Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Evaluation of crystalline quality of traveling heater method (THM) grown Cd0.9Zn0.1Te0.98Se0.02 crystals

Because of its excellent opto-electronic properties, CdZnTe (CZT) has been the material of choice for x- and gamma-ray detectors operable at room temperature. CZT is the leading commercially available room-temperature radiation detector material today. Although much progress has been made over the past three decades, today's CZT crystals still face certain challenges, especially the presence of the performance-limiting materials defects and the associated relatively high production cost. In this regard, CdxZn1−xTeySe1−y (CZTS) is emerging as a next-generation compound semiconductor, which overcomes some of the limitations of CZT technology for the stated applications. Here, we conducted a study to evaluate the crystalline quality of the traveling heater method grown CZTS with an optimized alloy composition, i.e., Cd0.9Zn0.1Te0.98Se0.02. The as-grown samples were evaluated by low-temperature photoluminescence (PL) spectroscopy and high-resolution x-ray diffraction using the synchrotron light source at Brookhaven National Laboratory. The full width at half maximum of both the PL and x-ray rocking curves was observed to be broadened due to the lattice disorder of the quaternary compound, eventually degrading the crystalline quality. This was consistent with density functional theory calculations.

Roy, U. N. (ORCID:0000000282089680)↗

Thermal aging effects on crosslinked polyethylene cable insulation with decabromodiphenyl ether flame retardant alternative

Decabromodiphenyl ether (decaBDE) has been extensively used as a flame retardant in several applications, including nuclear electrical cable insulation. However, decaBDE has been identified as a persistent, bioaccumulative and toxic (PBT) substance, leading to regulatory scrutiny. The Environmental Protection Agency (EPA) published a regulation on January 6, 2021, aimed at phasing out the manufacturing, processing, and distribution of decaBDE. This rule set a compliance deadline of March 8, 2021, for the manufacture and processing of decaBDE, and an extended deadline of January 6, 2023, for specific applications including wire and cable insulation in nuclear power generation facilities. In response to such regulations, RSCC, a major supplier of safety-related electrical cables and associated products to the U.S. nuclear industry updated the formula of their crosslinked polyethylene (XLPE) insulation to replace the historically used decaBDE flame retardant with an acceptable alternative. This change from the previous decaBDE-containing XLPE prompted interest in comparative performance of the two material formulations, especially with respect to characteristics relevant to safety-related function such as thermal and radiation resistance. RSCC graciously provided samples of wire insulated with the decaBDE-containing XLPE formulation and corresponding wire insulated with XLPE of the new formulation, containing a decaBDE alternative. In this work we compare characteristics of the two formulations and a previously produced commercial version of the RSCC decaBDE-containing XLPE insulation subjected to thermal aging at 150 °C and 165 °C. The comparison was focused on mechanical durability, thermal stability in the oxidative environment, and chemical structures. Briefly, • Tensile elongation at break (EAB) results showed loss of mechanical elasticity with longer aging time, as expected. Aging time dependence of EAB did not differ between the decaBDE-containing and decaBDE-alternative samples. • Subtle differences between the two materials can be detected from Fourier-transform infrared spectroscopy (FTIR) absorbance spectra in the range below 1700 cm -1 , are assumed to be related to decomposition of flame retardant additives during thermal aging. • The oxidation induction time (OIT) data seemed to show that the unaged decaBDE-containing XLPE material is more thermally stable than the unaged decaBDE-alternative material, but the discrepancy in OIT decreased with aging time and the OIT values of the two materials became similar starting with the 4 th day of aging at 165 °C. This thermal aging investigation confirmed that the mechanical durability, a key property monitored for cable qualification, was not significantly affected by the modification of the formulation with a decaBDE alternative flame-retardant system in the investigated thermal aging conditions. Further studies on the same sets of materials exposed to thermal and gamma radiation aging would further inform comparison of the materials safety-related function.

