The Influence of Intraseasonal Oscillations on Humid Heat in the Persian Gulf and South Asia
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The implications of using different control variables for the analysis of moisture observations in a global atmospheric data assimilation system are investigated. A moisture analysis based on either mixing ratio or specific humidity is prone to large extrapolation errors, due to the high variability in space and time of these parameters and to the difficulties in modeling their error covariances. Using the logarithm of specific humidity does not alleviate these problems, and has the further disadvantage that very dry background estimates cannot be effectively corrected by observations. Relative humidity is a better choice from a statistical point of view, because this field is spatially and temporally more coherent and error statistics are therefore easier to obtain. If, however, the analysis is designed to preserve relative humidity in the absence of moisture observations, then the analyzed specific humidity field depends entirely on analyzed temperature changes. If the model has a cool bias in the stratosphere this will lead to an unstable accumulation of excess moisture there. A pseudo-relative humidity can be defined by scaling the mixing ratio by the background saturation mixing ratio. A univariate pseudo-relative humidity analysis will preserve the specific humidity field in the absence of moisture observations. A pseudorelative humidity analysis is shown to be equivalent to a mixing ratio analysis with flow-dependent covariances. In the presence of multivariate (temperature-moisture) observations it produces analyzed relative humidity values that are nearly identical to those produced by a relative humidity analysis. Based on a time series analysis of radiosonde observed-minus-background differences it appears to be more justifiable to neglect specific humidity-temperature correlations (in a univariate pseudo-relative humidity analysis) than to neglect relative humidity-temperature correlations (in a univariate relative humidity analysis). A pseudo-relative humidity analysis is easily implemented in an existing moisture analysis system, by simply scaling observed-minus background moisture residuals prior to solving the analysis equation, and rescaling the analyzed increments afterward.
Temperature and humidity profiles are needed to estimate surface radiation budget. The Clouds and the Earth’s Radiant Energy System (CERES) team uses temperature and humidity profiles from a reanalysis product produced by NASA’s Global Modeling and Assimilation Office for surface irradiance computations. Biases and drifts in temperature and humidity profiles in the reanalysis product result in biases and drifts in surface irradiances computed with them. One approach to correct biases and drifts in temperature and humidity profile is to use satellite observations, similar to assimilating instantaneous spectral radiances to correct modeled temperature and humidity profiles. In this work, we use mean spectral radiances to test the possibility of understanding biases in reanalysis mean temperature and humidity profiles. Specifically, we use 16-day mean Atmospheric Infrared Sounder (AIRS) radiances and only use clear-sky spectral radiances with a viewing zenith angle nadir to near-nadir. We use the dual-regression method (Smith et al. 2012) to test whether temperature and humidity profiles retrieved from the 16-day mean spectral radiances agree with the average of temperature and humidity profiles derived from instantaneous spectral radiances. When daytime and nighttime spectral radiances are averaged separately and daytime and nighttime retrievals are performed separately, temperature and humidity profiles derived from the mean spectral radiances agree well with mean temperature and humidity profiles derived from instantaneous spectral radiances. The agreement improves when clouds are further screened to compute 16-day mean clear-sky spectral radiances.
Land-atmosphere coupling (LAC) has long been studied focusing on land surface and atmospheric boundary layer processes. However, the influence of lower tropospheric (LT) humidity on LAC remains largely unexplored. In this study, we use radiosonde observations from the U.S. Southern Great Plains (SGP) site and an entrained parcel buoyancy model to investigate the impact of LT humidity on LAC there during the warm season (May–September). We quantify the effect of LT humidity on convective buoyancy by measuring the difference between the 2–4 km vertically integrated buoyancy with and without the influence of background LT humidity. Our results show that, under dry soil conditions, anomalously high LT humidity is necessary to produce the buoyancy profiles required for afternoon precipitation events (APEs). These APEs under dry soil moisture cannot be explained by commonly used local land-atmosphere coupling indices such as the convective triggering potential/low-level humidity index (CTP/HI Low ), which do not account for the influence of the LT humidity. On the other hand, consideration of LT humidity is unnecessary to explain APEs under wet soil moisture conditions, suggesting the boundary layer moisture alone could be sufficient to generate the required buoyancy profiles. These findings highlight the need to consider the impact of LT humidity, which is often decoupled from the humidity near the surface and largely controlled by moisture transport, in understanding land-atmospheric feedbacks over dry soil conditions, especially during droughts or dry spells over the SGP.
Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.
Observations of upper tropospheric relative humidity obtained from Raman lidar and Cross-chain Loran Atmospheric Sounding System (CLASS) sonde instruments obtained during the First ISCCP Regional Experiment (FIRE) Cirrus-II field program are compared with satellite measurements from the GOES 6.7-micron channel. The 6.7-micron channel is sensitive to water vapor integrated over a broad layer in the upper troposphere (roughly 500-200 mbar). Instantaneous measurements of the upper tropospheric relative humidity from GOES are shown to agree to within roughly 6% of the nearest lidar observations and 9% of the nearest CLASS observations. The CLASS data exhibit a slight yet systematic dry bias in upper tropospheric humidity, a result which is consistent with previous radiosonde intercomparisons. Temporal stratification of the CLASS data indicates that the magnitude of the bias is dependent upon the time of day, suggesting a solar heating effect in the radiosonde sensor. Using CLASS profiles, the impact of vertical variability in relative humidity upon the GOES upper tropospheric humidity measurements is also examined. The upper tropospheric humidity inferred from the GOES 6.7-micron channel is demonstrated to agree to within roughly 5% of the relative humidity vertically averaged over the depth of atmosphere to which the 6.7-micron channel is sensitive. The results of this study encourage the use of satellite measurements in the 6.7-micron channel to quantitatively describe the distribution and temporal evolution of the upper tropospheric humidity field.
A description of the corrosion behavior of aluminum alloys used for cladding on aluminum-based, aluminum-clad nuclear fuel used in research reactors under potential dry storage conditions has been compiled. An evaluation is made of potential additional corrosion with water postulated to not be removed during drying. The relative humidity (RH) produced by typical dryness criteria for industrial spent nuclear fuel drying is expected to be low, particularly at high temperatures (17% RH at 20°C and lower at higher temperatures). Existing corrosion data suggests that negligible vapor-phase corrosion of aluminum is expected at such low humidity, even for nominally bare aluminum surfaces. That is, the predicted relative humidity from free water (e.g., 17% RH) is below the “critical” relative humidity (~40% RH at room temperature), below which no significant corrosion is observed for bare aluminum. Furthermore, reported room-temperature corrosion rates are very low even under saturated (100% RH) water vapor. Existing results showing significant vapor-phase corrosion corresponded specifically to conditions of high temper ed with high relative humidity. A relatively large reservoir of (chemically bound) water exists in the aluminum (oxy)hydroxide films on the SNF cladding surface. The estimated total could saturate the gas even at relatively high temperature if fully released; however, its release as molecular water is expected to only be plausible if the temperature during storage exceeds both the drying temperature and the threshold for thermal decomposition of the trihydroxides (~220°C). Therefore, the combination of high temperature and high relative humidity that could drive significant corrosion is considered implausible during sealed dry storage following an appropriate drying process, to include >220°C drying for canisters that may approach or exceed this temperature during storage. Vapor-phase testing of aluminum samples with an adherent (oxy)hydroxide layer, prepared in liquid water to resemble those on actual aluminum-clad spent nuclear fuel (ASNF), did not observe evidence of additional corrosion even at combined high-temperature (up to 180°C) and high-humidity (up to 100% RH) conditions. Instead, small net mass losses were observed for most specimens and attributed to dehydration of the samples, which had been air-dried only prior to testing. ASNF being moved to dry storage is expected to have an existing (oxy)hydroxide film, suggesting that the cladding will be less prone to additional corrosion than bare aluminum metal. If significant corrosion did occur during sealed storage, the overall extent and impact is expected to be small. Corrosion post-closure of a canister would not alter the total amount of hydrogen in the canister, so it would have no effect on the maximum H 2 release already assessed in existing bounding calculations. In addition, the total amount of water in a 25-µm dense bayerite film would consume a only ~8 µm additional aluminum metal on average, if fully consumed by oxidizing aluminum metal to Al 2 O 3 . These conclusions are consistent with ASNF-in-canister simulations to date, which included a reaction pathway for corrosion using kinetics from previous literature and believed to be conservative and predicted very low rates of corrosion.
