Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Packages in KAC (2021 Status Report)

Thermal, mechanical, and physical properties have been measured on fiberboard samples following accelerated aging for up to 16 years. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 and non3013 containers in storage from 15 years to 20 years. These calculations addressed the potential for degraded fiberboard properties following 20 years in storage using degradation models developed previously. The updated degradation models developed in this report have been compared to the assumptions in these calculations, and the current results for fiberboard dimensions, density, radial thermal conductivity, and energy absorption remain consistent with those calculations. The axial thermal conductivity degradation rate slightly exceeds calculations estimate of 0.5% per year between 130 and 160 °F. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are extreme. However, these relate to environments that do not exist within KAC or would be postulated only as upset conditions that would not likely persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 ºF, the fiberboard assemblies experience storage conditions less severe than any of the aging environments. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 20 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 20 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of nonconforming conditions such as the presence of excess moisture and mold or beetle infestations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing high performance RF heating scenarios on the WEST tokamak

High power experiments, up to 9.2 MW with LHCD and ICRH, have been carried out in the full tungsten tokamak WEST. Quasi non inductive discharges have been achieved allowing to extend the plasma duration to 53s with stationary conditions in particular with respect to tungsten contamination. Transitions in H mode are obtained lasting up to 4s with weak energy increment at the power crossing the separatrix is close to the threshold. Hot L mode plasmas (Te(0)>3keV) with a confinement time following the ITER L96 scaling are routinely obtained. The weak aspect ratio dependence of this scaling law is confirmed. Tungsten accumulation is generally not an operational issue on WEST. Difficulty of burning through tungsten can prevent from accessing to a hot core plasma in the ramp-up phase or can lead to rapid collapse of the central temperature when radiation is enhanced by a slight decrease of the temperature. Apart few pulses post-boronization, the plasma radiation is rather high (Prad/Ptot~50%) and is dominated by tungsten. This fraction does not vary as the RF power is ramped up and is quite similar in ICRH and/or LHCD heated plasmas. An estimate of the contribution of the RF antennas to the plasma contamination in tungsten is given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC (2022 Status Report)

Thermal, mechanical, and physical properties have been measured on fiberboard samples following accelerated aging for up to 17 years. The aging environments include elevated temperature up to 250 °F (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 containers in storage from 20 years to 40 years. These calculations addressed the potential for degraded fiberboard properties following 40 years in storage using degradation models developed previously. Due to differences in containers, 9975 packages with non-3013 containers are only approved for 20 years of storage. The updated degradation models developed in this report have been compared to the assumptions in those calculations, and the current results for fiberboard dimensions, density, radial thermal conductivity, and energy absorption remain consistent with those calculations. The axial thermal conductivity degradation rate slightly exceeds calculations estimate of 0.5% per year between 130 and 160 °F. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are extreme. However, these relate to environments that do not exist within KAC or would be postulated only as upset conditions that would not likely persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 °F, the fiberboard assemblies experience storage conditions less severe than any of the aging environments. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 40 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 40 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of non-conforming conditions such as the presence of excess moisture and mold or beetle infestations.

36 MATERIALS SCIENCE↗

Divertor detachment and heat exhaust mitigation control in KSTAR with tungsten divertor

KSTAR has recently undergone an upgrade to use a new tungsten divertor to run experiments in ITER-relevant scenarios. Even with a high melting point of tungsten, it is important to control the heat flux impinging on tungsten divertor targets to minimize sputtering and contamination of the core plasma. Heat flux on the divertor is often controlled by increasing the degree of detachment of scrape-off layer plasma from the target plates. In this work, we have demonstrated successful divertor detachment and heat exhaust dissipation control experiments using two different methods. The first method uses attachment fraction as a control variable which is estimated using ion saturation current measurements from embedded Langmuir probes in the divertor. The second method uses a novel machine-learning-based surrogate model of 2D UEDGE simulation database, DivControlNN. We demonstrated running inference operation of DivControlNN in realtime to estimate heat flux at the divertor and use it as the control variable in a feedback loop with impurity gas flow. We present interesting insights from these experiments including a systematic approach to tuning controllers and discuss future improvements in the control infrastructure and control variables for future burning plasma experiments.

