Effects of Specimen Geometry on Flatwise Tensile Strength
The through-thickness or flatwise strength of a uniaxial polymer matrix composite was investigated with several test specimen geometries and starting plate thicknesses. The use of thinner plates is desirable to save material and lower costs during materials development programs. The various configurations gave similar results with the exception of thin, straight-sided specimens. Thin specimens tended to provide invalid results per ASTM International D7291; however, the addition of a large, shallow radius improved the results. The Weibull distribution provided a good fit to the combined data.