Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat Generation Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Resolving the Heat Generated from ZrO 2 Atomic Layer Deposition Surface Reactions

Abstract In situ pyroelectric calorimetry and spectroscopic ellipsometry were used to investigate surface reactions in atomic layer deposition (ALD) of zirconium oxide (ZrO 2 ). Calibrated and time‐resolved in situ ALD calorimetry provides new insights into the thermodynamics and kinetics of saturating surface reactions for tetrakis(dimethylamino)zirconium(IV) (TDMAZr) and water. The net ALD reaction heat ranged from 0.197 mJ cm −2 at 76 °C to 0.155 mJ cm −2 at 158 °C, corresponding to an average of 4.0 eV/Zr at all temperatures. A temperature dependence for reaction kinetics was not resolved over the range investigated. The temperature dependence of net reaction heat and distribution among metalorganic and oxygen source exposure is attributed to factors including growth rate, equilibrium surface hydroxylation, and the extent of the reaction. ZrO 2 ‐forming surface reactions were investigated computationally using DFT methods to better understand the influence of surface hydration on reaction thermodynamics.

Bielinski, Ashley R.↗

Resolving the Heat Generated from ZrO 2 Atomic Layer Deposition Surface Reactions

Abstract In situ pyroelectric calorimetry and spectroscopic ellipsometry were used to investigate surface reactions in atomic layer deposition (ALD) of zirconium oxide (ZrO 2 ). Calibrated and time‐resolved in situ ALD calorimetry provides new insights into the thermodynamics and kinetics of saturating surface reactions for tetrakis(dimethylamino)zirconium(IV) (TDMAZr) and water. The net ALD reaction heat ranged from 0.197 mJ cm −2 at 76 °C to 0.155 mJ cm −2 at 158 °C, corresponding to an average of 4.0 eV/Zr at all temperatures. A temperature dependence for reaction kinetics was not resolved over the range investigated. The temperature dependence of net reaction heat and distribution among metalorganic and oxygen source exposure is attributed to factors including growth rate, equilibrium surface hydroxylation, and the extent of the reaction. ZrO 2 ‐forming surface reactions were investigated computationally using DFT methods to better understand the influence of surface hydration on reaction thermodynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of a composite flame retardant system on the flame retardancy and mechanical performance of epoxy resin adhesive

Abstract A flame‐retarded epoxy resin (ER) adhesive with strong flame retardancy and adhesion performance was prepared. The coated ammonium polyphosphate (MFAPP), melamine (MEL), and organic montmorillonite (OMMT) were mixed to prepare a composite flame retardant. It was subsequently blended with a toughened ER thoroughly and then the mixture was cured with polyamide. The resultant ER adhesive thermosets achieved UL‐94 V‐0 rating during vertical burning test, and the limiting oxygen index value was as high as 31.6%. The shear strength of the ER adhesive was 27.9 MPa when 25 wt% MFAPP/MEL/OMMT was introduced. Compared with the pure adhesive, the flame retardant epoxy adhesive maintained outstanding adhesion performance because of the good compatibility between the composite flame retardant additives and the toughened ER adhesive. Cone calorimetry tests indicated that the release of heat and smoke were obviously declined with the incorporation of the composite flame retardant system in comparison to pure ER adhesive thermoset. The investigation of flame retardant mechanism revealed that the composite MFAPP/MEL/OMMT flame retardant system stimulated the generation of highly expanded, integral, and strong char layer and the formed char layer exerted superior insulation effect during combusiton. The present work provided an alternative approach to prepare flame retardant ER adhesive with the similar excellent adhesive performance.

