Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fractionalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

X-RAY CONSTRAINTS ON THE LOCAL SUPERMASSIVE BLACK HOLE OCCUPATION FRACTION

Distinct seed formation mechanisms are imprinted upon the fraction of dwarf galaxies currently containing a central supermassive black hole. Seeding by Population III remnants is expected to produce a higher occupation fraction than is generated with direct gas collapse precursors. Chandra observations of nearby early-type galaxies can directly detect even low-level supermassive black hole activity, and the active fraction immediately provides a firm lower limit to the occupation fraction. Here, we use the volume-limited AMUSE surveys of ∼200 optically selected early-type galaxies to characterize simultaneously, for the first time, the occupation fraction and the scaling of L {sub X} with M {sub star}, accounting for intrinsic scatter, measurement uncertainties, and X-ray limits. For early-type galaxies with M {sub star} < 10{sup 10} M {sub ☉}, we obtain a lower limit to the occupation fraction of >20% (at 95% confidence), but full occupation cannot be excluded. The preferred dependence of log L {sub X} upon log M {sub star} has a slope of ∼0.7-0.8, consistent with the ''downsizing'' trend previously identified from the AMUSE data set, and a uniform Eddington efficiency is disfavored at ∼2σ. We provide guidelines for the future precision with which these parameters may be refined with larger or more sensitive samples.

79 ASTRONOMY AND ASTROPHYSICS↗

Mass dependence of halo baryon fractions from the kinetic Sunyaev–Zeldovich effect

ABSTRACT We detect the kinetic Sunyaev–Zeldovich imprint of peculiar motions of galaxy groups and clusters, using the photometric Dark Energy Spectroscopic Instrument Legacy Surveys together with cosmic microwave background (CMB) maps from the Atacama Cosmology Telescope (ACT). We develop a comprehensive forward model based on the AbacusSummit cosmological simulations: Mock galaxy group catalogues and synthetic kinetic Sunyaev–Zeldovich (kSZ) maps are generated, together with a reconstructed peculiar velocity field that allows for photo-z errors, redshift-space distortions, and survey masks. We investigate possible contamination from the cosmic infrared background (CIB), finding that CIB effects are subdominant to the kSZ signal in the relevant ACT frequency channel. We then predict the kSZ signal expected when stacking CMB temperature maps around groups, taking account of their estimated radial velocities. Comparing the model with observations, we are able to constrain the total baryon fraction within haloes, as well as their internal gas profiles. We find evidence for mass dependence of the halo baryon fraction within the virial radius. The gas fraction in massive groups is consistent with the universal baryon fraction, but low-mass groups ($10^{12.5} \lesssim M\, /\, h^{-1}\, \mathrm{M}_\odot \lesssim 10^{14}$) are depleted to $0.38 \pm 0.11$ times the universal baryon fraction. We find this low virial baryon fraction to be consistent with an extended gas profile, for which the total baryon content reaches the universal value well beyond the virial radius. This conclusion is consistent with previous analyses using X-ray, kSZ, and weak lensing, and plausibly reflects energetic feedback processes from the galaxies in these haloes.

Roper, Finn A [Institute for Astronomy, University↗

Measurement of 𝐵 meson production fraction ratios in proton-proton collisions at √𝑠 = 13 TeV using open-charm and charmonium decays

Production fraction ratios of 𝐵 + , 𝐵 0 , and 𝐵$^{0}_{𝑠}$ mesons are measured in proton-proton collisions at √𝑠 = 13 TeV using a special dataset recorded in 2018 with high-rate triggers designed to collect an unbiased sample of 1⁢010 𝑏 hadrons with the CMS experiment at the LHC. These data allow the study of the open-charm decays of 𝐵 mesons (𝐵 (𝑠) → 𝜋⁢𝐷 (𝑠) ) where the 𝐷 meson decays into fully hadronic final states. By utilizing known branching fractions and precise theoretical calculations, production fraction ratios as functions of 𝐵 meson transverse momentum (𝑝 T ) and rapidity (𝑦) are measured using open-charm decays in the kinematic range of 8 < 𝑝 T < 60 GeV and |𝑦| <2.25. In addition, the same dataset is used to measure the relative production fraction ratios with the charmonium decay channels [𝐵 (𝑠) →𝑋⁢𝐽/𝜓 with 𝑋 indicating a 𝐾 + , 𝐾*(892) 0 , or 𝜙⁡(1020) meson] where the 𝐽/𝜓 meson decays into a pair of muons. The open-charm results are used to normalize the relative production fraction ratios obtained from the charmonium samples. Measurements of the ratios of branching fractions of 𝐵 meson decays to charmonium and open-charm final states are also reported, which will improve the world-average values of these ratios. Finally, we test isospin invariance in 𝐵 meson production in proton-proton collisions and observe that it holds within the experimental precision.

