Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Designing and Operating Resilient Electric Distribution Grids [Slides]

In the past, electricity was produced by power plants on the transmission system and distributed to customers through substations. Now, distributed energy resources and dynamic loads are penetrating distribution grids, with their own energy production, resilience, and reliability challenges separate from the traditional model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control approach for power modulation of end-use loads

Methods, apparatus, and systems are disclosed herein for power modulation control of power grids using end-use loads. At the beginning of a coordination period typically lasting a few minutes, a population of end-use loads (water heaters, air conditioners, plug-in electric vehicles, etc.) is interrogated for their willingness to participate in power modulation by undergoing state transitions from on to off, or off to on. Distribution system flexibilities are calculated from the sums of device powers within distribution systems. Area flexibilities are calculated from the sums of device powers within areas. Thresholds for various devices to change state in response to inter-area oscillation damping or frequency regulation are derived from these flexibilities. Two power functions are monitored in real-time and compared with the device thresholds to trigger state changes which then remain locked throughout the remainder of the coordination period, then the devices are released from the lockout state.

Lian, Jianming↗

Emerging Technologies: Integrating with the Power Grid of Tomorrow

Traditional interactions between the built environment and the electric utility industry are changing rapidly. Rather than a one-way flow of electricity where utilities produce and transmit the electricity that buildings then consume, buildings are becoming efficient energy consumers that can dynamically adjust loads to ensure grid-provided energy is used effectively. Buildings are transitioning to now be at the intersection of forecasting loads and demand response, forecasting and control of output from distributed generation and renewable energy systems, and the optimal dispatch of energy storage. Because residential and commercial buildings consume 74.7% of the electricity generated in the United States, grid-integrated buildings represent an important solution to addressing challenges facing the power sector. In addition to the electric power grid, buildings will be increasingly interactive with water, transportation, and telecommunications networks, and will also more strongly affect surrounding buildings and other civic infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Variable Nuclear Electricity with Base-Load Reactor, Closed Brayton Power Cycle and Firebrick Resistance-Heated Energy Storage (Fires)

Power cycle choices are determined by markets and available technologies. Two changes are occurring in the electricity sector. First, the world is beginning to move away from fossil fuels because of concerns about climate change. What replaces fossil fuels for variable electricity production? Second, there have been extraordinary technological advances in gas turbine technology. The changes in market requirements and technology suggest the need to reexamine nuclear power cycles. One option is to couple high-temperature base-load nuclear reactors to closed Brayton cycles (helium, nitrogen, etc.) with Firebrick Resistance-Heated Energy Storage (FIRES). The reactor operates at base-load but not the power cycle. When electricity prices are low, firebrick is electrically heated to high temperatures using base-load electricity and/or electricity from the grid. The gas turbine can use nuclear heat for base-load operation and produce added peak electricity by sending the compressed heated gas through hot firebrick after nuclear heating to further raise power cycle gas temperatures and power output from the turbine-creating a nuclear plant with a thermodynamic topping (NUTOP) cycle. If such cycles can be developed, they would increase plant revenue and enable a low-carbon electricity grid. Such cycles can be coupled to Fluoride-salt-cooled High-temperature Reactors (FHRs), molten salt reactors (MSRs), high-temperature gas-cooled reactors (HTGRs), sodium-cooled fast reactors (SFRs) and lead-cooled fast reactors (LFRs). We discuss (1) market changes, (2) previous work on Nuclear Air-Brayton Combined cycles (NACC) with base-load reactors and variable power to the electricity grid and (3) options for closed Brayton cycles with variable power while the reactor operates at base load. Market (customer) requirements ultimately drive selection of power cycles. A low-carbon electricity grid requires dispatchable nuclear electricity to replace the traditional role of fossil fuels in the electricity grid. While reactors can be operated at part load, this is expensive for a capital-intensive low-operating-cost technology. Brayton power cycles with FIRES have the potential capability to provide that variable electricity while the reactor operates at base load to (1) improve economics and (2) enable a zero-carbon electrical grid. Open Brayton cycles have been investigated. Work has now started on developing closed Brayton cycles with FIRES. Only limited work has been done to date has been done for closed cycles with FIRES. (authors)

