Search NASA⌕ Search

SEARCH · Search NASA

Results for “Group Contribution Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

SU-E-J-90: Lobar-Level Lung Ventilation Analysis Using 4DCT and Deformable Image Registration

Purpose: To assess regional changes in human lung ventilation and mechanics using four-dimensional computed tomography (4DCT) and deformable image registration. This work extends our prior analysis of the entire lung to a lobe-based analysis. Methods: 4DCT images acquired from 20 patients prior to radiation therapy (RT) were used for this analysis. Jacobian ventilation and motion maps were computed from the displacement field after deformable image registration between the end of expiration breathing phase and the end of inspiration breathing phase. The lobes were manually segmented on the reference phase by a medical physicist expert. The voxel-by-voxel ventilation and motion magnitude for all subjects were grouped by lobes and plotted into cumulative voxel frequency curves respectively. In addition, to eliminate the effect of different breathing efforts across subjects, we applied the inter-subject equivalent lung volume (ELV) method on a subset of the cohort and reevaluated the lobar ventilation. Results: 95% of voxels in the lung are expanding during inspiration. However, some local regions of lung tissue show far more expansion than others. The greatest expansion with respiration occurs within the lower lobes; between exhale and inhale the median expansion in lower lobes is approximately 15%, while the median expansion in upper lobes is 10%. This appears to be driven by a subset of lung tissues within the lobe that have greater expansion; twice the number of voxels in the lower lobes (20%) expand by > 30% when compared to the upper lobes (10%). Conclusion: Lung ventilation and motion show significant difference on the lobar level. There are different lobar fractions of driving voxels that contribute to the major expansion of the lung. This work was supported by NIH grant CA166703.

60 APPLIED LIFE SCIENCES↗

Dry cask radiation shielding validation and estimation of cask surface dose rate with MAVRIC during long-term storage

The dry storage cask became a semi-permanent solution for spent nuclear fuel since no permanent solution has been finalized over the past three decades. Considering the difficulty of deep geological repository projects in many aspects, prolonging the service life of dry casks longer than a few decades has become an option for spent nuclear fuel storage. It must be ensured that dry cask safety objectives, including radiation shielding, criticality safety, structure health, decay heat removal, and containment be fulfilled during the prolonged service life. This paper presents numerical modeling results of the radiation dose rate distribution on a TN-32 cask surface aged up to 300 years. The numerical modeling method was validated with measurement data, and the difference between the calculated results and measurement data in the total dose rate is 7%. The detailed radiation distribution variations over cask surfaces along the axial and radial directions for 300 years of storage were obtained, and their azimuthal angular dependence was established. The maximum total dose rate over the cask surfaces is less than 10 mrem/hour (9.258 ± 0.212 mrem/hour) after 40 years, and this outcome fulfills all dose rate requirements from 10 CFR 71.47(b). After 300 years of storage, the average total dose rates on the side surface and top surface are 0.150 ± 0.007mremmrem/hour and 0.057 ± 0.003mremmrem/hour, respectively, while the maxima are 0.601 ± 0.014 mrem/hour and 0.112 ± 0.006 mrem/hour, respectively. The variations in the fuel gamma ray, structure gamma ray, neutron and secondary gamma-ray contributions to the total dose rate are presented and analyzed in this work. The neutron and gamma-ray dose rate contributions by energy group are presented and analyzed at the cask top, mid-plane, and bottom at the selected storage times.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MO-D-BRD-00: Electronic Brachytherapy

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

MO-D-BRD-01: Clinical Implementation of An Electronic Brachytherapy Program for the Skin

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

MO-D-BRD-02: Radiological Physics and Surface Lesion Treatments with Electronic Brachytherapy

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-D-BRD-03: Radiobiology and Commissioning of Electronic Brachytherapy for IORT

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-D-BRD-04: NIST Air-Kerma Standard for Electronic Brachytherapy Calibrations

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

QCD–Gravity Double Copy in Regge Asymptotics: From \(2\rightarrow n\) Amplitudes to Radiation in Shockwave Collisions