Infrared and visible HCMM data were used to examine the potential application of these data to define initial and boundary conditions for mesoscale numerical models. Various boundary layer models were used to calculate the distribution of the surface heat flux, specific humidity depression (the difference between the specific humidity in the air at approxmately the 10 m level and the specific humidity at the ground), and the eddy vicosity in a 72 km by 72 km area centered about St. Louis, Missouri. Various aspects of the implications of the results on the meteorology of St. Louis are discussed. Overall, the results indicated that a reasonable estimate of the surface heat flux, urban albedo, ground temperature, and specific humidity depression can be obtained using HCMM satellite data. Values of the ground-specific humidity can be obtained if the distribution of the air-specific humidity is available. More research is required in estimating the absolute magnitude of the specific humidity depression because calculations may be sensitive to model parameters.
The effects of humidity (water-vapor) in nitrogen on the friction and deformation behavior of magnetic tape in contact with a Ni-Zn ferrite spherical pin were studied. The coefficient of friction is markedly dependent on the ambient relative humidity. In elastic contacts the coefficient of friction increased linearly with increasing humidity; it decreased linearly when humidity was lowered. This effect is the result of changes in the chemistry and interaction of tape materials such as degradation of the lubricant. In plastic contacts there was no effect of humidity on friction below 40 percent relative humidity. There is no effect on friction associated with the breakthrough of the adsorbed water-vapor film at the interface of the tape and Ni-Zn ferrite. The coefficient of friction, however, increased rapidly with increasing relative humidity above 40 percent in plastic contacts.
We reexamine the aerosol semidirect effect using a general circulation model and four cases of the single-scattering albedo of dust aerosols. Contrary to the expected decrease in low cloud cover due to heating by tropospheric aerosols, we find a significant increase with increasing absorptivity of soil dust particles in regions with high dust load, except during Northern Hemisphere winter. The strongest sensitivity of cloud cover to dust absorption is found over land during Northern Hemisphere summer. Here even medium and high cloud cover increase where the dust load is highest. The cloud cover change is directly linked to the change in relative humidity in the troposphere as a result of contrasting changes in specific humidity and temperature. More absorption by aerosols leads to larger diabatic heating and increased warming of the column, decreasing relative humidity. However, a corresponding increase in the specific humidity exceeds the temperature effect on relative humidity. The net effect is more low cloud cover with increasing aerosol absorption. The higher specific humidity where cloud cover strongly increases is attributed to an enhanced convergence of moisture driven by dust radiative heating. Although in some areas our model exhibits a reduction of low cloud cover due to aerosol heating consistent with the conventional description of the semidirect effect, we conclude that the link between aerosols and clouds is more varied, depending also on changes in the atmospheric circulation and the specific humidity induced by the aerosols. Other absorbing aerosols such as black carbon are expected to have a similar effect.
The effects of humidity of moist nitrogen on the friction and deformation behavior of magnetic tape in contact with a nickel-zinc ferrite spherical pin were studied. The results indicate that the coefficient of friction is markedly dependent on the ambient relative humidity. Although the coefficient of friction remains low below 40-percent relative humidity, it increases rapidly with increasing relative humidity above 40 percent. The general ambient environment of the tape does not have any effect on the friction behavior if the area where the tape is in sliding contact with the ferrite pin is flooded with controlled nitrogen. The response time for the friction of the tape to humidity changes is about 10 sec. The effect of friction as a function of relative humidity on dehumidifying is very similar to that on humidifying. A surface softening of the tape due to water vapor increases the friction of the tape.
