Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Flow and Heat Transfer Experimental Study for 3D-Printed Solar Receiving Tubes With Helical Fins at Internal Surface

3D-printing technology was applied to fabricate novel solar thermal collection tubes that have internal heat transfer enhancement fins and external surfaces with high solar absorptivity and low emissivity due to the ability to use different materials in one tube. Helical fins were selected to introduce circumferential flow and thus minimize the circumferential temperature difference of the tube that receives sunlight on one side. The structures of the helical fins were previously optimized from computational fluid dynamics (CFD) analysis with the objective of low entropy production rate by looking for high heat transfer coefficient and relatively lower pressure loss. High-temperature alloy, Inconel-718, was used to 3D print the tubes, which can resist corrosion for the potential application of molten chloride salts as heat transfer fluid. Experimental tests were carried out using water as the heat transfer fluid with the high heat flux provided by a tubular furnace heater. The tested Reynolds number ranges from 3.9 × 10 3 to 6.1 × 10 4 . Heat transfer coefficients of up to 2.8 times that of the smooth tube could be obtained with the expense of increased pressure loss compared to that of the smooth tube. The total system entropy generation can be significantly reduced due to the benefit of heat transfer enhancement that is greater than the expenses of the increased pressure loss. The experimental results of the 3D-printed heat transfer tubes confirmed the CFD-based results of fin optimization. Furthermore, the novel heat transfer tube is recommended for application in concentrating solar power systems.

14 SOLAR ENERGY↗

Kelvin–Helmholtz instability under stabilizing parallel magnetic field in nonhomogeneous compressible MHD flows

We study the Kelvin–Helmholtz instability (KHI) for the general case of a compressible, nonhomogeneous, magnetized plasma flow. The study is limited to a vortex sheet interface with an imposed parallel magnetic field. We introduce a new formalism based on a convective Mach number M c , a convective Alfvénic Mach number M Ac , and a total convective Mach number that combines the two. We derive an analytic expression of the KHI growth rate for a homogeneous flow (i.e., zero Atwood number, A=0) that converges toward both the expression for unmagnetized compressible flow and Chandrasekhar's expression for magnetized incompressible flow. Otherwise, the dispersion relation is solved numerically and allows deriving general stability diagrams of magnetized KHI for the triplet (A, M c , β −plasma) parameters. We show these parameters uniquely define all configurations for a parallel magnetic field. We also construct diagrams with respect to the convective Alfvénic Mach number, the β − plasma parameter, or the magnetic field showing which magnetic field strength is required for stabilizing a given shear flow. The theoretical growth rates are compared with 18 simulations made with the GAMERA code, currently used for 3D magnetospheric simulations. Finally, we apply our results to the analysis of a past KHI experiment performed at the OMEGA laser facility, showing linear theory succeeds to provide accurate estimates of the growth rate at early times. We further discuss how our results can inform future experiments in the high-Mach magnetized regime at the National Ignition Facility. Possible limitations of the study due to resistive, mixing, or turbulence effects are discussed.

compressible flows↗

A High-Efficient Solution for Electro-Hydraulic Actuators with Energy Regeneration Capability

