Tracking and data handling for the pioneer iii and pioneer iv firings
Tracking and data handling systems for Pioneer III space probe and Pioneer IV lunar probe firings
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Tracking and data handling systems for Pioneer III space probe and Pioneer IV lunar probe firings
This paper describes the Expert System for Operations Distributed Users (EXODUS), a knowledge-based artificial intelligence system developed for the four Firing Rooms at the Kennedy Space Center. EXODUS is used by the Shuttle engineers and test conductors to monitor and control the sequence of tasks required for processing and launching Shuttle vehicles. In this paper, attention is given to the goals and the design of EXODUS, the operational requirements, and the extensibility of the technology.
The USGS and NASA, in conjunction with Colorado State University, George Mason University and other partners, have developed the Invasive Species Forecasting System (ISFS), a flexible tool that capitalizes on NASA's remote sensing resource to produce dynamic habitat maps of invasive terrestrial plant species across the United States. In 2006 ISFS was adopted to generate predictive invasive habitat maps to benefit noxious plant and fire management teams in three major National Park systems: The Greater Yellowstone Area (Yellowstone / Grand Tetons National Parks), Sequoia and Kings Canyon National Park, and interior Alaskan (between Denali, Gates of The Arctic and Yukon-Charley). One of the objectives of this study is to explore how the ISFS enhances decision support apparatus in use by National Park management teams. The first step with each park system was to work closely with park managers to select top-priority invasive species. Specific species were chosen for each study area based on management priorities, availability of observational data, and their potential for invasion after fire disturbances. Once focal species were selected, sources of presence/absence data were collected from previous surveys for each species in and around the Parks. Using logistic regression to couple presence/absence points with environmental data layers, the first round of ISFS habitat suitability maps were generated for each National Park system and presented during park visits over the summer of 2006. This first engagement provided a demonstration of what the park service can expect from ISFS and initiated the ongoing dialog on how the parks can best utilized the system to enhance their decisions related to invasive species control. During the park visits it was discovered that separate "expert opinion" maps would provide a valuable baseline to compare against the ISFS model output. Opinion maps are a means of spatially representing qualitative knowledge into a quantitative two-dimensional map. Furthermore, our approach combines the qualitative expert opinion habitat maps -- with the quantitative ISFS habitat maps in a difference map that shows where the two maps agree and disagree. The objective of the difference map is to help focus future field sampling and improve model results. This paper presents a demonstration of the habitat, expert opinion, and difference map for Yellowstone National Park.
The MODIS sensor, launched on NASA's Terra satellite at the end of 1999, was designed with 36 spectral channels for a wide array of land, ocean, and atmospheric investigations. MODIS has a unique ability to observe fires, smoke, and burn scars globally. Its main fire detection channels saturate at high brightness temperatures: 500 K at 4 microns and 400 K at 11 microns, which can only be attained in rare circumstances at the I kin fire detection spatial resolution. Thus, unlike other polar orbiting satellite sensors with similar thermal and spatial resolutions, but much lower saturation temperatures (e.g. AVHRR and ATSR), MODIS can distinguish between low intensity ground surface fires and high intensity crown forest fires. Smoke column concentration over land is for the first time being derived from the MOMS solar channels, extending from 0.41 microns to 2.1 microns. The smoke product has been provisionally validated both globally and regionally over southern Africa and central and south America. Burn scars are observed from MODIS even in the presence of smoke, using the 1.2 to 2.1 micron channels. MODIS burned area information is used to estimate pyrogenic emissions. A wide range of these fire and related products and validation are demonstrated for the wild fires that occurred in northwestern United States in the summer of 2000. The MODIS rapid response system and direct broadcast capability is being developed to enable users to obtain and generate data in near real time. It is expected that health and land management organizations will use these systems for monitoring the occurrence of fires and the dispersion of smoke within two to six hours after data acquisition.
