Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

NASA DOD Lead Free Electronics Project

The primary'technical objective of this project is to undertake comprehensive testing to generate information on failure modes/criteria to better understand the reliability of: Packages (e.g., Thin Small Outline Package [TSOP], Ball Grid Array [BGA], Plastic Dual In-line Package [PDIPD assembled and reworked with lead-free alloys Packages (e.g., TSOP, BGA, PDIP) assembled and reworked with mixed (lead/lead-free) alloys.

Kessel, Kurt R.↗

Verification of Unstructured Grid Adaptation Components

Adaptive unstructured grid techniques have made limited impact on production analysis workflows where the control of discretization error is critical to obtaining reliable simulation results. Recent progress has matured a number of independent implementations of flow solvers, error estimation methods, and anisotropic grid adaptation mechanics. Known differences and previously unknown differences in grid adaptation components and their integrated processes are identified here for study. Unstructured grid adaptation tools are verified using analytic functions and the Code Comparison Principle. Three analytic functions with different smoothness properties are adapted to show the impact of smoothness on implementation differences. A scalar advection-diffusion problem with an analytic solution that models a boundary layer is adapted to test individual grid adaptation components. Laminar flow over a delta wing and turbulent flow over an ONERA M6 wing are verified with multiple, independent grid adaptation procedures to show consistent convergence to fine-grid forces and a moment. The scalar problems illustrate known differences in a grid adaptation component implementation and a previously unknown interaction between components. The wing adaptation cases in the current study document a clear improvement to existing grid adaptation procedures. The stage is set for the infusion of verified grid adaptation into production fluid flow simulations.

Park, Michael A.↗

Verification of Unstructured Grid Adaptation Components

Adaptive unstructured grid techniques have made limited impact on production analysis workflows where the control of discretization error is critical to obtaining reliable simulation results. Recent progress has matured a number of independent implementations of flow solvers, error estimation methods, and anisotropic grid adaptation mechanics. Known differences and previously unknown differences in grid adaptation components and their integrated processes are identified here for study. Unstructured grid adaptation tools are verified using analytic functions and the Code Comparison Principle. Three analytic functions with different smoothness properties are adapted to show the impact of smoothness on implementation differences. A scalar advection-diffusion problem with an analytic solution that models a boundary layer is adapted to test individual grid adaptation components. The scalar problems illustrate known differences in a grid adaptation component implementation and a previously unknown interaction between components. Laminar flow over a delta wing is verified with multiple, independent grid adaptation procedures to show consistent convergence to fine-grid forces and pitching moment.

Park, Michael A.↗

Enabling Universal Access to Power on the Lunar Surface

The National Aeronautics and Space Administration (NASA) Artemis Missions will return human astronauts to the lunar surface, demonstrate technologies that establish a sustained presence on the lunar surface and enable human missions to Mars, and help create a lunar commercial economy. Creating a sustained permanent presence on the lunar surface will require access to continuous and highly reliable power to support mission needs. During Artemis, lunar surface operations will evolve and grow over time (years), requiring an increase in the amount of power needed (100s of kW) and distance that the power must be transmitted (up to 10 km during early Artemis missions). A lunar commercial economy is likely to exceed this power demand to the MW level and distance in the 100s of km. This increased distance and demand for highly reliable power drives the need to create an electric power grid by connecting localized lunar power systems (e.g., habitats, in-situ resource utilization plants, etc.), each containing one or more loads and/or sources. Developing a lunar surface power grid will allow lunar surface operations to resemble electrical utility operations on Earth; it allows power to be generated where it is convenient and allows power to be consumed where it is convenient and required. A lunar surface electric power grid will facilitate the growth of a lunar commercial economy because it provides a means to connect new loads to an existing electrical power system. A common standardized interface to the grid and a set of standardized voltages is required to take full advantage of the benefits of an electric power grid, similar to the terrestrial power grid. NASA Glenn Research Center is leading an effort to create universal access to power through the development of the Universal Modular Interface Converter (UMIC). The UMIC is designed to have a common interface that connects sources and loads compliant with the International Space Power System Interoperability Standard (ISPSIS) to a higher voltage AC transmission system or power grid. This presentation will further discuss the evolution of power during the Artemis missions, challenges associated with creating a sustained presence on the lunar surface, progress made on the UMIC, and future opportunities for technology development and standards.