An extensive statistical analysis has been undertaken to determine if a correlation exists between changes in an NR atomic hydrogen muser's frequency offset and changes in environmental conditions. Data have been acquired over the past 20 months by recording the frequency offset of three NR atomic hydrogen masers along with the relative and absolute humidity, barometric pressure, and ambient temperature of the laboratory in which the masers are maintained. Correlational analyses have been performed comparing barometric pressure, humidity, and temperature with maser frequency offset as functions of time for periods ranging from 5.5 to 17 days. Semi partial correlation coefficients as large as -0.9 have been fond between barometric pressure and maser frequency offset for data covering periods as long as a week. Maser frequency offset and barometric pressure were consistently found to change simultaneously. The correlation between humidity and frequency offset is less predictable, and the resulting semi partial correlation coefficients were usually small when compared with those derived from the relationship between pressure and frequency offset. The time delay between changes in humidity and correlated changes in maser frequency offset was found to vary extensively with no predictable pattern. Analysis of temperature data indicates that, in the most current design, temperature does not significant(y affect maser frequency offset in the laboratory environment. Thus, the results of the analyses disclose a significant statistical correlation between changes in maser frequency offset and changes in barometric pressure. The statistics also reveal some correlation between humidity and frequency offset, bat for reasons to be discussed, the effects of humidity should be considered secondary to the effects of changing barometric pressure.
Uncertainties in the aerosol single scattering albedo have been identified to be an important source of errors in current large-scale model estimates of the direct aerosol radiative forcing of climate. A number of investigators have obtained estimates of the single scattering albedo from a variety of remote sensing and in situ measurements during aerosol field experiments. During the Tropospheric Aerosol Radiative Forcing Observational Experiment (TARFOX, 1996) for example, estimates of the aerosol single scattering albedo were obtained (1) as a best-fit parameter in comparing radiative flux changes measured by airborne pyranometer to those computed from independently measured aerosol properties; (2) from estimates of the aerosol complex index of refraction derived using a combination of airborne sunphotometer, lidar backscatter and in situ size distribution measurements; and (3) from airborne measurements of aerosol scattering and absorption using nephelometers and absorption photometers. In this paper, we briefly compare the results of the latter two methods for two TARFOX case studies, since those techniques provide height-resolved information about the aerosol single scattering albedo. Estimates of the aerosol single scattering albedo from nephelometer and absorption photometer measurements require knowledge of the scattering and absorption humidification (i.e., the increase in these properties in response to an increase in ambient relative humidity), since both measurements are usually carried out at a relative humidity different from the ambient atmosphere. In principle, the scattering humidification factor can be measured, but there is currently no technique widely available to measure the absorption of an aerosol sample as a function of relative humidity. Frequently, for lack of better knowledge, the absorption humidification is assumed to be unity (meaning that there is no change in aerosol absorption due to an increase in ambient relative humidity). This assumption then enters the estimate of the single scattering albedo at ambient relative humidity. To investigate the validity of this assumption we have carried out modeling studies of the absorption humidification factor, assuming that the aerosols contain an insoluble soot core and a coating which determines its hygroscopic growth behavior. The aerosol optical properties are then computed on the basis of the shell/core particle morphology using a Mie-code for concentric shells. From basic physical principles, it is conceivable that aerosol absorption increases when an atmospheric aerosol particle collects a non-absorbing shell, since the soot core is then exposed to an increased (focused) electric field strength. Indeed, our preliminary modeling studies show that the absorption of an atmospheric aerosol particle composed of a soot core and an aqueous sulfuric acid shell may increase by a factor of 50% due to a change in ambient relative humidity from 30 to 95%. We will show how this increased absorption is a function of the initial particle size and soot mass fraction.
The ability to control the temperature and humidity of an environment or habitat is critical for human survival. These factors are important to maintaining human health and comfort, as well as maintaining mechanical and electrical equipment in good working order to support the human and to accomplish mission objectives. The temperature and humidity of the International Space Station (ISS) United States On-orbit Segment (USOS) cabin air is controlled by the Common Cabin Air Assembly (CCAA). The CCAA consists of a fan, a condensing heat exchanger (CHX), an air/water separator, temperature and liquid sensors, and electrical controlling hardware and software. The CHX is the primary component responsible for control of temperature and humidity. The CCAA CHX contains a chemical coating that was developed to be hydrophilic and thus attract water from the humid influent air. This attraction forms the basis for water removal and therefore cabin humidity control. However, there have been several instances of CHX coatings becoming hydrophobic and repelling water. When this behavior is observed in an operational CHX, the unit s ability to remove moisture from the air is compromised and the result is liquid water carryover into downstream ducting and systems. This water carryover can have detrimental effects on the cabin atmosphere quality and on the health of downstream hardware. If the water carryover is severe and widespread, this behavior can result in an inability to maintain humidity levels in the USOS. This paper will describe the operation of the five CCAAs within in the USOS, the potential causes of the hydrophobic condition, and the impacts of the resulting water carryover to downstream systems. It will describe the history of this behavior and the actual observed impacts to the ISS USOS. Information on mitigation steps to protect the health of future CHX hydrophilic coatings and potential remediation techniques will also be discussed.