This paper proposes a cost-effective, robustly practical solution for a high-efficient electro-hydraulic actuator (EHA) for linear drives. The solution addresses the challenges of high costs and limited efficiency that limit the application of EHA for the electrification of many off-road vehicles. Based on a variable-speed electric motor and a low-cost technology for a fixed-displacement pump, the proposed solution is suitable for a compact implementation and it is capable of energy regeneration under overrunning load conditions. Two different architectures—an open circuit and a closed circuit one—are considered to determine the most practical and efficient configuration as well as the control features. Both architectures minimize throttling losses associated with the conventional regulation of hydraulic actuators. Actuator velocities below the minimum and beyond the maximum allowable pump flow rate are achieved in both architectures using a proportional valve that bypasses the pump flow. The paper describes the design methodology as well as the simulation and experimental activities performed to verify the control strategies as well as energy efficiency. Considering an EHA system of about 20 kW, a complete efficiency map of the system is determined for all the possible four quadrants of operation thus including both resistive and overrunning loads, where energy recuperation is implemented. Simulation and experimental results show that the energy efficiency of the hydraulic systems can reach 84.7% in resistive phases. In assistive phases, the hydraulic system can recover up to 81.8% of the actuator energy. Here, the comparison between open-circuit and closed-circuit structures shows the advantages of the former in terms of energy efficiency. The proposed solution is suitable for electrified hydraulic actuation systems, in both industrial and mobile applications. With the advantages of the low cost of the hydraulic unit and high energy efficiency, it is particularly suitable for mobile applications such as construction machines, that are recently experiencing a significant electrification trend.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Combining complex flow manifold with three dimensional woven lattices as a thermal management unit

The present invention is directed to a manifold for directing cooling fluid and/or gas to a heat exchanger in a flow configuration designed to optimize heat transfer from the heat exchanger. The manifold can take many different forms such as a layered construction with distributed inlet paths, local outlet paths, a central collection changer and a path for fluid removal. The manifold can be formed from a metal, plastic, rubber, ceramic, or other heat resistant material known to or conceivable by one of skill in the art. The manifold can also be combined with any type of heat exchanger known to or conceivable by one of skill in the art to form a thermal management unit. To optimize overall properties such as low pressure drop, high heat transfer, and excellent temperature uniformity of the thermal management unit, the manifold can be graded, expanded and scaled as needed.

Hemker, Kevin J.↗

Spontaneous Symmetry–Breaking of Nonequilibrium Steady–States Caused by Nonlinear Electrical Transport

Negative differential resistance (NDR) in certain materials has been attributed to spontaneous emergence of symmetry-breaking electrical current density localization from a previously homogeneous distribution, which is postulated to occur due to the nonequilibrium thermodynamic force of minimization of entropy production. However, this phenomenon has not been quantitatively predicted based on intrinsic material properties and an applied electrical stimulus. Herein an instability criterion is derived for localization of current density and temperature from a thermal fluctuation in a parallel conductor model of a thin film that is subject to Newton's law of cooling. The conditions for steady–state electro-thermal localization is predicted, verifying a decrease in entropy production upon localization. Electro-thermal localization accompanied by a decrease of entropy production is confirmed in a multiphysics simulation of current flow in a thin film. The instability criterion predicts conditions for spontaneous current density localization, relating symmetry breaking fundamentally to dynamical instability via Local Activity theory.

36 MATERIALS SCIENCE↗

Effect of Lateral Conduction in a Rectangular Fuel Plate and Optimum Stripe Widths for the OPAL Reactor

The impetus for this work is the Proliferation Resistance Optimization (PRO-X) program, which was created by the National Nuclear Security Administration (NNSA) of the US Department of Energy (DOE) to provide a framework for developing reactor designs that minimize the production of special nuclear materials while maximizing performance for peaceful uses. The Argentine company INVAP and Argonne National Laboratory collaborated to share knowledge and expertise regarding the thermal analysis of research reactors. Working together, they designed a series of test problems based on the Open Pool Australian Light Water (OPAL) reactor, whose fuel is in the form of flat plates cooled by water flowing through narrow rectangular channels. ANL used their PLTEMP/ANL code. INVAP used their TERMIC code (and its new multi-plate version, TERMIC-MP). Then, INVAP and ANL compared the two sets of results. 1-D models were used during the collaboration since for research reactor analysis, largely 1-D thermal-hydraulics models are commonly used because they are simple to apply and technically defendable. The collaboration between the two organizations aims for improvements in thermal-hydraulic models. Improvements to methods and models can reduce modeling uncertainties and excessive conservatism, allowing greater reactor performance without reducing predicted safety margins. Therefore, these improvements potentially expand the design space, making additional designs feasible, which, in turn, may achieve better fuel utilization and proliferation resistance in the designs. This report provides justification for the lateral node size (stripe width) chosen for the 1-D computer models during the collaboration. The lateral heat conduction in OPAL fuel plates is evaluated using the two-dimensional conduction capability of PLTEMP/ANL to determine a representative hot-stripe width that can be conservatively used for one-dimensional steady-state thermal-hydraulic analysis. Basically, a representative hot-stripe width needs to be selected so that the actual heat flux averaged over this stripe width is greater than or equal to the maximum heat flux obtained by the two-dimensional analysis. Detailed results in this report show that a hot-stripe width of 8.125 mm can be conservatively used for the one-dimensional thermal-hydraulics analysis of all plates. Therefore, eight equal stripes (8.125 mm each) are recommended to be modeled in the MCNP and PLTEMP/ANL full core models of the OPAL reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Revisiting Theoretical Limits for One Degree-of-Freedom Wave Energy Converters

