Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT FLUX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Design of separate-effects In-Pile transient boiling experiments at the $\mathrm{TREAT}$ Facility

The cladding-to-coolant heat transfer during rapid power excursions, such as reactivity-initiated accidents, remains a crucial area of uncertainty in nuclear reactor safety. This uncertainty impacts the ability to accurately predict fuel performance behavior for these conditions. Improving our understanding of transient cladding-to-coolant heat transfer will enhance our ability to model design basis accidents and could increase design and improve safety margins for the current commercial fleet and advanced reactors. To address these issues, the Critical Heat Flux Static Environment Rodlet Transient Test Apparatus (CHF-SERTTA) experiment uses a novel approach with a borated stainless-steel heater rodlet that can replicate cladding temperatures experienced during a design-basis reactivity-initiated accident. The rodlet and experiment is instrumented to provide temperature and thermal-hydraulic conditions throughout the transient. The design of the rodlet allows for separate effect testing that eliminates complexities with a fuel and cladding specimen. We report the experiments have provided data that will be used to improve our understanding of boiling behavior, specifically critical heat flux, under transient conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heat pulse propagation and anomalous electron heat transport measurements on the optimized stellarator W7-X

The optimized stellarator Wendelstein 7-X (W7-X) is designed to have an approximately quasi-isodynamic magnetic configuration with reduced neoclassical transport in comparison to a classical stellarator, and turbulent transport is expected to be a significant source of anomalous heat transport across the plasma minor radius. The ion temperature gradient driven mode and the trapped electron mode (TEM) are thought to be responsible for the ion-scale turbulence in W7-X plasmas with volume averaged pressure below 1%. In this work, the electron temperature gradient driven turbulence is shown to be a good candidate for the explanation of the observed electron heat flux, in the inner plasma region where the density gradient is weak (in the outer region, a relatively stronger density gradient would drive additional TEM turbulence). Further, the experimental electron heat transport measured during electron cyclotron resonant heating power and plasma density scans is compared to neoclassical predictions, and the stiffness in the electron heat transport measured during transient transport experiments is presented in three common magnetic configurations of W7-X. In low-(β) plasma discharges, the stiffness in the electron heat flux, quantified by the ratio of the heat pulse to power balance diffusivity, ${\chi }_{\mathrm{e}}^{\mathrm{H}\mathrm{P}}/{\chi }_{\mathrm{e}}^{\mathrm{P}\mathrm{B}}$, is measured to be less than 2, and trend downwards with increasing collisionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal and structural analysis of a new WEST reciprocating probe head with Titanium-Zirconium-Molybdenum armour material

The Tore Supra tokamak was transformed into an X-point divertor fusion device in the frame of the WEST (W-for tungsten-Environment in Steady-state Tokamak) project, launched in support of the ITER tungsten divertor strategy. WEST began operation in 2017. A new reciprocating probe head, equipped with a Titanium-Zirconium-Molybdenum (TZM) heat shield, was recently built and operated on WEST during the C9 Campaign in early 2024. TZM was chosen as armour material for its very good mechanical properties between 700 °C and 1400 °C. This material was already extensively used for probe heads and other plasma facing components on the Alcator C-Mod tokamak. Here, this paper presents the design of the new WEST probe head. It is equipped with tungsten filaments that can be heated to emit electrons and provide a direct measurement of the plasma potential in the scrape-off layer, and it is also equipped with a pair of Langmuir probes. The probe plunges vertically into the plasma, reaches its maximum dive depth, then returns to its protected resting position in about 0.25 s. Thermal loads are calculated using as input the thermal properties of TZM and radial profiles of the heat flux measured in the past by other reciprocating probes, and scaled upwards to the expected heat loads in the WEST scrape-off layer. An analytical estimation of Electromagnetic (EM) loads will also be presented, as well as a thermal and structural analysis of the probe for 15 cycles at maximum plunge depth. The probe is observed by an infrared camera. Comparisons between the heat flux deduced by the Langmuir probe and the infrared radiance of the probe housing during plasma exposure are finally presented.