This paper discusses multi-particle production in QCD and in gravity at ultrarelativistic energies, their double-copy relations, and strong parallels in emergent shockwave dynamics. Dispersive techniques are applied to derive the BFKL equation for multi-gluon production in Regge asymptotics. Identical methods apply in gravity and are captured by a gravitational Lipatov equation. The building blocks in both cases are Lipatov vertices and reggeized propagators satisfying double-copy relations; in gravity, Weinberg’s soft theorem is recovered as a limit of the Lipatov framework. BFKL evolution in QCD generates wee parton states of maximal occupancy characterized by an emergent semi-hard saturation scale. Renormalization group equations in the Color Glass Condensate (CGC) EFT describe wee parton correlations and their rapidity evolution. A shockwave picture of deeply inelastic scattering and hadron–hadron collisions follows, with multi-particle production described by Cutkosky’s rules in strong time-dependent fields. Gluon radiation in the CGC EFT has a double copy in gravitational shockwave collisions, with a similar correspondence applicable between gluon and graviton shockwave propagators. Possible extensions of this semi-classical double copy are outlined for computing multi-particle production in gravitational shockwave collisions, self-force and tidal contributions, and classical and quantum noise in the focusing of geodesics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Synthesis, structure, and electronic structure of CsAgGa{sub 2}Se{sub 4}

The new metal chalcogenide CsAgGa{sub 2}Se{sub 4} has been synthesized by means of the reactive flux method. It crystallizes in the space group P2{sub 1}/c of the monoclinic system with cell dimensions of a=11.225(2) A, b=7.9443(16) A, c=21.303(4) A, {beta}=103.10(3), V=1850.3(6), and Z=8. The structure contains two-dimensional {sub {infinity}}{sup 2}[AgGa{sub 2}Se{sub 4}]{sup -} layers separated by Cs{sup +} cations. The {sub {infinity}}{sup 2}[AgGa{sub 2}Se{sub 4}]{sup -} superlayer possesses a novel chain-sublayer-chain structure: a {sub {infinity}}{sup 2}[Ag{sub 2}GaSe{sub 6}]{sup 7-} sublayer, composed of {sub {infinity}}{sup 1}[AgGaSe{sub 4}]{sup 4-} chains that are further connected by Ag{sup +} ions, is sandwiched by parallel {sub {infinity}}{sup 1}[Ga{sub 3}Se{sub 8}]{sup 7-} chains to generate the {sub {infinity}}{sup 2}[AgGa{sub 2}Se{sub 4}]{sup -} superlayer. From a band structure calculation, the orbitals of all atoms have contributions to the bottoms of conduction bands, but the band gap is mainly determined by the 4s, 4p orbitals of Ga and Se. - Graphical Abstract: CsAgGa{sub 2}Se{sub 4} contains two-dimensional {sub {infinity}}{sup 2}[AgGa{sub 2}Se{sub 4}]{sup -} layers with a novel chain-sublayer-chain structure. Highlights: Black-Right-Pointing-Pointer New chalcogenide CsAgGa{sub 2}Se{sub 4} has been synthesized. Black-Right-Pointing-Pointer It possesses a new structure type with {sub {infinity}}{sup 2}[AgGa{sub 2}Se{sub 4}]{sup -} layers separated by Cs{sup +} cations. Black-Right-Pointing-Pointer {sub {infinity}}{sup 2}[AgGa{sub 2}Se{sub 4}]{sup -} consists of a {sub {infinity}}{sup 2}[Ag{sub 2}GaSe{sub 6}]{sup 7-} sublayer sandwiched by {sub {infinity}}{sup 1}[Ga{sub 3}Se{sub 8}]{sup 7-} chains. Black-Right-Pointing-Pointer Band gap of CsAgGa{sub 2}Se{sub 4} is mainly determined by the 4s, 4p orbitals of Ga and Se.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The new Zintl phases Eu{sub 21}Cd{sub 4}Sb{sub 18} and Eu{sub 21}Mn{sub 4}Sb{sub 18}