This work revisits the theoretical limits of one degree-of-freedom wave energy converters (WECs). This work considers the floating sphere used in the OES Task 10 WEC modeling and verification effort for analysis. Analytical equations are derived to determine bounds on displacement amplitude, time-averaged power (TAP), and power-take-off (PTO) force. A unique result found shows that the TAP absorbed by a WEC can be defined solely by the inertial properties and radiation hydrodynamic coefficients. In addition, a unique expression for the PTO force was derived that provides lower and upper bounds when resistive control is used to maximize power generation. For complex conjugate control, this same expression only provides a lower bound, as there is theoretically no upper bound. These bounds assist in comparing the performance of the floating sphere if it were to extract energy using surge or heave motion. The analysis shows because of differences in hydrodynamic coefficients for each oscillating mode, there are different frequency ranges that provide better power capture efficiency. The influence of a motion constraint on TAP while utilizing a nonideal power take-off is examined and found to reduce the losses associated with bidirectional energy flow. The expression to calculate TAP with a nonideal PTO is modified by the electrical conversion efficiency and the ratio of the PTO spring and damping coefficients. Furthermore, the PTO spring and damping coefficients were separated in the expression, allowing for limits to be set on the PTO coefficients to ensure net power generation.

16 TIDAL AND WAVE POWER↗

Autoclave grid-to-rod fretting wear evaluation of a candidate cladding coating for accident-tolerant fuel

In pressurized water reactors (PWRs), water flow induced vibrations cause contact and rubbing between the fuel rods and the supporting grid, a phenomenon known as Grid-to-Rod-Fretting (GTRF). GTRF may produce progressive wear damage on the fuel claddings leading to subsequent leakage of radioactive fission products. Various accident-tolerant fuel (ATF) concepts are being developed for higher resistance to the high temperature steam and one approach is to apply a cladding coating. Here, fretting wear behavior of a candidate Cr-coating was investigated using a unique bench-scale autoclave testing rig mimicking the environment in an industrial full-assembly PWR simulator. The contact was under a realistically low load (~0.5 N) lubricated by deionized water at a temperature of 204 °C under a pressure of 20-23 bars. Results demonstrated that the Cr-coating significantly improved the cladding's wear resistance when tested against a commercial ZIRLO grid with or without pre-oxidization. In addition, the Cr-coating also reduced wear on the non-oxidized ZIRLO grid but slightly increased the wear on the pre-oxidized grid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fielding and analyzing performance of a prototype high voltage output gas switch for Saturn

Timing spread between the thirty-six Saturn modules affects peak electrical power delivered to the Bremsstrahlung diode and can affect vacuum power flow and impedance behavior of the load. To reduce the module spread, a new megavolt gas-insulated closing switch was developed employing design techniques developed for the Z-machine laser triggered switches while retaining Saturn’s simpler electrical triggering. Two modules were temporarily outfitted with the new switches and used separately into local resistive loads (instead of the usual Saturn electron beam load). A reliable operating point and switch time jitter at that point were the goals of the experiments. The target switch reliability is less than one pre-fire in one thousand switch-shots, and a timing standard deviation of 4 nanoseconds. The switches were able to meet both requirements but the number of tests at the chosen point are limited.