Abstract Wildfires represent major ecological disturbances, burning 2–3% of Earth’s terrestrial area each year with sometimes drastic effects above- and belowground. Soil bacteria offer an ideal, yet understudied system within which to explore fundamental principles of fire ecology. To understand how wildfires restructure soil bacterial communities and alter their functioning, we sought to translate aboveground fire ecology to belowground systems by determining which microbial traits are important post-fire and whether changes in bacterial communities affect carbon cycling. We employed an uncommon approach to assigning bacterial traits, by first running three laboratory experiments to directly determine which microbes survive fires, grow quickly post-fire and/or thrive in the post-fire environment, while tracking CO 2 emissions. We then quantified the abundance of taxa assigned to each trait in a large field dataset of soils one and five years after wildfires in the boreal forest of northern Canada. We found that fast-growing bacteria rapidly dominate post-fire soils but return to pre-burn relative abundances by five years post-fire. Although both fire survival and affinity for the post-fire environment were statistically significant predictors of post-fire community composition, neither are particularly influential. Our results from the incubation trials indicate that soil carbon fluxes post-wildfire are not likely limited by microbial communities, suggesting strong functional resilience. From these findings, we offer a traits-based framework of bacterial responses to wildfire.
In the current design, the Space Station first-flight configuration will be assembled in a LEO and reboosted to a higher altitude such that the orbital decay due to atmospheric drag forces will lower the spacecraft to the proper altitude at the appropriate time to rendezvous with the next-assembly flight of the orbiter. The reboost maneuver will be performed by firing the on/off reaction control system jets to increase the forward velocity. This paper describes the design of a basic orbital reboost maneuver based on a burn-coast-burn scenario and a closed-loop attitude control system which will control the firing sequences of the jets to maintain the spacecraft attitude within required bounds. The design is then used to investigate the infuence of the elastic component response on the reboost jet firing logic.
Alstom Power Inc. (Alstom), under U.S. DOE/NETL Cooperative Agreement No. DE-NT0005290, is conducting a development program to generate detailed technical information needed for application of oxy-combustion technology. The program is designed to provide the necessary information and understanding for the next step of large-scale commercial demonstration of oxy combustion in tangentially fired boilers and to accelerate the commercialization of this technology. The main project objectives include: • Design and develop an innovative oxyfuel system for existing tangentially-fired boiler units that minimizes overall capital investment and operating costs. • Evaluate performance of oxyfuel tangentially fired boiler systems in pilot scale tests at Alstom’s 15 MWth tangentially fired Boiler Simulation Facility (BSF). • Address technical gaps for the design of oxyfuel commercial utility boilers by focused testing and improvement of engineering and simulation tools. • Develop the design, performance and costs for a demonstration scale oxyfuel boiler and auxiliary systems. • Develop the design and costs for both industrial and utility commercial scale reference oxyfuel boilers and auxiliary systems that are optimized for overall plant performance and cost. • Define key design considerations and develop general guidelines for application of results to utility and different industrial applications. The project was initiated in October 2008 and the scope extended in 2010 under an ARRA award. The project completion date was April 30, 2014. Central to the project is 15 MWth testing in the BSF, which provided in-depth understanding of oxy-combustion under boiler conditions, detailed data for improvement of design tools, and key information for application to commercial scale oxy-fired boiler design. Eight comprehensive 15 MWth oxy-fired test campaigns were performed with different coals, providing detailed data on combustion, emissions, and thermal behavior over a matrix of fuels, oxyprocess variables and boiler design parameters. Significant improvement of CFD modeling tools and validation against 15 MWth experimental data has been completed. Oxy-boiler demonstration and large reference designs have been developed, supported with the information and knowledge gained from the 15 MWth testing. The results from the 15 MWth testing in the BSF and complimentary bench-scale testing are addressed in this volume (Volume II) of the final report. The results of the modeling efforts (Volume III) and the oxy boiler design efforts (Volume IV) are reported in separate volumes.
Alstom Power Inc. (Alstom), under U.S. DOE/NETL Cooperative Agreement No. DE-NT0005290, is conducting a development program to generate detailed technical information needed for application of oxy-combustion technology. The program is designed to provide the necessary information and understanding for the next step of large-scale commercial demonstration of oxy combustion in tangentially fired boilers and to accelerate the commercialization of this technology. The main project objectives include: Design and develop an innovative oxyfuel system for existing tangentially-fired boiler units that minimizes overall capital investment and operating costs; Evaluate performance of oxyfuel tangentially fired boiler systems in pilot scale tests at Alstom’s 15 MWth tangentially fired Boiler Simulation Facility (BSF); Address technical gaps for the design of oxyfuel commercial utility boilers by focused testing and improvement of engineering and simulation tools; Develop the design, performance and costs for a demonstration scale oxyfuel boiler and auxiliary systems; Develop the design and costs for both industrial and utility commercial scale reference oxyfuel boilers and auxiliary systems that are optimized for overall plant performance and cost; and, Define key design considerations and develop general guidelines for application of results to utility and different industrial applications. The project was initiated in October 2008 and the scope extended in 2010 under an ARRA award. The project is scheduled for completion by April 30, 2014. Central to the project is 15 MWth testing in the BSF, which provided in-depth understanding of oxy-combustion under boiler conditions, detailed data for improvement of design tools, and key information for application to commercial scale oxy-fired boiler design. Eight comprehensive 15 MWth oxy-fired test campaigns were performed with different coals, providing detailed data on combustion, emissions, and thermal behavior over a matrix of fuels, oxy-process variables and boiler design parameters. Significant improvement of CFD modeling tools and validation against 15 MWth experimental data has been completed. Oxy-boiler demonstration and large reference designs have been developed, supported with the information and knowledge gained from the 15 MWth testing. This report addresses the results from the 15 MWth testing in the BSF.
