Search NASA⌕ Search

SEARCH · Search NASA

Results for “High contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Phase Retrieval Implementation for the WFIRST Coronagraph Development Testbed

The Wide-Field Infrared Survey Telescope (WFIRST) is a 2.4m diameter space telescope NASA program. The payload will include two instruments, including a coronagraph instrument (CGI). The CGI will be the first active, high-contrast stellar coronagraph in space intended for imaging, discovery, and spectral characterization of exoplanets and debris discs. The CGI designs under development use deformable mirrors (DM) to create a point spread function (PSF) with a dark region around the obscured star object. Each DM consists of an array of actuators, and each actuator causes a local displacement to a thin, mirror-coated, glass face sheet. The actuator displacements are designed to create the PSF. Typically, phase retrieval is used to set the DM actuator displacements to their designed pattern, and then the actuators are further modified by an iterative control loop to correct for system non-idealities. To observe an exoplanet near the star object, the contrast in the annular region must be better than 10^8 (10^9 after post processing) relative to the unobstructed image of the star [1,2]. The coronagraph testbed at Jet Propulsion Laboratory is used to test coronagraph design and control algorithms. The optical system (Fig. 1) is maintained in a vacuum tank so that the PSF is stable for long integration times. Phase retrieval is an important tool for the testbed and serves several purposes, in addition to setting initial DM actuator displacements. Other uses include evaluation of systematic wavefront error introduced by system components, and alignment of the DMs and pupil masks. For example, the location of specific DM actuators relative to the Lyot mask can be determined by displacing the actuator, then measuring the location of the phase disturbance in the pupil plane with phase retrieval. In the next section we further describe the optical train of the testbed and the collection of source and pupil images available as inputs for phase retrieval, as well as one phase retrieval algorithm employed. Section 3 shows example phase retrieval results.

Marx, David↗

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based X-ray microscope

With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

3D virtual histology↗

Image wavelet decomposition and applications

The general problem of computer vision has been investigated for more that 20 years and is still one of the most challenging fields in artificial intelligence. Indeed, taking a look at the human visual system can give us an idea of the complexity of any solution to the problem of visual recognition. This general task can be decomposed into a whole hierarchy of problems ranging from pixel processing to high level segmentation and complex objects recognition. Contrasting an image at different representations provides useful information such as edges. An example of low level signal and image processing using the theory of wavelets is introduced which provides the basis for multiresolution representation. Like the human brain, we use a multiorientation process which detects features independently in different orientation sectors. So, images of the same orientation but of different resolutions are contrasted to gather information about an image. An interesting image representation using energy zero crossings is developed. This representation is shown to be experimentally complete and leads to some higher level applications such as edge and corner finding, which in turn provides two basic steps to image segmentation. The possibilities of feedback between different levels of processing are also discussed.

Treil, N.↗

Diffraction and Imaging Study of Imperfections of Protein Crystals with Coherent X-rays

High angular-resolution x-ray diffraction and phase contrast x-ray imaging were combined to study defects and perfection of protein crystals. Imperfections including line defects, inclusions and other microdefects were observed in the diffraction images of a uniformly grown lysozyme crystal. The observed line defects carry distinct dislocation features running approximately along the <110> growth front and have been found to originate mostly in a central growth area and occasionally in outer growth regions. Slow dehydration led to the broadening of a fairly symmetric 4 4 0 rocking curve by a factor of approximately 2.6, which was primarily attributed to the dehydration-induced microscopic effects that are clearly shown in diffraction images. X-ray imaging and diffraction characterization of the quality of apoferritin crystals will also be discussed in the presentation.

