Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Overland flow numerical model prediction, Lower Triangle Region in East River Watershed, Colorado, 3 days

This data package contains numerical simulation results of surface flow variables such as flow velocity and water depth in Lower Triangle Region in East River Watershed, Colorado. The surface flow is a consequence of a high intensity rainfall event with a total duration of 3 days, available at a resolution of 10 minutes. The results are computed on triangular multiresolution meshes with resolutions ranging from 10 meter to 80 meter. The data package also contains a simulation on a uniform triangular mesh with a resolution of 10 meter. The simulations consider surface flow only and neglect subsurface flow, infiltration, and evapotranspiration. The purpose of the data is to assess the quality of a mesh refinement strategy.

54 ENVIRONMENTAL SCIENCES↗

Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

Arkin, C.↗

Active bypass flow control for a seal in a gas turbine engine

An active bypass flow control system for controlling bypass compressed air based upon leakage flow of compressed air flowing past an outer balance seal between a stator and rotor of a first stage of a gas turbine in a gas turbine engine is disclosed. The active bypass flow control system is an adjustable system in which one or more metering devices may be used to control the flow of bypass compressed air as the flow of compressed air past the outer balance seal changes over time as the outer balance seal between the rim cavity and the cooling cavity wears. In at least one embodiment, the metering device may include a valve formed from one or more pins movable between open and closed positions in which the one pin at least partially bisects the bypass channel to regulate flow.

33 ADVANCED PROPULSION SYSTEMS↗

MBM fuel feeding system design and evaluation for FBG pilot plant

Highlights: Black-Right-Pointing-Pointer A 1-5 g/s fuel feeding system for pilot scale FBG was designed, built and tested. Black-Right-Pointing-Pointer Multiple conveying stages improve pressure balancing, flow control and stability. Black-Right-Pointing-Pointer Secondary conveyor stage reduced output irregularity from 47% to 15%. Black-Right-Pointing-Pointer Pneumatic air sparging effective in dealing with poor flow ability of MBM powder. Black-Right-Pointing-Pointer Pneumatic injection port plugs with char at gasification temperature of 850 Degree-Sign C. - Abstract: A biomass fuel feeding system has been designed, constructed and evaluated for a fluidized bed gasifier (FBG) pilot plant at the University of Saskatchewan (Saskatoon, SK, Canada). The system was designed for meat and bone meal (MBM) to be injected into the gasifier at a mass flow-rate range of 1-5 g/s. The designed system consists of two stages of screw conveyors, including a metering stage which controlled the flow-rate of fuel, a rotary airlock and an injection conveyor stage, which delivered that fuel at a consistent rate to the FBG. The rotary airlock which was placed between these conveyors, proved unable to maintain a pressure seal, thus the entire conveying system was sealed and pressurized. A pneumatic injection nozzle was also fabricated, tested and fitted to the end of the injection conveyor for direct injection and dispersal into the fluidized bed. The 150 mm metering screw conveyor was shown to effectively control the mass output rate of the system, across a fuel output range of 1-25 g/s, while the addition of the 50 mm injection screw conveyor reduced the irregularity (error) of the system output rate from 47% to 15%. Although material plugging was found to be an issue in the inlet hopper to the injection conveyor, the addition of air sparging ports and a system to pulse air into those ports was found to successfully eliminate this issue. The addition of the pneumatic injection nozzle reduced the output irregularity further to 13%, with an air supply of 50 slpm as the minimum air supply to drive this injector. After commissioning of this final system to the FBG reactor, the injection nozzle was found to plug with char however, and was subsequently removed from the system. Final operation of the reactor continues satisfactorily with the two screw conveyors operating at matching pressure with the fluidized bed, with the output rate of the system estimated based on system characteristic equations, and confirmed by static weight measurements made before and after testing. The error rate by this method is reported to be approximately 10%, which is slightly better than the estimated error rate of 15% for the conveyor system. The reliability of this measurement prediction method relies upon the relative consistency of the physical properties of MBM with respect to its bulk density and feeding characteristics.

09 BIOMASS FUELS↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Active bypass flow control for a seal in a gas turbine engine

An active bypass flow control system for controlling bypass compressed air based upon leakage flow of compressed air flowing past an outer balance seal between a stator and rotor of a first stage of a gas turbine in a gas turbine engine is disclosed. The active bypass flow control system is an adjustable system in which one or more metering devices may be used to control the flow of bypass compressed air as the flow of compressed air past the outer balance seal changes over time as the outer balance seal between the rim cavity and the cooling cavity wears In at least one embodiment, the metering device may include an annular ring having at least one metering orifice extending therethrough, whereby alignment of the metering orifice with the outlet may be adjustable to change a cross-sectional area of an opening of aligned portions of the outlet and the metering orifice.

