Search NASA⌕ Search

SEARCH · Search NASA

Results for “HOLLOW CATHODES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The discharge plasma in ion engine neutralizers: Numerical simulations and comparisons with laboratory data

Numerical simulations of neutralizer hollow cathodes at various operating conditions and orifice sizes are presented. The simulations were performed using a two-dimensional axisymmetric model that solves numerically an extensive system of conservation laws for the partially ionized gas in these devices. The results for the plasma are compared directly with Langmuir probe measurements. The computed keeper voltages are also compared with the observed values. Whenever model inputs and/or specific physics of the cathode discharge were uncertain or unknown additional sensitivity calculations have been performed to quantify the uncertainties. The model has also been employed to provide insight into recent ground test observations of the neutralizer cathode in NASA's evolutionary xenon thruster. It is found that a likely cause of the observed keeper voltage drop in a long duration test of the engine is cathode orifice erosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear spin dependence of the reaction of H{sub 3}{sup +} with H{sub 2}. II. Experimental measurements

The nuclear spin dependence of the chemical reaction H{sub 3}{sup +}+ H{sub 2}{yields} H{sub 2} +H{sub 3}{sup +} has been studied in a hollow cathode plasma cell. Multipass infrared direct absorption spectroscopy has been employed to monitor the populations of several low-energy rotational levels of ortho- and para-H{sub 3}{sup +} (o-H{sub 3}{sup +} and p-H{sub 3}{sup +}) in hydrogenic plasmas of varying para-H{sub 2} (p-H{sub 2}) enrichment. The ratio of the rates of the proton hop (k{sup H}) and hydrogen exchange (k{sup E}) reactions {alpha}{identical_to}k{sup H}/k{sup E} is inferred from the observed p-H{sub 3}{sup +} fraction as a function of p-H{sub 2} fraction using steady-state chemical models. Measurements have been performed both in uncooled (T{sub kin}{approx} 350 K) and in liquid-nitrogen-cooled (T{sub kin}{approx} 135 K) plasmas, marking the first time this reaction has been studied at low temperature. The value of {alpha} has been found to decrease from 1.6 {+-} 0.1 at 350 K to 0.5 {+-} 0.1 at 135 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards higher stability of resonant absorption measurements in pulsed plasmas

Possible ways to increase the reliability of time-resolved particle density measurements in pulsed gaseous discharges using resonant absorption spectroscopy are proposed. A special synchronization, called “dynamic source triggering,” between a gated detector and two pulsed discharges, one representing the discharge of interest and another being used as a reference source, is developed. An internal digital delay generator in the intensified charge coupled device camera, used at the same time as a detector, is utilized for this purpose. According to the proposed scheme, the light pulses from the reference source follow the gates of detector, passing through the discharge of interest only when necessary. This allows for the utilization of short-pulse plasmas as reference sources, which is critical for time-resolved absorption analysis of strongly emitting pulsed discharges. In addition to dynamic source triggering, the reliability of absorption measurements can be further increased using simultaneous detection of spectra relevant for absorption method, which is also demonstrated in this work. The proposed methods are illustrated by the time-resolved measurements of the metal atom density in a high-power impulse magnetron sputtering (HiPIMS) discharge, using either a hollow cathode lamp or another HiPIMS discharge as a pulsed reference source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isotope shifts and hyperfine structure of the Fe I 372-nm resonance line

We report measurements of the isotope shifts of the 3d{sup 6}4s{sup 2} a {sup 5}D{sub 4}-3d{sup 6}4s4p z {sup 5}F{sub 5}{sup o} Fe I resonance line at 372 nm between all four stable isotopes {sup 54}Fe, {sup 56}Fe, {sup 57}Fe, and {sup 58}Fe, as well as the complete hyperfine structure of that line for {sup 57}Fe, the only stable isotope having a nonzero nuclear spin. The field and specific mass shift coefficients of the transition have been derived from the data, as well as the experimental value for the hyperfine structure magnetic dipole coupling constant A of the excited state of the transition in {sup 57}Fe: A(3d{sup 6}4s4p z {sup 5}F{sub 5}{sup o})=81.69(86) MHz. The measurements were carried out by means of high-resolution Doppler-free laser saturated absorption spectroscopy in a Fe-Ar hollow cathode discharge cell using both natural and enriched iron samples. The measured isotope shifts and hyperfine constants are reported with uncertainties at the percent level.