36 MATERIALS SCIENCE↗

AT2025ulz and S250818k: Leveraging DESI Spectroscopy in the Hunt for a Kilonova Associated with a Subsolar-mass Gravitational-wave Candidate

On 2025 August 18, the LIGO–Virgo–KAGRA collaboration reported a subthreshold gravitational-wave candidate detection consistent with a subsolar-mass neutron star merger, denoted S250818k. An optical transient, AT2025ulz, was discovered within the localization region. AT2025ulz initially appeared to meet the expected behavior of kilonova emission, the telltale signature of a binary neutron star merger. The transient subsequently rebrightened after ∼5 days and was classified as a Type IIb supernova. In this work, we analyze the observations of its host galaxy obtained by the Dark Energy Spectroscopic Instrument (DESI). From the DESI spectrum, we obtain a secure redshift of z = 0.084840 ± 0.000006. If S250818k has an astrophysical origin, this places the transient within 2σ of the gravitational-wave distance and results in an integral overlap between the gravitational-wave alert and the transient location of log 10 $\mathcal{I} ≈ 3.9 - 4.2$. Our analysis of the host galaxy’s spectral energy distribution reveals a star-forming, dusty galaxy with stellar mass ∼10 10 M ⊙ , broadly consistent with the population of both short gamma-ray bursts and core-collapse supernova host galaxies. We also present our follow-up of DESI-selected candidate host galaxies using the Fraunhofer Telescope at the Wendelstein Observatory, and show the promise of DESI for associating or rejecting candidate electromagnetic counterparts to gravitational-wave alerts. These results emphasize the value of DESI’s extensive spectroscopic dataset in rapidly characterizing host galaxies, enabling spectroscopic host subtraction, and guiding targeted follow-up.

Hall, Xander J. [Carnegie Mellon University, Pitts↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Positron Emission Intensity in the Decay of 86 gY for Use in Dosimetry Studies

The β + -emitting radionuclide 86 gY (t 1/2 = 14.7 h) forms a matched-pair with the β – -emitting therapeutic radionuclide 90Y (t 1/2 = 2.7 d) for theranostic application in medicine. This approach demands a precise knowledge of the positron emission probability of the PET nuclide which was until recently rather uncertain for 86 gY. In this work, an 86 gY source of high radionuclidic purity was prepared and a direct measurement of the positron emission intensity per 100 decay of the parent (hereafter “positron emission intensity”) was performed using high-resolution HPGe detector γ-ray spectroscopy. The electron capture intensity was also determined as an additional check by measuring the K α and K β X-rays of energies 14.1 and 15.8 keV, respectively, using a low energy HPGe detector. From those measurements, normalized values of 27.2 ± 2.0% for β + -emission and 72.8 ± 2.0% for EC were obtained. These results are in excellent agreement with values recently reported in the literature based on a detailed decay scheme study.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of f -element complexation on the radiolysis of 2-ethylhexylphosphonic acid mono-2-ethylhexyl ester (HEH[EHP])

A systematic study of the impact on the chemical reactivity of the oxidising n-dodecane radical cation (RH˙ + ) with f-element complexed 2-ethylhexylphosphonic acid mono-2-ethylhexyl ester (HEH[EHP]) has been undertaken utilizing time-resolved electron pulse radiolysis/transient absorption spectroscopy and high-level quantum mechanical calculations. Lanthanide ion complexed species, [Ln((HEH[EHP]) 2 ) 3 ], exhibited vastly increased reactivity (over 10× faster) in comparison to the non-complexed ligand in n-dodecane solvent, whose rate coefficient was k = (4.66 ± 0.22) × 10 9 M -1 s -1 . Similar reactivity enhancement was also observed for the corresponding americium ion complex, k = (5.58 ± 0.30) × 10 10 M -1 s -1 . The vastly increased reactivity of these f-element complexes was not due to simple increased diffusion-control of these reactions; rather, enhanced hole transfer mechanisms for the complexes were calculated to become energetically more favourable. Interestingly, the observed reactivity trend with lanthanide ion size was not linear; instead, the rate coefficients showed an initial increase (Lu to Yb) followed by a decrease (Tm to Ho), followed by another increase (Dy to La). This behaviour was excellently predicted by the calculated reaction volumes of these complexes. In conclusion, complementary cobalt-60 gamma irradiations for select lanthanide complexes demonstrated that the measured kinetic differences translated to increased ligand degradation at steady-state timescales, affording ~38% increase in ligand loss of a 1:1 [La((HEH[EHP]) 2 ) 3 ]: HEH[EHP] ratio system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrahigh‐Flux X‐ray Detection by a Solution‐Grown Perovskite CsPbBr 3 Single‐Crystal Semiconductor Detector