Bottom mesons↗

Quantum Liquid with Deconfined Fractional Excitations in Three Dimensions

Excitations which carry 'fractional' quantum numbers are known to exist in one dimension in polyacetylene, and in two dimensions, in the fractional quantum Hall effect. Fractional excitations have also been invoked to explain the breakdown of the conventional theory of metals in a wide range of three-dimensional materials. However, the existence of fractional excitations in three dimensions remains highly controversial. In this Letter we report direct numerical evidence for the existence of an extended quantum liquid phase supporting fractional excitations in a concrete, three-dimensional microscopic model--the quantum dimer model on a diamond lattice. We demonstrate explicitly that the energy cost of separating fractional monomer excitations vanishes in this liquid phase, and that its energy spectrum matches that of the Coulomb phase in (3+1)-dimensional quantum electrodynamics.

36 MATERIALS SCIENCE↗

Three independent one-dimensional margins for single-fraction frameless stereotactic radiosurgery brain cases using CBCT

Purpose: Setting a proper margin is crucial for not only delivering the required radiation dose to a target volume, but also reducing the unnecessary radiation to the adjacent organs at risk. This study investigated the independent one-dimensional symmetric and asymmetric margins between the clinical target volume (CTV) and the planning target volume (PTV) for linac-based single-fraction frameless stereotactic radiosurgery (SRS).Methods: The authors assumed a Dirac delta function for the systematic error of a specific machine and a Gaussian function for the residual setup errors. Margin formulas were then derived in details to arrive at a suitable CTV-to-PTV margin for single-fraction frameless SRS. Such a margin ensured that the CTV would receive the prescribed dose in 95% of the patients. To validate our margin formalism, the authors retrospectively analyzed nine patients who were previously treated with noncoplanar conformal beams. Cone-beam computed tomography (CBCT) was used in the patient setup. The isocenter shifts between the CBCT and linac were measured for a Varian Trilogy linear accelerator for three months. For each plan, the authors shifted the isocenter of the plan in each direction by ±3 mm simultaneously to simulate the worst setup scenario. Subsequently, the asymptotic behavior of the CTV V{sub 80%} for each patient was studied as the setup error approached the CTV-PTV margin.Results: The authors found that the proper margin for single-fraction frameless SRS cases with brain cancer was about 3 mm for the machine investigated in this study. The isocenter shifts between the CBCT and the linac remained almost constant over a period of three months for this specific machine. This confirmed our assumption that the machine systematic error distribution could be approximated as a delta function. This definition is especially relevant to a single-fraction treatment. The prescribed dose coverage for all the patients investigated was 96.1%± 5.5% with an extreme 3-mm setup error in all three directions simultaneously. It was found that the effect of the setup error on dose coverage was tumor location dependent. It mostly affected the tumors located in the posterior part of the brain, resulting in a minimum coverage of approximately 72%. This was entirely due to the unique geometry of the posterior head.Conclusions: Margin expansion formulas were derived for single-fraction frameless SRS such that the CTV would receive the prescribed dose in 95% of the patients treated for brain cancer. The margins defined in this study are machine-specific and account for nonzero mean systematic error. The margin for single-fraction SRS for a group of machines was also derived in this paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Verification of Gamma Knife extend system based fractionated treatment planning using EBT2 film