Li, Sheng↗

Flow and Heat Transfer Experimental Study for 3D-Printed Solar Receiving Tubes With Helical Fins at Internal Surface

3D-printing technology was applied to fabricate novel solar thermal collection tubes that have internal heat transfer enhancement fins and external surfaces with high solar absorptivity and low emissivity due to the ability to use different materials in one tube. Helical fins were selected to introduce circumferential flow and thus minimize the circumferential temperature difference of the tube that receives sunlight on one side. The structures of the helical fins were previously optimized from computational fluid dynamics (CFD) analysis with the objective of low entropy production rate by looking for high heat transfer coefficient and relatively lower pressure loss. High-temperature alloy, Inconel-718, was used to 3D print the tubes, which can resist corrosion for the potential application of molten chloride salts as heat transfer fluid. Experimental tests were carried out using water as the heat transfer fluid with the high heat flux provided by a tubular furnace heater. The tested Reynolds number ranges from 3.9 × 10 3 to 6.1 × 10 4 . Heat transfer coefficients of up to 2.8 times that of the smooth tube could be obtained with the expense of increased pressure loss compared to that of the smooth tube. The total system entropy generation can be significantly reduced due to the benefit of heat transfer enhancement that is greater than the expenses of the increased pressure loss. The experimental results of the 3D-printed heat transfer tubes confirmed the CFD-based results of fin optimization. Furthermore, the novel heat transfer tube is recommended for application in concentrating solar power systems.

14 SOLAR ENERGY↗

Conjugate Heat Transfer Modeling of Salt-Filled Fuel Pins for Stable Salt Reactor Safety Analysis

The Stable Salt Reactor (SSR) combines the proven structural design of light water reactor fuel assemblies with the inherent safety and fuel-cycle advantages of molten salt technology. In its fast reactor configuration, the SSR utilizes recycled nuclear waste as fuel, sealed within narrow salt-filled fuel pins and cooled by a surrounding liquid salt coolant. Reliable transfer of heat from the molten fuel salt through the cladding to the external coolant is essential for both reactor safety and performance. This work investigates conjugate heat transfer (CHT) in the SSR’s salt-filled fuel pins using NekRS, a high-fidelity spectral element computational fluid dynamics (CFD) solver. The analyses capture internal natural convection within the molten fuel salt and external forced convection in the coolant, under steady-state and transient operating conditions. Parametric studies evaluate how variations in reactor power and coolant flow rate influence heat transfer distributions and system response. The high-fidelity CFD results are time-averaged and post-processed for direct comparison with moderate-fidelity Reynolds-averaged Navier–Stokes (RANS) models, and for the development of reduced-order models within the SAM system code. These validated models support fast-running safety analyses of normal and off-normal transients, improving predictive capability for key safety margins. By integrating advanced CFD with system-level safety tools, this study strengthens the modeling framework for SSR design, reduces uncertainty in molten salt CHT simulations, and accelerates the engineering and licensing of next-generation nuclear reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Synergistic Heat Pumped Thermal Storage and Flexibly Carbon Capture System

As the U.S. grid evolves toward a lower-carbon system, fossil generation assets need to operate in energy markets with high variable renewable energy (VRE) penetration while also decreasing carbon emissions. Current carbon capture and storage (CCS) technologies suffer from high capital cost and an inability to operate flexibly during periods of oscillating demand. The ARPA-E FLECCS Program Phase 1 was created to fund designing and optimizing innovative CCS processes that enable flexibility on a high-VRE grid. To address this need, the Colorado State University (CSU) Team won funding to design a synergized system of thermal energy storage, power generation, and flexible carbon capture to enable breakthrough system performance that achieves an LCOE <$75/MWh with >99% capture rate. This approach will target new or existing natural gas combined cycle power plants. The proposed design utilizes novel hot and cold thermal energy storage (TES) technologies that store low-cost, off-peak electricity as thermal energy to power CCS solvent regeneration and boost plant output during periods of peak demand. The design provides an overall optimized net present value (NPV) by maximizing low carbon power to grid while prices are highest using Storworks Power’s concrete TES technology. The team also capitalizes on decades of ION Clean Energy’s (ION) development in low cost and flexible pioneering solvent technology, which has proven reductions in energy consumption and overall cost of 28% and 38%, respectively, compared with state-of-the-art CCS.

