Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Studying Gamma-Ray Blazars With the GLAST-LAT

Thanks to its sensitivity (4 10{sup -9} ph (E> 100 MeV) cm{sup -2} s{sup -1} for one year of observation), the GLAST LAT should detect many more (over a thousand) gamma-ray blazars than currently known. This large blazar sample will enable detailed population studies to be carried out. Moreover, the LAT large field-of-view combined with the scanning mode will provide a very uniform exposure over the sky, allowing a constant monitoring of several tens of blazars and flare alerts to be issued. This poster presents the LAT performance relevant to blazar studies, more particularly related to timing and spectral properties. Major specific issues regarding the blazar phenomenon that the LAT data should shed light on thanks to these capabilities will be discussed, as well as the different approaches foreseen to address them. The associated data required in other bands, to be collected in contemporaneous/simultaneous multiwavelength campaigns are mentioned as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanism of γ-irradiation induced phase transformations in nanocrystalline Mn{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} ceramics

The structural, infrared absorption and magnetic property transformations in nanocrystalline Mn{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} samples irradiated with different doses (0, 15, 25 and 50 kGy) of γ-irradiation were investigated in this work and a mechanism of phase transformation/decomposition is provided based on the metastable nature of the Mn-atoms in the spinel lattice. The nano-powder sample was prepared by solution combustion route and the pellets of the sample were exposed to γ-radiation. Up to a dose of 25 kGy of γ-radiation, the sample retained the single phase cubic spinel (Fd-3m) structure, but the disorder in the sample increased. On irradiating the sample with 50 kGy γ-radiation, the spinel phase decomposed into new stable phases such as α-Fe{sub 2}O{sub 3} and ZnFe{sub 2}O{sub 4} phases along with amorphous MnO phase, leading to a change in the surface morphology of the sample. Along with the structural transformations the magnetic properties deteriorated due to breakage of the ferrimagnetic order with higher doses of γ-irradiation. Our results are important for the understanding of the stability, durability and performance of the Mn-Zn ferrite based devices used in space applications. - Graphical abstract: The nanocrystalline Mn{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} ceramic sample transforms to crystalline α-Fe{sub 2}O{sub 3} and ZnFe{sub 2}O{sub 4} phases (and amorphous MnO phase) at a γ-irradiation dose of 50 kGy, as MnO goes out of the spinel lattice. The high energy γ-irradiation causes structural damage to the nanomaterials leading to change in morphology of the sample as seen in the SEM images. - Highlights: • Mn atoms are more unstable in the Mn-Zn ferrite spinel lattice than Zn-atoms. • Displacement of Mn atoms by γ-radiation from the lattice renders phase transformation. • In Mn{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4}, Mn-ferrite cell transforms to crystalline α-Fe{sub 2}O{sub 3} and amorphous MnO. • The stable ZnFe{sub 2}O{sub 4} phase retains its structure even after 50 KGy γ-irradiation. • The γ-irradiation degrades the magnetic properties of Mn{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} ceramics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

All-sky Neutrino Point-source Search with IceCube Combined Track and Cascade Data

Despite extensive efforts, discovery of high-energy astrophysical neutrino sources remains elusive. We present an event-level simultaneous maximum likelihood analysis of tracks and cascades using IceCube data collected from 2008 April 6 to 2022 May 23 to search the whole sky for neutrino sources, and using a source catalog, for coincidence of neutrino emission with gamma-ray emission. This is the first time a simultaneous fit of different detection channels is used to conduct a time-integrated all-sky scan with IceCube. Combining all-sky tracks, with superior pointing power and sensitivity in the northern sky, with all-sky cascades, with good energy resolution and sensitivity in the southern sky, we have developed the most sensitive point-source search to date by IceCube that targets the entire sky. The most significant point in the northern sky aligns with NGC 1068, a Seyfert II galaxy, which, from the catalog search, shows a 3.5σ excess over background after accounting for trials. The most significant point in the southern sky does not align with any source in the catalog and is not significant after accounting for trials. A search for the single most significant Gaussian flare at the locations of NGC 1068, PKS 1424+240, and the southern highest-significance point shows results consistent with expectations for steady emission. Notably, this is the first time that a flare shorter than four years has been excluded as being responsible for NGC 1068’s emergence as a neutrino source. Our results show that combining tracks and cascades when conducting neutrino source searches improves sensitivity and can lead to new discoveries.