Purpose: This paper presents EBT2 film verification of fractionated treatment planning with the Gamma Knife (GK) extend system, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery.Methods: A human head shaped phantom simulated the verification process for fractionated Gamma Knife treatment. Phantom preparation for Extend Frame based treatment planning involved creating a dental impression, fitting the phantom to the frame system, and acquiring a stereotactic computed tomography (CT) scan. A CT scan (Siemens, Emotion 6) of the phantom was obtained with following parameters: Tube voltage—110 kV, tube current—280 mA, pixel size—0.5 × 0.5 and 1 mm slice thickness. A treatment plan with two 8 mm collimator shots and three sectors blocking in each shot was made. Dose prescription of 4 Gy at 100% was delivered for the first fraction out of the two fractions planned. Gafchromic EBT2 film (ISP Wayne, NJ) was used as 2D verification dosimeter in this process. Films were cut and placed inside the film insert of the phantom for treatment dose delivery. Meanwhile a set of films from the same batch were exposed from 0 to 12 Gy doses for calibration purposes. An EPSON (Expression 10000 XL) scanner was used for scanning the exposed films in transparency mode. Scanned films were analyzed with inhouse written MATLAB codes.Results: Gamma index analysis of film measurement in comparison with TPS calculated dose resulted in high pass rates >90% for tolerance criteria of 1%/1 mm. The isodose overlay and linear dose profiles of film measured and computed dose distribution on sagittal and coronal plane were in close agreement.Conclusions: Through this study, the authors propose treatment verification QA method for Extend frame based fractionated Gamma Knife radiosurgery using EBT2 film.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-90: Concrete Forward-Scatter Fractions for Radiotherapy Shielding Applications

Purpose: There is little instruction within the primary shielding guidance document NCRP 151 for vault designs where the primary beam intercepts the maze. We have conducted a Monte-Carlo study to characterize forward-scattered radiation from concrete barriers with the intent of quantifying what amount of additional shielding outside the primary beam is needed in this situation. Methods: We reproduced our vault in MCNP 5 and simulated spectra obtained from the literature and from our treatment planning system for 10 and 18 MV beams. Neutron and gamma-capture contributions were not simulated. Energy deposited was scored at isocenter in a water phantom, within various cells that comprised the maze, and within cells that comprised the vault door. Tracks were flagged that scattered from within the maze to the door and their contributions were tallied separately. Three different concrete mixtures found in the literature were simulated. An empirically derived analytic equation was used for comparison, utilizing patient scatter fractions to approximate the scatter from concrete. Results: Our simulated data confirms that maze-scattered radiation is a significant contribution to total photon dose at the door. It contributes between 20-35% of the photon shielding workload. Forward-scatter fractions for concrete were somewhat dependent on concrete composition and the relative abundance of higher-Z elements. Scatter fractions were relatively insensitive to changes in the primary photon spectrum. Analytic results were of the same magnitude as simulated results. Conclusions: Forward-scattered radiation from the maze barrier needs to be included in the photon workload for shielding calculations in non-standard vault designs. Scatter fractions will vary with concrete composition, but should be insensitive to spectral changes between machine manufacturers. Further plans for investigation include refined scatter fractions for various concrete compositions, scatter fraction measurement, and simulation of photo-nuclear interaction within the maze barrier for high-energy beams.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-292: Sensitivity of Fractionated Lung IMPT Treatments to Setup Uncertainties and Motion Effects

Purpose: Evaluate the sensitivity of intensity-modulated proton therapy (IMPT) lung treatments to systematic and random setup uncertainties combined with motion effects. Methods: Treatment plans with single-field homogeneity restricted to ±20% (IMPT-20%) were compared to plans with no restriction (IMPT-full). 4D Monte Carlo simulations were performed for 10 lung patients using the patient CT geometry with either ±5mm systematic or random setup uncertainties applied over a 35 × 2.5Gy(RBE) fractionated treatment course. Intra-fraction, inter-field and inter-fraction motions were investigated. 50 fractionated treatments with systematic or random setup uncertainties applied to each fraction were generated for both IMPT delivery methods and three energy-dependent spot sizes (big spots - BS σ=18-9mm, intermediate spots - IS σ=11-5mm, small spots - SS σ=4-2mm). These results were compared to a Monte Carlo recalculation of the original treatment plan, with results presented as the difference in EUD (ΔEUD), V{sub 95} (ΔV{sub 95}) and target homogeneity (ΔD{sub 1}–D{sub 99}) between the 4D simulations and the Monte Carlo calculation on the planning CT. Results: The standard deviations in the ΔEUD were 1.95±0.47(BS), 1.85±0.66(IS) and 1.31±0.35(SS) times higher in IMPT-full compared to IMPT-20% when ±5mm systematic setup uncertainties were applied. The ΔV{sub 95} variations were also 1.53±0.26(BS), 1.60±0.50(IS) and 1.38±0.38(SS) times higher for IMPT-full. For random setup uncertainties, the standard deviations of the ΔEUD from 50 simulated fractionated treatments were 1.94±0.90(BS), 2.13±1.08(IS) and 1.45±0.57(SS) times higher in IMPTfull compared to IMPT-20%. For all spot sizes considered, the ΔD{sub 1}-D{sub 99} coincided within the uncertainty limits for the two IMPT delivery methods, with the mean value always higher for IMPT-full. Statistical analysis showed significant differences between the IMPT-full and IMPT-20% dose distributions for the majority of scenarios studied. Conclusion: Lung IMPT-full treatments are more sensitive to both systematic and random setup uncertainties compared to IMPT-20%. This work was supported by the NIH R01 CA111590.

