regimen would be considered active if >45 pCR were registered (α error = 0.05; β error = 0.1). Results: pCR was documented in 51 cases (50.5%), and the regimen was considered active, according to the planned statistical assumptions. At median follow-up of 36 months (range: 7-85 months), the 3-year local failure rate was 7%, whereas the 3-year disease-free and overall survival rates were 73.0% and 86.1%, respectively. Grade 3 leukopenia and neutropenia were reported in only 1 and 2 cases, respectively. Gastrointestinal toxicity was always grade 1 or 2. Conclusions: Addition of CBs in the accelerated fractionation modality to the whole pelvis chemoradiation followed by radical surgery results in a high rate of pathologically assessed complete response to CRT and a very encouraging local control rate, with acceptable toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Size of metallic and polyethylene debris particles in failed cemented total hip replacements

Reports of differing failure rates of total hip prostheses made of various metals prompted us to measure the size of metallic and polyethylene particulate debris around failed cemented arthroplasties. We used an isolation method, in which metallic debris was extracted from the tissues, and a non-isolation method of routine preparation for light and electron microscopy. Specimens were taken from 30 cases in which the femoral component was of titanium alloy (10), cobalt-chrome alloy (10), or stainless steel (10). The mean size of metallic particles with the isolation method was 0.8 to 1.0 microns by 1.5 to 1.8 microns. The non-isolation method gave a significantly smaller mean size of 0.3 to 0.4 microns by 0.6 to 0.7 microns. For each technique the particle sizes of the three metals were similar. The mean size of polyethylene particles was 2 to 4 microns by 8 to 13 microns. They were larger in tissue retrieved from failed titanium-alloy implants than from cobalt-chrome and stainless-steel implants. Our results suggest that factors other than the size of the metal particles, such as the constituents of the alloy, and the amount and speed of generation of debris, may be more important in the failure of hip replacements.

Non-NASA Center↗

Conceptual design of thorium-fuelled Mitrailleuse accelerator-driven subcritical reactor using D-Be neutron source

A distributed accelerator is a charged-particle accelerator that uses a new acceleration method based on repeated electrostatic acceleration. This method offers outstanding benefits not possible with the conventional radio-frequency acceleration method, including: (1) high acceleration efficiency, (2) large acceleration current, and (3) lower failure rate made possible by a fully solid-state acceleration field generation circuit. A 'Mitrailleuse Accelerator' is a product we have conceived to optimize this distributed accelerator technology for use with a high-strength neutron source. We have completed the conceptual design of a Mitrailleuse Accelerator and of a thorium-fuelled subcritical reactor driven by a Mitrailleuse Accelerator. This paper presents the conceptual design details and approach to implementing the subcritical reactor core. We will spend the next year or so on detailed design work, and then will start work on developing a prototype for demonstration. If there are no obstacles in setting up a development organization, we expect to finish verifying the prototype's performance by the third quarter of 2015. (authors)

43 PARTICLE ACCELERATORS↗

Does Hormone Therapy Reduce Disease Recurrence in Prostate Cancer Patients Receiving Dose-Escalated Radiation Therapy? An Analysis of Radiation Therapy Oncology Group 94-06

Purpose: The purpose of this study was to evaluate the effect on freedom from biochemical failure (bNED) or disease-free survival (DFS) by adding hormone therapy (HT) to dose-escalated radiation therapy (HDRT). Methods and Materials: We used 883 analyzable prostate cancer patients who enrolled on Radiation Therapy Oncology Group (RTOG) 94-06, a Phase I/II dose escalation trial, and whose mean planning target volume dose exceeded 73.8 Gy (mean, 78.5 Gy; maximum, 84.3 Gy). We defined biochemical failure according to the Phoenix definition. Results: A total of 259 men started HT 2 to 3 months before HDRT, but not longer than 6 months, and 66 men with high-risk prostate cancer received HT for a longer duration. At 5 years, the biochemical failure rates after HDRT alone were 12%, 18%, and 29% for low-, intermediate-, and high-risk patients, respectively (p < 0.0001). Cox proportional hazards regression analysis adjusted for covariates revealed that pretreatment PSA level was a significant factor, whereas risk group, Gleason score, T-stage, and age were not. When the patients were stratified by risk groups, the Cox proportion hazards regression model (after adjusting for pretreatment PSA, biopsy Gleason score, and T stage) did not reveal a significant effect on bNED or DFS by adding HT to HDRT Conclusion: The addition of HT did not significantly improve bNED survival or DFS in all prostate cancer patients receiving HDRT, but did approach significance in high-risk patient subgroup. The result of this study is hypothesis generating and requires testing in a prospective randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An accurate online calibration system based on combined clamp-shape coil for high voltage electronic current transformers

Electronic transformers are widely used in power systems because of their wide bandwidth and good transient performance. However, as an emerging technology, the failure rate of electronic transformers is higher than that of traditional transformers. As a result, the calibration period needs to be shortened. Traditional calibration methods require the power of transmission line be cut off, which results in complicated operation and power off loss. This paper proposes an online calibration system which can calibrate electronic current transformers without power off. In this work, the high accuracy standard current transformer and online operation method are the key techniques. Based on the clamp-shape iron-core coil and clamp-shape air-core coil, a combined clamp-shape coil is designed as the standard current transformer. By analyzing the output characteristics of the two coils, the combined clamp-shape coil can achieve verification of the accuracy. So the accuracy of the online calibration system can be guaranteed. Moreover, by employing the earth potential working method and using two insulating rods to connect the combined clamp-shape coil to the high voltage bus, the operation becomes simple and safe. Tests in China National Center for High Voltage Measurement and field experiments show that the proposed system has a high accuracy of up to 0.05 class.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predictors of Local Recurrence After Rituximab-Based Chemotherapy Alone in Stage III and IV Diffuse Large B-Cell Lymphoma: Guiding Decisions for Consolidative Radiation

Purpose: The role of consolidative radiation therapy (RT) for stage III and IV diffuse large B-cell lymphoma (DLBCL) in the era of rituximab is not well defined. There is evidence that some patients with bulky disease may benefit, but patient selection criteria are not well established. We sought to identify a subset of patients who experienced a high local failure rate after receiving rituximab-based chemotherapy alone and hence may benefit from the addition of consolidative RT. Methods and Materials: Two hundred eleven patients with stage III and IV DLBCL treated between August 1999 and January 2012 were reviewed. Of these, 89 had a complete response to systemic therapy including rituximab and received no initial RT. Kaplan-Meier analysis and Cox proportional hazards regression were performed, with local recurrence (LR) as the primary outcome. Results: The median follow-up time was 43.9 months. Fifty percent of patients experienced LR at 5 years. In multivariate analysis, tumor ≥5 cm and stage III disease were associated with increased risk of LR. The 5-year LR-free survival was 47.4% for patients with ≥5-cm lesions versus 74.7% for patients with <5-cm lesions (P=.01). In patients with <5-cm tumors, the maximum standardized uptake value (SUVmax) was ≥15 in all patients with LR. The 5-year LR-free survival was 100% in SUV<15 versus 68.8% in SUV≥15 (P=.10). Conclusions: Advanced-stage DLBCL patients with stage III disease or with disease ≥5 cm appear to be at an increased risk for LR. Patients with <5-cm disease and SUVmax ≥15 may be at higher risk for LR. These patients may benefit from consolidative RT after chemoimmunotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