Abstract Solution‐processed perovskites are promising for hard X‐ray and gamma‐ray detection, but there are limited reports on their performance under extremely intense X‐rays. Here, a solution‐grown all‐inorganic perovskite CsPbBr 3 single‐crystal semiconductor detector capable of operating at ultrahigh X‐ray flux of 10 10 photons s −1 mm −2 is reported. High‐quality solution‐grown CsPbBr 3 single crystals are fabricated into detectors with a Schottky diode structure of eutectic gallium indium/CsPbBr 3 /Au. A high reverse‐bias voltage of 1000 V (435 V mm − 1 ) can be applied with a small and stable dark current of ≈60–70 nA (≈9–10 nA mm − 2 ), which enables a high sensitivity larger than 10 000 µC Gy air −1 cm − 2 and a simultaneous low detection limit of 22 nGy air s − 1 . The CsPbBr 3 semiconductor detector shows an excellent photocurrent linearity and reproducibility under 58.61 keV synchrotron X‐rays with flux from 10 6 to 10 10 photons s − 1 mm − 2 . Defect characterization by thermally stimulated current spectroscopy shows a similar low defect density of a synchrotron X‐ray and a lab X‐ray irradiated device. Solid‐state nuclear magnetic resonance spectroscopy suggests that the excellent performance of the solution‐grown CsPbBr 3 single crystal may be associated with its good short‐range order, comparable to the spectrometer‐grade melt‐grown CsPbBr 3 .

Pan, Lei↗

Experiment Design and Preparation for a Shielding Benchmark Utilizing Godiva-IV

An experiment is currently being designed to provide a high-quality shielding benchmark for Criticality Accident Alarm System (CAAS) modeling. Previous benchmarks have suffered from uncertainty primarily due to two factors. The first factor is radiation that is not directly coming from the source, also known as room return. Room return is notoriously difficult to account for in experimental data and to model in benchmarks. The second factor is uncertainty associated with the source term itself. In order to reduce these two sources of uncertainty, this experiment will utilize a room return shield [1] that will reduce the effect of room return and previous work performed to ensure the reproducibility of the source term. The experiment will use the Godiva IV [2] assembly located at the National Criticality Experiments Research Center (NCERC) to provide a neutron source representative of a criticality accident. Previous experiments [3]-[4] have shown that Godiva IV is capable of producing both bursts and steady-state emissions of equal magnitude which will allow for reduced uncertainty in the source term. The room return shield will house and isolate the shielding samples, neutron activation foils, and other detectors. Data collected will provide a comparison of the neutron and gamma dose for shielded and unshielded configurations. This data will be used to validate shielding data used for modeling criticality accident alarm systems. Shielding samples included in this benchmark are C, Fe, NaCl, Pb, high density polyethylene, and SiO 2 . This paper details the design of the room return shield, the experimental plan, challenges, and mitigation strategies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The eROSITA Final Equatorial-Depth Survey (eFEDS)