20 FOSSIL-FUELED POWER PLANTS↗

Hawaii Solar Desalination Project

This project built the world’s largest Forward Osmosis (FO) solar thermal desalination plant at the NELHA Hawaii Ocean Science and Technology Park for a high visibility “on sun” demonstration of seawater desalination for agricultural applications. The project included re-commissioning an existing 2MW micro-dish solar thermal array and coupling it to a next-generation 500m3/day FO system. The purpose of the project was to validate FO at commercial scale; to verify that the water produced is safe for potential downstream agricultural users; to gather data on capital cost, energy consumption and operating expense for the technology; and to demonstrate that FO can be successfully coupled to low-grade thermal resources. The plant implemented advancements in FO component technology, including hot nano-filtration, polymeric heat exchangers, draw solutions, and improved FO membranes, and operated from June 2022 to September 2023 - producing 30gpm of permeate water. Thermal energy was below 30kWh/m 3 during operation, establishing a new benchmark in thermal desalination technology, with recovery rates at times exceeding 65%, well above what commercial RO systems can achieve. Combining the plant capital cost (CAPEX) and the operating expenses (OPEX) yields a Levelized Cost of Water (LCOW) that is competitive with existing carbon-intensive technologies such as RO. The ability of the plant to operate from a renewable resource paves the way toward a low-carbon desalination future using low-grade thermal resources.

14 SOLAR ENERGY↗

The Impact of Anomalous Resistivity in Vacuum Contaminant Plasmas on the Electrothermal Instability

This manuscript presents an assessment of the electrothermal instability (ETI) in the presence of anomalous resistivity (AR) in vacuum contaminant plasmas (VCP) when applied to a magnetized liner inertial fusion (MagLIF)-like load.Pulsed-power driven dielectrically coated metallic liners, like in MagLIF, experience the current-driven electrothermal instability which occurs when a material’s resistivity changes with temperature and is subject to ohmic heating. Large scale pulsed-power facilities that use magnetically insulated transmission lines (MITL) have been shown to generate low-density plasma which enters the target chamber and coalesces around the load. The low-density high-temperature vacuum contaminant plasmas (VCP) can parasitically divert current from the load through causing a short in the anode-cathode gap inside the target chamber. Resistive magnetohydrodynamic (MHD) simulations of these VCP experience unphysical runaway ohmic heating due to under predicting the resistivity by using a purely collisional resistivity model.AR provides a physics-based way to address this runaway heating through increasing the resistivity in a proportional way with the drift speed. In this work, 1D simulations probe the effect that AR in VCP has on the magnetic diffusion rate, and 2D simulations show how this effect manifests in the nonlinear striation form of the ETI for a MagLIF-like load. Beryllium and aluminum dielectrically coated liners are used for the 1D and 2D simulations in this work. The1D simulations show that a VCP causes a delay in the current delivery to the load by upwards of 8 ns at 60 ns into atypical current pulse for an 1 × 10 7 A scale pulsed-power accelerator. The 2D simulations show the delay observed in the 1D simulations is reduced substantially (4 ns) by 2D turbulence that disrupts the VCP layer early in time. Here, the 2Dsimulated ETI growth varies across AR models, more so for the beryllium liner than the aluminum liner because the beryllium liner shows an enhanced rate of penetration for the magnetic diffusion wave in comparison to the aluminum liner. The 2D simulations show the bulk dielectric thickness varies across AR models with the Davidson AR model beingthe largest and the Buneman AR model being the smallest, and in connection with the thickness the Rayleigh-Taylor bubble-spike distances varies correspondingly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Equipment List Comparing Balance of Plant Containing a Heat Pump against a Reference Electricity Generating Plant

Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SPARTA: A flux adjustment methodology to interpret complex experiments

For the accurate determination of reactivity from a detector count rate, correction of spatial effects is of prime importance. This spatial correction is often provided using simulation methodologies, but this may introduce a bias if the result of the experiment is also used as input data for the simulation. Here, this work presents a flux adjustment methodology able to infer experimental reactivity and correction of spatial effects without the need for a simulation. It can process the signal from a complex experiment such as a heat balance measurement in the TREAT reactor, where control rods are continuously adjusted to maintain a constant power. In the present work, this methodology successfully computed the reactivity and the local spatial variation of the flux of a generated signal. It also proved to be robust against noise and errors on kinetic parameters and provides a credible interpretation of a heat balance experiment in TREAT. Efficiency of flux adjustment methods for complex experiment enable a better experiment interpretation less reliant on nuclear data evaluation.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Infrared laser ablation of poly(vinylidene fluoride): The Loss of HF