42 ENGINEERING↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

Demand Response in the ERCOT Markets [Slides]

ERCOT grid serves 85% of Texas load over 40K+ miles transmission line. Demand response: voluntary load response, load resources, controllable load resources, and emergency interruptible load service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexible Grid Interconnections

Key Considerations: - Long-term coordination and collaboration with utilities and ISOs may provide mutual benefits and support flexible interconnectivity. - Onsite storage and energy production can reduce load fluctuations and support grid resilience in the future. - Geography and resource availability can impact energy demand and grid flexibility.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

FY 2016 Status Report: Documentation of All CIRFT Data including Hydride Reorientation Tests (Draft M2)

The first portion of this report provides a detailed description of fiscal year (FY) 2015 test result corrections and analysis updates based on FY 2016 updates to the Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) program methodology, which is used to evaluate the vibration integrity of spent nuclear fuel (SNF) under normal conditions of transport (NCT). The CIRFT consists of a U-frame test setup and a real-time curvature measurement method. The three-component U-frame setup of the CIRFT has two rigid arms and linkages connecting to a universal testing machine. The curvature SNF rod bending is obtained through a three-point deflection measurement method. Three linear variable differential transformers (LVDTs) are clamped to the side connecting plates of the U-frame and used to capture deformation of the rod. The second portion of this report provides the latest CIRFT data, including data for the hydride reorientation test. The variations in fatigue life are provided in terms of moment, equivalent stress, curvature, and equivalent strain for the tested SNFs. The equivalent stress plot collapsed the data points from all of the SNF samples into a single zone. A detailed examination revealed that, at the same stress level, fatigue lives display a descending order as follows: H. B. Robinson Nuclear Power Station (HBR), LMK, and mixed uranium-plutonium oxide (MOX). Just looking at the strain, LMK fuel has a slightly longer fatigue life than HBR fuel, but the difference is subtle. The third portion of this report provides finite element analysis (FEA) dynamic deformation simulation of SNF assemblies . In a horizontal layout under NCT, the fuel assembly’s skeleton, which is formed by guide tubes and spacer grids, is the primary load bearing apparatus carrying and transferring vibration loads within an SNF assembly. These vibration loads include interaction forces between the SNF assembly and the canister basket walls. Therefore, the integrity of the guide tubes and spacer grids critically affects the vibration intensity of the fuel assembly during transport and must be considered when developing the multipurpose purpose canister (MPC) design for safe SNF transport.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Techno-Economic Analysis Using REopt for Community Solar on Multifamily Affordable Housing Properties [Slides]

Multifamily affordable housing (MFAH) providers can identify and prioritize properties in their portfolios for which community solar development is feasible by following portfolio screening steps in a process outlined by NREL. Once MFAH providers have identified the most feasible sites, they can conduct more detailed analyses for a select number of sites to assess how distributed energy resources such as solar plus storage can help them meet their goals. The step is completed using NREL's REopt (https://reopt.nrel.gov/tool), a free techno-economic optimization model that determines DER sizes and dispatch strategies that minimize the life cycle cost of energy at a site. This presentation describes how to perform this step using REopt to help MFAH providers answer questions such as: What size solar PV system will result in the most energy bill savings at this site? What size solar-plus-storage system would be needed to power critical loads through a utility grid outage? What is the financial impact of rate switching, net metering, and/or meter aggregation? What percentage of the site's load can be offset with renewable energy? What are the emissions benefits of this renewable generation?