Crystals of two new Zintl compounds, Eu{sub 21}Mn{sub 4}Sb{sub 18} and Eu{sub 21}Cd{sub 4}Sb{sub 18} have been synthesized using the molten metal flux method, and their structures have been established by single-crystal X-ray diffraction. Both compounds are isotypic and crystallize in the monoclinic space group C2/m (No. 12, Z=4). The structures are based on edge- and corner-shared MnSb{sub 4} or CdSb{sub 4} tetrahedra, which make octameric [Mn{sub 8}Sb{sub 22}] or [Cd{sub 8}Sb{sub 22}] polyanions. Homoatomic Sb–Sb bonds are present in both structures. The Eu atoms take the role of Eu{sup 2+}cations with seven unpaired 4f electrons, as suggested by the temperature-dependent magnetization measurements. The magnetic susceptibilities of Eu{sub 21}Mn{sub 4}Sb{sub 18} and Eu{sub 21}Cd{sub 4}Sb{sub 18} indicate that both phases order anti-ferromagnetically with Néel temperatures of ca. 7 K and ca. 10 K, respectively. The unpaired 3d electrons of the Mn atoms in Eu{sub 21}Mn{sub 4}Sb{sub 18} do contribute to the magnetic response, however, the bulk magnetization measurements do not provide evidence for long-range ordering of the Mn spins down to 5 K. Electrical resistivity measurements suggest that both compounds are narrow band gap semiconductors. - Graphical abstract: Eu{sub 21}Mn{sub 4}Sb{sub 18} and Eu{sub 21}Cd{sub 4}Sb{sub 18} have complex monoclinic structures, based on MnSb{sub 4} and CdSb{sub 4} tetrahedra, both edge- and corner-shared. A perspective of the crystal structure is shown, as viewed along the b axis. Display Omitted - Highlights: • Eu{sub 21}Mn{sub 4}Sb{sub 18} and Eu{sub 21}Cd{sub 4}Sb{sub 18} are novel compounds in the respective ternary phase diagrams. • For both structures, the Zintl-Klemm rules are followed, and both are small gap semiconductors. • Eu{sub 21}Mn{sub 4}Sb{sub 18} and Eu{sub 21}Cd{sub 4}Sb{sub 18} are air-stable Zintl phases and could be new thermoelectric materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deployment of Performance Management Methodology as part of Liquid Waste Program at Savannah River Site - 12178

In 2009, Savannah River Remediation LLC (SRR) assumed the management lead of the Liquid Waste (LW) Program at the Savannah River Site (SRS). The four SRR partners and AREVA, as an integrated subcontractor are performing the ongoing effort to safely and reliably: - Close High Level Waste (HLW) storage tanks; - Maximize waste throughput at the Defense Waste Processing Facility (DWPF); - Process salt waste into stable final waste form; - Manage the HLW liquid waste material stored at SRS. As part of these initiatives, SRR and AREVA deployed a performance management methodology based on Overall Equipment Effectiveness (OEE) at the DWPF in order to support the required production increase. This project took advantage of lessons learned by AREVA through the deployment of Total Productive Maintenance and Visual Management methodologies at the La Hague reprocessing facility in France. The project also took advantage of measurement data collected from different steps of the DWPF process by the SRR team (Melter Engineering, Chemical Process Engineering, Laboratory Operations, Plant Operations). Today the SRR team has a standard method for measuring processing time throughout the facility, a reliable source of objective data for use in decision-making at all levels, and a better balance between engineering department goals and operational goals. Preliminary results show that the deployment of this performance management methodology to the LW program at SRS has already significantly contributed to the DWPF throughput increases and is being deployed in the Saltstone facility. As part of the liquid waste program on Savannah River Site, SRR committed to enhance production throughput of DWPF. Beyond technical modifications implemented at different location of the facility, SRR deployed performance management methodology based on OEE metrics. The implementation benefited from the experience gained by AREVA in its own facilities in France. OEE proved to be a valuable tool in order to support the enhancement program in DWPF by providing unified metrics to measure plant performances, identify bottleneck location, and rank the most time consuming causes from objective data shared between the different groups belonging to the organization. Beyond OEE, the Visual Management tool adapted from the one used at La Hague were also provided in order to further enhance communication within the operating teams. As a result of all the initiatives implemented on DWPF, achieved production has been increased to record rates from FY10 to FY11. It is expected that thanks to the performance management tools now available within DWPF, these results will be sustained and even improved in the future to meet system plan targets. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Metallophilic interactions from dispersion-corrected density-functional theory