Abbasi, R. [Loyola University, Chicago, IL (United↗

Effects of Radiation and a High Iron Load on Bone Mineral Density

Astronauts on long duration space flight missions to the moon or mars are exposed to radiation and have increase iron (Fe) stores, both of which can independently induce oxidative stress and may exacerbate bone mass loss and strength. We hypothesize a high Fe diet and a fractionated gamma radiation exposure would increase oxidative stress and lower bone mass. Three mo-old, SD rats (n=32) were randomized to receive an adequate Fe diet (45 mg Fe/kg diet) or a high Fe diet (650 mg Fe/kg diet) for 4 wks and either a cumulative 3 Gy dose (fractionated 8 x 0.375 Gy) of gamma radiation (Cs-137) or sham exposure starting on day 14. Elisa kit assessed serum catalase, clinical analyzer assessed serum Fe status and ex vivo pQCT scans measured bone parameters in the proximal/midshaft tibia and femoral neck. Mechanical strength was assessed by 3-pt bending and femoral neck test. There is a significant decrease in trabecular bone mineral density (BMD) from radiation (p less than 0.05) and a trend in diet (p=0.05) at the proximal tibia. There is a significant interaction in cortical BMD from the combined treatments at the midshaft tibia (p less than 0.05). There is a trending decrease in total BMD from diet (p=0.07) at the femoral neck. In addition, high serum Fe was correlated to low trabecular BMD (p less than 0.05) and high serum catalase was correlated to low BMD at all 3 bone sites (p less than 0.05). There was no difference in the max load of the tibia or femoral neck. Radiation and a high iron diet increases iron status and catalase in the serum and decreases BMD.

Yuen, E.↗

Microstructure and texture of Nb + Ti stabilized ferritic stainless steel

The microstructure, texture and grain boundary character distribution of Nb + Ti stabilized ferritic stainless steel were analyzed using scanning electron microscopy, transmission electron microscopy and X-ray diffraction. The addition of alloying elements such as Ti and Nb to ferritic stainless steel causes the formation of TiN, NbC and Fe{sub 2}Nb. The textures of cold rolled samples were dominated by the {alpha}-fiber, while the textures of annealed samples exhibit a very strong {gamma}-fiber. The changes in texture are closely related to the grain boundary characteristics.

36 MATERIALS SCIENCE↗

Dual-headed SPECT for awake animal brain imaging

Abstract- Motion-corrected awake animal imaging is needed for normal-state investigations of models of neurological disease and brain activity. The awake animal brain SPECT/CT system, AwakeSPECT at Johns Hopkins University has in the past used a single gamma camera for imaging. Enhancements have been made by adding a pinhole collimator to the second gamma camera at the opposite side which has been previously equipped parallel hole collimator. Geometry calibration was performed using a custom built quality control phantom containing three Co-57 point sources and applied to the tomographic reconstruction code. Hot-rod phantom scans with Tc-99m were performed to test sensitivity and resolution improvements. The reconstruction results show significant resolution and sensitivity improvements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Corrosion of 15th and early 16th century stained glass from the monastery of Batalha studied with external ion beam

This paper reports the study of corrosion in two stained glass panels from the south aisle of Sta. Maria da Vitoria monastery, at Batalha (Portugal), one depicting the Last Supper (dated from 1508), and the other one showing a saint (c. 1450). These panels exhibit extensive corrosion with darkening phenomena that are an impediment to their correct visualization, a source of major concern both to conservators and curators. By using external micro-beam Particle Induced X-ray Emission (PIXE) and Particle Induced Gamma Emission (PIGE) spectrometry, the elemental compositions of large fragments were obtained, enabling the selection of representative corroded areas, from which elemental distribution maps were produced by scanning. Calcium and potassium rich structures were found - at the surface and inside cavities in the glass - that were identified as oxalates and carbonates, by Raman microscopy and micro-FTIR. The dark spots present in the glass surfaces were found to be Zn and Pb rich. These findings indicate that the corrosion observed was due not only to reactions with atmospheric water and CO{sub 2} but also with the oxalic acid secreted by micro-organisms. Furthermore, it did not result from reactions with atmospheric SO{sub 2} or acid rain. The information obtained is relevant for a better understanding of the corrosion processes and products formed on the surface of these panels and therefore for the proper planning of much needed adequate conservation-restoration actions and appropriate display conditions. - Research Highlights: {yields} Corrosion and darkening of stained glasses is of concern to conservators and curators. {yields} A multi-technique approach is of relevance to study stained glass corrosion. {yields} External beam PIXE-PIGE provide valuable insight on stained glass corrosion.