Diagnostic↗

Evaluation of Atmospheric Boundary Layer Height From Wind Profiling Radar and Slab Models and Its Responses to Seasonality of Land Cover, Subsidence, and Advection

In this study, we evaluated the effect of land cover, atmospheric subsidence, and advection on the annual dynamics of atmospheric boundary layer (ABL) height from two contrasting sites. The first site is the Walker Branch forest, a deciduous forest of temperate climate, complex topography, and cloudy summers. The second site is the Sacramento-San Joaquin River Delta, a site of Mediterranean climate, flat terrain on a local scale, and clear summers. After testing a new algorithm to calculate ABL heights from 915 MHz radar wind profilers, we evaluated a hierarchy of three slab models to recreate the diurnal and annual patterns of ABL growth. We found that the lower ABL heights in the Delta, particularly during late summer, are driven by the combined effects of increased atmospheric subsidence and marine air advection. In both sites, the annual pattern of ABL height was strongly correlated to total daily incoming radiation, and in the Delta, the annual pattern of ABL height closely followed the seasonal patterns of sensible heat flux from a mosaic of different land covers. A land composite of latent and sensible heat fluxes obtained through a meso-network of eddy covariance measurements and the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) mission resulted in higher model skill, thus showing that land cover heterogeneity is an important driver of ABL growth. To conclude, model simulations show that in the Delta, restoring agricultural land to wetlands with large open water areas could result in a reduction of ABL height during those months with low subsidence and advection.

54 ENVIRONMENTAL SCIENCES↗

Effect of edge plasma density on hot spot in LHCD plasma in EAST

Hot spots are a serious challenge limiting long pulse operation with lower hybrid current drive (LHCD) in tokamaks. Here, in order to mitigate hot spots in the guard limiter and improve LHCD capability, the effect of edge plasma density on inducing hot spots and current drive has been studied in EAST. The temperature in the guard limiter of the LH antenna, inducing hot spot directly, increases with edge density and LH power. Studies show that the hot spot is mainly ascribed to the heat flux in front of LH antenna. Further simulation indicates that such spots correspond to the peak position of edge density due to local LH electric field. In addition, due to the stronger parametric instability (PI) behavior in the case of higher edge density, the current drive capability decreases with edge density. Strike-point splitting behaviour appears as density increase, in agreement with current profiles in the edge region and the reduction of total driven current, suggesting that more power is deposited in the edge region, which then contributes more to hot spot formation. These studies offer one possible idea to optimize the edge density so as to satisfy the coupling, mitigate the heat flux in the guard limiter, and improve current drive capability in fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancement and Saturation of Near-Field Radiative Heat Transfer in Nanogaps between Metallic Surfaces

Near-field radiative heat transfer (NFRHT) between planar metallic surfaces was computationally explored over five decades ago by Polder and van Hove [Phys. Rev. B 4, 3303 (1971)]. These studies predicted that, as the gap size (d) between the surfaces decreased, the radiative heat flux first increases by several orders of magnitude until d is ~100 nm after which the heat flux saturates. However, despite both the fundamental and practical importance of these predictions, the combined enhancement and saturation of NFRHT at small gaps in metallic surfaces remains experimentally unverified. Here, we probe NFRHT between planar metallic (Pt, Au) surfaces and show that RHT rates can exceed the far-field rate by over a thousand times when d is reduced to ~25 nm. More importantly, we show that for small values of d RHT saturates due to the dominant contributions from transverse electric evanescent modes. Finally, our results are in excellent agreement with the predictions of fluctuational electrodynamics and are expected to inform the development of technologies such as near-field thermophotovoltaics, radiative heat-assisted magnetic recording, and nanolithography.

36 MATERIALS SCIENCE↗

A Nonequilibrium Thermodynamic Approach for Surface Energy Balance Closure

Abstract The surface energy imbalance, viz. that the turbulent dissipation does not fully account for available energy, has for long been an outstanding challenge in geophysical studies. In this study, we developed a novel approach based on nonequilibrium thermodynamics by representing the atmospheric boundary layer as a heat engine. In addition, an analytically tractable approach was used to estimate the ground heat flux based on Green's function approach, which in turn determines the available energy that drives the atmospheric heat engine. The proposed model was evaluated using heat fluxes measured by eight AmeriFlux eddy covariance towers with atmospheric temperature profiles recorded at adjacent radiosonde sites. The surface energy balance closure can be improved by ~11% over various landscapes, by including the estimated power production from the atmospheric heat engine.