In this article, we present the first comprehensive study of metallophilic (aurophilic) interactions using dispersion-corrected density-functional theory. Dispersion interactions (an essential component of metallophilicity) are treated using the exchange-hole dipole moment (XDM) model. By comparing against coupled-cluster benchmark calculations on simple dimers, we show that LC-ωPBE-XDM is a viable functional to study interactions between closed-shell transition metals and that it performs uniformly better than second-order Møller-Plesset theory, the basic computational technique used in previous works. We apply LC-ωPBE-XDM to address several open questions regarding metallophilicity, such as the interplay between dispersion and relativistic effects, the interaction strength along group 11, the additivity of homo- and hetero-metallophilic effects, the stability of [E(AuPH{sub 3}){sub 4}]{sup +} cations (E = N, P, As, Sb), and the role of metallophilic effects in crystal packing. We find that relativistic effects explain the prevalence of aurophilicity not by stabilizing metal-metal contacts, but by preventing gold from forming ionic structures involving bridge anions (which are otherwise common for Ag and Cu) as a result of the increased electron affinity of the metal. Dispersion effects are less important than previously assumed and their stabilization contribution is relatively independent of the metal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Clinical Value of [{sup 11}C]Methionine PET for Stereotactic Radiation Therapy With Intensity Modulated Radiation Therapy to Metastatic Brain Tumors

Purpose: This study investigated the clinical impact of {sup 11}C-labeled methionine-positron emission tomography (MET-PET) for stereotactic radiation therapy with intensity modulated radiation therapy (SRT-IMRT) in metastatic brain tumors. Methods and Materials: Forty-two metastatic brain tumors were examined. All tumors were treated with SRT-IMRT using a helical tomotherapy system. Gross tumor volume (GTV) was defined and drawn on the stereotactic magnetic resonance (MR) image, taking into account the respective contributions of MR imaging and MET-PET. Planning target volume (PTV) encompassed the GTV-PET plus a 2-mm margin. SRT-IMRT was performed, keeping the dose for PTV at 25-35 Gy in 5 fractions. The ratio of the mean value of MET uptake to the contralateral normal brain (L/N ratio) was plotted for the PTV prior to SRT-IMRT, at 3 months following SRT-IMRT, and at 6 months following SRT-IMRT. Tumor characteristic changes of MET uptake before and after SRT-IMRT were evaluated quantitatively, comparing them with MRI examination. Results: Mean {+-} SD L/N ratios were 1.95 {+-} 0.83, 1.18 {+-} 0.21, and 1.12 {+-} 0.25 in the pre-SRT-IMRT group, in the 3 months post-SRT-IMRT group, and in the 6 months post-SRT-IMRT group, respectively. Differences in the mean L/N ratio between the pre-SRT-IMRT group and the 3-month post-SRT-IMRT group and between the pre-SRT-IMRT group and the 6 month post-SRT-IMRT group were statistically significant, irrespective of MRI examination. Conclusions: We showed examples of metastatic lesions demonstrating significant decreases in MET uptake following SRT-IMRT. MET-PET seems to have a potential role in providing additional information, although MRI remains the gold standard for diagnosis and follow-up after SRT-IMRT. The present study is a preliminary approach, but to more clearly define the impact of PET-based radiosurgical assessment, further experimental and clinical analyses are required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Decadal Climate Prediction Project (DCPP) contribution to CMIP6

The Decadal Climate Prediction Project (DCPP) is a coordinated multi-model investigation into decadal climate prediction, predictability, and variability. The DCPP makes use of past experience in simulating and predicting decadal variability and forced climate change gained from the fifth Coupled Model Intercomparison Project (CMIP5) and elsewhere. It builds on recent improvements in models, in the reanalysis of climate data, in methods of initialization and ensemble generation, and in data treatment and analysis to propose an extended comprehensive decadal prediction investigation as a contribution to CMIP6 (Eyring et al., 2016) and to the WCRP Grand Challenge on Near Term Climate Prediction (Kushnir et al., 2016). The DCPP consists of three components. Component A comprises the production and analysis of an extensive archive of retrospective forecasts to be used to assess and understand historical decadal prediction skill, as a basis for improvements in all aspects of end-to-end decadal prediction, and as a basis for forecasting on annual to decadal timescales. Component B undertakes ongoing production, analysis and dissemination of experimental quasi-real-time multi-model forecasts as a basis for potential operational forecast production. Component C involves the organization and coordination of case studies of particular climate shifts and variations, both natural and naturally forced (e.g. the “hiatus”, volcanoes), including the study of the mechanisms that determine these behaviours. Furthermore, groups are invited to participate in as many or as few of the components of the DCPP, each of which are separately prioritized, as are of interest to them. The Decadal Climate Prediction Project addresses a range of scientific issues involving the ability of the climate system to be predicted on annual to decadal timescales, the skill that is currently and potentially available, the mechanisms involved in long timescale variability, and the production of forecasts of benefit to both science and society.