36 MATERIALS SCIENCE↗

Effects of Ionizing Radiation on the Thermodynamic Stability of Boehmite and Gibbsite

Here, in this study, we examined the effect of gamma radiation on the stabilities of aluminum hydroxide (gibbsite) and aluminum oxyhydroxide (boehmite) nanoparticles in relation to their thermal decomposition. X-ray diffraction (XRD) patterns and scanning electron microscopy (SEM) images revealed no significant differences in mineral components or morphology before and after radiation. However, thermogravimetric and differential scanning calorimetry (TGA/DSC) analyses showed that both boehmite and gibbsite nanoparticles experienced decreased mass loss following irradiation. Raman and attenuated total reflection-Fourier transfer infrared (ATR-FTIR) spectra indicated that a fraction of the hydroxyl content in both cases was selectively cleaved by radiation, primarily at the particle surfaces. Quantitative analyses of thermal mass loss behavior demonstrated that irradiated boehmite and gibbsite nanoparticles had higher activation energies than their pristine counterparts, with the extent of the increase dependent on the total dose. Taken together, these findings suggest that exposure to a sufficient dose of ionizing radiation alters these materials such that they are less prone to decomposition by dehydration. This increased stability may be due to the decreased hydrous nature of the samples after radiation exposure, which was supported by further high temperature drop calorimetry. Additionally, a radiation-induced amorphous phase on the nanoparticle surfaces appears to have a permanent and positive influence on their thermodynamic stabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements with Pinhole and Coded Aperture Gamma-Ray Imaging Systems

From a safeguards perspective, gamma-ray imaging has the potential to reduce manpower and cost for effectively locating and monitoring special nuclear material. The purpose of this project was to investigate the performance of pinhole and coded aperture gamma-ray imaging systems at Oak Ridge National Laboratory (ORNL). With the aid of the European Commission Joint Research Centre (JRC), radiometric data will be combined with scans from a three-dimensional design information verification (3D-DIV) system. Measurements were performed at the ORNL Safeguards Laboratory using sources that model holdup in radiological facilities. They showed that for situations with moderate amounts of solid or dense U sources, the coded aperture was able to predict source location and geometry within ~7% of actual values while the pinhole gave a broad representation of source distributions

Raffo-Caiado, Ana Claudia↗

Gamma Ray Burst Discoveries with the Swift Mission

There is a great synergy between the Swift and INTEGRAL missions. Swift provides wide-field hard x-ray monitoring and sensitive x-ray and UV/optical observations. INTEGRAL provides optical through gamma-ray coverage with emphasis on hard xray imaging and gamma-ray spectroscopy. For hard x-ray survey studies, the BAT and IBIS instruments are complementary with BAT covering the full sky every day and IBIS scanning the galactic plane. For GRBs, Swift follows up bursts detected by INTEGRAL. X-ray and optical observations give arcsecond positions and afterglow lightcurves. For IGR sources, X-ray observations identify counterparts. The joint BAT and IBIS survey data are giving the most complete picture of the hard x-ray sky ever obtained. This talk will review Swift capabilities and discuss joint observations that are taking place and planned