Li, Peiyuan↗

Studies of the influence of heat pipe model and coupling strategy in heat pipe microreactor simulations using Sockeye

This work demonstrates various modeling approaches for thermally coupling heat pipes to a graphite monolithic block in a microreactor context, accounting for the presence of a gap. We show that heat pipe model selection has a significant impact on the transient behavior of a three-dimensional coupled microreactor assembly problem by comparing results obtained using different heat pipe models from the heat pipe code Sockeye. Additionally, we show that the choice of coupling strategy has significant consequences for both accuracy and performance. Furthermore, we found that our heat flux transfer strategy exhibited greater accuracy than our temperature transfer strategy, even when comparing a loose coupling of the heat flux transfer strategy to a tight coupling of the temperature transfer strategy. Although this research uses only theoretical test problems, it provides important insights in modeling thermal fluids phenomena in heat pipe microreactors.

Direwolf↗

Transient heat transfer of superfluid He 4 in nonhomogeneous geometries: Second sound, rarefaction, and thermal layer

Transient heat transfer in superfluid 4 He (He II) is a complex process that involves the interplay of the unique counterflow heat-transfer mode, the emission of second-sound waves, and the creation of quantized vortices. Many past researches focused on homogeneous heat transfer of He II in a uniform channel driven by a planar heater. Here, we report our systematic study of He II transient heat transfer in nonhomogeneous geometries that are pertinent to emergent applications. By solving the He II two-fluid equations of motion coupled with Vinen's equation for vortex-line density, we examine and compare the characteristics of transient heat transfer from planar, cylindrical, and spherical heaters in He II. Our results show that as the heater turns on, an outgoing second-sound pulse emerges, within which the vortex-line density grows rapidly. These vortices attenuate the second sound and result in a heated He II layer in front of the heater, i.e., the thermal layer. In the planar case where the vortices are created throughout the space, the second-sound pulse is continuously attenuated, leading to a thick thermal layer that diffusely spreads following the heat pulse. On the contrary, in the cylindrical and the spherical heater cases, vortices are created mainly in a thin thermal layer near the heater surface. As the heat pulse ends, a rarefaction tail develops following the second-sound pulse, in which the temperature drops. This rarefaction tail can promptly suppress the thermal layer and take away the deposited thermal energy. The effects of the heater size, heat flux, pulse duration, and temperature on the thermal-layer dynamics are discussed. We also show how the peak heat flux for the onset of boiling in He II can be studied in our model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strategies to mitigate urban heat: Effects on overheating and cloud formation

This study evaluates the effectiveness of various urban heat island (UHI) overheating mitigation strategies and their associated impacts on urban cloud dynamics and thermal processes. This study shows cloud-resolving and urban-resolving modeling results estimating the impact of Houston-Galveston heat mitigation scenarios and other resilient strategies contemplated in the Climate Adaptation Plan and Resilient Houston reports. The simulated scenarios include high intensity green rooftops, rooftop photovoltaic solar panels, enhanced urban irrigation, white/cool roofs and roads, and street trees. We contrast the adaptation scenarios against a present baseline case, a no city scenario and a larger and denser city as projected by the Houston-Galveston Area Council for 2045. During the daytime, cooling strategies such as cool roofs, cool roads, and green roofs exhibit superior performance in mitigating urban overheating. At night, enhanced urban irrigation emerges as the most effective cooling intervention. Cooling strategies significantly reduce sensible heat flux partitioning during the day, a process that reduces the uplift of air, suppressing the formation of urban shallow cumulus clouds. The extent of urban cloud mixing ratio is reduced in proportion to the decrease in sensible heating. Under the BEP-Tree scenario, which includes wind effects and evapotranspiration driven by a stomatal conductance model, urban trees demonstrated negligible environmental cooling effects and minimal urban cloud modifications. In contrast, the scenarios with more urban cooling and higher latent heat fluxes led to suppressed urban clouds. The net cooling effect achieved by the heat mitigation strategies is influenced by a combination of indirect processes, including the reduction of downwelling longwave radiation flux, due to reduced cloud presence, while some warming is attributed to a modest increase in shortwave radiation that offsets the cooling benefit. Additionally, reduced heat dissipation, weakened thermal gradients, and diminished vertical mixing over urban areas further moderate the cooling potential. These findings highlight the pivotal role of clouds and moist atmospheric processes in shaping the UHI effect and offer insights for designing more effective urban cooling strategies.