60 APPLIED LIFE SCIENCES↗

SU-E-T-653: Quantifying Inter-Fraction Range Uncertainty for Input Into Robust Proton Planning

Purpose: To provide a method for quantifying centre- and tumour site-specific population range uncertainty due to inter-fraction motion for use within robust proton planning and plan analysis. PTV-based and probabilistic/robust plans depend upon accurate knowledge of geometric and range uncertainties. If the uncertainty model is inaccurate, both types of plan, PTV or probabilistic, could produce under-dosing of the target and/or overdosing of OAR. Methods: Daily mega-voltage volumetric imaging data from previously treated radiotherapy patients has been used to investigate inter-fraction changes to water equivalent path-length (WEPL). Daily image-guidance scans were carried out for each patient and corrected for changes in CTV position (using rigid transformations). An effective depth algorithm was used to determine residual range changes, after corrections were applied, by comparing WEPL within the CTV at each fraction for several beam angles. This method has been demonstrated for nine prostate and seven head and neck. Results: Inter-fraction range changes for the head and neck patient sample were Σ=3.39mm, σ=4.72mm and overall mean =−1.82mm; for prostate Σ=5.64mm, σ=5.91mm and overall mean =0.98 mm. The choice of beam angle for head and neck did not affect the inter-fraction range error significantly; however this was not the same for prostate. Greater range changes were seen using a lateral beam compared to an anterior beam for prostate due to relative motion of the prostate and femoral heads. Conclusion: A method has been developed to quantify population range changes due to inter-fraction motion. The results show a non-zero mean for these samples, as well as significant Σ and σ, highlighting the importance of quantifying uncertainties and use of image guidance. Such information can be used in robust optimisation algorithms and for analysing treatment plan robustness. It may also help in establishing beam start conditions at planning and for establishing adaptive planning protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-02: Estimation of Radiobiological Doses (BED and EQD2) of Single Fraction Electronic Brachytherapy That Equivalent to I-125 Eye Plaque: By Using Linear-Quadratic and Universal Survival Curve Models

Purpose: To test the radiobiological impact of hypofractionated choroidal melanoma brachytherapy, we calculated single fraction equivalent doses (SFED) of the tumor that equivalent to 85 Gy of I125-BT for 20 patients. Corresponding organs-at-risks (OARs) doses were estimated. Methods: Twenty patients treated with I125-BT were retrospectively examined. The tumor SFED values were calculated from tumor BED using a conventional linear-quadratic (L-Q) model and an universal survival curve (USC). The opposite retina (α/β = 2.58), macula (2.58), optic disc (1.75), and lens (1.2) were examined. The % doses of OARs over tumor doses were assumed to be the same as for a single fraction delivery. The OAR SFED values were converted into BED and equivalent dose in 2 Gy fraction (EQD2) by using both L-Q and USC models, then compared to I125-BT. Results: The USC-based BED and EQD2 doses of the macula, optic disc, and the lens were on average 118 ± 46% (p < 0.0527), 126 ± 43% (p < 0.0354), and 112 ± 32% (p < 0.0265) higher than those of I125-BT, respectively. The BED and EQD2 doses of the opposite retina were 52 ± 9% lower than I125-BT. The tumor SFED values were 25.2 ± 3.3 Gy and 29.1 ± 2.5 Gy when using USC and LQ models which can be delivered within 1 hour. All BED and EQD2 values using L-Q model were significantly larger when compared to the USC model (p < 0.0274) due to its large single fraction size (> 14 Gy). Conclusion: The estimated single fraction doses were feasible to be delivered within 1 hour using a high dose rate source such as electronic brachytherapy (eBT). However, the estimated OAR doses using eBT were 112 ∼ 118% higher than when using the I125-BT technique. Continued exploration of alternative dose rate or fractionation schedules should be followed.