KSTAR tungsten divertor operations↗

Optimizing HAARP Beam Pattern for Generation of Strong F‐Region Field‐Aligned Irregularities

Field-aligned irregularities (FAIs) are the signatures of plasma turbulence and convection in the mid- and high-latitude F-region ionosphere, and also provide coherent backscatter targets for HF radars. To serve irregularity generation and characterization studies, we conducted experiments at the High-frequency Active Auroral Research Program (HAARP) in August 2023 with the goal of identifying the optimal HAARP beam pattern for reliable generation of intense FAIs over a large geographic region. The HAARP beam patterns we tested were the commonly-used narrow beam, also known as L0, as well as the wider L1 and L2 “twisted” beam patterns. The size and intensity of the FAI region generated by each HAARP beam pattern was quantified using the Kodiak Island Super Dual Auroral Radar Network (SuperDARN) radar. Stimulated electromagnetic emissions (SEE) from heater wave-FAI scattering were also recorded using a receiver located near HAARP. The L1 beam pattern was found to produce the strongest SuperDARN backscatter over the largest region. Although the heater frequency was intended to be tuned a few hundred kHz below the F-region critical frequency (foF2) during each experiment, difficulty in estimating foF2 during the campaign likely resulted in HAARP heating at significantly different frequency ranges around foF2 during each experiment. Although this additional free parameter complicated data analysis for this study, the SuperDARN and SEE measurements have led to further inquiry into the role heater frequency plays in the artificial generation of FAIs.

58 GEOSCIENCES↗

Developing high performance RF heating scenarios on the WEST tokamak

High power experiments, up to 9.2 MW with LHCD and ICRH, have been carried out in the full tungsten tokamak WEST. Here, quasi non inductive discharges have been achieved allowing to extend the plasma duration to 53 s with stationary conditions in particular with respect to tungsten contamination. Transitions to H mode are observed, and H-modes lasting up to 4 s have been obtained. The increase in stored energy is weak since the power crossing the separatrix is close to the L–H threshold. Hot L mode plasmas (central temperature exceeding 3 keV) with a confinement time following the ITER L96 scaling law are routinely obtained. The weak aspect ratio dependence of this scaling law is confirmed. Tungsten accumulation is generally not an operational issue on WEST. Difficulty of burning through tungsten can prevent the discharge from accessing to a hot core plasma in the ramp-up phase, or can lead to rapid collapse of the central temperature when radiation is enhanced by a slight decrease of the temperature. Except a few pulses post-boronization, the plasma radiation is rather high (P rad /P tot ~ 50%) and is dominated by tungsten. This fraction does not vary as the RF power is ramped up and is quite similar in ICRH and/or LHCD heated plasmas. An estimate of the contribution of the RF antennas to the plasma contamination in tungsten is given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of the thermal conductivity of molten LiF-NaF-KF with experiments, theory, and equilibrium molecular dynamics

Molten salts are being proposed for numerous advanced energy applications, including advanced nuclear reactors, concentrating solar power plants, thermal energy storage, and fusion reactors. Accurate knowledge of the thermophysical properties of molten salts directly impact the performance of these energy systems and are essential for design and safety analyses. Thermal conductivity data for fluoride molten salts and mixtures are especially lacking. In this work, experimental measurements of thermal conductivity using the steady-state variable gap technique were performed on eutectic LiF-NaF-KF from 834 to 1195 K. The experiment accounts for radiative, convective, and conductive heat losses. In addition, theoretical and molecular dynamics models are used, from 750 K up to 1300 K, to estimate the thermal conductivity for comparison with the experimental results. The results of experiments show a weak negative deviation of thermal conductivity with temperature, unlike previous experimental results in the literature. The measured thermal conductivity magnitudes agree with the theoretical and molecular dynamics predictions, aside from the data above 1100 K, where heat losses and radiative errors are the most significant, having a 16% maximum deviation from theory. These experimental results provide new thermal conductivity data for the LiF-NaF-KF system and further validation of the predictive models. The theoretical model was used to map the composition and temperature dependent thermal conductivity of LiF-NaF-KF and the mapping’s deviation from a linear additivity estimation of thermal conductivity. Additionally, this mapping showed the highest deviations from linearity for KF-LiF rich mixtures and increasing deviation with temperature. Notably, the deviation from linearity near the LiF-NaF-KF eutectic composition was around 25%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel geometries for air-cooled condensation of ammonia-water mixtures

An analytical and experimental investigation of air-cooled condensers for small-scale ammonia-water absorption heat pumps is presented. Conventional round-tube corrugated fin design and a novel multi-pass tube array design are considered for a condenser operating at severe ambient conditions within a compact footprint. Segmental heat and mass transfer models are developed to gain a deeper understanding of the characteristics of each design. Predicted heat duties are within 5% of the measured values. The limitations of correlations to predict air-side pressure drop in corrugated fins are identified. The performance of the novel multi-pass tube array condenser was comparable to that of conventional condensers, but is determined to be air-side limited throughout length of the heat exchanger. An improved multi-pass condenser design with fins for increased air-side area is proposed using the insights gained from the modeling and experiments. In closing this design meets the heat duty requirements at severe ambient conditions, while decreasing the size of the heat exchanger by 33%.