43 PARTICLE ACCELERATORS↗

Low global warming potential (GWP) refrigerant supermarket refrigeration system modeling and its application

As an environmentally friendly low global warming potential (GWP) refrigerant, Carbon dioxide (CO 2 ) has continuously gained popularity and research attention as alternative refrigerant for supermarket refrigeration system. In this paper, to fulfill the increasing need of accurate Low-GWP supermarket refrigeration models for development of supervisory level control and optimization strategies, a high fidelity model is developed for CO 2 transcritical supermarket refrigeration system which includes compressor rack of low temperature (LT) compressors and medium temperature (MT) compressors, air-cooled gas cooler, evaporator, expansion valves and other auxiliary equipment. A resistance-capacity model structure is proposed to simulate the display cases. Semi-thermodynamic models are proposed to estimate reciprocating compressors volumetric efficiency and power consumption. Furthermore the zone modeling approach is used for evaporator simulation, and air-cooled gas cooler is modeled with distributed modeling method. The expansion valve simulation is based on orifice flow model. To calibrate these models, both manufacture performance data and experimental data are used. The experiments are conducted with a full instrumental CO 2 supermarket refrigeration system installed in Oak Ridge National Lab Flexible Research Platform (FRP). The simulation model can predict the system performance, including power consumption, cooling capacity, mass flow rate, temperature, and pressure, with high accuracy (within ±4%) compared to experimental data. In addition, this developed model has been used to create the system optimum high side pressure for high side expansion valve control, and to generate wide operating range simulation data for developing the batter-equivalent commercial refrigeration system model which can be used in grid interactive control development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrically Conductive Amine Functionalized Reduced Graphite Oxide Foam for CO 2 Removal from the Air

Rapid regeneration of CO 2 adsorbents is critical to improving the productivity of direct air capture (DAC) systems. In this study, we codesigned a material to have appropriate electrical conductivity and CO 2 adsorption properties to enable efficient CO 2 capture from air. Specifically, we present a poly(ethylenimine) (PEI)-impregnated thermally annealed graphite oxide (TAGO900) foam adsorbent tailored for vacuum-assisted electrically driven thermal swing adsorption (V-ETSA). This structured adsorbent leverages the high electrical conductivity of the reduced graphite oxide framework to enable fast and direct heating of the adsorbent material by electrical resistance heating (Joule heating). An optimal sample, 40 wt % PEI (molecular weight 25k) impregnated TAGO900, shows the best balance between adsorption capacity (1.54 mmol g –1 ) and adsorption rates (0.016 mmol g –1 min –1 ) using fixed bed breakthrough experiments at 25 °C and 70% RH using 50 sccm 400 ppm of CO 2 /N 2 flow. Compared to conventional temperature vacuum swing adsorption (TVSA), the V-ETSA approach achieves substantially faster CO 2 desorption, achieving average desorption rates (including cooling time) of 0.09 mmol g –1 min –1 ─approximately 2.5 times faster than TVSA under similar operating conditions. The maximum desorption rate reaches 0.23 mmol/g/min during the desorption stage. These results underscore the importance of the direct heating strategy, such as Joule heating, for fast and highly productive vacuum swing adsorption in DAC systems.

amines↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Attaining regularization length insensitivity in phase-field models of ductile failure

In this work, a cohesive phase-field model of ductile fracture in a finite-deformation setting is presented. The model is based on a free-energy function in which both elastic and plastic work contributions are coupled to damage. Using a strictly variational framework, the field evolution equations, damage kinetics, and flow rule are jointly derived from a scalar least-action principle. Particular emphasis is placed on the use of a rational function for the stress degradation that maintains a fixed effective strength with decreasing regularization length. The model is employed to examine crack growth in pure mode-I problems through the generation of crack growth resistance (J-R) curves. In contrast to alternative models, the current formulation gives rise to J-R curves that are insensitive to the regularization length. Numerical evidence suggests convergence of local fields with respect to diminishing regularization length as well.