The mechanism and kinetics of infrared laser ablation of poly(vinylidene fluoride) (PVDF) in vacuum have been investigated to understand how this can be used as a polymer processing technology. The laser heats the surface and initiates decomposition of macromolecules in the molten polymer layer which rapidly leads to production of an ablative flow of polymer decomposition products. There is only a short induction period of up to 2 s before ablation begins. After the initial period, the rate of mass loss increases linearly with the time of laser exposure. Spherical particles with an average diameter of about 100 nm are formed on the surface of the powder coating obtained by laser ablation. Here, the particle distribution ranges from 50 nm to 300 nm. The main gaseous product of ablation is HF from dehydrofluorination. A second important ablation process is the formation of gaseous carbenes generated during secondary reactions. Proposed ablation reactions due to laser-induced thermal dehydrofluorination occur in two stages. In the first stage, a double bond appears in PVDF due to direct loss of HF. Subsequent detachment of HF leads to the appearance of both triple bonds and cumulene bonds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Engineering of LUPIN: A Test-Bed Radio-Frequency Ion Source for Enhanced Neutral Beam Injection on DIII-D

The Large, Uniform Plasma for Ionizing Neutrals (LUPIN) is a radio-frequency (RF) inductively coupled plasma (ICP) chamber for demonstrating plasma performance of an RF ICP positive ion source upgrade for the DIII-D neutral beam injection (NBI) system. LUPIN will be used to investigate ion source physics, including neutral gas dynamics, plasma density uniformity, interactions with Faraday shields, and power coupling to novel RF antenna designs. LUPIN has an RF generator capable of delivering 20 kW of power at 2 MHz, which is coupled into a cylindrical quartz vessel measuring 20 cm in length and 10 cm in radius. This configuration matches the power density requirements for a full-scale ion source. Target hydrogen and deuterium plasma densities exceeding 10 18 m -3 would relate to extracted ion current densities of 2100 A/m 2 for 10s. Vacuum conductance and gas flow calculations predict a maximum achievable neutral gas flow rate of 1675 Pa ⋅ L/s at 5 Pa of He, which mimics the gas flow of the DIII-D NBI system. Designs have been developed for an internal Faraday shield to mitigate heat flux and ion sputtering on the dielectric vessel. Thermomechanical finite element simulations demonstrated the Faraday shield design to be capable of withstanding anticipated heat loads from worst-case operation scenarios. Finally, results of upcoming experimental investigations on LUPIN will guide the design of a full-scale prototype for DIII-D integration.

Faraday shield↗

Assessment of Sodium Thermal Stratification Models Utilizing the TSTF Benchmark

As a result of certain transient scenarios, a thermally stratified layer of liquid sodium can develop in the bulk coolant volumes of a sodium-cooled fast reactor (SFR). In addition to the effects a stratification layer has on the temperature of the heat transport system, a stratification layer can also influence the transition to and establishment of natural circulation flow, which plays an important role in passive cooling and the inherent safety of a pool-type SFR. Therefore, the ability to accurately capture thermal stratification phenomena is important when demonstrating the safety basis of a pool-type SFR during transient sequences. The present work assesses various computational models with different fidelities in their ability to predict thermal stratification in the upper plenum of an SFR. Each computational model will be assessed using the data generated at the Thermal Stratification Test Facility (TSTF) located at the University of Wisconsin-Madison. Using measured flow rate and inlet temperature data, the measured temperature distributions of the tests are compared to the predictions of the lumped volume-based models in SAS4A/SASSYS-1, a 1D-based model in SAM, and a 3-D computational fluid dynamics (CFD) model using STAR-CCM+. The relative performance of the various computational methods is assessed with respect to key metrics such as bulk coolant temperature distribution and plenum exit temperature. A total of eight tests are analyzed, covering different combinations of flow rates (3 and 10 GPM) and upper internal structure (UIS) configurations (none, solid, porous, and open) The perfect mixing model of SAS4A/SASSYS-1 provides the highest accuracy when the flow rate is high and there is no UIS in the test vessel, as high flow rate injection promotes thermal mixing of the sodium in the test vessel. For most of the analyzed tests, the stratified volume model of SAS4A/SASSYS-1 is able to predict the delay in the outlet temperature drop and temperature distribution in the test vessel by a small number of layers to represent thermal stratification. However, the stratified volume model can only simulate a maximum of three temperature layers within a volume and when a layer approaches the elevation of the outlet, the predicted outlet temperature can demonstrate rapid, non-physical changes. The 1-D axial mixing model of SAM provides results that agree reasonably well with the measured data in the prediction of the temporal evolution of the outlet temperature with the exception of the case with a high flow rate and no UIS. The SAM 1-D model has a similar level of accuracy to CFD results when it comes to predicting the outlet temperature. CFD shows overall good agreement in predicting the temperature distribution in the test vessel and outlet temperature. As CFD can model the test vessel geometry in detail, it performs well in the cases of complex geometries such as tests that included a UIS and internal flow through the UIS resulting in active mixing of the coolant in the test vessel. Each of the models discussed in the present work has the potential to be useful during the various stages of reactor design, analysis, and licensing. The lumped-volume approach can be applied for fast turnaround safety calculations to obtain overall reactor behavior during transients. The 1-D models provide improved accuracy when stratification is expected for a relatively low increase in the computational cost. The CFD model can be utilized for confirmatory analysis of the 1-D model, when experimental measurements are not available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a HTGR