42 ENGINEERING↗

2025 Status Report - Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC

Fiberboard assemblies in the 9975 package were identified as susceptible to aging and degradation under long-term storage conditions. Thermal, mechanical, and physical properties have been measured on fiberboard samples aging for up to 20 years at accelerated conditions. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 containers in storage from 20 years to 40 years. These calculations addressed the potential for degraded fiberboard properties following 40 years in storage using degradation models. The 40 year storage evaluations assumed the degradation rates from initial values for density, dimensional, and thermal properties were 0.5% per year (i.e., after 40 years, the density, dimensional, and thermal properties of fiberboard were 80% of its initial values). The updated degradation models developed in this report were compared to the assumptions in those calculations, and the current results for fiberboard dimensions, density, axial and radial thermal conductivities, and energy absorption remain consistent with those calculations. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are purposely high to accelerate aging. These rates relate to environments that do not exist within KAC or are postulated to only occur as upset conditions that are unlikely to persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 ºF, the fiberboard assemblies experience storage conditions less severe than any of the aging environments (i.e., under 125 °F) used in this study. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 40 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 40 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of nonconforming conditions such as the presence of excess moisture and mold or beetle infestations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Observation of persistent species temperature separation in inertial confinement fusion mixtures

The injection and mixing of contaminant mass into the fuel in inertial confinement fusion (ICF) implosions is a primary factor preventing ignition. ICF experiments have recently achieved an alpha-heating regime, in which fusion self-heating is the dominant source of yield, by reducing the susceptibility of implosions to instabilities that inject this mass. We report the results of unique separated reactants implosion experiments studying pre-mixed contaminant as well as detailed high-resolution three-dimensional simulations that are in good agreement with experiments. At conditions relevant to mixing regions in high-yield implosions, we observe persistent chunks of contaminant that do not achieve thermal equilibrium with the fuel throughout the burn phase. The assumption of thermal equilibrium is made in nearly all computational ICF modeling and methods used to infer levels of contaminant from experiments. We estimate that these methods may underestimate the amount of contaminant by a factor of two or more.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerated Creep Test Qualification of Creep-Resistance Using the Wilshire–Cano–Stewart Constitutive Model and Stepped Isostress Method

In this paper, a qualification of accelerated creep-resistance of Inconel 718 is assessed using the novel Wilshire–Cano–Stewart (WCS) model and the stepped isostress method (SSM) and predictions are made to conventional creep data. Conventional creep testing is a long-term continuous process; in fact, the ASME B&PV III requires that 10,000+ h of experiments must be conducted to each heat for materials employed in boilers and/or pressure vessel components. This process is costly and not feasible for rapid development of new materials. As an alternative, accelerated creep testing techniques have been developed to reduce the time needed to characterize the creep resistance of materials. Most techniques are based upon the time-temperature-stress superposition principle that predicts minimum-creep-strain-rate (MCSR) and stress-rupture behaviors but lack the ability to predict creep deformation and consider deformation mechanisms that occur for experiments of longer duration. The SSM has been developed, which enables the prediction of creep deformation response as well as reduce the time needed for qualification of materials. The SSM approach has been successful for polymer, polymeric composites, and recently has been introduced for metals. In this study, the WCS constitutive model, calibrated to SSM test data, qualifies the creep resistance of Inconel 718 at 750 °C and predictions are compared to conventional creep testing data. The WCS model has proven to make long-term predictions for stress-rupture, MCSR, creep deformation, and damage in metallic materials. The SSM varies stress levels after time interval adding damage to the material, which can be tracked by the WCS model. The SSM data is calibrated into the model and the WCS model generates realistic predictions of stress-rupture, MSCR, damage, and creep deformation. The calibrated material constants are used to generate predictions of stress-rupture and are postaudit validated using the National Institute of Material Science database. Similarly, the MCSR predictions are compared from previous studies. Finally, the creep deformation predictions are compared with real data and is determined that the results are well in between the expected boundaries. Material characterization and mechanical properties can be determined at a faster rate and with a more cost-effective method. This is beneficial for multiple applications such as in additive manufacturing, composites, spacecraft, and industrial gas turbines.