Hu, Z. W.↗

Detection of defects in atomic-resolution images of materials using cycle analysis

The automated detection of defects in high-angle annular dark-field Z-contrast (HAADF) scanning-transmission-electron microscopy (STEM) images has been a major challenge. Here, we report an approach for the automated detection and categorization of structural defects based on changes in the material’s local atomic geometry. The approach applies geometric graph theory to the already-found positions of atomic-column centers and is capable of detecting and categorizing any defect in thin diperiodic structures (i.e., “2D materials”) and a large subset of defects in thick diperiodic structures (i.e., 3D or bulk-like materials). Despite the somewhat limited applicability of the approach in detecting and categorizing defects in thicker bulk-like materials, it provides potentially informative insights into the presence of defects. The categorization of defects can be used to screen large quantities of data and to provide statistical data about the distribution of defects within a material. This methodology is applicable to atomic column locations extracted from any type of high-resolution image, but here we demonstrate it for HAADF STEM images.

36 MATERIALS SCIENCE↗

3D Deep Learning Joint Inversion of Active Seismic Full Waveform and Passive Seismic Traveltime Data for Reservoir Imaging and Uncertainty Quantification

Here, we present deep learning (DL) networks for three-dimensional (3D) joint inversion of active seismic full waveform and passive seismic traveltime data to image reservoirs and their properties and quantify imaging uncertainties. Active seismic full-waveform data can provide high-resolution monitoring images but are collected only intermittently because of their high acquisition cost. In contrast, passive seismic data can be gathered at relatively low cost between regular active surveys, although their imaging quality can be compromised by factors such as low signal-to-noise ratios and limited ray coverage of the target. Although these datasets are routinely acquired together at CO 2 storage sites, their combined inversion within a 3D DL framework has not been previously demonstrated. To our knowledge, this is the first study to address this gap, combining the strength of both data types. For efficient data storage and DL training with large 3D seismic datasets, we use a 3D data matrix in which a random number of passive seismic traveltime data are stored as parabolic envelopes using one-hot encoding and a 3D full-waveform data matrix in which multiple shot gathers are summed. Two network architectures are evaluated: a single-encoder U-Net for single-data type inversion and a dual-encoder U-Net for joint inversion of active and passive seismic data. We also evaluate the single-encoder U-Net for joint inversion by concatenating full-waveform data and traveltime data. We propose a systematic approach for selecting an optimal dropout rate that balances regularization during training and Monte Carlo dropout-based uncertainty quantification during prediction by examining the correlation coefficient between standard deviation and prediction error, along with the training misfit, across a range of dropout rates. 3D DL inversion experiments include five different network configurations, with evaluations under ideal, noisy and dropout-enabled conditions. Both model and data uncertainties are assessed, as well as their combined effects. Across all conditions, the networks consistently predict accurate CO 2 saturation models with low prediction errors, such as a structural similarity index of 0.993 and CO 2 difference of 1.1%. Uncertainty estimates show strong spatial correlation with prediction errors, confirming the effectiveness of the proposed dropout selection approach. The results demonstrate that our DL approach, utilizing compact data representations and appropriate uncertainty quantification, yields accurate subsurface images under various inversion conditions and provides valuable insights into the reliability of predictions.

Um, Evan Schankee [Lawrence Berkeley National Labo↗

X-ray Phase Contrast Imaging of the Impact of Multiple HMX Particles in a Polymeric Matrix

The initiation of high explosives (HEs) under shock loading lacks a comprehensive understanding: particularly at the particle scale. One common explanation is the hot spot theory, which suggests that energy in the material resulting from the impact event is localized in a small area causing an increase in temperature that can lead to ignition. This study focuses on the response of HMX particles (a common HE) within a polymer matrix (Sylgard-184 (R)), a simplified example of a polymer-bound explosive (PBX). These PBXs consist of multiple HMX particles in a single polymer-bound sample. A light gas gun was used to load the samples at impact velocities above 400 m/s. The impact events were visualized using X-ray phase-contrast imaging (PCI) allowing real-time observation of the impact event. The experiment used two different types of samples (multi-particle and two crystals) and found evidence of cracking and debonding in both sample types. Additionally, it was found that the multiple particle samples showed similar evidence of damage at lower velocities than that of single particle samples. This is an expected result as the multiple particles add additional interfaces for stress concentration and frictional heating.