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts over the past decades have expanded its application scope to include non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR technologies under Strategy 2 of the NRC's near-term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR ha s undergone a range of enhancements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform high-temperature gas reactor (HTGR) safety evaluations. The generic plant model is based on publicly available PMBR-400 design information. For plant aspects (e.g., reactor building size and leak rate) that are not described in the PBMR-400 references, the analysts made assumptions needed to construct a MELCOR full-plant model. The HTGR model uses a TRi-structural ISOtropic (TRISO)-particle fuel pebble-bed reactor with a primary system rejecting heat to a recuperative heat exchange r. Surrounding the reactor vessel is a reactor cavity contained within a confinement room cooled by the Reactor Cavity Cooling System (RCCS). Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing reactivity control, primary system heat removal and reactor vessel decay heat removal, and confinement cooling.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultrafast Surface Phosphor Thermometry for Pulsed-power and Hostile Environments

Modern concepts for next generation pulsed power (NGPP) are slated to deliver up to ten times the energy of Z today. An increase of this magnitude is concerning insofar that Z currently exhibits sizable amounts of inner magnetically insulated transmission line (MITL) loss current on the order of 5-10%. Loss phenomenon in these systems are complex and electrode heating and subsequent thermal desorption are a leading cause. Rapid heat-driven thermal desorption of contaminants scales as the square of the current. Therefore, even a modest doubling of drive current would yield an ~ 4X in non-linear surface electrode heating, quickening thermal desorption-based current loss. Exacerbating these physics is a current inability to measure ultra fast heating rates (>20°C/ns), which are paramount to benchmarking and code validation critical to NGPP design – as an empirical approach is not viable. Therefore, Ultrafast Photoluminescent Surface Heating Optical Thermometry (UP-SHOT) was developed as a new diagnostic for measurement of GHz-scale electrode heating. The discovery of UP-SHOT leveraged expertise in Engineering Science, Material Science, Pulsed-Power, and the Center for Integrated Nanotechnologies. This report includes information on: 1) The preparation of zinc oxide (ZnO) films, characterization, post-deposition treatments 2) Time-resolved photoluminescence at elevated temperatures and thermographic sensitivity

36 MATERIALS SCIENCE↗

Advanced biorefinery feedstock from non-recyclable municipal solid waste by mechanical preprocessing