42 ENGINEERING↗

Local convection characteristics of inline arrangement of Kagome-shaped unit cells in a square duct

Transient liquid crystal thermography experiments have been conducted to determine detailed convective heat transfer coefficients at the endwalls of lattice-frame configurations based on Kagome-shaped unit cells. Kagome unit cells with porosity of 0.88 were arranged in an inline manner, where two such arrangements were studied. In the first arrangement, a total of ten unit cells were placed next to each other along the streamwise direction resulting in a continuous configuration. In the 2nd arrangement, alternate unit cells from the continuous configuration were dropped, resulting in a discrete configuration which featured a total of 5 Kagome unit cells. Due to the asymmetric nature of the strut connections within the unit cell, the convective heat transfer coefficient maps were determined for the two opposite walls where the struts meet the endwalls. Transient liquid crystal experiments were conducted for Reynolds number ranging between 10,000 and 30,000. Here, the study was focused on the developing nature of flow along the streamwise direction and the local convection characteristics for continuous and discrete arrangement of unit cells. For the continuous configuration, the Nusselt number ratios (N u /Nu 0 ) varied between 3.15–3.46 and 2.75–2.89 for the two walls A and B, respectively. For the discrete configuration, convective heat transfer coefficients varied between 2.56–2.71 and 2.09–2.40 for the two walls. Kagome unit cells have the potential to be fabricated through inexpensive manufacturing routes such as wire-woven method and these unit cells find their applications in the areas which require different heat transfer levels on opposite walls.

Kagome↗

ACCELERATED CREEP TEST (ACT) QUALIFICATION OF CREEP RESISTANCE USING THE WCS CONSTITUTIVE MODEL AND STEPPED ISOSTRESS METHOD (SSM)

In this study, a qualification of accelerated creep-resistance of Inconel 718 is assessed using the novel Wilshire-Cano-Stewart (WCS) model and the stepped isostress method (SSM) and predictions are made to conventional creep data. Conventional creep testing (CCT) is a long-term continuous process, in fact, the ASME B&PV III requires that 10,000+ hours of experiments must be conducted to each heat for materials employed in boilers and/or pressure vessel components. This process is costly and not feasible for rapid development of new materials. As an alternative, accelerated creep testing techniques have been developed to reduce the time needed to characterize the creep resistance of materials. Most techniques are based upon the time-temperature-stress superposition principle (TTSSP) that predicts minimum-creep-strain-rate (MCSR) and stress-rupture behaviors but lack the ability to predict creep deformation and consider deformation mechanisms that occur for experiments of longer duration. The stepped isostress method (SSM) has been developed which enables the prediction of creep deformation response as well as reduce the time needed for qualification of materials. The SSM approach has been successful for polymer, polymeric composites, and recently has been introduced for metals. In this study, the WCS constitutive model, calibrated to SSM test data, qualifies the creep resistance of Inconel 718 at 750°C and predictions are compared to CCT data. The WCS model has proven to make long-term predictions for stress-rupture, minimum-creep-strain-rate (MCSR), creep deformation, and damage in metallic materials. The SSM varies stress levels after time interval adding damage to the material, which can be tracked by the WCS model. The SSM data is calibrated into the model and the WCS model generates realistic predictions of stress-rupture, MSCR, damage, and creep deformation. The calibrated material constants are used to generate predictions of stress-rupture and are post-audit validated using the National Institute of Material Science (NIMS) database. Similarly, the MCSR predictions are compared from previous studies. Finally the creep deformation predictions are compared with real data and is determined that the results are well in between the expected boundaries. Material characterization and mechanical properties can be determined at a faster rate and with a more cost-effective method. This is beneficial for multiple applications such as in additive manufacturing, composites, spacecraft, and Industrial Gas Turbines (IGT).

36 MATERIALS SCIENCE↗

Validation of implosion modeling through direct-drive shock timing experiments at the National Ignition Facility

Precise modeling of shocks in inertial confinement fusion implosions is critical for obtaining the desired compression in experiments. Shock velocities and post-shock conditions are determined by laser-energy deposition, heat conduction, and equations of state. This paper describes experiments at the National Ignition Facility (NIF) where multiple shocks are launched into a cone-in-shell target made of polystyrene, using laser pulse shapes with two or three pickets and varying on-target intensities. Shocks are diagnosed using the Velocity Interferometric System for Any Reflector diagnostic. Simulated and inferred shock velocities agree well for the range of intensities studied in this work. These results are the first shock-velocity measurements using direct drive on the NIF and provide a good measure of early-time, directly driven laser-energy coupling. Furthermore, the validated models add to the credibility of direct-drive-ignition designs at the megajoule scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generating Buoyancy-Driven Convection in Membrane Distillation