An ambient temperature oxygen microsensor, based on a Nafion polymer electrolyte, has been developed and was microfabricated using thin-film technologies. A challenge in the operation of Nafion-based sensor systems is that the conductivity of Nafion film depends on the humidity in the film. Nafion film loses conductivity when the moisture content in the film is too low, which can affect sensor operation. The advancement here is the identification of a method to retain the operation of the Nafion films in lower humidity environments. Certain salts can hold water molecules in the Nafion film structure at room temperature. By mixing salts with the Nafion solution, water molecules can be homogeneously distributed in the Nafion film increasing the film s hydration to prevent Nafion film from being dried out in low-humidity environment. The presence of organics provides extra sites in the Nafion film to promote proton (H+) mobility and thus improving Nafion film conductivity and sensor performance. The fabrication of ambient temperature oxygen microsensors includes depositing basic electrodes using noble metals, and metal oxides layer on one of the electrode as a reference electrode. The use of noble metals for electrodes is due to their strong catalytic properties for oxygen reduction. A conducting polymer Nafion, doped with water-retaining components and extra sites facilitating proton movement, was used as the electrolyte material, making the design adequate for low humidity environment applications. The Nafion solution was coated on the electrodes and air-dried. The sensor operates at room temperature in potentiometric mode, which measures voltage differences between working and reference electrodes in different gases. Repeat able responses to 21-percent oxygen in nitrogen were achieved using nitrogen as a baseline gas. Detection of oxygen from 7 to 21 percent has also been demonstrated. The room-temperature oxygen micro sensor developed has extremely low power consumption (no heating for operation, no voltage applied to the sensor, only a voltmeter is needed to measure the output), is small in size, is simple to batch-fabricate, and is high in sensor yield. It is applicable in a wide humidity range, with improved operation in low humidity after the additives were added to the Nafion film. Through further improvement and development, the sensor can be used for aerospace applications such as fuel leak detection, fire detection, and environmental monitoring.
The ability to control the temperature and humidity of an environment or habitat is critical for human survival. These factors are important to maintaining human health and comfort, as well as maintaining mechanical and electrical equipment in good working order to support the human and to accomplish mission objectives. The temperature and humidity of the International Space Station (ISS) United States On-orbit Segment (USOS) cabin air is controlled by the Common Cabin Air Assembly (CCAA). The CCAA consists of a fan, a condensing heat exchanger (CHX), an air/water separator, temperature and liquid sensors, and electrical controlling hardware and software. The CHX is the primary component responsible for control of temperature and humidity. The CCAA CHX contains a chemical coating that was developed to be hydrophilic and thus attract water from the humid influent air. This attraction forms the basis for water removal and therefore cabin humidity control. However, there have been several instances of CHX coatings becoming hydrophobic and repelling water. When this behavior is observed in an operational CHX in the ISS segments, the unit s ability to remove moisture from the air is compromised and the result is liquid water carryover into downstream ducting and systems. This water carryover can have detrimental effects on the ISS cabin atmosphere quality and on the health of downstream hardware. If the water carryover is severe and widespread, this behavior can result in an inability to maintain humidity levels in the USOS. This paper will describe the operation of the five CCAAs within the USOS, the potential causes of the hydrophobic condition, and the impacts of the resulting water carryover to downstream systems. It will describe the history of this behavior and the actual observed impacts to the ISS USOS. Information on mitigation steps to protect the health of future CHX hydrophilic coatings as well as remediation and recovery of the full heat exchanger will be discussed.