54 ENVIRONMENTAL SCIENCES↗

THE ABUNDANCES OF HYDROCARBON FUNCTIONAL GROUPS IN THE INTERSTELLAR MEDIUM INFERRED FROM LABORATORY SPECTRA OF HYDROGENATED AND METHYLATED POLYCYCLIC AROMATIC HYDROCARBONS

Infrared (IR) absorption spectra of individual polycyclic aromatic hydrocarbons (PAHs) containing methyl (-CH{sub 3}), methylene (CH{sub 2}), or diamond-like CH groups and IR spectra of mixtures of methylated and hydrogenated PAHs prepared by gas-phase condensation were measured at room temperature (as grains in pellets) and at low temperature (isolated in Ne matrices). In addition, the PAH blends were subjected to an in-depth molecular structure analysis by means of high-performance liquid chromatography, nuclear magnetic resonance spectroscopy, and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Supported by calculations at the density functional theory level, the laboratory results were applied to analyze in detail the aliphatic absorption complex of the diffuse interstellar medium at 3.4 μm and to determine the abundances of hydrocarbon functional groups. Assuming that the PAHs are mainly locked in grains, aliphatic CH {sub x} groups (x = 1, 2, 3) would contribute approximately in equal quantities to the 3.4 μm feature (N {sub CHx}/N {sub H} ≈ 10{sup –5}-2 × 10{sup –5}). The abundances, however, may be two to four times lower if a major contribution to the 3.4 μm feature comes from molecules in the gas phase. Aromatic ≅CH groups seem to be almost absent from some lines of sight, but can be nearly as abundant as each of the aliphatic components in other directions (N{sub ≅CH}/N {sub H} ∼< 2 × 10{sup –5}; upper value for grains). Due to comparatively low binding energies, astronomical IR emission sources do not display such heavy excess hydrogenation. At best, especially in protoplanetary nebulae, CH{sub 2} groups bound to aromatic molecules, i.e., excess hydrogens on the molecular periphery only, can survive the presence of a nearby star.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EXPERIMENTAL AND THEORETICAL STUDY ON THE INFRARED SPECTROSCOPY OF ASTROPHYSICALLY RELEVANT POLYCYCLIC AROMATIC HYDROCARBON DERIVATIVES 2- AND 9-VINYLANTHRACENE

We propose to evaluate the contribution of polycyclic aromatic hydrocarbon (PAH) molecules that carry side groups to the mid-infrared emission spectra. Within this framework, the IR absorption spectra of 2-vinylanthracene (2-VA) and 9-vinylanthracene (9-VA) were measured in Ar matrices at 12 K and in CsI and polyethylene pellets at room temperature. The laboratory spectra were analyzed with the support of simulations based on the density functional theory. For each PAH molecule, eight IR spectra were computed by combining the B3LYP functional with as many different basis sets, namely, 4-31G, 4-31G(d), 6-31G, 6-311G, 6-31G(d), 6-31G(d,p), 6-31+G(d,p), and 6-31++G(d,p). The comparison of the theoretical spectra with the laboratory data allowed us to determine the most suitable combinations for modeling the IR spectra of neutral PAH molecules that carry a vinyl side group. It was concluded from the examples of 2- and 9-VA that the optimum basis set is 6-31G unless a steric interaction has to be taken into account, in which case the optimum basis set is 6-31G(d). Thus, in the presence of such an interaction, the use of d-type polarization functions is recommended. We discuss the possibility for neutral vinyl-substituted PAHs to contribute to the mid-infrared emission spectra and find that their specific features do not match with the mid-infrared aromatic emission bands.