Membrane distillation (MD) is a thermally-driven desalination process that can treat hypersaline brines. Considerable MD literature has focused on mitigating temperature and concentration polarization. This literature largely neglects that temperature and concentration polarization increase the feed density near the membrane. With gravity properly oriented, this increase in density could trigger buoyancy-driven convection and increase permeate production. Convection could also be strengthened by heating the feed channel wall opposite the membrane. To investigate that possibility, we perform a series of experiments using a plate-and-frame direct contact MD system with an active membrane area of 300 cm2 and a feed channel wall heated using a resistive heater. The experiments measure the average transmembrane permeate flux for two gravitational orientations, feed Reynolds numbers between 128 and 1128, and wall heat fluxes up to 12 kW/m2. The results confirm that with gravity properly oriented, wall-heating can trigger buoyancy-driven convection for a wide range of feed Reynolds numbers, and increase permeate production between roughly 20 and 130 %. We estimate, however, that at high Reynolds numbers (Re > 800), more than 70 % of the wall heat is carried out of the MD system by the feed flow, without contributing to permeate production. This suggests the need for longer membranes and heat recovery steps in any future practical implementation.

buoyancy-driven convection↗

Discrimination of Hexane Isomers by Temperature Swing Adsorption in a Rigid Aluminum Metal–Organic Framework

The efficient separation of alkane isomers with similar physicochemical properties remains a persistent challenge for the petrochemical industry. Adsorptive separation using metal− organic frameworks (MOFs) offers an energy-efficient alternative to conventional distillation. Herein, we report temperature swing discrimination of hexane isomers with different degrees of branching using MIL-120, a rigid aluminum pyromellitate-based MOF. MIL-120 features uniform one-dimensional channels with an aperture of ∼5.5 Å. At 30 °C, it selectively adsorbs linear and monobranched hexanes while excluding the dibranched isomer. Upon heating to 120 °C, both mono- and dibranched isomers are completely excluded, whereas linear hexane remains strongly adsorbed. Breakthrough experiments validate the temperature swing separation performance. Adsorption heat analysis combined with ab initio calculations provides a quantitative measure of distinct differences in adsorption enthalpies, binding energies, and diffusion barriers responsible for the observed separation efficiency, highlighting the potential of this MOF for efficient separation of alkane isomers via temperature swing adsorption.

Adsorption↗

Experimental investigation on nucleate boiling heat transfer of low GWP refrigerants over metal-foam enhanced tube bundles

The objective of this work is to develop an enhanced tube bundle to improve the nucleate boiling heat transfer for the application of flooded evaporators. The enhanced tube bundle was made by deploying metal foam around the outer surface of aluminum tubes, which provide higher heat transfer area and nucleation site density. The pool boiling experiments for horizontal tube bundles were conducted in a pressure vessel at difference heat fluxes. The heat transfer performance of bare aluminum tube bundle was compared against the metal-foam enhanced tube bundle using low GWP refrigerant, R-1234yf. The experimental results showed that the heat transfer coefficient of the metal-foam enhanced tube bundle was at least two times higher than that of the bare tube bundle, and the enhancement ratio depended on the heat flux condition.

Yang, Cheng-Min↗

THOR-aLEU Report

The advanced low enriched uranium (aLEU)-THOR experiment vehicle is designed to irradiate fresh fuel rodlet specimens containing UO 2 (uranium dioxide) in the Temperature Heat-sink Overpower Response (THOR) capsule. The goal of the experiments are to compare the behaviors of standard UO 2 pellets to an aLEU concept in which molybdenum (Mo) foils separate UO 2 wafers increasing the thermal conductivity of the fuel. This experiment is designed to be conducted in the Transient Reactor Test facility (TREAT) using the Minimal Activation Retrievable Capsule Holder (MARCH) irradiation system. The goal of these experiments is to assess the effect of thermally conductive inserts in UO 2 by measuring their net effect on radial thermal conductivity using transient nuclear heating and then to determine their power-to-melt threshold in transient overpower ramps. The objective of the aLEU-THOR fuels experiment is to determine the viability and study the performance of UO 2 fuel pellets employing newly upgraded TREAT capability. A novel transient measurement technique will be used with the THOR capsule, which has a solid heat sink to generate the transient temperature gradient for conductivity measurement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