74 ATOMIC AND MOLECULAR PHYSICS↗

Metal Ion Sources for Ion Beam Implantation

In this paper a theme touched upon the progress of metal ion sources devoted to metal ion beam implantation (MIBI) will be reviewed. A special emphasis will be given to some kinds of ion sources such as ECR, MEVVA and Cluster ion sources. A novel dual hollow cathode metal ion source named DUHOCAMIS will be introduced and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microdischarge extreme ultraviolet source with alkali metal vapor for surface morphology application

We have characterized a discharge-produced potassium plasma extreme ultraviolet (XUV) source. Potassium ions produced strong broadband emission around 40 nm with a bandwidth of 8 nm (full width at half-maximum). By comparison with atomic structure calculations, the broadband emission is found to be primarily due to 3d-3p transitions in potassium ions ranging from K{sup 2+} to K{sup 4+}. The current-voltage characteristics of the microdischarge suggest that the source operates in a hollow cathode mode and consequently the emitting ions may be localized on the potassium electrode surface at the hole into the capillary. To understand the spectral behavior from the potassium plasmas we compared the spectra from the discharge-produced plasma with that from a laser-produced plasma. The spectra from the different (electric and laser) plasmas at the same electron temperature (12 eV) were almost the same. This compact capillary XUV source with a photon energy of 30 eV is a useful XUV emission source for surface morphology applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Improved operation of the nonambipolar electron source

Significant improvements have been made to the nonambipolar electron source (NES), a radio frequency (rf) plasma-based electron source that does not rely on electron emission at a cathode surface [B. Longmier, S. Baalrud, and N. Hershkowitz, Rev. Sci. Instrum. 77, 113504 (2006)]. A prototype NES has produced 30 A of continuous electron current, using 2 SCCM (SCCM denotes cubic centimeter per minute at STP) Xe, 1300 W rf power at 13.56 MHz, yielding a 180 times gas utilization factor. A helicon mode transition has also been identified during NES operation with an argon propellant, using 15 SCCM Ar, 1000 W rf, and 100 G magnetic field. This NES technology has the ability to replace hollow cathode electron sources and to enable high power electric propulsion missions, eliminating one of the lifetime restrictions that many ion thrusters have previously been faced with.

43 PARTICLE ACCELERATORS↗

Low-energy, high-current, ion source with cold electron emitter

An ion source based on a two-stage discharge with electron injection from a cold emitter is presented. The first stage is the emitter itself, and the second stage provides acceleration of injected electrons for gas ionization and formation of ion flow (<20 eV, 5 A dc). The ion accelerating system is gridless; acceleration is accomplished by an electric field in the discharge plasma within an axially symmetric, diverging, magnetic field. The hollow cathode electron emitter utilizes an arc discharge with cathode spots hidden inside the cathode cavity. Selection of the appropriate emitter material provides a very low erosion rate and long lifetime.

43 PARTICLE ACCELERATORS↗

Capacitive radio frequency discharges with a single ring-shaped narrow trench of various depths to enhance the plasma density and lateral uniformity

Spatial structures of the electron density and temperature in ring-shaped hollow cathode capacitive rf plasma with a single narrow trench of 2 mm width have been investigated at various trench depths of D = 5, 8, 10, 12, and 15 mm. It is found that the plasma density is increased in the presence of the trench and that the radial profile of the plasma density has a peak around the narrow hollow trench near the cathode. The density becomes uniform further away from the cathode at all trench depths, whereas the electron temperature distribution remains almost uniform. The measured radial profiles of the plasma density are in good agreement with a theoretical diffusion model for all the trench depths, which explains the local density increase by a local enhancement of the electron heating. Under the conditions investigated, the trench of 10 mm depth is found to result in the highest plasma density at various axial and radial positions. The results show that the radial uniformity of the plasma density at various axial positions can be improved by using structured electrodes of distinct depths rather than planar electrodes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ribbon electron beam formation by a forevacuum plasma electron source

Results of the numerical analysis and experimental research on ribbon electron beam generation based on hollow cathode discharge at forevacuum gas pressure are presented. Geometry of the accelerating gap has modified. It lets us focus the ribbon electron beam and to transport it on a distance of several tens of centimeters in the absence of an axial magnetic field. The results of numerical simulations are confirmed by the experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accurate Frequency Determination of Vibration–Rotation and Rotational Transitions of SiH{sup +}

The fundamental {sup 28}SiH{sup +} ion has been characterized in a collaborative work, utilizing a hollow-cathode discharge laser spectrometer and a cryogenic ion trap spectrometer. Twenty-three vibration–rotation transitions around 4.75 μm have been detected with high accuracy. This has facilitated the first direct measurement of the pure rotational transition J=1←0 at 453056.3632(4) MHz in the trap spectrometer. The measured and accurately predicted transitions enable the search for this ion in space with IR and sub-mm telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

An overview of the Nuclear Electric Xenon Ion System (NEXIS) program

NASA is investigating high power, high specific impulse propulsion technologies that could enable ambitious flights such as multi-body rendezvous missions, outer planet orbiters and interstellar precursor missions. The requirements for these missions are much more demanding than those for state-of-the-art solar-powered ion propulsion applications. The purpose of the NEXIS program is to develop advanced ion thruster technologies that satisfy the requirements for high power, high specific impulse operation, high efficiency and long thruster life. The nominal design point for the NEXIS thruster is 20 kWe at a specific impulse of 7500 s with an efficiency over 78% and a xenon throughput capability of greater than 2000 kg. These performance and throughput goals will be achieved by applying a combination of advanced technologies including a large discharge chamber, erosion resistant carbon-carbon grids, an advanced reservoir hollow cathode and techniques for increasing propellant efficiency such as grid masking and accelerator grid aperture diameter tailoring. This paper provides an overview of the challenges associated with these requirements and how they are being addressed in the NEXIS program.