14 SOLAR ENERGY↗

Fast Primary Frequency Response Using Coordinated DER and Flexible Loads: Framework and Residential-Scale Demonstration: Preprint

Methods for supporting grid frequency stabilization using widespread flexible load and DER are becoming essential as the portion of synchronous generation decreases. This article develops a framework for providing fast primary frequency response that leverages deferrable loads and DER coordinated using high-speed measurements in real time to ensure that local objectives are met. The framework is demonstrated in a residential-scale experiment with four household appliances and an inverter. The effectiveness of an example load management algorithm is demonstrated using three underfrequency anomaly test cases. The experimental data corroborates that in all cases, the entire coordinated response, from detection and measurement of a frequency anomaly to completed coordinated net-load response, is completed within 143 ms (about 8.5 cycles).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling the Interaction Between Energy Efficiency and Demand Response on Regional Grid Scales: Preprint

With increasing penetration of intermittent renewable generation at grid and distributed scales, flexible building loads can provide significant system value and support the evolving needs of the grid. The growing value of load flexibility may complicate the traditional separation between energy efficiency (EE) and demand response (DR). EE measures may compete in some cases with a building’s DR capabilities but complement one another in other cases. EE can also increase or decrease the need for DR at the system level and change the availability of DR to meet system needs. In this study we present a bottom-up approach to modeling interactive effects between EE and DR in buildings within two regions of the US electricity grid. From a library of building simulation models for different buildings and climates, we synthesize system-level demand profiles and the impacts of potential future EE portfolios. Coupling the underlying building models with a database of DR-enabling technologies, we then compute the quantity of DR that can be delivered in each scenario. The results show that EE and DR interactions are largely driven by the timing of EE savings that are measure-specific and the coincidence with system peak demand that is region-specific. We also find that perspective of the impacts matters – for instance that some EE measures reduce the system need for DR but also reduce the DR potential. Our results imply that utility EE and DR programs developed without considering interactive effects may lead to increased grid-management challenges over the long term.

buildings↗

Smarter Grid Solutions | National Renewable Energy Laboratory: Active Management Integration: June 2015 - November 2016

This report presents the project results for the NREL INTEGRATE demonstration project: Active Network Management (ANM) Integration. Consistent with the INTEGRATE program's objective of increasing the grid's clean energy hosting capacity and providing grid services in a holistic manner, the project demonstrated the use of ANM to enable very high penetrations of solar PV and wind energy systems. Results obtained using a representative North American distribution system showed ANM's autonomous distributed control doubled the interconnected wind and solar systems by managing thermal and voltage constraints in real-time. These generators flexibly interconnected to the grid via ANM's end-to-end control architecture, and were managed and coordinated with other smart distributed energy resources (DER; e.g. EVs, battery ESS, controllable load) to unlock the grid's dynamic hosting capacity. As a smart grid application to standardize grid integration of diverse renewable generation sources, ANM provides the industry with a scalable, cost-effective alternative to traditional transmission and distribution (T&D) reinforcements. This project considered three use cases of the application of ANM: a Smart Home demonstration of ANM control of residential scale devices (PV, EV, and battery ESS); a Smart Campus demonstration of high penetration megawatt-scale DER (PV, EVs, battery ESS, and controllable load) behind a single point-of-common-coupling (PCC), and a Smart Distribution demonstration that combined prior use cases along with additional community/utility-scale DER at very high aggregate penetration levels. The Smart Distribution use case provided an integrated perspective of ANM across all distribution grid DER device scales (incorporating aggregated Smart Homes and the Smart Campus) in order to showcase how these devices can support smart grid services to manage DER related constraints in a safe and reliable manner; and likewise how ANM integrates with grid modernization initiatives. The ANM system was deployed in NREL's Energy Systems Integration Facility (ESIF), and project industry advisors attended an on-site demonstration and a set of workshops in order to review project outcomes and evaluate the relevance of ANM for increasing the grid hosting capacity. The outcomes of this effort include an assessment of opportunities for field deployment of ANM to address existing interconnection challenges, as well as consolidating project advisor suggestions for investment in ANM and potential future pilots for more advanced schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Interactve Efficient Buildings Technical Report Series: Lighting and Electronics

Through its grid-interactive efficient building (GEB) research, the DOE Building Technologies Office seeks to build on existing energy-efficiency efforts and develop technological capabilities to optimize the interplay between building loads and the electric grid. This report analyzes connected lighting systems and consumer electronics/IT equipment technologies. All lighting technologies are assumed to be lighting-emitting diode (LED) or organic LED (OLED) technologies. These technologies are analyzed in two separate sections and the evaluations are not meant to be comparable to each other or other building technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine Learning-Based Identification of the Interface Regions for Coupling Local and Nonlocal Models