albedo changes↗

Turbulence spreading effects on the ELM size and SOL width

BOUT++ turbulence simulations were performed to investigate the impact of turbulence spreading on the edge localized mode (ELM) size and divertor heat flux width (λ q ) broadening in small ELM regimes. Here, this study is motivated by EAST experiments. BOUT++ linear simulations of a pedestal radial electric field (E r ) scan show that the dominant toroidal number mode (n) shifts from high-n to low-n, with a narrow mode spectrum, and the maximum linear growth rate increases as the pedestal E r well deepens. The nonlinear simulations show that as the net E × B pedestal flow increases, the pressure fluctuation level and its inward penetration beyond the top of the pedestal both increase. This leads to a transition from small ELMs to large ELMs. Both inward and outward turbulence spreading are sensitive to the scrape-off-layer (SOL) plasma profiles. The inward turbulence spreading increases for the steep SOL profiles, leading to increasing pedestal energy loss in the small ELM regime. The SOL width (λ q ) is significantly broadened progressing from the ELM-free to small ELM regime, due to the onset of strong radial turbulent transport. The extent of the SOL width (λ q ) broadening depends strongly on outward turbulence spreading. The fluctuation energy intensity flux Γ ε at the separatrix can be enhanced by increasing either pedestal E r flow shear or local SOL pressure gradient. The λ q is broadened as the fluctuation energy intensity flux Γ ε at the last close flux surface (LCFS) increases. Local SOL E × B flow shear will restrain outward turbulence spreading and the associated heat flux width broadening. Operating in H-mode with small ELMs has the potential to solve two critical problems: reducing the ELM size and broadening the SOL width.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance and flexibility improvements of Staged Pressurized Oxy-Combustion

Staged Pressurized Oxy-Combustion (SPOC) is a low-carbon coal combustion power technology being developed by Washington University in St. Louis (WUSTL). Oxy-combustion plants enable straightforward capture of carbon dioxide (CO 2 ) by removing most of the nitrogen in the combustion air prior to use, thereby burning fuel in near-pure oxygen instead of air, producing a flue gas containing primarily CO 2 and water. CO 2 capture at amounts > 90% is possible, often using cryogenic air separation. Oxy-combustion typically relies on flue gas recycle (FGR) to reduce the peak temperature and radiation that would otherwise occur in a fuel/oxygen only flame. SPOC reduces the peak temperatures of combustion by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given furnace module. This means that the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. Also, the process operates at an elevated gas-side pressure, reducing boiler size, enhancing heat transfer to achieve a compact boiler configuration as compared to an atmospheric-pressure boiler design, and allowing for recovery of the latent heat of the water from the flue gas at a temperature useful to the steam cycle. The resultant net efficiency of the system is over 3 percentage points greater than traditional atmospheric-pressure oxy-combustion, and 7 percentage points greater than the post combustion variant, representing a step-change improvement over first-generation capture technologies. To further develop the concept, WUSTL and the Electric Power Research Institute, Inc., organized a project with American Air Liquide, Inc., Doosan Babcock Limited, and the U.S. Department of Energy to investigate a practicable and workable boiler design. The team has identified the potential for enhanced process flexibility for controlling power generation over a wider load range than is normally available to conventional coal-fired power plants due to the staged nature of the heat release. With increasing intermittent renewable generator contribution, on-demand generators need to be highly flexible to participate in the future energy market, requiring extensive operation at reduced load. Conventional coal-fired steam generators typically face challenges in maintaining temperature control of the reheat steam and main steam at reduced loads. This results in inefficient operation, both in terms of the boiler efficiency and steam turbine heat rate. The results of this project show the SPOC process is capable of exceptional turndown, both on a stage basis and with the ability to bypass entire stages. Oxygen-supply flexibility was also investigated, as this is also a key consideration for the overall flexibility of the SPOC process given the operating constraints of conventional air separation units. A boiler design concept assessment was conducted and was focused on delivering compact and constructible design. The assessment checked appropriate tube operating metal temperatures at full load and at lower operating loads, balanced against the needs of efficient coal combustion, and the resultant slagging and ash environments. Combustion testing in the 100-kWth pressurized combustion test rig at WUSTL was carried out to validate the combustion, heat flux profiles and burnout at multiple loads. Combustion parameters investigated were flame stability, fuel burnout, ash composition, radiative heat flux, and temperature profiles. The results of these tests formed the basis of a full-scale boiler design that will encompass improvements in both efficiency and flexibility over conventional oxy-combustion processes. The air separation unit flexibility was investigated, and associated cost implications were addressed. Detailed economic assessment results for a 550 MWe net power block are also provided, allowing for a comparison against the baseline NETL oxy-combustion and post combustion capture cases.