Photosynthetic algal cultivation has been intensively studied for CO 2 capture and utilization for several decades. The footprint for using algae to capture CO 2 emitted from carbon-intensive industrial processes (power plants, cement plants, and fermentation processes) is extremely large, which creates serious technical and economic hurdles that must be cleared if algal technologies are to be commercially implemented. Fortunately, algal biomass is rich in proteins, carbohydrates, and lipids, providing a good chemical source for organic absorbents and other value-added chemical feedstocks. In particular, amino acids from algal protein can be used to generate amino acid salt solutions that have been proven to be effective for capturing CO 2 . In order to take advantage of both algal cultivation and biomass utilization, the goal of the proposed project is to develop a combined biological and chemical system for coal-fired power plants for sequestering CO 2 in biological absorbents and generating value-added products. This approach significantly reduces the land and energy footprint of CO 2 capture, and minimizes capital and operational expenses. Three specific objectives are targeted: 1) optimizing the growth of the selected algal strain to maximize biomass accumulation from the coal-fired flue gas; 2) developing a cascade biomass utilization to produce amino acid absorbents, polyurethanes, biodiesel, and methane; and 3) conducting techno-economic analysis (TEA) and life cycle assessment (LCA) of the proposed process. Three key technical outcomes were achieved: (1) With the selected robust algal strain and unique photobioreactor design, long-term culture stability can be extended, and algal biomass productivity reached 0.5 g dry biomass/L/day year-round at a biomass concentration of 1.2 g/L in the pilot photobioreactor; (2) The biomass utilization process led to complete utilization of the algal biomass to produce amino acid salt absorbent, polyurethanes, and methane; and (3) The combined biological and chemical flue gas utilization process concluded a technically and economically feasible commercial-scale system that completely captures CO 2 in coal-fired flue gas with greatly reduced energy consumption.
The talk will include review of the MODIS (Moderate Resolution Imaging Spectrometer) algorithms and performance e.g. the MODIS algorithm and the changes in the algorithm since launch. Comparison of MODIS and ASTER fire observations. Summary of the fall activity with the Forest Service in use of MODIS data for the fires in the North-West. Validation on the ground of the MODIS fire product.
One of the major goals of new grid operation regimes, such as transactive energy systems (TESs), is to make the power grid more resilient to withstand natural or man-made disasters and potential reliability events, and to continue to serve the maximum number of its customers. But it is a well-known fact to system operators that not all customers are the same. This implies that any discussion of TESs’ impacts on the resilience of the power system should consider the needs of its critical customers (such as the power system operation centers, fire and police stations, and hospitals) over those of other customers. When evaluating the resilience of the system, bonus points must be awarded to any system that could maintain its power supply to critical customers during a disturbance that may cause an outage. This report discusses critical infrastructure (CI) as found in the literature and then categorizes it based on the field to which the operations belong (such as human life/safety-related, operations management, necessary city operation, industrial customers, etc.). Each of these CI categories is further divided into types of critical customers (e.g., the human life/safety-related category has different types of customers like hospitals, fire and police stations, etc.). The entire demand of each of the critical customer types is not categorized as critical load (CL); instead, only a portion of the total load of these critical customers is characterized as critical load. This is done based on the categories of equipment, the function of which is crucial in the operation of the overall facility. CL categorization is performed to provide the ratio of the critical load portion to the overall load , so that it can serve as a parameter in the resilience evaluation of the grid through a metrics-based approach. Such categorization is important as it helps to augment the existing quantifiable resilience metrics with CL categorization. The metrics for a power system need to not only consider how well a system performed during a disturbance event, but also how it reduced strain and supplied power to its CLs. The first step in this process is characterize CLs in the system. After CL characterization, the next step is the inclusion of these loads in the resilience metrics. To that end, in this report weight-based augmentation of resilience metrics is proposed, where certain customers (the ones that are categorized as critical) are assigned higher weights than others. Though an overview of assigning weights to customers is discussed, there is no one-size-fits-all approach for every power system. The decisions made about assigning such weights to customers vary greatly from one operator to another, based on their unique systems and the current and predicted states of critical customers. This decision-making can include the type of disturbance event, which might only affect certain parts of the system. In general, analyzing critical customers before an event helps understand system vulnerabilities. It also helps in planning and conducting operations during the event, evaluating system performance after the event, and supporting better planning for future events. An alternative to the current practices of managing the grid for outages is an innovative TES, which has the potential to provide a platform for including distributed energy resources for managing CLs. This report also describes how TES qualities can help (1) to maintain power supply to critical customers for uninterrupted operations and (2) to restore lost power supply to the critical customers rapidly.
