Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flight Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A technique for verifying the input response function of neutron time-of-flight scintillation detectors using cosmic rays

An accurate interpretation of DD or DT fusion neutron time-of-flight (nTOF) signals from current mode detectors employed at the Z-facility at Sandia National Laboratories requires that the instrument response functions (IRF’s) be deconvolved from the measured nTOF signals. A calibration facility that produces detectable sub-ns radiation pulses is typically used to measure the IRF of such detectors. This work, however, reports on a simple method that utilizes cosmic radiation to measure the IRF of nTOF detectors, operated in pulse-counting mode. The characterizing metrics reported here are the throughput delay and full-width-at-half-maximum. This simple approach yields consistent IRF results with the same detectors calibrated in 2007 at a LINAC bremsstrahlung accelerator (Idaho State University). In particular, the IRF metrics from these two approaches and their dependence on the photomultipliers bias agree to within a few per cent. This information may thus be used to verify if the IRF for a given nTOF detector employed at Z has changed since its original current-mode calibration and warrants re-measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Narrow-linewidth laser cooling for rapid production of low-temperature atoms for high data-rate quantum sensing

We present a proof-of-concept demonstration of a narrow linewidth $^{87}$Rb magneto-optical trap (MOT) operating on the narrow linewidth $5S_{1/2}$ → $6P_{3/2}$ transition at 420 nm. We stabilized the absolute frequency of the 420 nm laser to an atomic transition in $^{87}$Rb and demonstrate a MOT using 420 nm light driving the $5S_{1/2}$, $F = 2$ → $6P_{3/2}, F' = 3$ transition. We then use tome-of-flight measurements to characterize the 420 nm MOT temperature, observing a minimum temperature of about $T^{(420)}_{horizontal}$ = 150μK and $T^{(420)}_{vertical}$ = 250μK before the opportunity to perform significant characterization and optimization. Although this temperature is significantly higher then the expected 420 nm Doppler cooling limit ($T_D^{(420)}$ ≈ 34 μK), these are already approaching the Doppler limit of a standard 780 nm MOT ($T_D^{(780)}$ ≈ 146 μK). We believe that with further optimization the Doppler cooling limit of ≈ 34 μK can be achieved. This initial result answers our key research question and demonstrates the viability of applying narrow linewidth laser cooling as a robust technique for future fieldable quantum sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First Calorimetric Energy Reconstruction of Beam Events with ARAPUCA Light Detector in ProtoDUNE-SP

ProtoDUNE Single Phase at CERN is the large scale prototype for the far detector of the future DUNE experiment. ProtoDUNE is in stable operation since Oct. 2018 at the CERN Neutrino Platform. Test beam data in the energy range of sub-GeV to a few GeV were collected in fall 2018 providing a set of key measurements. Particles (electrons, protons, pions, muons and kaons) are identified combining information from a set of beam-line detectors (Time of Flight, Cherenkov) and TPC reconstruction. Three different technologies are implemented in the protoDUNE photon detector system (PDS). Results from the ARAPUCA response, one of the PDS components, are presented providing first calorimetric energy measurements and particle ID of beam events from LAr scintillation light signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of apparent ion temperature using the magnetic recoil spectrometer at the OMEGA laser facility

The Magnetic Recoil neutron Spectrometer (MRS) at the OMEGA laser facility has been routinely used to measure deuterium-tritium (DT) yield and areal density in cryogenically layered implosions since 2008. Recently, operation of the OMEGA MRS in higher-resolution mode with a new smaller, thinner (4 cm[sup]2, 57-um thick) CD2 conversion foil has also enabled inference of the apparent DT ion temperature (Tion) from MRS data. MRS-inferred Tion compares well with T[sub]ion as measured using neutron time-of-flight spectrometers, which is important as it demonstrates good understanding of the very different systematics associated with the two independent measurements. The MRS resolution in this configuration, deltaEMRS=0.91 MeV FWHM, is still higher than required for a high-precision Tion measurement. We show how fielding a smaller foil closer to target chamber center and redesigning the MRS detector array could bring the resolution to deltaEMRS=0.45 MeV, reducing the systematic Tion uncertainty by more than a factor of 4.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Cibola flight experiment