The eROSITA Final Equatorial Depth Survey (eFEDS), completed in survey mode during the calibration and performance verification phase of the eROSITA instrument on Spectrum Roentgen Gamma, delivers data at and beyond the final depth of the 4-yr eROSITA all-sky survey (eRASS:8), f 0.5–2 keV = 1.1 × 10 –14 erg s –1 cm –2 , over 140 deg 2 . It provides the first view of normal galaxy X-ray emission from X-ray binaries (XRBs) and the hot interstellar medium at the full depth of eRASS:8. We used the Heraklion Extragalactic Catalogue (HECATE) of galaxies to correlate with eFEDS X-ray sources and identify X-ray detected normal galaxies. This flux-limited X-ray survey is relatively free from selection effects and enables the study of integrated normal galaxy X-ray emission and its relation to galaxy parameters such as the stellar mass, star formation rate (SFR), and metallicity. We cross-correlated 32 646 eFEDS X-ray sources to 1181 HECATE normal galaxies and obtained 94 matches. We classified galaxies as star-forming, early-type, composite, and active galactic nuclei (AGN) using Sloan Digital Sky Survey (SDSS) and Six-degree Field (6dF) optical spectroscopy. The eFEDS field harbours 37 normal galaxies: 36 late-type (star-forming) galaxies and one early-type galaxy. There are 1.9 times as many normal galaxies as predicted by scaling relations via simulations, with an overabundance of late-type galaxies and a dearth of early-type galaxies. When compared with empirical relations, eFEDS dwarf galaxies with a high specific SFR have elevated L X /SFR at a fixed specific SFR and metallicity, indicating an increase in XRB emission due to low metallicity. We expect that eRASS:8 will detect 12 500 normal galaxies, the majority of which will be star-forming, with the caveat that there are unclassified sources in eFEDS and galaxy catalogue incompleteness issues that could increase the actual number of detected galaxies over these current estimates. eFEDS observations detected a rare population of galaxies – the metal-poor dwarf starbursts – that do not follow known scaling relations. eRASS is expected to discover significant numbers of these high-redshift analogues, which are important for studying the heating of the intergalactic medium at high redshift. Further investigation of the hot gas emission from normal galaxies and stochastic effects in the dwarf galaxy population are required to constrain their X-ray output.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of selenium in CdZnTeSe quaternary compound for radiation detector applications

X- and gamma-ray detectors are increasingly becoming essential tool for science and technology in various fields include homeland security, nonproliferation, nuclear security, medical imaging, astrophysics, and high energy physics. Cd 1-x Zn x Te 1-y Se y (CZTS) is emerging as a next-generation compound semiconductor for such applications. CZTS was found to possesses a very low concentration of Te inclusions and free from sub-grain boundary networks. Being a quaternary compound with varying alloy composition, optimization of the composition was performed to determine the minimum amount of selenium required to produce CZTS with reduced defects. The optimized composition was found to be x=0.10 and y=0.02, i.e., Cd 0.9 Zn0.1Te 0.98 Se 0.02 , for excellent material properties as a radiation detector. The resulting material was free from sub-grain boundary networks and with a highly reduced concentration of Te inclusions. The bulk dark resistivity obtained was in the range of 1-3x1010 ohm-cm with the highest achieved mobility-lifetime product of ~6.6x10-3 cm2/V for the optimized CZTS composition. Impurity analyses were performed by the Glow Discharge Mass Spectroscopy (GDMS) technique, and the results showed relatively high impurity concentrations compared to commercial detector-grade CdZnTe. Thus, CZTS has room for further improvement with additional purification of the starting materials.

36 MATERIALS SCIENCE↗

Determination of the vacancy distribution over Al cation sites in γ-Al 2 O 3

Although gamma-alumina (γ-Al 2 O 3 ) is an extensively used material with wide-ranging applications due to its inherently high surface area and acidity, its atomic structure is still not fully understood. γ-Al 2 O 3 is described as having a spinel-like structure, where the O sublattice has a face-centered cubic (FCC) arrangement and Al cations are placed in the spinel tetrahedral and octahedral interstitial sites. Achieving the correct stoichiometry of Al 2 O 3 , however, requires the introduction of Al vacancies into some of the interstitial sites. Despite the importance of accurately describing the structure of γ-Al 2 O 3 , the distribution of vacancies between tetrahedral and octahedral sites remains unclear, in part because of the usually poor crystalline quality of γ-Al 2 O 3 that has often been used in previous studies. To determine the actual cation distribution in γ-Al 2 O 3 , single-crystalline γ-Al 2 O 3 was investigated using a correlative approach of experimental and simulated selected-area electron diffraction (SAED) and high-resolution electron energy-loss spectroscopy (EELS). Comparison of the reflection intensities in single-crystal SAED to simulated SAED from models with varied vacancy distributions revealed that vacancies exist primarily on tetrahedral sites, contrary to the placement of vacancies on octahedral sites proposed in several common models. Comparison of EELS spectra—acquired with the highest energy resolution reported so far for γ-Al 2 O 3 —with ab initio multiple scattering EELS simulations confirmed the distribution of vacancies on tetrahedral sites. These results enable more accurate modeling of γ-Al 2 O 3 to better predict its properties in existing and future applications.