79 ASTRONOMY AND ASTROPHYSICS↗

Functional methods for Heavy Quark Effective Theory

We use functional methods to compute one-loop effects in Heavy Quark Effective Theory. The covariant derivative expansion technique facilitates the efficient extraction of matching coefficients and renormalization group evolution equations. This paper pro- vides the first demonstration that such calculations can be performed through the algebraic evaluation of the path integral for the class of effective field theories that are (i) constructed using a non-trivial one-to-many mode decomposition of the UV theory, and (ii) valid for non-relativistic kinematics. We discuss the interplay between operators that appear at intermediate steps and the constraints imposed by the residual Lorentz symmetry that is encoded as reparameterization invariance within the effective description. The tools presented here provide a systematic approach for computing corrections to higher order in the heavy mass expansion; precision applications include predictions for experimental data and connections to theoretical tests via lattice QCD. A set of pedagogical appendices comprehensively reviews modern approaches to performing functional calculations algebraically, and derives contributions from a term with open covariant derivatives for the first time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wildlife Densities and Habitat Use Across Temporal and Spatial Scales on the Mid-Atlantic Outer Continental Shelf. Final Report to the Department of Energy EERE Wind & Water Power Technologies Office

The Mid-Atlantic Baseline Studies Project helped address environmental barriers to offshore wind energy development in the mid-Atlantic region by providing regulators, developers, and other stakeholders with comprehensive baseline ecological data and analyses. Project funders and collaborators from a range of academic institutions, non-governmental organizations, federal agencies, foundations, and private companies came together to study bird, sea turtle, and marine mammal distributions, densities, and movements on the mid-Atlantic Outer Continental Shelf between 2012 and 2014. Specific project activities and goals included the following: (1) Conduct standardized surveys to quantify bird, sea turtle, and marine mammal densities seasonally and annually throughout the study region and identify important habitat use or aggregation areas. (2) Develop statistical models to help understand the drivers of wildlife distribution and abundance patterns. (3) Use individual tracking data for several focal bird species to provide information on population connectivity and individual movements that is complementary to survey data. (4) Identify species that are likely to be exposed to offshore wind energy development activities in the mid-Atlantic study area. (5) Develop U.S.-based technological resources and assessment methods for future monitoring efforts, including a comparison of high resolution digital video aerial surveys to boat-based surveys. (6) Help meet data needs associated with National Environmental Policy Act (NEPA), Marine Mammal Protection Act, and Endangered Species Act requirements, by contributing several years of data and analysis towards future Environmental Impact Statements. This report consists of six parts: Project overview (executive summary and Chapters 1-2); Examining wildlife distributions and relative abundance from a digital video aerial survey platform (Chapters 3-6); Examining wildlife distributions and abundance using boat-based surveys (Chapters 7-12); Integrating data across survey platforms (Chapters 13-19); Individual movements and habitat use for focal bird species (Chapters 20-25); and Nocturnal avian migration monitoring (Chapters 26-27). Boat-based and digital video aerial surveys each had specific advantages and disadvantages, but were largely complementary (Chapters 1, 5, 13-14). Digital aerial surveys were particularly useful for covering offshore areas at broad scales, where general distributions of taxonomic groups were a priority; boat surveys could provide more detailed data on species identities and behaviors, but were more limited in geographic scope due to their slower survey pace. The mid-Atlantic study area was important for wintering and breeding taxa, and its location also made it a key migratory corridor. There was considerable variation in species composition and spatial patterns by season, largely driven by dynamic environmental conditions (Chapters 12, 15, and 20-22). Habitat gradients in nearshore waters, however, were reliable influences on productivity and patterns of species distributions and abundance. Areas within about 30-40 km of the coast offshore of the mouths of Chesapeake and Delaware Bays, as well as to the south of Delaware Bay along the coast, were consistent hotspots of abundance and species diversity, regardless of survey methodology or analytical approach (Chapters 2, 12, 17). Inter-annual variation was substantial, and the importance of certain environmental variables in predicting animal distributions indicates that these species may well respond to future environmental shifts brought about by anthropogenic effects and climatic change. This study is an important first step, however, towards understanding how bird, marine mammal, and sea turtle populations in the mid-Atlantic may be exposed to offshore wind energy development and other anthropogenic activities. The results of this study provide insight to help address environmental permitting requirements for current and future offshore development projects, and serve as a starting point for more site-specific studies, risk analyses, and evaluation of potential measures to avoid and minimize those risks.

17 WIND ENERGY↗