42 ENGINEERING↗

Effective removal of trace-level toxic metals from flue gas desulfurization wastewater using SiO 2 supported hydrogel sorbent

Flue gas desulfurization (FGD) wastewater generated from coal-fired power plants contain potentially harmful heavy metal pollutants that pose a threat to public health and clean water. In this work, we present a water stable polyethylenimine-n,n’-methylenebisacrylamide (PEI-MBAA) functionalized SiO 2 solid sorbent material (PMS-1.2/1/4) and investigate its metal adsorption kinetics, selectivity, regenerability, and space velocity. The kinetic studies of six of the toxic heavy metals (As, Cd, Cr, Pb, Se, and Hg) prepared with single elements in Milli-Q water showed the effect of chemical bonding and intraparticle mass transfer resistance on the sorption process. The selectivity studies demonstrated the significant adsorption efficiency toward trace-level heavy metals (Se, Cd, U, Al, etc.) from authentic industrial FGD wastewater. Through five consecutive adsorption–desorption cycles with the FGD (uptake)-citrate (release)-based buffer pair, the sorbent showed high heavy metal removal ability and good reusability. The maximum flow rate for the removal of Se from industrial FGD wastewater was determined to be as high as 8 bed volumes/minute of the sorbent bed. Finally, the results demonstrate the PMS-1.2/1.4 sorbent is a promising candidate for the removal of heavy metals from practical aqueous solutions.

36 MATERIALS SCIENCE↗

Measurement of Local Impedance Characteristics of In-Plane PEM Electrolyzer Component Features via Segmented Cell

Segmented cells are a class of advanced diagnostic devices that enable the measurement of current distribution within the active area of an electrochemical cell, allowing for the evaluation of localized impacts from operating conditions, flow fields and component inhomogeneities. Segmented cell devices have been applied to support R&D efforts for the advancement of polymer electrolyte membrane fuel cell technologies and more recently proton exchange membrane water electrolysis (PEMWE). Beyond current density distributions, segmented cells have been successfully deployed to collect the distribution of other relevant parameters such as high frequency resistance and electrode potentials. Very recently, a promising impedance method has been reported for water electrolysis where a one-dimensional segmented cell is coupled to a multichannel potentiostat, to enable the measurement of local cell impedances, further expanding the diagnostic capabilities of the segmented cell. In this study, we will present recent efforts to accurately measure local impedance characteristics for a PEMWE cell using a two-dimensional segmented cell device coupled with a multichannel potentiostat. The distribution of local resistances, i.e. high frequency, charge transfer, mass transport and catalyst layer, and iR-free overpotentials were successfully measured after eliminating sources of random and systematic error. We will discuss the application of this diagnostic on a cell containing a 1 cm feature simulating an ionomer skin. The results from these tests give insights if such an irregularity needs to be classified as a defect, and highlight the usefulness of coupling impedance spectroscopy with segmented cells for holistic spatial diagnostics of electrochemical devices.