33 ADVANCED PROPULSION SYSTEMS↗

Impact of Janssen effect on thermal transport in granular flow

Using a modulated photothermal radiometry (MPR) technique capable of measuring thermal transport in particle beds, we find asymptotically increasing effective thermal conductivity and decreasing near-wall thermal resistance along gravity-driven downward granular flows through a 1-meter-long narrow vertical channel owing to the Janssen effect. The Janssen effect is confirmed by similar asymptotic trends from particle bed apparent mass measurements as well as separate MPR heat transfer measurements on stationary particle beds under compression at different heights of the channel with and without pressure screening. Furthermore, local heat transfer coefficient along the 1-meter-long channel was modeled based on measured spatially resolved thermal conductivity and near-wall thermal resistance due to the Janssen effect. This work reveals for the first time the impact of the over century-old Janssen effect on heat transfer in granular media. Furthermore, the results from this work can lead to a better understanding of heat transfer in granular flow.

14 SOLAR ENERGY↗

Mass flow rate measurements in gas-liquid flows by means of a venturi or orifice plate coupled to a void fraction sensor

Two-phase flow measurements were carried out using a resistive void fraction meter coupled to a venturi or orifice plate. The measurement system used to estimate the liquid and gas mass flow rates was evaluated using an air-water experimental facility. Experiments included upward vertical and horizontal flow, annular, bubbly, churn and slug patterns, void fraction ranging from 2% to 85%, water flow rate up to 4000 kg/h, air flow rate up to 50 kg/h, and quality up to almost 10%. The fractional root mean square (RMS) deviation of the two-phase mass flow rate in upward vertical flow through a venturi plate is 6.8% using the correlation of Chisholm (D. Chisholm, Pressure gradients during the flow of incompressible two-phase mixtures through pipes, venturis and orifice plates, British Chemical Engineering 12 (9) (1967) 454-457). For the orifice plate, the RMS deviation of the vertical flow is 5.5% using the correlation of Zhang et al. (H.J. Zhang, W.T. Yue, Z.Y. Huang, Investigation of oil-air two-phase mass flow rate measurement using venturi and void fraction sensor, Journal of Zhejiang University Science 6A (6) (2005) 601-606). The results show that the flow direction has no significant influence on the meters in relation to the pressure drop in the experimental operation range. Quality and slip ratio analyses were also performed. The results show a mean slip ratio lower than 1.1, when bubbly and slug flow patterns are encountered for mean void fractions lower than 70%. (author)

42 ENGINEERING↗

An analysis of maximum vertical gusts recorded at NASA's 150-meter ground winds tower facility at Kennedy Space Center, Florida

A statistical summary is presented of vertical wind speed data recorded at NASA's 150-Meter Ground Winds Tower Facility on Merritt Island, Kennedy Space Center, Florida. One year of continuous around-the-clock vertical wind speed measurements processed by the Automatic Data Acquisition System (ADAS) is classified as a function of tower level (10, 18, 60, and 150 meters) and period of reference day, month, season: winter (October through March) and summer (April through September), and annual. Intensity, frequency, time of occurrence, prevailing conditions, etc., of the daily maximum vertical gusts (i.e., updraft and downdraft) are determined. The results are compared with the vertical gusts associated with the daily maximum horizontal gust. The intent of this summarization of vertical wind speed data is to provide a general description of wind flow in the lower 150 meters of the atmosphere for the identification of hazards involved in wind shear encounters relative to ascent and descent of the Space Shuttle and conventional aircraft.

Alexander, M. B.↗

Volcanic recycling of carbonate deposits on Mars

One question of great interest to those who study the evolution of the Martian atmosphere is: if there was an early, dense atmosphere that was removed, is there any mechanism that could restore it? In the case of an atmosphere removed largely by the formation of carbonates, the only obvious means of restoring it is by the thermal decomposition of the carbonates. Decomposition of carbonates under turbulently flowing lava holds great promise as a means of resupplying the atmosphere with CO2. Huppert and colleagues have modeled the emplacement of terrestrial komatiite flows and found that komatiites, even when flowing over previously emplaced and cooled komatiite flows, could melt and erode this rock to a significant depth. Based on this work, I have begun modeling the erosion of Martian carbonate deposits under turbulently flowing, komatiitic lava. Initial results from this modeling indicate that a high-volume lava flow, emerging at a temperature of, say, 1600 degrees, is capable of eroding several meters of carbonate deposits per day. If such a flow is active for a hundred days, several hundreds of meters of carbonate could be decomposed. If this process occurred over a large area, a bar or more of CO2 could be injected back into the atmosphere over an extremely short period of time. The implications of such an occurrence are intriguing. For instance, if a relatively late pulse of volcanism (such as is suggested by Frey) were to cause a large flow of lava over carbonate deposits in the northern lowlands, the resulting pulse of CO2 into the atmosphere could conceivably restore the climate to one in which liquid water could exist on the surface, or ice could flow.