space power systems↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems: Preprint

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Guidance for Grid Resilience Decisions in Rural Minnesota

This report assesses the hazard landscape of the state of Minnesota, identifies weather hazards that are most impactful to the distribution system, includes a statewide assessment of household access to services dependent on reliable power, reviews resilience planning activities of electric utilities in Minnesota, and presents analysis of distribution grid performance in the face of extreme weather events with data from seven electric cooperatives dispersed throughout outstate Minnesota. This information is synthesized to provide considerations for resilience investment prioritization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Natural Hazard Forecast Alert Grid Risk System

Weather events cause most power outages. Often, we even get notifications on our phones to take cover or be prepared for an imminent event. If electric grid utilities had a similar warning that also included probable scenarios and the equipment involved, they could prepare and minimize the effects. Idaho National Laboratory had a project with the U.S. Department of Energy’s Cybersecurity, Energy Security, and Emergency Response program to develop a grid alert application that receives messages from the existing emergency alert system, filters and determines components possibly affected by the emergency event, calculates probable scenarios using MASTERRI (Modeling And Simulation for Targeted Reliability and Resilience Improvement). For high-risk events, the application can then send alert links to subscribed electric distribution utility operations staff to allow them to see and evaluate the scenarios and the impact in a web based interactive map tool. This proof of concept application used data from utilities and organizations, such as the international regulatory body North American Electric Reliability Corporation, which have complied historical failure data of elements that comprise the U.S. electric grid. Nominal failure rates are obtained from this data. To make this tool possible, estimated failure rates were calculated for different component types given the alert type, severity, and location. Historic weather-related grid element failures were correlated with historic weather events from the Integrated Public Alert & Warning System. These correlated events and failures are used along with Bayesian updates from the historical norms to provide a modified failure rate for grid elements in the alert areas and calculate probable scenarios. Working with an industry collaborator, actual grid models and data were used for demonstration cases. This report outlines the work performed for this project.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Integrated multimodel analysis reveals achievable pathways toward reliable, 100% renewable electricity for Los Angeles

Climate change has prompted many communities to set targets for carbon-free power supplies, but they often lack data-driven strategies to achieve them. We present a comprehensive analysis of an entirely renewable electric power system that can maintain operating reliability and resource adequacy using detailed models of the city of Los Angeles power grid. In consultation with the operating utility, the Los Angeles Department of Water and Power (LADWP), and the local community, we develop four supply scenarios across three demand projections to analyze which types of infrastructure and operational changes would achieve reliable electricity at least cost. We find that a reliable, 100%-renewable power system yielding more than $1 billion annually in health and climate co-benefits is achievable. Solar can supply most future energy needs, while combustion turbines that use renewable, storable carbon-neutral fuels are key to maintaining reliability. This study provides a replicable methodology that other jurisdictions globally can follow.

14 SOLAR ENERGY↗

Reliability of CCGA and PBGA assemblies

Area Array Packages (AAPs) with 1.27 mm pitch have been the packages of the choice for commercial applications; they are now started to be implemented for use in military and aerospace applications. Thermal cycling characteristics of plastic BGA (PBGA) and CSP assemblies, because of their wide usage for commercial applications, have been extensively reported in literature. Thermal cycling represents the on-off environmental condition for most electronic products and therefore is a key factor that defines reliability.

stakes↗

Operation and Control of Electric Vehicle Charger with Enhanced Dynamic Performance Under Non-Ideal Grid Voltage Condition

This paper presents a three-phase electric vehicle charger connected to the grid, featuring multiple boost converters on the DC side, specifically designed to ensure smooth, oscillation-free power transfer during unsymmetrical voltage sags. Precise control mechanisms are implemented on the boost converter side to regulate both voltage and current on the electric vehicle side, thereby maintaining optimal charging conditions. The control architecture for both the grid-connected and boost converter components is based on the Lyapunov energy function, which is employed to achieve superior dynamic performance and stability. The system's robustness and reliability are demonstrated through its ability to maintain stable operation and efficient power transfer despite fluctuations in grid conditions. Furthermore, the implementation of Lyapunov-based control ensures rapid response and minimal energy loss, enhancing the overall efficiency of the system. To validate the effectiveness of this approach, a comprehensive model of the system was developed and tested using MATLAB/Simulink, with detailed computer simulations conducted across various significant case studies.