36 MATERIALS SCIENCE↗

Second Report of the Nuclear Data Subcommittee of the Nuclear Science Advisory Committee

The central importance of the nuclear data curated by the US Nuclear Data Program (USNDP) for clean energy generation, national security, nonproliferation, medical applications, and space exploration as well as basic science was described in a prior report issued by the DOE/NSF Nuclear Science Advisory Committee subcommittee on Nuclear Data (NSAC-ND) in September 2022. In this report, we present a set of fourteen (14) recommendations that will enhance and advance DOE-NP's stewardship of nuclear data. The first three recommendations focus on the existing core USNDP capabilities, namely: 1) Support the nuclear structure evaluation workforce to improve the currency, consistency, and accessibility of the Evaluated Nuclear Structure Data File (ENSDF); 2) Enhance nuclear reaction evaluation within the USNDP in support of the Evaluated Nuclear Data File (ENDF) through expansion of the workforce and integration of high-performance computing, automation, and machine learning and; 3) Continue atomic mass evaluation in support AME and NUBASE databases. This is followed by eight (8) recommendations representing new cross-cutting initiatives involving both measurement and evaluation to address outstanding nuclear data needs. These new initiatives require a highly trained, diverse workforce that includes personnel with expertise from both inside and outside the nuclear physics community from which evaluators have traditionally been recruited. As such, many of these initiatives are accomplished via a Topical Nuclear Data Collaborations (TNDC). A TNDC is made up of domestic and international stakeholders, subject matter and nuclear data experts, and nuclear data evaluators and features a workforce development plan to ensure that nuclear data evaluators maintain currency in the relevant applications and are seen as equity partners in the endeavor. These include: 1) Establish a coordinated effort to improve evaluation and modeling in nuclear astrophysics for stellar dynamics, multi-messenger astronomy and nucleosynthesis; 2) Initiate a TNDC to develop and maintain nuclear structure evaluation beyond discrete states, including nuclear level densities, photon strength functions and photonuclear data for improved reaction modeling, and exploring nuclear structure at finite temperature; 3) Create a TNDC to perform correlated fission data evaluation, including cross sections, fragment yields, v(A), v(E n ) for nuclear energy, national security, nonproliferation and basic science; 4) From a panel of subject matter experts to establish and annually update a roster of key decay data to nurture its accelerated dissemination including both measurement and evaluation for targeted high-value nuclides for national security, nonproliferation and medical applications; 5) Comprehensive, consistent neutron-induced structure and reaction data for nuclear energy, national security, nonproliferation and planetary nuclear spectroscopy; 6) Charged-particle stopping powers for detector design, space effects and ion beam therapy; 7) High-energy reactions for space exploration and medical nuclide production, and; 8) The creation of an infrastructure for open data and data preservation for use by the entire nuclear physics community. All told, these initiatives require approximately $6.5M increase in NP support of the USNDP in fiscal year 2023 dollars and would require at least 3-5 years to carry out due to the length of time needed to recruit and train new nuclear data researchers. This relatively modest investment would help ensure that the fruits of the nuclear data research carried out by DOE-NP and its collaborators would be brought to bear to address some of the most important needs of our nation and the world. To ensure effective execution of this plan, we present an overview of recruitment, training, and retention goals for the USNDP, the centerpiece of which is a mutually agreed upon code of conduct. Finally, we identify the facility and instrumentation needed to perform the recommended experimental activities. This includes a short review of target fabrication capabilities, reactors, neutron beam, light- and heavy-stable ion, gamma-ray, high-energy and radioactive ion beam facilities. Lastly, a more complete appendix of experimental facilities previously compiled is included with new input provided for 6 facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The eROSITA Final Equatorial-Depth Survey (eFEDS)