The Cibola Flight Experiment (CFE) is an experimental small satellite carrying a reconfigurable processing instrument developed at the Los Alamos National Laboratory that demonstrates the feasibility of using FPGA-based high-performance computing for sensor processing in the space environment. The CFE satellite was launched on March 8, 2007 in low-earth orbit and has operated extremely well since its deployment. The nine Xilinx Virtex FPGAs used in the payload have been used for several high-throughput sensor processing applications and for single-event upset (SEU) monitoring and mitigation. This paper will describe the CFE system and summarize its operational results. In addition, this paper will describe the results from several SEU detection circuits that were performed on the spacecraft.

97 MATHEMATICS AND COMPUTING↗

Numerical investigation of thermomechanical response of multiscale porous Ultra-High Temperature Ceramics

Recent advances in Ultra-High Temperature Ceramics (UHTC) manufacturing have permitted the development of multiscale porous UHTC microstructures. Within the target application of hypersonic vehicles, dense UHTCs are suitable for thermal protection on leading edges, whereas porous UHTCs may find a role in providing thermally insulated interfaces for temperature-sensitive interior components. Designing vehicles incorporating porous UHTCs requires a characterization of their thermomechanical properties across the full range of expected operating temperatures spanning –20 °C–2500 °C. This research represents a preliminary study in performing this characterization. Several numerical experiments are performed using a coupled thermomechanical implementation of the Material Point Method to determine the temperature dependence of effective material properties both with and without damage. Furthermore, complex time-dependent boundary conditions derived from known hypersonic flight profiles are simulated in order to probe the various couplings between deformation, damage and heat transfer. It is shown that the model reveals the importance of micro-buckling in determining effective material stiffness and thermal conductivity.

36 MATERIALS SCIENCE↗

Measurement of apparent ion temperature using the magnetic recoil spectrometer at the OMEGA laser facility

The Magnetic Recoil neutron Spectrometer (MRS) at the OMEGA laser facility has been routinely used to measure deuterium-tritium (DT) yield and areal density in cryogenically layered implosions since 2008. Recently, operation of the OMEGA MRS in higher-resolution mode with a new smaller, thinner (4 cm 2 , 57 μm thick) CD 2 conversion foil has also enabled inference of the apparent DT ion temperature (T ion ) from MRS data. MRS-inferred T ion compares well with T ion as measured using neutron time-of-flight spectrometers, which is important as it demonstrates good understanding of the very different systematics associated with the two independent measurements. The MRS resolution in this configuration, $ΔE_{MRS}$ = 0.91 MeV FWHM, is still higher than that required for a high-precision T ion measurement. We show herein how fielding a smaller foil closer to the target chamber center and redesigning the MRS detector array could bring the resolution to $ΔE_{MRS}$ = 0.45 MeV, reducing the systematic T ion uncertainty by more than a factor of 4.

47 OTHER INSTRUMENTATION↗

Evaluating the Effectiveness of a Detection and Deterrent System in Reducing Golden Eagle Fatalities at Operational Wind Facilities