20 FOSSIL-FUELED POWER PLANTS↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opal (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10 ..mu..m thick CuIOs with 4.8 ..mu..m diameter, covering silicon substrate of area 11 mm x 11 mm, with various heated areas ranging from 2.5 mm x 2.5 mm to 10 mm x 10 mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 Wcm -2 for 3-to-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5 mm x 2.5 mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 Wcm -2 with a superheat ~ 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition (ALD) aluminum oxide (Al 2 O 3 ) in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Power handling in a highly-radiative negative triangularity pilot plant

Abstract This work explores detailed power handling solutions for a class of high-field, highly-radiative negative triangularity (NT) reactors based around the MANTA concept (Rutherford et al 2024 Plasma Phys. Control. Fusion ). The divertor design is kept as simple as possible, opting for a standard divertor with standard leg length. FreeGS is used to create an equilibrium for the boundary region, prioritizing a short outer leg length of only ∼50 cm (∼40% of the minor radius). The UEDGE code package is used for the boundary plasma solution to track plasma temperatures and fluxes to the divertor targets. It is found that for P SOL = 25 MW and n sep = 0.96 × 10 20 m −3 , conditions consistent with initial core transport modeling, little additional power mitigation is necessary. For a fixed impurity fraction of just 0.13% Ne in the plasma, the peak heat flux density at the more heavily loaded outer targets falls to 7.8 MW m −2 , while the electron temperature T e remains just under 5 eV. Scans around the parameter space reveal that even at densities lower than in the primary operating scenario, P SOL can be increased up to 50 MW, so long as a slightly higher fraction of extrinsic radiator is used. With less than 1% neon (Ne) impurity content, the divertor still experiences less than 10 MW m −2 at the outer target. Design of the plasma-facing components includes a close-fitting vacuum vessel with a tungsten inner surface as well as FLiBe-carrying cooling channels fashioned into the VV wall directly behind the divertor targets. For the seeded heat flux profile, Ansys Fluent heat transfer simulations estimate that the outer target temperature remains at just below 1550 ∘ C. Initial scoping of advanced divertor designs shows that for an X-divertor, detachment of the outer target becomes much simpler, and plasma fluxes to the targets drop considerably with only 0.01% Ne content.

Miller, M. A. (ORCID:0000000265406533)↗

Recent advance progress of HL-3 experiments

Since the first plasma realized in 2020, a series of key systems on HL-3 (known as HL-2M before) tokamak have been equipped/upgraded, including in-vessel components (the first wall, lower divertor, and toroidal cryogenic/water-cooling/baking/glow discharge systems, etc.), auxiliary heating system of 11 MW, and 28 diagnostic systems (to measure the plasma density, electron temperature, radiation, magnetic field, etc.). Magnet field systems were commissioned firstly for divertor plasma discharges. During the 2nd experimental campaign of HL-3 tokamak, several great progresses have been achieved. Firstly, the successful operation with plasma current larger than 1 MA was achieved under a divertor configuration. Secondly, the advanced divertor concept with two distinct snowflake configurations was realized. It is found that the distribution of ion saturation current and heat flux on bottom plate becomes wide due to magnetic surface expansion, demonstrating the advantage of such configuration in the heat flux mitigation. In addition, using the combination of NBI, ECRH and LHCD, the standard sawtoothing high confinement mode of megampere plasma was firstly accessed on the HL-3. The successful commissioning of HL-3 is beneficial for the initial operation of ITER.