Aims. The eROSITA Final Equatorial-Depth Survey (eFEDS), executed during the performance verification phase of the Spectrum-Roentgen-Gamma (SRG)/eROSITA telescope, was completed in November 2019. One of the science goals of this survey is to demonstrate the ability of eROSITA to detect samples of clusters and groups at the final depth of the eROSITA all-sky survey. Methods. Because of the sizeable (≈26" HEW FOV average) point-spread function of eROSITA, high-redshift clusters of galaxies or compact nearby groups hosting bright active galactic nuclei (AGN) can be misclassified as point sources by the source detection algorithms. A total of 346 galaxy clusters and groups in the redshift range of 0.1 < z < 1.3 were identified based on their red sequenc in the eFEDS point source catalog. Results. We examine the multiwavelength properties of these clusters and groups to understand the potential biases in our selection process and the completeness of the extent-selected sample. We find that the majority of the clusters and groups in the point source sample are indeed underluminous and compact compared to the extent-selected sample. Their faint X-ray emission, well below the flux limit of the extent-selected eFEDS clusters, and their compact X-ray emission are likely to be the main reason for this misclassification. In the sample, we confirm that 10% of the sources host AGN in their brightest cluster galaxies (BCGs) through optical spectroscopy and visual inspection. By studying their X-ray, optical, infrared, and radio properties, we establish a method for identifying clusters and groups that host AGN in their BCGs. We successfully test this method on the current point source catalog through the Sloan Digital Sky Survey optical spectroscopy and find eight low-mass clusters and groups with active radio-loud AGN that are particularly bright in the infrared. They include eFEDS J091437.8+024558, eFEDS J083520.1+012516, and eFEDS J092227.1+043339 at redshifts 0.3-0.4. Conclusions. This study helps us to characterize and understand our selection process and assess the completeness of the eROSITA extent-selected samples. The method we developed will be used to identify high-redshift clusters, AGN-dominated groups, and low-mass clusters that are misclassified in the future eROSITA all-sky survey point source catalogs.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiwavelength Observations of a New Redback Millisecond Pulsar 4FGL J1910.7-5320

We present the study of multiwavelength observations of an unidentified Fermi Large Area Telescope (LAT) source, 4FGL J1910.7-5320, a new candidate redback millisecond pulsar binary. In the 4FGL 95% error region of 4FGL J1910.7-5320, we find a possible binary with a 8.36 hr orbital period from the Catalina Real-Time Transient Survey, confirmed by optical spectroscopy using the SOAR telescope. This optical source was recently independently discovered as a redback pulsar by the TRAPUM project, confirming our prediction. We fit the optical spectral energy distributions of 4FGL J1910.7-5320 with a blackbody model, inferring a maximum distance of 4.1 kpc by assuming that the companion fills its Roche lobe with a radius of R = 0.7 R ⊙ . Using a 12.6 ks Chandra X-ray observation, we identified an X-ray counterpart for 4FGL J1910.7-5320, with a spectrum that can be described by an absorbed power law with a photon index of 1.0 ± 0.4. The spectrally hard X-ray emission shows tentative evidence for orbital variability. Using more than 12 yr of Fermi-LAT data, we refined the position of the γ-ray source, and the optical candidate still lies within the 68% positional error circle. In addition to 4FGL J1910.7-5320, we find a variable optical source with a periodic signal of 4.28 hr inside the 4FGL catalog 95% error region of another unidentified Fermi source, 4FGL J2029.5-4237. However, the γ-ray source does not have a significant X-ray counterpart in an 11.7 ks Chandra observation, with a 3σ flux upper limit of 2.4 × 10 -14 erg cm -2 s -1 (0.3–7 keV). Moreover, the optical source is outside our updated Fermi-LAT 95% error circle. These observational facts all suggest that this new redback millisecond pulsar powers the gamma-ray source 4FGL J1910.7-5320 while 4FGL J2029.5-4237 is unlikely the γ-ray counterpart to the 4.28 hr variable.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of interrupted cooling on the development of bimodal γ' precipitate distributions in ATI 718Plus