08 HYDROGEN↗

Nanowire-Based Materials as Coke-Resistant Catalyst Supports for Dry Methane Reforming

In this paper, nanowire-supported catalysts loaded with nickel are shown to be coke resistant compared to nanoparticle-supported catalysts. Specifically, Ni-loaded titania-based nanowire catalysts were tested with the dry methane reforming process in a laboratory-scale continuous packed-bed atmospheric reactor. The CO 2 conversion rate stayed above 90% for over 30 h on stream under coke-promoting conditions, such as high flow rates, low temperatures, and a high ratio of CH 4 to CO 2 . The coke (C x H y , x>>y) on the spent catalyst surface for both nanowire- and nanoparticle-supported catalysts was characterized by TGA, temperature-programmed reduction (TPR), and electron microscopy (SEM/TEM/EDS), and it was revealed that the types of carbon species present and their distribution over the morphology-enhanced materials played a major role in the deactivation. The CO 2 conversion activity of Ni supported on titania nanoparticles was reduced from ~80% to less than 72% in 30 h due to the formation of a graphitic coke formation. On the other hand, Ni particles supported on nanowires exhibited cube-octahedral morphologies, with a high density of non- (111) surface sites responsible for the increased activity and reduced graphitic coke deposition, giving a sustained and stable catalytic activity during a long time-on-stream experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical investigation of braking of tearing mode rotation by resistive walls in ITER

The locking of the 2/1 tearing mode to the resistive wall in the ITER tokamak (15 MA inductive scenario 2) is investigated theoretically using a cylindrical asymptotic matching model. The model takes into account the fact that ITER plasmas will effectively be surrounded by two walls; the inner blanket module layer with a time constant of about 23 ms, and the outer vacuum vessel with a time constant of about 380 ms. The model also takes cognizance of the fact that neither the blanket module layer nor the vacuum vessel can be accurately described as “thin” walls (in the ordinarily accepted sense). The model incorporates changes in both the plasma poloidal and the toroidal angular velocity profiles, in response to the electromagnetic braking torque that develops at the rational surface, because it turns out that neoclassical poloidal flow-damping is not strong enough to completely suppress changes in the poloidal velocity. Finally, the model accurately calculates changes in the poloidal and toroidal plasma angular velocity profiles by evolving the full angular equations of motion, taking the electromagnetic braking torque, plasma inertia, plasma viscosity, and poloidal flow-damping into account. The time required for the 2/1 tearing mode to grow from a small amplitude to a sufficient one to lock to the walls is found to be about 3.5 s. As a result, the critical full radial island width at which wall locking is triggered is found to be about 9% of the plasma minor radius.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utilizing integrated neutron diffraction and elastoplastic self-consistent crystal plasticity model to quantitatively assess the strengthening mechanism in Al–12.5Ce and Al–12.5Ce–0.4Mg alloys

An integrated in-situ neutron diffraction and elastic plastic self-consistent crystal plasticity (EPSC-CP) modeling scheme is performed on a binary Al–12Ce alloy and a ternary Al–12Ce–0.4Mg alloys. Using this scheme, the constitutive parameters, i.e. elastic constants and slip system parameters of individual phases can be calibrated which can be used in microstructure-based CP models to predict materials performance. From this study, it is shown that the elastic constants of Al 11 Ce 3 intermetallics calculated from density function theory calculation in the literature are rather accurate. When applied to the EPSC-CP model, the lattice strains of both the binary and ternary alloys are correctly predicted as compared with experiments, and large lattice strain differences between Al (100) plane and Al 11 Ce 3 (010) plane are demonstrated. The slip system parameters calibrated by the scheme shows that the addition of 0.4 wt% Mg in the alloy has little influence on the critical resolved shear stress of initial dislocation glide in the Al matrix which caused plastic yield in the material. This can be explained by the very dilute Mg solute content in the Al solid solution, causing large spacing of Al–Mg lattice misfit sites and little impact on resistance of dislocation glide at initial yield. The 0.4 wt% Mg addition, on the other hand, has a large influence on the hardening term in the slip system parameters, indicating those Al–Mg misfit sites do help dislocation accumulation during the deformation. The impact of dilute Mg addition on the Al slip system parameters is also reflected in the flow behavior of the ternary alloy: little impact on the yield stress, but a large impact on working hardening and tensile strength of the materials which is consistent with the literature.

36 MATERIALS SCIENCE↗