DC-DC boost converter↗

Body of Knowledge (BOK) for Leadless Quad Flat No-Lead/Bottom Termination Components (QFN/BTC) Package Trends and Reliability

Bottom terminated components and quad flat no-lead (BTC/QFN) packages have been extensively used by commercial industry for more than a decade. Cost and performance advantages and the closeness of the packages to the boards make them especially unique for radio frequency (RF) applications. A number of high-reliability parts are now available in this style of package configuration. This report presents a summary of literature surveyed and provides a body of knowledge (BOK) gathered on the status of BTC/QFN and their advanced versions of multi-row QFN (MRQFN) packaging technologies. The report provides a comprehensive review of packaging trends and specifications on design, assembly, and reliability. Emphasis is placed on assembly reliability and associated key design and process parameters because they show lower life than standard leaded package assembly under thermal cycling exposures. Inspection of hidden solder joints for assuring quality is challenging and is similar to ball grid arrays (BGAs). Understanding the key BTC/QFN technology trends, applications, processing parameters, workmanship defects, and reliability behavior is important when judicially selecting and narrowing the follow-on packages for evaluation and testing, as well as for the low risk insertion in high-reliability applications.

Ghaffarian, Reza↗

Body of Knowledge (BOK) for Leadless Quad Flat No-Lead/bottom Termination Components (QFN/BTC) Package Trends and Reliability

Bottom terminated components and quad flat no-lead (BTC/QFN) packages have been extensively used by commercial industry for more than a decade. Cost and performance advantages and the closeness of the packages to the boards make them especially unique for radio frequency (RF) applications. A number of high-reliability parts are now available in this style of package configuration. This report presents a summary of literature surveyed and provides a body of knowledge (BOK) gathered on the status of BTC/QFN and their advanced versions of multi-row QFN (MRQFN) packaging technologies. The report provides a comprehensive review of packaging trends and specifications on design, assembly, and reliability. Emphasis is placed on assembly reliability and associated key design and process parameters because they show lower life than standard leaded package assembly under thermal cycling exposures. Inspection of hidden solder joints for assuring quality is challenging and is similar to ball grid arrays (BGAs). Understanding the key BTC/QFN technology trends, applications, processing parameters, workmanship defects, and reliability behavior is important when judicially selecting and narrowing the follow-on packages for evaluation and testing, as well as for the low risk insertion in high-reliability applications.

MLF↗

Preliminary Analysis of Nuclear-Powered Data Center Scenarios

This report provides a comprehensive analysis of the potential for nuclear energy to meet the growing energy demands of data centers (DCs). It evaluates the technical, economic, and socio-environmental implications of coupling Nuclear Power Plants (NPPs) with DCs, providing initial responses to several key research questions: What is the potential increased energy demand from DCs in the U.S., in the short, medium and long term? The U.S. is experiencing a rapid increase in energy demand from DCs, with projections indicating a total increase of 24-74 GWy(e) by 2028. Meeting this demand with nuclear energy would require 27–85 GWe of installed capacity. While this surge is expected to slow in the long term, the DC industry needs reliable, scalable, and clean energy sources. How much nuclear capacity can be deployed to meet DC demand and in which timeframe? Several pathways for increasing nuclear capacity were identified, including uprates, restarts of recently retired reactors, power purchase agreements with existing fleet, and new construction. Approximately 20‒28 GWe of nuclear capacity could be dedicated to DCs by the early 2030s. How much High Assay Low Enriched Uranium (HALEU) would be needed to support some nuclear deployment scenarios for DCs? Meeting the deployment targets announced by Google and Amazon for the Kairos Power Fluoride-Salt-Cooled High-Temperature Reactor or KP-FHR (~500 MWe by 2035) and the Xe-100 (~1 GWe by 2040), respectively, requires ramping up 19.75% enriched HALEU production to ~6 t/yr by 2040. What types of nuclear energy/DC coupling options exist, and what are the different benefits/challenges? Five coupling options were analyzed, ranging from grid-connected configurations to colocated, behind-the-meter setups. Key design considerations include the proximity to high- and/or medium-voltage transmission lines, the desired internal fault tolerance, and the sources of alternative/backup power during outages. Each coupling option offers unique benefits and challenges in terms of reliability, system costs, regulation, timeline, etc. A list of NPP/DC deployment scenarios was developed, considering existing or newly built NPP or DC projects. Colocated DCs with new small modular reactors or large reactors on greenfield and brownfield sites are the focus of this report. What types of reactors, especially what size, may be incentivized by DCs? Reactor sizing optimization revealed that the ideal reactor size and number of units depend on DC demand, coupling configurations defined in this report, and other economic factors. Larger reactors are preferred for high-demand DCs and grid-connected systems, while larger number of smaller reactors are better suited for DC configurations without grid backup. Which sites may be compatible with co-located nuclear-powered DCs? Siting those projects is a complicated evaluation factoring local water resources, grid connection availability and reliability, IT infrastructure, local work force, proximity to population zones, etc. For this effort greenfield and brownfield sites such as retired coal-fired plants were used to evaluate this question. This evaluation is not meant to recommend any particular site but it highlights key siting criteria and demonstrates large-scale site availability. What are the socio-economic impacts of co-located nuclear-powered DCs? Those projects generate substantial economic benefits to the local economy, particularly in urban settings. Hyperscale DCs colocated with nuclear power plants (sized around 1 GW of power) can create nearly 1,700 jobs for annual operations and more than 7,300 jobs among the supply chain and local businesses as a result of increased household spending. Rural projects also provide significant benefits, but at lower magnitudes compared to urban deployments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Performance Computing Based EMT Simulation: Power Grid with IBRs