60 APPLIED LIFE SCIENCES↗

SU-F-T-516: Effects of Inter-Fraction Organ Displacement/deformation On the Delivered Doses to the Heart, Esophagus, and Lungs in Patients Receiving Thoracic Radiotherapy

Purpose: To quantitatively assess the effects of inter-fraction changes in organ shape and location on the delivered dose distribution to the organs at risk (OAR) in lung cancer patients. Methods: This study analyzes treatment data of 10 patients, who were treated to 60Gy in 30 fractions. In each fraction a cone beam CT (CBCT) was acquired. Each CBCT was registered with the planning CT using deformable registration tools within MIM Software. The daily setup shifts were used to translate the planned dose distribution on the deformed planning CT. The structures of lungs, esophagus and heart were re-delineated by a physician on each CBCT. The doses delivered to each OAR, reflecting changes in the position and shape variations, were recomputed. Resultant daily dose volume histograms (DVHs) for OARs were computed and compared to those from the planning CT. Results: Based on the findings of two patients and 24 CBCTs analyzed so far, higher doses are delivered to the lungs and esophagus compared to the treatment plan. The dose differences per fraction between the delivered doses and those in the treatment plan are: for patient 1, lung mean dose = 5.3±1.3cGy and esophagus mean dose = 3.4±3.5cGy. For patient 2, lung mean dose = 12.0±3.9cGy and esophagus mean dose = 34.2±7.5cGy. Regarding the maximum dose to heart, the results varied (−18.9±22.0cGy for patient1 and 53.0±62.2cGy for patient2). Conclusion: The dosimetric effects of inter-fractional anatomical variations could be estimated using deformable image registration and manual organ segmentation for each CBCT. A considerable dose distribution variation between fractions was observed for the OARs. These changes are currently not taken into account while treating the patients and these may explain cases with severe side effects even when the treatment plan looks satisfactory. These results suggest the need for automated daily dose tracking and accumulation.

60 APPLIED LIFE SCIENCES↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 04: Assessment of intra-fraction motion during lung SABR VMAT using a custom abdominal compression device

Purpose: Lung SABR patients are treated using Volumetrically Modulated Arc Therapy (VMAT), utilizing 2 arcs with Conebeam CT (CBCT) image-guidance prior to each arc. Intra-fraction imaging can prolong treatment time (up to 20%), and the aim of this study is to determine if it is necessary. Methods: We utilize an in-house abdominal compression device to minimize respiratory motion, 4DCT to define the ITV, a 5 mm PTV margin and a 2–3 mm PRV margin. We treated 23 patients with VMAT, fifteen were treated to 48 Gy in 4 fractions, while eight were treated with up to 60 Gy in 8 fractions. Intrafraction motion was assessed by the translational errors recorded for the second CBCT. Results: There was no significant difference (t-test, p=0.93) in the intra-fraction motion between the patients treated with 4 and 8 fractions, or between the absolute translations in each direction (ANOVA, p=0.17). All 124 intra-fraction CBCT images were analysed and 95% remained localized within the 5 mm PTV margin The mean magnitude of the vector displacement was 1.8 mm. Conclusions: For patients localized with an abdominal compression device, the intrafraction CBCT image may not be necessary, if it is only the tumor coverage that is of concern, as the patients are typically well within the 5 mm PTV margin. On the other hand, if there is a structure with a smaller PRV margin, an intrafraction CBCT is recommended to ensure that the dose limit for the organ at risk is not exceeded.