The Renewable Energy Wildlife Institute (REWI) was appointed as the prime awardee of DOE award number DE-EE0007883 to lead a team of scientists, wind developers, and technology manufacturers toward the overarching goal of evaluating the effectiveness of the current DTBird system in minimizing the risk of golden eagles (Aquila chrysaetos) and other large soaring raptors from approaching the rotor-swept zone (RSZ) of operating wind turbines. As part of this goal, the team set out to 1) quantify the expected reduction in collision risk for golden eagles from operation of the detection and deterrence modules in a manner that supports the approach used by the U.S. Fish and Wildlife Service (USFWS) to assess and credit facility operators for their efforts to minimize predicted collision fatalities and 2) provide information to help improve the technology to maximize its effectiveness. DTBird is an automated detection and audio deterrent system created by the Spanish company Liquen, designed to discourage birds from entering the RSZ of spinning wind turbines. The system uses cameras to automatically detect airborne targets of interest, records each such event in an online database, and triggers a warning signal (loud sound) if the tracked object has moved close to the turbine. If the object moves even closer to the RSZ, a more aggressive dissuasion signal is broadcast. To meet our objectives, the team conducted a two-year experiment at the Goodnoe Hills wind facility in Washington state, in which 14 turbines were outfitted with DTBird units. Daily, each DTBird-equipped turbine was randomly assigned to a control or treatment group. Treatment turbines operated with DTBird running as intended—broadcasting warning or deterrent signals when DTBird detected a target within range. On control turbines, no sound signals were broadcast if a moving target triggered the DTBird system. The team also flew unmanned aerial vehicles (UAVs) designed to coarsely mimic the general size, weight, and coloration of golden eagles in programmed flight transects across DTBird detection ranges to quantify DTBird’s ability to detect intended targets and to evaluate factors that influence the probability of detection and DTBird’s response distances. Additionally, the team evaluated the behavioral responses of in situ eagles exposed to spinning turbines alone (visual and sound influences) versus spinning turbines plus broadcasted DTBird audio deterrents, to estimate the effectiveness of deterrence by the DTBird system. The data and results from these investigations were combined with those from a pilot study conducted at the Manzana Wind Power Project in California to better evaluate DTBird’s effectiveness across different landscapes.

17 WIND ENERGY↗

IMAGING ANALYSIS OF THE HARD X-RAY TELESCOPE ProtoEXIST2 AND NEW TECHNIQUES FOR HIGH-RESOLUTION CODED-APERTURE TELESCOPES

Wide-field (≳100 deg{sup 2}) hard X-ray coded-aperture telescopes with high angular resolution (≲2′) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

79 ASTRONOMY AND ASTROPHYSICS↗

Combined distance-of-flight and time-of-flight mass spectrometer

A combined distance-of-flight mass spectrometry (DOFMS) and time-of-flight mass spectrometry (TOFMS) instrument includes an ion source configured to produce ions having varying mass-to-charge ratios, a first detector configured to determine when each of the ions travels a predetermined distance, a second detector configured to determine how far each of the ions travels in a predetermined time, and a detector extraction region operable to direct portions of the ions either to the first detector or to the second detector.

47 OTHER INSTRUMENTATION↗

Small mover target detection in synthetic aperture radar imagery

The various technologies presented herein relate to detecting small moving entities or targets in radar imagery. Two SAR images can be captured for a common scene, wherein the scene is imaged twice from the same flight path. The first image is captured at a first instance and the second image is captured at a second instance, and differences between the two images are determined using a complex SAR change measure, excess coherency factor or DeltaC, based in part upon quantification of incoherent (or magnitude) change between the two images. A plurality of operations are performed to enable extraction of coherent change measures relating to the small moving entities from measures relating to large objects, stationary reflective structures, radar focusing artifacts, etc.

Simonson, Katherine M.↗

MICE: The International Muon Ionization Cooling Experiment: Diagnostic Systems

The Muon Ionization Cooling Experiment will make detailed measurements of muon ionization cooling using a new constructed low-energy muon beam at the Rutherford Appleton Laboratory (RAL). The experiment is a single-particle experiment and utilizes many detector techniques from high energy physics experiments. To characterize and monitor the muon beamline, newly developed scintillating fiber profile monitors and scintillator paddle rate monitors are employed. In order to monitor the purity of the beam and tag the arrival time of individual muons, a dual aerogel Cherenkov system is used, and a plastic scintillator time-of-flight system will be used. The phase-space vectors of the muons will be measured by two identical spectrometer systems (one before and one after the cooling apparatus) which employ a fiber tracker system, and electron and muon calorimeters are used to tag outgoing muons. We will discuss the design of the MICE diagnostic systems, the operation, and give the first results from beam measurements in the MICE experimental hall.