Because of accelerated urbanization and the development of a global economy, a large quantity of municipal solid waste (MSW) has been collected and disposed of by the municipalities. Due to this drastic increase in the disposal of MSW, the need for its management is a must to preserve the environment. Currently, approximately 50% of the total MSW generated in the United States has been utilized through various recycling, combustion, and composting technologies, which means the remaining 50% is sent to landfill; this is often known as non-recyclable MSW (nMSW). As this nMSW is physically and chemically heterogenous and contains very high amounts of inorganic material, processing is required prior to using it as a biorefinery feedstock. Thus, this study focused on how mechanical preprocessing advanced the physical and chemical properties of nMSW. The physical and chemical properties were investigated in terms of particle size distribution, bulk density, ultimate and proximate analysis, and the higher heating value (HHV). The combustion properties were examined in terms of ignition temperature, peak heat release rate, and combustion efficiency. Results showed that the variability of physical and chemical properties of nMSW can be reduced by mechanical preprocessing. For example, the variability of the bulk density of the as-received nMSW was approximately 17.3% while it reduced to 5.8% when the sample size was reduced to 2 mm. Similarly, the variability of ash and HHV reduced from 49.2% to 11.0% and 13.4%–4.2%, respectively. Combustion thermograms showed that the size reduction positively improved the combustion properties. For example, 2 mm of spec sample started to ignite approximately 4 times earlier and took 6.5 folds less time to reach the peak heating rate compared to as-received nMSW. Overall, the mechanical preprocessing reduced the variability of physical and chemical properties in addition to the improvement of combustion behavior of the nMSW which is one step forward toward the biorefinery feedstock.

09 BIOMASS FUELS↗

Design and Engineering of LUPIN: A Test-Bed Radiofrequency Ion Source for Enhanced Neutral Beam Injection on DIII-D

The Large, Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma (ICP) chamber for demonstrating plasma performance of an RF ICP positive ion source upgrade for the DIII-D Neutral Beam Injection (NBI) system. LUPIN will be used to investigate ion source physics, including neutral gas dynamics, plasma density uniformity, interactions with Faraday shields, and power coupling to novel RF antenna designs. LUPIN has an RF generator capable of delivering 20 kW of power at 2 MHz, which is coupled into a cylindrical quartz vessel measuring 20 cm in length and 10 cm in radius. This configuration matches the power density requirements for a full-scale ion source. Target hydrogen and deuterium plasma densities exceeding 10 18 m -3 would relate to extracted ion current densities of 2100 A/m 2 for 10 s. Vacuum conductance and gas flow calculations predict a maximum achievable neutral gas flow rate of 1675 Pa·L/s at 5 Pa of He, which mimics the gas flow of the DIII-D NBI system. Designs have been developed for an internal Faraday shield to mitigate heat flux and ion sputtering on the dielectric vessel. Thermomechanical finite element simulations demonstrated the Faraday shield design to be capable of withstanding anticipated heat loads from worst-case operation scenarios. Results of upcoming experimental investigations on LUPIN will guide the design of a full-scale prototype for DIII-D integration.

Faraday shield↗

Sparge Sampling of Molten Salts for Online Monitoring via Laser-Induced Breakdown Spectroscopy

A method was developed to sample molten salts by sparging to generate and transport aerosols to an isolated instrument for compositional analysis by laser-induced breakdown spectroscopy (LIBS). Real-time monitoring of molten salt composition is critical to developing molten salt nuclear reactors, which offer enhanced safety and efficiency. In this article, the sparge sampling method is described and compared with sampling using a Collison nebulizer. The size distribution and transport of aerosols produced from molten eutectic NaNO 3 –KNO 3 salt were compared for multiple gas flow rates (75–1200 mL min –1 ) and transport distances (0.68–2.61 m). Both methods produced aerosols ranging from 0.5 to 5.0 μm determined using a cascade impactor. Aerosols were effectively transported without pre- or trace-heating of gas lines, but transport efficiency was reduced by the formation of agglomerates. Sparge sampling was found to use less sample and less gas than a Collison nebulizer while producing a more concentrated aerosol stream (up to 5 μg L –1 ). The effects of laser energy and delay time on the signal quality of LIBS measurements of these aerosols were also studied. High energy and short delay times were found to enhance signal and repeatability, whereas signal-to-background and signal-to-noise ratios were highest at low energy and longer delay times. The capabilities of this system for online monitoring of molten salts were demonstrated with calibrations for Sr and Li with relative standard deviations of 2.6% and 1.5% and limits of detection of 380 and 180 μg g –1 , respectively.

Aerosols↗