42 ENGINEERING↗

Ultra-Wideband Microwave Imaging System for Root Phenotyping

The roots are a vital organ for plant growth and health. The opaque surrounding environment of the roots and the complicated growth process means that in situ and non-destructive root phenotyping face great challenges, which thus spur great research interests. The existing methods for root phenotyping are either unable to provide high-precision and high accuracy in situ detection, or they change the surrounding root environment and are destructive to root growth and health. Thus,we propose and develop an ultra-wideband microwave scanning method that uses time reversal to achieve in situ root phenotyping nondestructively. To verify the method’s feasibility, we studied an electromagnetic numerical model that simulates the transmission signal of two ultra-wideband microwave antennas. The simulated signal of roots with different shapes shows the proposed system’s capability to measure the root size in the soil. Experimental validations were conducted considering three sets of measurements with different sizes, numbers and locations, and the experimental results indicate that the developed imaging system was able to differentiate root sizes and numbers with high contrast. The reconstruction from both simulations and experimental measurements provided accurate size estimation of the carrots in the soil, which indicates the system’s potential for root imaging.

59 BASIC BIOLOGICAL SCIENCES↗

Design of proton deflectometry with in situ x-ray fiducial for magnetized high-energy-density systems

We report a design and implementation of proton deflectometry with an in situ reference x-ray image of a mesh to precisely measure non-uniform magnetic fields in expanding plasmas at the OMEGA and OMEGA EP laser facilities. The technique has been developed with proton and x-ray sources generated from both directly driven capsule implosions and short pulse laser–solid interactions. The accuracy of the measurement depends on the contrast of both the proton and x-ray images. Here we present numerical and analytic studies to optimize the image contrast using a variety of mesh materials and grid spacings. Our results show clear enhancement of the image contrast by factors of four to six using a high Z mesh with large grid spacing. This leads to further improvement in the accuracy of the magnetic field measurement using this technique in comparison with its first demonstration at the OMEGA laser facility [Rev. Sci. Instrum. 93, 023502 (2022) [CrossRef]].

47 OTHER INSTRUMENTATION↗

Novel self-assembled two-dimensional layered oxide structure incorporated with Au nanoinclusions towards multifunctionalities

Two-dimensional (2D) layered oxides have recently attracted wide attention owing to the strong coupling among charges, spins, lattice, and strain, which allows great flexibility and opportunities in structure designs as well as multifunctionality exploration. In parallel, plasmonic hybrid nanostructures exhibit exotic localized surface plasmon resonance (LSPR) providing a broad range of applications in nanophotonic devices and sensors. A hybrid material platform combining the unique multifunctional 2D layered oxides and plasmonic nanostructures brings optical tuning into the new level. Here, a novel self-assembled Bi 2 MoO 6 (BMO) 2D layered oxide incorporated with plasmonic Au nanoinclusions has been demonstrated via one-step pulsed laser deposition (PLD) technique. Comprehensive microstructural characterizations, including scanning transmission electron microscopy (STEM), differential phase contrast imaging (DPC), and STEM tomography, have demonstrated the high epitaxial quality and particle-in-matrix morphology of the BMO-Au nanocomposite film. DPC-STEM imaging clarifies the magnetic domain structures of BMO matrix. Three different BMO structures including layered supercell (LSC) and superlattices have been revealed which is attributed to the variable strain states throughout the BMO-Au film. Owing to the combination of plasmonic Au and layered structure of BMO, the nanocomposite film exhibits a typical LSPR in visible wavelength region and strong anisotropy in terms of its optical and ferromagnetic properties. This study opens a new avenue for developing novel 2D layered complex oxides incorporated with plasmonic metal or semiconductor phases showing great potential for applications in multifunctional nanoelectronics devices.