43 PARTICLE ACCELERATORS↗

Development of a new ion mobility time-of-flight mass spectrometer

Complex samples require multidimensional measurements with high resolution for full characterization of biological and environmental systems. To address this challenge, we developed a drift tube-based ion mobility spectrometry-Orbitrap mass spectrometry (IMS-Orbitrap MS) platform. To circumvent the timing difference between the fast IMS separation and the slow Orbitrap MS acquisition, we utilized a dual gate and pseudorandom sequence to multiplex ions into the drift tube and Orbitrap. The instrument was designed to operate in signal averaging (SA), single multiplexing (SM) and double multiplexing (DM) IMS modes to fully optimize the signal-to-ratio of the measurements. For the SM measurements, a previously developed algorithm was used to reconstruct the IMS data, while a new algorithm was developed for the DM analyses. The new algorithm is a two-step process that first recovers the SM data from the encoded DM data and then decoded the SM data. The algorithm also performs multiple refining procedures in order to minimize the demultiplexing artifacts traditionally observed in such scheme. The new IMS-Orbitrap MS platform was demonstrated for the analysis of proteomic and petroleum samples, where the integration of IMS and high mass resolution proved essential for accurate assignment of molecular formulae.

47 OTHER INSTRUMENTATION↗

SimELIT: A Novel GUI-Based Comprehensive Ion Trajectory Simulation Software for Mass Spectrometry

Ion trajectory simulation in mass spectrometry systems from injection to detection is technically challenging but very important for better understanding the ion dynamics in instrument development. Here, in this work, we present SimELIT (Simulator of Eulerian and Lagrangian Ion Trajectories), a novel ion trajectory simulation platform. SimELIT is built upon a suite of multiphysics solvers compiled into OpenFOAM (an open-source numerical solver library particularly used for computational mechanics), with a simple web-based graphical user interface (GUI) allowing users to define the details of OpenFOAM cases and run simulations. SimELIT is a modular program and can provide extensions of physics (e.g., gas flows, electrodynamic fields) and thus enable ion trajectory simulations from the ion source to detector. The current version (SimELIT) provides two numerical solvers for ion trajectory simulations–(1) a Lagrangian particle tracker in vacuum and (2) a Eulerian ion density solver in background gas in the presence of electric fields. Here, we describe the architecture of SimELIT, including its use of Docker and the React Framework, and demonstrate the computation of ion trajectories of multiple m/z values in a static/linear voltage drop in vacuum (across a 1 m long flight tube). Further, the drift motion of ions under 1 Torr pressure conditions in a static background (N 2 ) gas through a 20 V/cm static electric field is shown. The results produced from SimELIT were compared with SIMION and theoretical estimates. In addition, we report the computation of ion trajectories in electrodynamic fields within a planar FAIMS device operating at atmospheric pressure.

97 MATHEMATICS AND COMPUTING↗

Breaking through the false coincidence barrier in electron–ion coincidence experiments

Photoelectron Photoion Coincidence (PEPICO) spectroscopy holds the promise of a universal, isomer-selective, and sensitive analytical technique for time-resolved quantitative analysis of bimolecular chemical reactions. Unfortunately, its low dynamic range of ~10 3 has largely precluded its use for this purpose, where a dynamic range of at least 10 5 is generally required. This limitation is due to the false coincidence background common to all coincidence experiments, especially at high count rates. Electron/ion pairs emanating from separate ionization events but arriving within the ion time of flight (TOF) range of interest constitute the false coincidence background. Although this background has uniform intensity at every m/z value, the Poisson scatter in the false coincidence background obscures small signals. In this paper, temporal ion deflection coupled with a position-sensitive ion detector enables suppression of the false coincidence background, increasing the dynamic range in the PEPICO TOF mass spectrum by 2–3 orders of magnitude. The ions experience a time-dependent electric deflection field at a well-defined fraction of their time of flight. This deflection defines an m/z- and ionization-time dependent ion impact position for true coincidences, whereas false coincidences appear randomly outside this region and can be efficiently suppressed. When cold argon clusters are ionized, false coincidence suppression allows us to observe species up to Ar 9 + , whereas Ar 4 + is the largest observable cluster under traditional operation. As a result, this advance provides mass-selected photoelectron spectra for fast, high sensitivity quantitative analysis of reacting systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A System Level Comparative Study of SecondarySide Rectifiers for UAV Wireless Power Transfer in High-Altitude Airborne Energy Platforms