Gehrels, Neil↗

Evaluating Photocatalysts Using Gamma Radiation

A large amount of attention has been given to photocatalysts using UV radiation as the source of excitation; however, little work has been done to study photocatalysis using higher energy excitation sources, such as gamma or x-rays. During excitation, the photocatalyst absorbs light to produce electron-hole pairs (excitons). These excitons can react with absorbed species to yield reactive radical species that can degrade compounds or induce redox (oxidation-reduction) reactions. Common examples of semiconductor photocatalysts include: TiO{sub 2}, ZnO, Fe{sub 2}O{sub 3}, ZrO{sub 2}, and SnS. This project was conducted to investigate the photocatalytic oxidation of iron using gamma irradiation and several different semiconductor photocatalysts. Photometric Measurements: Photometric determination of Fe{sup II} and Fe{sup III} were made using a Cary 60 UV-Vis Spectrometer over a range of 800 - 200 nm at a scan rate of 60 nm/sec. Ferric (Fe{sup III}) ions have no detectable UV-vis spectrum, thus the absence of a peak in iron-based samples was taken as evidence of Fe{sup III} formation. Solution Preparation: Iron II (Fe{sup II}) standards were made by dissolving FeCl{sub 2}.6H{sub 2}O in deionized water using a sonicator. A solution of 1,10- phenanthroline was made by adding 40 mg of 1,10-phenanthroline to 20 mL of deionized water and sonicating for 60 minutes until a clear solution was obtained. Gamma Radiation Tests: Irradiated samples were exposed to Co-60 gamma radiation (1.17 MeV gamma) at a dose rate of ∼1 x 10{sup 5} Rad/hr Co-60. All samples were irradiated in glass scintillation vials. The presence of 30 mg of SnS reduces the amount of Fe{sup II} in solutions under gamma irradiation relative to samples with no SnS added. Fe{sup II} concentration decreases as irradiation time increases. This effect is enhanced when SnS is present. Fe{sup II} appears to decrease linearly with time. We found that the addition of SnS semiconductor, when combined with gamma radiation, oxidized more Fe{sup II} in the FeCl{sub 2} solution than gamma radiation alone. This suggests that SnS can be used as a photocatalyst using gamma radiation as the excitation source, although more detailed experiments are needed to confirm this belief. The next phase of this project would be to refine the preliminary results by determining exact quantities of SnS semiconductor and gamma radiation that induce sufficient redox. Repeated experiments with more samples could also give more data points for a chance at more representative and accurate data with error bars and standard deviations. Also, other semiconductors could possibly be tested to see how their effect on redox chemistry compares to that of SnS. The scope of this project could also be extended to include other metal or organic solutions to see if similar redox could be obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear fuel behavior at high temperature: new insights from post-test examinations on the VERDON-1 sample

In order to reduce the uncertainties concerning Source Term assessment under Light Water Reactor (LWR) severe accident conditions, 4 VERDON tests were recently performed. They have been defined in the framework of the International Source Term Program and carried out at CEA Cadarache, in the LECA-STAR facility. Among these 4 VERDON tests, VERDON-1 test was devoted to high burn-up UO{sub 2} fuel behavior and FP release under H{sub 2} reducing conditions at very high temperature. This test was performed with the Release Circuit, which is devoted to the precise characterization of the FP release, in terms of FP release kinetics and fission products (FPs) released fraction. The main components of the circuits are a furnace heating the fuel sample, a filter trapping the emitted aerosols and gamma spectrometry detectors for online and post-test measurements. VERDON-1 test was conducted up to about 2600 Celsius degrees without reaching global fuel relocation, allowing thereby post-test micro-analyses. After a brief description of the fuel sample nature and the experimental set-up, we present the progress of the experimental sequence and the associated gamma spectrometry measurements. We then focus on the major results of the VERDON-1 tests regarding the fuel global behavior. These results are obtained by two complementary techniques. First, the fuel sight gamma station can be used either on-line to detect fuel relocation or just after the test, as a longitudinal bench, to get preliminary information on the global shape of the fuel sample inside the furnace. Secondly, these information are completed by post-test examinations performed on the fuel sample after extraction from the furnace. Complete qualitative and quantitative characterizations, including EPMA (Electron Probe Micro-Analysis) and SEM (Scanning Electron Microscopy) analysis, were performed for the first time at the CEA Cadarache on a sample that has been submitted to such severe accident conditions. These results show an advanced state of sample degradation, with locally previously molten areas, meaning that fuel global relocation was imminent by the end of thermal-hydraulic sequence. The relocation temperature is compared to that of previous VERCORS tests and discussed regarding the atmosphere of the test and possible UO{sub 2}-ZrO{sub 2} interaction. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Myeloablative 131I-Tositumomab Radioimmunotherapy in Treating Non-Hodgkin’s Lymphoma: Comparison of Dosimetry Based on Whole-Body Retention and Dose to Critical Organ Receiving the Highest Dose