This paper discusses the engine system design, hot-fire test history and analyses for the RS-25 Adaptation Engine test series, a major hot-fire test series supporting the Space Launch System (SLS) program. The RS-25 is an evolution of the Space Shuttle Main Engine (SSME). Since the SLS mission profile and engine operating conditions differ from that experienced by the SSME, a test program was needed to verify that SLS-unique requirements could be met by the adapted legacy engines. A series of 18 tests, including one engine acceptance test, was conducted from January 2015 to October 2017, to directly support Exploration Mission-1 (EM-1), the first flight of SLS. These tests were the first hot-firings of legacy SSME hardware since 2009. Major findings are described along with top level overview of the engine system.
Predictive modeling and simulation of high power laser-target interactions is sufficiently undeveloped that full-scale, field testing is required to assess lethality of military directed-energy (DE) systems. The cost and complexity of such testing programs severely limit the ability to vary and optimize parameters of the interaction. Thus development of advanced simulation tools, validated by experiments under well-controlled and diagnosed laboratory conditions that are able to provide detailed physics insight into the laser-target interaction and reduce requirements for full-scale testing will accelerate development of DE weapon systems. The ultimate goal is a comprehensive end-to-end simulation capability, from targeting and firing the laser system through laser-target interaction and dispersal of target debris; a 'Stockpile Science' - like capability for DE weapon systems. To support development of advanced modeling and simulation tools requires laboratory experiments to generate laser-target interaction data. Until now, to make relevant measurements required construction and operation of very high power and complex lasers, which are themselves costly and often unique devices, operating in dedicated facilities that don't permit experiments on targets containing energetic materials. High power diode laser arrays, pioneered by LLNL, provide a way to circumvent this limitation, as such arrays capable of delivering irradiances characteristic of De weapon requires are self-contained, compact, light weight and thus easily transportable to facilities, such as the High Explosives Applications Facility (HEAF) at Lawrence Livermore National Laboratory (LLNL) where testing with energetic materials can be performed. The purpose of this study was to establish the feasibility of using such arrays to support future development of advanced laser lethality and vulnerability simulation codes through providing data for materials characterization and laser-material interaction models and to validate the accuracy of code predictions. This project was a Feasibility Study under the LLNL Laboratory Directed Research and Development (LDRD) Program.
A three part technical study was conducted whereby parametric technical and economic feasibility data were developed on several power conversion systems suitable for the generation of central station electric power through the combustion of hydrogen and the use of the resulting heat energy in turbogenerator equipment. The study assessed potential applications of hydrogen-fueled power conversion systems and identified the three most promising candidates: (1) Ericsson Cycle, (2) gas turbine, and (3) direct steam injection system for fossil fuel as well as nuclear powerplants. A technical and economic evaluation was performed on the three systems from which the direct injection system (fossil fuel only) was selected for a preliminary conceptual design of an integrated hydrogen-fired power conversion system.