Schaefer, M. W.↗

An analysis of maximum horizontal wind speeds and associated parameters recorded at NASA's 150-Meter Ground Winds Tower facility at Kennedy Space Center, Florida

Continuous horizontal wind speed measurements were processed and classified as a function of tower level (10, 18, 60, and 150 meters) and period of reference day, month, season: winter (October through March) and summer (April through September), and annual. Tabulations were made of the daily maximum horizontal wind speed, time of ocurrence, and five associated parameters: mean horizontal wind speed, maximum vertical gusts (i.e., updraft and downdraft), and mean and instantaneous directions. Analyses using these data included means, extremes, standard deviations, and frequency distributions. Comparisons of intensity of maximum horizontal wind speeds determined in this year of data are made with maximum values recorded at Kennedy Space Center during another non-hurricane-occurrence year (1967) and with values during 1966 through 1972 when six hurricanes affected the area after the Ground Winds Tower facility became operational. Wind flow in the lowest 150 meters of the atmosphere was measured for the identification of hazards involved in wind shear encounter relative to ascent and descent of the space shuttle and conventional aircraft.

Alexander, M. B.↗

Snake River Plain Geothermal Play Fairway Analysis Project Active Source Seismic Data

This archive contains seismic shot field records for 10 profiles located in Camas Prairie, Idaho. The eight numbered .sgy files were acquired using a seismic land streamer system with an accelerated weight drop source and 72 geophones. These 10-Hz geophones were mounted on base plates and dragged behind the seismic source. Shots were acquired every 4 meters along the length of lines 500West, 550 West, 600West, 700West, 800West, 900West, 200South and 200North. The objective was to map stratigraphy and structures related to geothermal fluid flow in the upper few hundred meters. A readme file is included with descriptions of individual files. The lines names refer to to roads which are numbered relative to the distance from the county seat (the town of Fairfield) along the the main highways. For example, 500 West implies that this north-south street crosses the main road 5 miles to the west of town. The included geologic, topographic, and aerial maps show the labeled seismic lines, while the regional map shows only the line geometry and regional faulting.

15 GEOTHERMAL ENERGY↗

Development of an optically accessible continuous wave Rotating Detonation Engine

We have developed and characterized a race track RDE, which is an optically accessible RDE that combines a linearized detonation channel with a cyclic geometric shape that allows for the wave to be self sustaining and more representative of a typical RDE in operation. The Race Track RDE was designed for and operates with a two wave detonation system, traveling through an approximately meter long circuit whose internal flow geometry is that of a companion experimental six inch round RDE. In addition it behaves similarly to the six inch design in various bulk performance characteristics, including plenum pressure, CTAP profiles, and wave speed.

Chacon, Fabian↗

Hypersonic research engine project. Phase 2: Aerothermodynamic integration model development

The analytical effort was directed toward (1) analyzing the latest inputs of possible test conditions and their impact on hardware; (2) review structural capabilities of the AIM unit; (3) analyzing coolant flow paths, heat transfer, and associated problems relative to the cowl leading edge tip section; and (4) redefining requirements of flow-calibrating the air-metering duct.

Jilly, L. F.↗

Airframe noise of component interactions on a large transport model

Airframe noise produced by aircraft components and their interactions on a model of a wide body transport was investigated in an open jet anechoic flow facility. The two-meter span model had leading edge and multigapped trailing edge flaps, undercarriage, and associated stowage compartments. Each of these components were extended and retracted so their individual and interactive contributions to the measured airframe noise could be determined. An analysis of variance was performed which revealed a statistical significance of the component interactions. Various airframe noise reduction techniques were tried to reduce airframe noise. The effects of these techniques on the model's lift and drag were also measured.

Shearin, J. G.↗

Flow field studies using holographic interferometry at Langley

Some of the uses of holographic interferometry at Langley Research Center both for flow visualization and for density field determinations are described and tests in cryogenic flows at the Langley 0.3-Meter Transonic Cryogenic Tunnel are discussed. Experimental and theoretical fringe shift data are compared.

Burner, A. W.↗