The influence of aging treatments on the evolution of the γ' precipitates in ATI 718Plus was studied using scanning electron microscopy, energy dispersive spectroscopy, transmission electron microscopy, and atomic probe tomography. A set of aging treatments was performed on solution-treated samples to obtain various γ' size distributions. The aging temperatures ranged from 720 to 900°C with holding times of either two hours (for the 900°C aging temperature) or 10 h (for the 720°C and 750°C aging temperatures) followed by either air cooling, furnace cooling, or water quenching. The cooling method and aging temperature influenced the distribution of the solute elements. This work discussed the evolution of the γ' precipitation during single-step aging and two-step aging involving continuous cooling or interrupted cooling. Finally, a bimodal size distribution of the γ' precipitates was obtained through interrupted cooling two-step aging treatments, while single-step aging resulted in unimodal γ' precipitate distributions.

36 MATERIALS SCIENCE↗

CHICOX, a heavy-ion detection system for GRETA

The CHICOX detection system is an array of position sensitive parallel plate avalanche counters used for heavy ion detection in in-beam particle-gamma coincidence experiments. CHICOX, an upgrade of the CHICO2 array, is geometrically compatible with the GRETINA and GRETA gamma-ray arrays and provides an angular resolution sufficient to utilize the excellent position resolution of GRETINA/GRETA. CHICOX was successfully commissioned and fielded as an auxiliary detector to GRETINA in a campaign of stable-beam Coulomb excitation experiments at the ATLAS facility of Argonne National Laboratory. We report here on the design and in-beam performance of the CHICOX array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal and kinematic properties of ejecta in SN1987A revealed by XRISM

We present an analysis of high-resolution spectra from the shock-heated plasmas in SN 1987A, based on an observation using the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM). The 1.7–10 keV Resolve spectra are accurately represented by a single-component, plane-parallel shock plasma model, with a temperature of $2.84_{-0.08}^{+0.09}$ keV and an ionization parameter of $2.64_{-0.45}^{+0.58}$ × $10^{11}\,\,{\rm s\,\, cm}^{-3}$. The Resolve spectra are also well reproduced by the 3D magneto-hydrodynamic simulation presented by Orlando et al. (2020, A&A, 636, A22) suggesting substantial contribution from the ejecta. The metal abundances obtained with Resolve align with the Large Magellanic Cloud value, indicating that the X-rays in 2024 originate from “non-metal-rich” shock-heated ejecta and the reverse shock has not reached the inner metal-rich region of ejecta. Doppler widths of the atomic lines from Si, S, and Fe correspond to velocities of 1500–1700 km s$^{-1}$, where the thermal broadening effects in this non-metal-rich plasma are negligible. Therefore, the line broadening seen in Resolve spectra is determined by the large bulk motion of ejecta. For reference, we determined a $90\%$ upper limit on non-thermal emission from a pulsar wind nebula at $4.3 \times 10^{-13}$ erg cm$^{-2}$ s$^{-1}$ in the 2–10 keV range, aligning with NuSTAR findings by Greco et al. (2022, ApJ, 931, 132). Additionally, we searched for the $^{44}$Sc K line feature and found a $1\sigma$ upper limit of $1.0 \times 10^{-6}$ photons cm$^{-2}$ s$^{-1}$, which translates to an initial $^{44}$Ti mass of approximately $2 \times 10^{-4}\, M_{\odot }$, consistent with previous X-ray to soft gamma-ray observations (Boggs et al. 2015, Science, 348, 670; Grebenev et al. 2012, Nature, 490, 373; Leising 2006, ApJ, 651, 1019).

ISM: supernova remnants↗