Objectives: Myeloablative radioimmunotherapy (RIT) using 131I tositumomab (anti-CD 20) monoclonal antibodies is an effective new therapy for B-cell non-Hodgkins lymphoma (NHL). The goal of this work is to determine optimum methods to deliver maximal myeloablative radioactivity without exceeding the radiation tolerance of critical normal organs such as liver and lungs, and avoiding serious toxicity. Methods: We reviewed dosimetry records for 100 consecutive patients who underwent biodistribution and dosimetry after a test infusion of 131I- tositumomab. Serial gamma camera images were used to determine organ and tissue activities over time and to calculate radiation-absorbed doses. Volumes of critical normal organs were determined from CT scans to adjust the dose estimates for the individual patient. These dose estimates helped us determine an appropriate therapy based on projected dose to the critical normal organ receiving a maximum tolerable radiation dose. We compared our method of organ-specific dosimetry for treatment planning with the standard clinical approaches using a whole-body dose-assessment method by assessing the difference in projected amounts of radiation-absorbed doses, as well as the ratios of projected amounts, that would be prescribed for therapy by each of these two strategies. Results: The mean organ doses (mGy/MBq) estimated by both methods were (1) Whole body method: liver = 0.33 and lungs = 0.33; and (2) Organ-specific method: liver 1.52 and lungs 1.72 (p = .0001). The median difference between the radiation-absorbed dose estimates was 3.40 (range of 1.37 to 7.96) for the lungs, 3.05 (range of 1.04 to 6.20) for the liver, and –0.05 for whole body (range of –0.18 to 0.16). The median ratio (OS divided by WB method) of radiation-absorbed dose estimates was 5.12 (range of 2.33 to 10.01) for the lungs, 4.14 (range of 2.16 to 6.67) for the liver, and 0.94 (range of 0.79 to 1.22) for whole body. There was significant difference between the dose estimated by the two methods for liver and lungs (p = 0.0001) and a significant correlation for whole body dose estimates by the two methods (R = 0.97) indicating confidence in the whole body dose estimation methods. Conclusions: Dosimetry based only on whole body retention will under-estimate the organ doses in a substantial number of patients, likely because it assumes a uniform distribution and clearance without accounting for patient-specific variations in biodistribution. Myeloablative treatment based on individual organ radiation absorbed dose provides the ability to safely administer the largest possible amounts of radioactivity and deliver an optimized radiation dose to tumor within the tolerance of normal organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gamma Imaging and Mapping Advancements

The SRNL developed GrayQb{sup TM} gamma mapping system has been successfully deployed in field situations. Currently, to get the image from the GrayQb{sup TM} the internal Phosphor Storage Plate (PSP) used to capture radiation images must be recovered and scanned by a ScanX Scanner. Upgrades are being implemented which will enable the GrayQB{sup TM} to read the PSP using a camera and red LEDs then transmit results to a remote location. This will greatly reduce personnel interaction, increasing safety as well as eliminating the need for the ScanX. Upgrades have been based off of the MiniMax, a Los Alamos National Laboratory developed PSP reading device constructed with a Nikon DSLR and a red LED flash to obtain the images from the PSP. The electronics in the upgraded GrayQb{sup TM} need to be both functional and environmentally rugged. A PC/104 was chosen for its wider operational temperature range and its physical durability. The Sony α7 ii and the Mightex are the candidate cameras for the upgrades based on test results. PSPs were exposed to gamma radiation sources at SRS's Health Physics Instrumentation Calibration Laboratory (HPICL). PSPs were tested with both Am-241 and Cs-137. Linear intensity increased with dose verifying UV image simulations. Data collected enabled the PSP intensity to be referenced to a total dose. Further work includes design and implementation of a 3D printed housing for the new camera system. The housing will include the camera, light flash, PSP holders, tungsten dual pinhole, PC/104, dosimeter, and a battery or tethering option. Once the housing is finalized further testing at the HPICL facility is planned for early August. During this testing, the final housing design will capture both Am-241 and Cs-137 images.