60 APPLIED LIFE SCIENCES↗

Timescales of mafic magmatic fractionation documented by paleosecular variation in basaltic drill core, Snake River Plain volcanic province, Idaho, USA

Abstract The timescales over which fractional crystallization and recharge work in mafic volcano-plutonic provinces is subject to great uncertainty. Currently modeled processes are subject to the scale of measurement: monogenetic basaltic fields accumulate over hundreds of thousands of years, consistent with U-Th-Ra isotopic variations that imply 50% crystallization of basic magmas on timescales of 100,000 years or more, whereas crystal diffusion modeling implies phenocryst residence times of ~1–1000 years. Monogenetic basalts of the Snake River Plain in southern Idaho, USA, are up to 2 km thick and postdate passage over the Yellowstone–Snake River Plain hotspot. Detailed lithologic and geophysical logging of core from deep drill holes, along with chemical stratigraphy and high-resolution paleomagnetic inclination measurements, document individual eruptive units, compound lava flows, and basaltic flow groups that accumulated over 1–6 m.y. Hiatuses are commonly marked by loess or fluvial interbeds that vary from ~0.1 m thick to 20 m thick. Radiometric (40Ar-39Ar, detrital zircon U-Pb) and paleomagnetic timescale ages show that the deepest hole (Kimama drill hole, 1912 m total depth) accumulated over ~6 m.y. Cycles of fractional crystallization and recharge are recognized in the chemical stratigraphy as up-section shifts in major and trace elements; these fractionation cycles commonly represent 40%–50% fractionation. Individual fractionation cycles may comprise 20–40 eruptive units (8–17 lava flows) with little to no change in paleomagnetic inclination (0°–1°), whereas adjacent cycles may differ by several degrees from one another or reflect changes in polarity. Rates of paleosecular variation in Holocene lavas and sediments dated using 14C document significant shifts in magnetic inclination over short timescales, ranging from ~0.05° to 2°/decade, with an average of ~0.5°/decade and a minimum rate of 0.05°/decade. This implies that fractionation cycles with ≤1° variation in magnetic inclination formed on timescales of a few decades up to a few centuries (20–200 years). Thus, the lavas collectively represent only a few thousand years of eruptive activity, with major flow groups separated in time by tens to hundreds of thousands of years. We suggest that the rates defined by paleosecular variation capture the timescales of magmatic chamber evolution (fractionation/recharge) in the seismically imaged mid-crustal sill complex; in contrast, we suggest that crystal diffusion modeling captures the residence times in shallow subvolcanic magmatic chambers that underlie individual monogenetic volcanoes.

Geology↗

Fractional Quantum Anomalous Hall Effect

The realization of the fractional quantum anomalous Hall effect (FQAHE) in a zero-field fractional Chern insulator is a new advancement in condensed matter physics, resulting from the interplay among strong correlations, topology, and spontaneous time-reversal symmetry breaking in lattice systems. In this review, we highlight the experimental and theoretical progress toward achieving FQAHE in two material platforms: twisted bilayer MoTe 2 and rhombohedral-stacked multilayer graphene. These systems host narrow topological bands with nontrivial Chern numbers, enabling interaction-driven fractionalized states analogous to the fractional quantum Hall effect, but without external magnetic fields. We discuss how spontaneous ferromagnetism, moiré lattice reconstruction, and band topological effects underpin the emergence of FQAHE in twisted MoTe 2 . We describe experimental discoveries of zero-field fractional Chern insulators in both transport and optical experiments, as well as signatures of composite Fermi liquids and higher-energy Chern band, which may shed light on engineering nonabelian states. In rhombohedral graphene/hexagonal boron nitride moiré superlattices, we review the recent observations of fractionally quantized Hall resistance, connections between FQAHE and extended quantum anomalous Hall phases, and the coexistence of superconductivity and FQAHE. Furthermore, these discoveries not only deepen our understanding of strongly correlated topological matter but also open new frontiers for exploring nonabelian anyons, fault-tolerant quantum computation, and topological opto-spintronics free of magnetic fields.

bilayer↗

The extended auxiliary equation mapping method to determine novel exact solitary wave solutions of the nonlinear fractional PDEs

Abstract In this paper, some new nonlinear fractional partial differential equations (PDEs) have been considered.Three models are including the space-time fractional-order Boussinesq equation, space-time (2 + 1)-dimensional breaking soliton equations, and space-time fractional-order SRLW equation describe the behavior of these equations in the diverse applications. Meanwhile, the fractional derivatives in the sense of β -derivative are defined. Some fractional PDEs will convert to the considered ordinary differential equations by the help of transformation of β -derivative. These equations are analyzed utilizing an integration scheme, namely, the extended auxiliary equation mapping method. The different kinds of traveling wave solutions, solitary, topological, dark soliton, periodic, kink, and rational, fall out as a by-product of this scheme. Finally, the existence of the solutions for the constraint conditions is also shown. The outcome indicates that some fractional PDEs are used as a growing finding in the engineering sciences, mathematical physics, and so forth.