1 MA plasma↗

Thermal Damage Potential of Electric Vehicles

The main objective is to assess the risk that electric vehicle (EV) battery fires pose regarding thermal damage to other vehicles involved in a crash and to compare EV and internal combustion engine vehicle (ICEV) fires. A literature review of experimental data and statistics are used to perform the assessment. The findings indicate: (1) the heat flux emitted from an EV and ICEV fire are similar due to cabin materials being the main contributor to heat flux, (2) for ICEVs involved in a crash with fuel tank leakage, the thermal damage is significantly more than from an EV fire for equivalent fire durations, (3) the thermal damage potential from ICEV pool fires is at least 5 times higher than EV fires, and (4) EV and ICEV crashes resulting in a fire is about 0.002% and 0.2%, respectively. Thus, EV battery fires have a lower risk than ICEV fires.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling Land-Atmosphere Coupling at Cloud-Resolving Scale Within the Multiple Atmosphere Multiple Land (MAML) Framework in SP-E3SM

Representing subgrid variabilities of land surface processes and their upscaled effects is crucial for global climate modeling. Here, we implement a Multiple Atmosphere Multiple Land (MAML) framework in the superparamaterized version of E3SM (SP32 E3SM) to explicitly simulate the subgrid variabilities of land states and fluxes at cloud-resolving scale and their interactions with atmosphere. Comparing to the standard SP-E3SM in which all the atmospheric columns of the cloud resolving model embedded within the global atmospheric model grid interact with the same land surface (i.e., Multiple Atmosphere Single Land (MASL)), the impact of MAML on the strength of land-atmosphere coupling is limited, partly because the current implementation mainly facilitates one-way coupling between the cloud-resolving model and the land surface model. Despite such limitation, MAML increases the surface latent heat flux at the expense of sensible heat flux, and increases precipitation in India, Amazon, and Central Africa, reducing the model dry bias compared to the standard SP-E3SM. By employing a normalized gross moist stability (NGMS) diagnostic framework, we find that the increase in precipitation minus evaporation (PE) is primarily driven by the change in large-scale moisture convergence, particularly by the increase of water vapor in the lower atmosphere, while the local effect of total surface energy flux plays a minor role in the P-E change. More specifically, MAML changes the surface energy partitioning (evaporative fraction), increases the atmosphere water vapor, and further increases P-E by decreasing the NGMS. Finally, future development in the MAML framework is discussed.

54 ENVIRONMENTAL SCIENCES↗

Characterizing the plasma-induced thermal loads on a 200 kW light-ion helicon plasma source via infra-red thermography

The light-ion helicon plasma source of the Proto-MPEX linear plasma device has been recently upgraded to enable pulsed (0.5–1 s) operation up to 200 kW. The main objective of this work is to report on the plasma-induced surface heat fluxes incident on the helicon window during high power operation (60–150 kW net power) for the purpose of the design of the upcoming material plasma exposure eXperiment (MPEX). The IR imaging system and associated physics models for the extraction of surface heat fluxes are presented. Furthermore, experimental results demonstrate that the control of the plasma strike point via magnetic flux mapping and the use of dedicated limiters is effective at reducing the heat loads on the dielectric window. Moreover, it is found that the flux mapping must create a gap between the plasma and the dielectric window of at least the plasma radial decay length. Extrapolated to 200 kW net RF power, this mode of operation can reduce the power lost to the dielectric window by 33%. The results presented have direct application to the design of high-powered helicon plasma sources that operate in a steady state. Examples include linear divertor simulators such as MPEX, electric thrusters, negative ion sources for NBI and linear plasma–material interaction test stands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