36 MATERIALS SCIENCE↗

Data-driven picosecond X-ray imaging for quantitative plasma-induced shock characterization

Imaging dynamic events, especially shockwave behavior, is key to advancing high-energy-density (HED) research. Recent advances in fourth- and fifth-generation X-ray light sources allow for high-resolution imaging of fast phenomena, but limited beam time necessitates maximizing data acquisition. We present a benchtop-scale pulsed plasma device submerged in liquid heptane, capable of generating dynamic events at rates exceeding 10 Hz, supporting the field’s data-driven goals by producing large, high-quality imaging datasets. Using X-ray phase contrast imaging (XPCI) at the Advanced Photon Source, we imaged weak shockwaves (Mach ~ 1.2) in heptane interacting with plasma-induced cavitation bubbles, causing deviation from Rankine-Hugoniot behavior; to our knowledge, this represents the first direct imaging of such interaction. Our quantitative analysis offers insight into weak shock phenomena and energy-focusing applications in pulsed plasmas. These results highlight the potential for large datasets to advance dynamic HED research at current light source facilities, and have implications for fields such as inertial confinement fusion, plasma-enhanced chemical processing, and biomedical applications.

36 MATERIALS SCIENCE↗

Imaging perturbed shock propagation in powders

A novel experimental methodology is presented to study the deviatoric response of powders in shock regimes. The powders are confined to a cylindrical wedge volume, and a projectile-driven shock wave with a sinusoidally varying front propagates through the powder. The perturbed shock wave exhibits a damping behavior due to irreversible processes of viscosity and strength (deviatoric) of the powder with propagation through increasing powder thicknesses. The inclined surface of the wedge is polished and coated to establish a diffuse surface suitable for reflecting incident laser light into a high-speed camera imaging at 5 MHz. Images of the contrast loss upon shock wave arrival at the observation surface are post-processed for qualitative and quantitative information. New data of shock damping behavior with parameters of perturbation wavelength and initial shock strength are presented for powders of copper, tantalum, and tungsten carbide as well as their mixtures. We present the first full-field images showing additional spatial disturbances on the perturbed shock front that appear dependent on particle material and morphology.

47 OTHER INSTRUMENTATION↗

Direct observations of shock-induced melting in a porous solid using time-resolved x-ray diffraction

Here in this work we provide direct evidence of shock-induced melting and associated kinetics in a porous solid (aluminum powder) using time-resolved x-ray diffraction. Unambiguous evidence of melting in 50% porous aluminum (Al) powder samples, shocked to peak pressures between ~13 - 19 GPa, was provided by the broadening of the Debye-Scherrer ring corresponding to the (111) peak. Shocked Al powder did not melt completely in any of our experiments within the durations of measurement. Incomplete (partial) melting of the powder, even after several hundreds of nanoseconds of shock loading, provides insights into thermal transport with Al powder particles under high-pressure dynamic loading. Such insights are quite valuable for developing well-constrained melting models and thermodynamic equations of state for porous Al and other porous solids relevant to planetary and materials science.

36 MATERIALS SCIENCE↗

NASA Ames Unitary Plan Wind Tunnel: Infrared Flow Visualization

Infra-red thermography can visualize surface flow features including boundary layer transition, shock impingement, streamwise vortex impingement, flow separation, and buffet. The Infra-red thermography system at the NASA ARC Unitary Plan Wind Tunnel allows for continuous monitoring of wind tunnel models with up to four cameras simultaneously. For best results the models should be covered with a high emissivity coating, and the images processed to enhance contrast. However image processing algorithms allow some flow information to be recovered even from uncoated models.