Electromagnetic transient (EMT) simulation of power grids with high-fidelity models of inverter-based resources (IBRs) is time-consuming and difficult to scale. The necessity for high-fidelity models of IBRs that incorporate the dynamics of individual inverters within IBRs has been showcased in recent studies. These studies focused on events with partial power reduction in each IBR during a transmission line fault in the power grid. These types of events have been documented in multiple North American Electric Reliability Council (NERC) reports in the past decade. It is imperative then to find solutions to speed-up EMT simulations and scale the size of the region with IBRs studied in EMT simulations. In this paper, a combination of numerical simulation algorithms with high-performance computing techniques are employed in discretization and linear solvers employed in the proposed RE-INTEGRATE EMT simulation platform for power grid with IBRs. For ease of scalability, modular and object-oriented programming is used as these techniques are implemented. Additionally, automation software is developed to convert legacy software codes to the proposed RE-INTEGRATE EMT simulation platform. Thereafter, this platform is evaluated on multi-core central processing units (CPUs). Finally, scale-up tests are performed to showcase the scalability that is possible.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

Different Damp-Heat-Induced Series Resistance Degradation Behaviors in Fielded Crystalline Silicon Photovoltaic Modules Due to Difference in Bill of Materials

This case study investigates mono-crystalline silicon modules from underperforming portions of a utility-scale photovoltaic power plant. Field-collected I-V curves and electroluminescence imaging suggested that increased series resistance was a primary factor driving module degradation. Selected modules were removed from the field for further analysis, including incremental damp heat accelerated testing, which confirmed a progression in series resistance degradation. Two distinct cell degradation behaviors became apparent during the investigation. Cross-sectional scanning electron microscopy (with elemental analysis) and scanning spreading resistance microscopy identified key differences between the two degradation mechanisms, primarily grid finger width and contact resistance. Additionally, the study highlights the reliability implications of retest requirements in International Electrotechnical Commission 61215 for material changes and how they may have mitigated the degradation observed at this site.

14 SOLAR ENERGY↗

Communities LEAP: Microgrids 101 [Slides]

Through the Communities Local Energy Action Program (LEAP), NREL is providing technical assistance to a coalition of stakeholders from Oakridge, Oregon. The coalition includes community-based non-profit organizations, the city government, the local utility, and others. Technical assistance provides analysis and information to support Oakridge stakeholders with their goals to increase energy reliability and resilience in the community, while promoting economic development. The Grid Resilience and Microgrids Learning Session was presented to the Oakridge coalition to provide foundational technical knowledge that can support decision-making about energy-related issues in the community.

24 POWER TRANSMISSION AND DISTRIBUTION↗