3D PRINTING↗

Dosimetric verification of a commercial Monte Carlo treatment planning system (VMC++) for a 9 MeV electron beam

The aim of this work was to evaluate the performance of the voxel-based Monte Carlo algorithm implemented in the commercial treatment planning system ONCENTRA MASTERPLAN for a 9 MeV electron beam produced by a linear accelerator Varian Clinac 2100 C/D. In order to realize an experimental verification of the computed data, three different groups of tests were planned. The first set was performed in a water phantom to investigate standard fields, custom inserts, and extended treatment distances. The second one concerned standard field, irregular entrance surface, and oblique incidence in a homogeneous PMMA phantom. The last group involved the introduction of inhomogeneities in a PMMA phantom to simulate high and low density materials such as bone and lung. Measurements in water were performed by means of cylindrical and plane-parallel ionization chambers, whereas measurements in PMMA were carried out by the use of radiochromic films. Point dose values were compared in terms of percentage difference, whereas the gamma index tool was used to perform the comparison between computed and measured dose profiles, considering different tolerances according to the test complexity. In the case of transverse scans, the agreement was searched in the plane formed by the intersection of beam axis and the profile (2D analysis), while for percentage depth dose curves, only the beam axis was explored (1D analysis). An excellent agreement was found for point dose evaluation in water (discrepancies smaller than 2%). Also the comparison between planned and measured dose profiles in homogeneous water and PMMA phantoms showed good results (agreement within 2%-2 mm). Profile evaluation in phantoms with internal inhomogeneities showed a good agreement in the case of ''lung'' insert, while in tests concerning a small ''bone'' inhomogeneity, a discrepancy was particularly evidenced in dose values on the beam axis. This is due to the inaccurate geometrical description of the phantom that is linked to the calculation voxel size, a feature over which the user has no control.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-135: Feasibility of Using Quantitative Cone Beam CT for Proton Adaptive Planning

Purpose: To investigate the feasibility of using scatter corrected cone beam CT (CBCT) for proton adaptive planning. Methods: Phantom study was used to evaluate the CT number difference between the planning CT (pCT), quantitative CBCT (qCBCT) with scatter correction and calibrated Hounsfield units using adaptive scatter kernel superposition (ASKS) technique, and raw CBCT (rCBCT). After confirming the CT number accuracy, prostate patients, each with a pCT and several sets of weekly CBCT, were investigated for this study. Spot scanning proton treatment plans were independently generated on pCT, qCBCT and rCBCT. The treatment plans were then recalculated on all images. Dose-volume-histogram (DVH) parameters and gamma analysis were used to compare between dose distributions. Results: Phantom study suggested that Hounsfield unit accuracy for different materials are within 20 HU for qCBCT and over 250 HU for rCBCT. For prostate patients, proton dose could be calculated accurately on qCBCT but not on rCBCT. When the original plan was recalculated on qCBCT, tumor coverage was maintained when anatomy was consistent with pCT. However, large dose variance was observed when patient anatomy change. Adaptive plan using qCBCT was able to recover tumor coverage and reduce dose to normal tissue. Conclusion: It is feasible to use qu antitative CBCT (qCBCT) with scatter correction and calibrated Hounsfield units for proton dose calculation and adaptive planning in proton therapy. Partly supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Multi-Scale Lithofacies and Chemostratigraphic Analysis of Two Middle Devonian Marcellus Shale Wells in Northern West Virginia, USA