Local-nonlocal coupling approaches provide a means to combine the computational efficiency of local models and the accuracy of nonlocal models. However, the coupling process can be challenging, requiring expertise to identify the interface between local and nonlocal regions. Here, this study introduces a machine learning-based approach to automatically detect the regions in which the local and nonlocal models should be used. The method uses loading functions evaluated at grid points to decide the model selection at those points. Training of the networks is based on datasets provided by classes of loading functions for which reference coupling configurations are computed using accurate coupled solutions, where accuracy is measured in terms of the relative error between the solution to the coupling approach and the solution to the nonlocal model. We study two approaches that vary in data structure. The first, the full-domain input data approach, uses the entire load vector and outputs a complete label vector, performing a global classification. The second, a window-based approach, processes loads into windows and addresses the problem as a node-wise classification where each window's central point is classified individually. The classification problems are solved via deep learning algorithms based on convolutional neural networks. The performance of these approaches is studied on one-dimensional numerical examples using F1-scores and accuracy metrics. Notably, the windowing approach achieves an accuracy of 0.96 and an F1-score of 0.97, highlighting its potential to automate coupling processes effectively and enhance computational efficiency in material science applications.

97 MATHEMATICS AND COMPUTING↗

Using Micro-Synchrophasor Data for Advanced Distribution Grid Planning and Operations Analysis

This report reviews the potential for distribution-grid phase-angle data that will be available from new micro-synchrophasors (µPMUs) to be utilized in existing distribution-grid planning and operations analysis. This data could augment the current diagnostic capabilities of grid analysis software, used in both planning and operations for applications such as fault location, and provide data for more accurate modeling of the distribution system. µPMUs are new distribution-grid sensors that will advance measurement and diagnostic capabilities and provide improved visibility of the distribution grid, enabling analysis of the grid’s increasingly complex loads that include features such as large volumes of distributed generation. Large volumes of DG leads to concerns on continued reliable operation of the grid, due to changing power flow characteristics and active generation, with its own protection and control capabilities. Using µPMU data on change in voltage phase angle between two points in conjunction with new and existing distribution-grid planning and operational tools is expected to enable model validation, state estimation, fault location, and renewable resource/load characterization. Our findings include: data measurement is outstripping the processing capabilities of planning and operational tools; not every tool can visualize a voltage phase-angle measurement to the degree of accuracy measured by advanced sensors, and the degree of accuracy in measurement required for the distribution grid is not defined; solving methods cannot handle the high volumes of data generated by modern sensors, so new models and solving methods (such as graph trace analysis) are needed; standardization of sensor-data communications platforms in planning and applications tools would allow integration of different vendors’ sensors and advanced measurement devices. In addition, data from advanced sources such as µPMUs could be used to validate models to improve/ensure accuracy, providing information on normally estimated values such as underground conductor impedance, and characterization of complex loads. Although the input of high-fidelity data to existing tools will be challenging, µPMU data on phase angle (as well as other data from advanced sensors) will be useful for basic operational decisions that are based on a trend of changing data.

25 ENERGY STORAGE↗

Hardware-in-the-Loop (HIL) Simulations for Smart Grid Impact Studies: Preprint

Hardware-in-the-loop (HIL) simulation is increasingly employed in power engineering as more inverter-based generation and smart appliances are connected to the electric grid. HIL techniques allow for co-simulation of analytical models with actual devices whose complex behavior is computationally inefficient or difficult to capture. It also allows for testing of the behavior of these devices under adverse conditions that only occur rarely in the field, but that are important to evaluate. An overview of how HIL simulation has been used to date is provided. This paper further proposes that HIL simulation should play an important role in evaluating new control strategies, especially at the distribution level, that are being proposed to allow for continued affordable and reliable operation of the electric grid with the introduction of these new technologies. It presents a new capability that was developed to enable evaluation of interactions between residential loads and the smart grid: smart home hardware-in-the-loop. The paper includes results from an HIL simulation that incorporates multiple technologies and controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