Wireless power transfer (WPT) systems for unmanned aerial vehicles (UAVs) must satisfy stringent design requirements to ensure reliable operation under constraints related to efficiency, thermal performance, altitude, weight, and reliability, particularly in airborne and high-altitude environments. Thermal management becomes increasingly challenging at higher altitudes due to reduced air density, while reliability is strongly affected by the number and complexity of active components. The weight and compactness of secondary-side rectifiers directly impact UAV flight endurance and system integration, influencing energy consumption and payload allocation. These factors collectively define the practical feasibility of UAV WPT systems and guide rectifier topology selection. This paper presents a comparative and experimentally validated evaluation framework for secondary-side rectifiers under UAV-specific constraints. Three representative rectifier architectures are analyzed using component-based assessment of weight, thermal behavior, and reliability, together with experimental efficiency measurements obtained from a 1 kW WPT prototype. The results show that the single-switch active rectifier achieves the highest peak efficiency of approximately 93.2% and an overall efficiency of 91%, while also offering advantages in weight and reliability. The findings demonstrate how constraint-oriented analysis, combined with experimental validation, enables informed selection of secondary-side rectifiers for UAV wireless power transfer applications, including emerging airborne and high-altitude platforms.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

HITMAN

HITMAN (Hermite Interpolation of Trajectories and Measurement Synthesis for Analysis of Navigators) interpolates—or estimates the unknown values between known values—flight trajectories and generates synthetic inertial measurement unit (IMU) data using Hermite splines. This Python library provides modeling and simulation capabilities to synthesize inertial measurements from discrete trajectory points, enabling researchers to create exemplar datasets for evaluating navigation algorithms in various applications, including consumer devices like smartphones and vehicles. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Walker II, Michael [Sandia National Lab. (SNL-CA),↗

Bat Impact Minimization Technology: An Improved Bat Deterrent for the Full Swept Rotor Area of Any Wind Turbine

The growth in the number of wind turbine generators has led to a significant number of fatal interactions with bat species. The need to reduce the number of bat fatalities while minimizing power losses is the greatest conservation challenge for wind energy development in parts of the country, according to the American Wind Wildlife Institute. Technological solutions that can also allow turbines to operate normally would generate the maximum electricity and avoid financial losses. Bats use echolocation to perceive their surroundings by listening to features of echoes from their high frequency vocal signals reflecting from targets. In this project, Frontier Wind built on previous research demonstrating that ultrasonic noise can mask echolocation and act as a repellent or deterrent to bat flight activity. Whereas the initial study only broadcast ultrasonic transmissions from the center of the turbine, the Strike Free™ system developed for this project extended the ultrasonic coverage to the entire area swept by the turbine blades. Frontier Wind designed the system components and their integration and then tested them in the lab and in the field at Pattern Energy’s Hatchet Ridge Wind Facility near Redding, California. The researchers used an acoustic model to determine the optimal configuration of transmitters along the blades to provide sound transmission coverage across the turbine rotor swept area volume. The custom ultrasonic transmitters were designed specifically for the echolocation frequencies of the four main bat species that have been shown to have died at Hatchet Ridge, although the transmitters can be customized for different frequencies as needed in other geographic locations. The Strike Free™ system shows promise for reducing bat fatalities, and the path to commercialization requires further testing to validate and optimize performance in the field.

17 WIND ENERGY↗