Early implementation of structural dynamics finite element analyses for calculation of design loads is considered common design practice for high volume manufacturing industries such as automotive and aeronautical industries. However with the rarity of rocket engine development programs starts, these tools are relatively new to the design of rocket engines. In the NASA MC-1 engine program, the focus was to reduce the cost-to-weight ratio. The techniques for structural dynamics analysis practices, were tailored in this program to meet both production and structural design goals. Perturbation of rocket engine design parameters resulted in a number of MC-1 load cycles necessary to characterize the impact due to mass and stiffness changes. Evolution of loads and load extraction methodologies, parametric considerations and a discussion of load path sensitivities are important during the design and integration of a new engine system. During the final stages of development, it is important to verify the results of an engine system model to determine the validity of the results. During the final stages of the MC-1 program, hot-fire test results were obtained and compared to the structural design loads calculated by the engine system model. These comparisons are presented in this paper.
Diffusion flames are commonly used for industrial burners in furnaces and flares. Oxygen/fuel burners are usually diffusion burners, primarily for safety reasons, to prevent flashback and explosion in a potentially dangerous system. Furthermore, in most fires, condensed materials pyrolyze, vaporize, and burn in air as diffusion flames. As a result of the interaction of a diffusion flame with burner or condensed-fuel surfaces, a quenched space is formed, thus leaving a diffusion flame edge, which plays an important role in flame holding in combustion systems and fire spread through condensed fuels. Despite a long history of jet diffusion flame studies, lifting/blowoff mechanisms have not yet been fully understood, compared to those of premixed flames. In this study, the structure and stability of diffusion flames of gaseous hydrocarbon fuels in coflowing air at normal earth gravity have been investigated experimentally and computationally. Measurements of the critical mean jet velocity (U(sub jc)) of methane, ethane, or propane at lifting or blowoff were made as a function of the coflowing air velocity (U(sub a)) using a tube burner (i.d.: 2.87 mm) (Fig. 1, left). By using a computational fluid dynamics code with 33 species and 112 elementary reaction steps, the internal chemical-kinetic structures of the stabilizing region of methane and propane flames were investigated (Fig. 1, right). A peak reactivity spot, i.e., reaction kernel, is formed in the flame stabilizing region due to back-diffusion of heat and radical species against an oxygen-rich incoming flow, thus holding the trailing diffusion flame. The simulated flame base moved downstream under flow conditions close to the measured stability limit.
Diffusion flames are commonly used for industrial burners in furnaces and flares. Oxygen/fuel burners are usually diffusion burners, primarily for safety reasons, to prevent flashback and explosion in a potentially dangerous system. Furthermore, in most fires, condensed materials pyrolyze, vaporize, and burn in air as diffusion flames. As a result of the interaction of a diffusion flame with burner or condensed-fuel surfaces, a quenched space is formed, thus leaving a diffusion flame edge, which plays an important role in flame holding in combustion systems and fire spread through condensed fuels. Despite a long history of jet diffusion flame studies, lifting/blowoff mechanisms have not yet been fully understood, compared to those of premixed flames. In this study, the structure and stability of diffusion flames of gaseous hydrocarbon fuels in coflowing air at normal earth gravity have been investigated experimentally and computationally. Measurements of the critical mean jet velocity (U(sub jc)) of methane, ethane, or propane at lifting or blowoff were made as a function of the coflowing air velocity (U(sub a)) using a tube burner (i.d.: 2.87 mm). By using a computational fluid dynamics code with 33 species and 112 elementary reaction steps, the internal chemical-kinetic structures of the stabilizing region of methane and propane flames were investigated. A peak reactivity spot, i.e., reaction kernel, is formed in the flame stabilizing region due to back-diffusion of heat and radical species against an oxygen-rich incoming flow, thus holding the trailing diffusion flame. The simulated flame base moved downstream under flow conditions close to the measured stability limit.
In the transition toward sustainable energy systems, the co-firing of hydrogen (H2) with natural gas emerges as a critical technology for cleaner power generation. This study examines its benefits, including emissions reduction, enhanced efficiency, and compatibility with existing infrastructure. Concurrently, it addresses the inherent challenges, such as combustion dynamics, necessary infrastructure modifications, and economic considerations. Incorporating global case studies, the review explores recent advancements in hydrogen production and co-firing, evaluating their practicality and operational efficiency. It also provides a critical examination of the economic implications and societal acceptance, which are crucial for the adoption of hydrogen technologies. Moreover, the review investigates the synergy between hydrogen and renewable energy technologies, assessing potential impacts on energy policy and regulation. Ultimately, this comprehensive analysis underscores the essential role of hydrogen co-firing in the energy sector and advocates for a comprehensive strategy that synergizes technological progress, economic viability, regulatory support, and public engagement to promote a resilient and sustainable energy future.