carbon-carbon grids↗

Comparative Study of Electric Field Measurement in Glow Discharges using Laser Optogalvanic Spectroscopy

The net electric field inside low-pressure glow discharges has been measured using laser optogalvanic spectroscopy of 1s2s {sup 1}S{sub 0}{yields}np{sup 1}P{sub 1} Rydberg series of atomic helium. Three different types of discharges, an inductively coupled RF discharge cell operating at 4 MHz, a homemade DC discharge cell and a commercial see-through hollow cathode lamp have been used for these studies. The Rydberg series terminates earlier in the high electric field discharge as compared to that in the low electric field discharge. The net electric field also produces shift and broadens the observed spectral lines especially in the high lying Rydberg transitions. The electric field has been determined from the series termination and also from the energy shift of the observed transitions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-stage plasma gun based on a gas discharge with a self-heating hollow emitter

The paper presents the results of tests of a new compact two-stage bulk gas plasma gun. The plasma gun is based on a nonself-sustained gas discharge with an electron emitter based on a discharge with a self-heating hollow cathode. The operating characteristics of the plasma gun are investigated. The discharge system makes it possible to produce uniform and stable gas plasma in the dc mode with a plasma density up to 3x10{sup 9} cm{sup -3} at an operating gas pressure in the vacuum chamber of less than 2x10{sup -2} Pa. The device features high power efficiency, design simplicity, and compactness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of two-channel prototype ITER vacuum ultraviolet spectrometer with back-illuminated charge-coupled device and microchannel plate detectors

A vacuum ultraviolet (VUV) spectrometer of a five-channel spectral system is designed for ITER main plasma impurity measurement. To develop and verify the system design, a two-channel prototype system is fabricated with No. 3 (14.4-31.8 nm) and No. 4 (29.0-60.0 nm) among the five channels. The optical system consists of a collimating mirror to collect the light from source to slit, two holographic diffraction gratings with toroidal geometry, and two different electronic detectors. For the test of the prototype system, a hollow cathode lamp is used as a light source. To find the appropriate detector for ITER VUV system, two kinds of detectors of the back-illuminated charge-coupled device and the microchannel plate electron multiplier are tested, and their performance has been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of the EUV emission of a metallic capillary discharge operated with argon ambient gas

In this work, the metallic capillary discharge is operated with two different ambients: air and argon. In the experiments reported here, the chamber is first evacuated to 10{sup −5} mbar. The discharge is initiated by the transient hollow cathode effect generated electron beam, with either air ambient or argon ambient at 10{sup −4} mbar. The bombardment of electron beam at the tip of the stainless steel anode gives rise to a metallic vapor, which is injected into the capillary and initiates the main discharge through the capillary. The EUV emission is measured for different discharge voltages for both conditions and compared. It is found that the metallic capillary discharge with argon ambientis able to produce higher EUV energy compared to that with air ambient.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IMPROVED DETERMINATION OF THE 1{sub 0}-0{sub 0} ROTATIONAL FREQUENCY OF NH{sub 3}D{sup +} FROM THE HIGH-RESOLUTION SPECTRUM OF THE {nu}{sub 4} INFRARED BAND

The high-resolution spectrum of the {nu}{sub 4} band of NH{sub 3}D{sup +} has been measured by difference frequency IR laser spectroscopy in a multipass hollow cathode discharge cell. From the set of molecular constants obtained from the analysis of the spectrum, a value of 262817 {+-} 6 MHz ({+-}3{sigma}) has been derived for the frequency of the 1{sub 0}-0{sub 0} rotational transition. This value supports the assignment to NH{sub 3}D{sup +} of lines at 262816.7 MHz recorded in radio astronomy observations in Orion-IRc2 and the cold prestellar core B1-bS.

74 ATOMIC AND MOLECULAR PHYSICS↗

HIGH-RESOLUTION FOURIER TRANSFORM SPECTROSCOPY OF Nb i IN THE NEAR-INFRARED

In this study, a Fourier Transform spectrum of Niobium (Nb) is investigated in the near-infrared spectral range from 6000 to 12,000 cm{sup −1} (830–1660 nm). The Nb spectrum is produced using a hollow cathode discharge lamp in an argon atmosphere. Both Nb and Ar spectral lines are visible in the spectrum. A total of 110 spectral lines are assigned to the element Nb. Of these lines, 90 could be classified as transitions between known levels of atomic Nb. From these classified Nb i transitions, 27 have not been listed in literature previously. Additionally, 8 lines are classified for the first time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