The Marcellus Shale Energy and Environmental Laboratory (MSEEL) consists of two project areas within the dry gas producing region of the Marcellus shale play in Monongalia County, West Virginia. MSEEL is a collaborative field project led by West Virginia University, with Northeast Natural Energy LLC, several industrial partners, and sponsored by the US Department of Energy National Energy Technology Laboratory. The study areas are drilled approximately 8.5 miles apart to better understand the vertical and lateral changes in stratigraphy over a short distance. Two vertical pilot wells, MIP-3H and Boggess 17H were drilled in the fall of 2015 and spring of 2019, respectively. Core was recovered from the MIP-3H (API: 47-061-01707-00-00) 112 feet (34m) between depths of 7445 to 7557 feet, and from the Boggess 17H (API: 47-061-01812-00-00) 139 feet (42m) between depths of 7908 and 8012 ft. A full suite of triple combo (gamma ray, neutron, density logs), image logs, and advanced logging tools were run in both wells and calibrated to core analysis. Core analysis includes medical computed tomography (CT) scans, mineralogy and chemostratigraphy determined from handheld X-Ray fluorescence (hhXRF) and X-Ray powder diffraction (XRD) measurements, and determination of total organic content (TOC). Lithofacies were determined at core-scale using traditional core description techniques and medical CT-scan images. Log-scale facies are based on mineralogy and TOC data and developed using petrophysical logging data calibrated to core data (XRD and pyrolysis data). Chemostratigraphic analysis utilized hhXRF data to determine the major and trace element trends in the cores. In the two wells six shale lithofacies were recognized at the core and log scale. Both wells show organic-rich facies (TOC > 6.5%) primarily in the middle and lower Marcellus, with a slight decrease in thickness of this interval in the Boggess 17H. This interval is interpreted as an increase in paleo-productivity (increased Ni, Zn, and V), decreased sedimentation (decreased detrital proxies), and anoxic to euxinic conditions (increased Mo and chalcophile elements). Paleo-redox conditions in both wells are dynamic throughout deposition transitioning between euxinic/anoxic to dysoxic/oxic. This trend is seen through elemental proxies and calcite/pyrite concretion distributions.

03 NATURAL GAS↗

Drop Size Distribution Measurements Supporting the NASA Global Precipitation Measurement Mission: Infrastructure and Preliminary Results

Global Precipitation Measurement Mission (GPM) retrieval algorithm validation requires datasets that characterize the 4-D structure, variability, and correlation properties of hydrometeor particle size distributions (PSD) and accumulations over satellite fields of view (5 -- 50 km). Key to this process is the combined use of disdrometer and polarimetric radar platforms. Here the disdrometer measurements serve as a reference for up-scaling dual-polarimetric radar observations of the PSD to the much larger volumetric sampling domain of the radar. The PSD observations thus derived provide a much larger data set for assessing DSD variability, and satellite-based precipitation retrieval algorithm assumptions, in all three spatial dimensions for a range of storm types and seasons. As one component of this effort, the GPM Ground Validation program recently acquired five 3rd generation 2D Video disdrometers as part of its Disdrometer and Radar Observations of Precipitation Facility (DROP), currently hosted in northern Alabama by the NASA Marshall Space Flight Center and the University of Alabama in Huntsville. These next-generation 2DVDs were operated and evaluated in different phases of data collection under the scanning domain of the UAH ARMOR C-band dual-polarimetric radar. During this period approximately 7500 minutes of PSD data were collected and processed to create gamma size distribution parameters using a truncated method of moments approach. After creating the gamma parameter datasets the DSDs were then used as input to T-matrix code for computation of polarimetric radar moments at C-band. The combined dataset was then analyzed with two basic objectives in mind: 1) the investigation of seasonal variability in the rain PSD parameters as observed by the 2DVDs; 2) the use of combined polarimetric moments and observed gamma distribution parameters in a functional form to retrieve PSD parameters in 4-D using the ARMOR radar for precipitation occurring in different seasons and for different rain system types. Preliminary results suggest that seasonal variations in the DSD parameters do occur, but are most pronounced when comparing tropical PSDs to either winter or summer convective precipitation. For example the previously documented shift to relatively smaller drop diameters in higher number concentrations for equivalent rain rate bins was observed in tropical storm rainbands occurring over Huntsville. On a more inter seasonal basis empirical fits between parameters such as D0 and ZDR do not appear to exhibit robust seasonal biases- i.e., one fit seems to work for all seasons within acceptable standard error (O[10%]) for estimates of D0. In polarimetric retrievals of the vertical variability in PSD (rain layer) for a tropical rainband we find that the Do varies with height when partitioned by specified precipitation categories (e.g., convective or stratiform, heavy and light stratiform etc.) but this variation is of order 10-20% and is smaller than the difference in D0 observed between the basic delineation of convective and stratiform precipitation types. Currently we are expanding our analysis of the vertical structure of the PSD to include several seasonally and/or dynamically-different storm system types (e.g., winter convection and stratiform events; summer mid-latitude convective etc.) sampled by ARMOR. The study will present the results of our combined analyses.

Petersen, Walter A.↗