Engineering↗

Physico-chemical properties of lignin fractions from acid pretreated corn stover and their effects on enzymatic hydrolysis of microcrystalline cellulose

Lignin has been shown to be a recalcitrance factor in many biomass conversion studies. To better understand the effects of lignin on cellulose conversion, different lignin fractions were extracted from the same dilute acid pretreated corn stover by three sequential isolation methods, namely ethanol extraction, dioxane extraction, and enzyme purification. The physicochemical properties of each lignin fraction including molecular weight distribution, surface area, surface charge, and other structural features varied, depending on the isolation methods. All three lignin fractions had negative surface charges, and ethanol-extracted lignin carried the highest surface charges, followed by dioxane-extracted lignin and cellulase-purified residual lignin. These physicochemical properties of lignin fractions also resulted in different extent of inhibitory effects on enzymatic hydrolysis of microcrystalline cellulose (MCC). Dioxane-extracted lignin exhibited the highest inhibitory effect on glucose release from MCC, followed by the cellulase-purified residual lignin fraction and ethanol-extracted lignin. Furthermore, lignin fractions with higher contents of syringyl (S) substructure and β-O-4 aryl ether interunit linkages showed a stronger negative effect on cellulase hydrolysis of MCC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical Analysis of Fractional Viscoelastic Flow in Circular Pipes: General Solutions

Fractional calculus is a relatively old yet emerging field of mathematics with the widest range of engineering and biomedical applications. Despite being an incredibly powerful tool, it, however, requires promotion in the engineering community. Rheology is undoubtedly one of the fields where fractional calculus has become an integral part of cutting-edge research. There exists extensive literature on the theoretical, experimental, and numerical treatment of various fractional viscoelastic flows in constraint geometries. However, the general theoretical approach that unites several most commonly used models is missing. Here we present exact analytical solutions for fractional viscoelastic flow in a circular pipe. We find velocity profiles and shear stresses for fractional Maxwell, Kelvin–Voigt, Zener, Poynting–Thomson, and Burgers models. The dynamics of these quantities are studied with respect to normalized pipe radius, fractional orders, and elastic moduli ratio. Three different types of behavior are identified: monotonic increase, resonant, and aperiodic oscillations. The models developed are applicable in the widest material range and allow for the alteration of the balance between viscous and elastic properties of the materials.

Gritsenko, Dmitry (ORCID:0000000248181512)↗

The connection between reddening, gas covering fraction, and the escape of ionizing radiation at high redshift

Using a large sample of spectroscopically confirmed z∼3 galaxies, we establish an empirical relationship between reddening (E(B−V)), neutral gas covering fraction (f{sub cov}(H I)), and the escape of ionizing (Lyman continuum, LyC) photons. Our sample includes 933 galaxies at z∼3,121 of which have deep spectroscopic observations (≳7 hr) at 850≲λ{sub rest}≲1300 Å with the Low Resolution Imaging Spectrograph on Keck. The high covering fraction of outflowing optically thick H I indicated by the composite spectra of these galaxies implies that photoelectric absorption, rather than dust attenuation, dominates the depletion of LyC photons. By modeling the composite spectra as the combination of an unattenuated stellar spectrum including nebular continuum emission with one that is absorbed by H I and reddened by a line-of-sight extinction, we derive an empirical relationship between E(B−V) and f{sub cov}(H I). Galaxies with redder UV continua have larger covering fractions of H I characterized by higher line-of-sight extinctions. We develop a model which connects the ionizing escape fraction with E(B−V), and which may be used to estimate the ionizing escape fraction for an ensemble of galaxies. Alternatively, direct measurements of the escape fraction for our sample allow us to constrain the intrinsic LyC-to-UV flux density ratio to be 〈S(900 A-ring )/S(1500 A-ring )〉{sub int}≳0.20, a value that favors stellar population models that include weaker stellar winds, a flatter initial mass function, and/or binary evolution. Last, we demonstrate how the framework discussed here may be used to assess the pathways by which ionizing radiation escapes from high-redshift galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