Garbeff, Ted↗

Quantitative phase microscopy monitors subcellular dynamics in single cells exposed to nanosecond pulsed electric fields

A substantial body of literature exists to study the dynamics of single cells exposed to short duration (<1 μs), high peak power (~1 MV/m) transient electric fields. Much of this research is limited to traditional fluorescence-based microscopy techniques, which introduce exogenous agents to the culture and are only sensitive to a single molecular target. Quantitative phase imaging (QPI) is a coherent imaging modality which uses optical path length as a label-free contrast mechanism, and has proven highly effective for the study of single-cell dynamics. In this work, we introduce QPI as a useful imaging tool for the study of cells undergoing cytoskeletal remodeling after nanosecond pulsed electric field (nsPEF) exposure. In particular, we use cell swelling, dry mass and disorder strength measurements derived from QPI phase images to monitor the cellular response to nsPEFs. We hope this demonstration of QPI's utility will lead to a further adoption of the technique for the study

59 BASIC BIOLOGICAL SCIENCES↗

Compatibility of a Diffractive Pupil and Coronagraphic Imaging

Detection and characterization of exo-earths require direct-imaging techniques that can deliver contrast ratios of 10(exp 10) at 100 milliarc-seconds or smaller angular separation. At the same time, astrometric data is required to measure planet masses and can help detect planets and constrain their orbital parameters. To minimize costs, a single space mission can be designed using a high efficiency coronograph to perform direct imaging and a diffractive pupil to calibrate wide-field distortions to enable high precision astrometric measurements. This paper reports the testing of a diffractive pupil on the high-contrast test bed at the NASA Ames Research Center to assess the compatibility of using a diffractive pupil with coronographic imaging systems. No diffractive contamination was found within our detectability limit of 2x10(exp -7) contrast outside a region of 12lambda/D and 2.5x10(exp -6) within a region spanning from 2 to 12lambda/D. Morphology of the image features suggests that no contamination exists even beyond the detectability limit specified or at smaller working angles. In the case that diffractive contamination is found beyond these stated levels, active wavefront control would be able to mitigate its intensity to 10(exp -7) or better contrast.

Bendek, Eduardo↗

The Potential of Small Space Telescopes for Exoplanet Observations

The imaging of faint exoplanets near bright stars requires the development of very high contrast detection techniques, including both precise wavefront control and deep starlight rejection. A system-level proof-of-principle experiment carried out at at the Palomar Observatory has recently demonstrated that exoplanets can be detected very near stars even with a fairly small (1.5 m diameter) telescope aperture, such as someday might be used by a first space-based exoplanet imaging mission. Using fine-scale wavefront correction across this small aperture, together with fine pointing and focus control, pre- and post-detection speckle reduction, and a vector vortex coronagraph, it has been possible to achieve extremely good starlight rejection within a small number of diffractions beams of the stellar position. This performance has recently allowed the imaging of the three HR8799 planets and the HD32297 disk, thus providing a first system-level validation of the steps needed to achieve high-contrast observations at very small angles. These results thus serve to highlight the potential of small space telescopes aiming at high-contrast exoplanet observations. Specifically, a small-angle coronagraph enables the use of smaller telescopes, thus potentially reducing mission cost significantly.

coronagraphy↗

Multi-microscopy characterization of threading dislocations in CVD-grown diamond films

We present site-coincident imaging of a high dislocation density boron-doped chemical vapor deposition-grown homoepitaxial (001) diamond film using electron channeling contrast imaging (ECCI), cathodoluminescence, transmission electron microscopy (TEM), and scanning secondary ion mass spectroscopy (SIMS). With growing interest in large area heteroepitaxial substrates, we show that ECCI is a promising technique to accurately evaluate dislocations in diamond films. We find the electron backscatter yield is sufficient to distinguish individual threading dislocations in ECCI despite the low atomic number of carbon, and we have generally good agreement between dislocations observed in ECCI and TEM of the same region. Importantly, relying on luminescence in the 430 nm dislocation-related A-band alone results in an underestimation of the defect density as we find only 20%–40% of the threading dislocations luminesce. Here, we further show that dislocations do not perturb the spatial uniformity of boron doping measured by SIMS, even when the dislocations are clustered with high density, and we can tentatively rule out strong segregation effects at the dislocations. Our results establish the complementary use of microscopy and microanalysis methods to rapidly characterize and understand the impact of dislocations in diamond thin films.

36 MATERIALS SCIENCE↗