Search NASA⌕ Search

SEARCH · Search NASA

Results for “INDUCTANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Performance of a phonon-mediated kinetic inductance detector at the NEXUS cryogenic facility

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the Northwestern EXerimental Underground Site (NEXUS) low-background facility at Fermilab for characterization and evaluation of this detector architecture’s efficacy for a DM search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470-nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of 2.1 ± 0.2 eV, a factor of two better than the current state of the art, enabled by quasiparticle lifetimes extending up to 6.5 ms. However, due to the subpercent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to σ E = 318 ± 29 eV. We further model both the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, and the observed noise spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-Wave Mixing Kinetic Inductance Traveling-Wave Amplifier with Near-Quantum-Limited Noise Performance

We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave (KIT) amplifier, whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, this amplifier operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT amplifier devices. It consists of a 50 Ω artificial transmission line whose dispersion allows for a controlled amplification bandwidth. We measure $16.5^{+1}_{–1.3}$ dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of –63 dBm, in qualitative agreement with theory. Using a theoretical framework that accounts for the SNTJ-generated noise entering both the signal and idler ports of the KIT amplifier, we measure the system-added noise of an amplification chain that integrates the KIT amplifier as the first amplifier. This system-added noise, 3.1 ± 0.6 quanta (equivalent to 0.66 ± 0.15 K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see. This KIT amplifier is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.

42 ENGINEERING↗

A compact and flexible induction furnace for in situ X-ray microradiograhy and computed microtomography at Elettra: design, characterization and first tests

A compact and versatile induction furnace for in situ high-resolution synchrotron and laboratory hard X-ray microradiography and computed microtomography is described. The furnace can operate from 773 to 1723 K. Its programmable controller enables the user to specify multiple heating and cooling ramp rates as well as variable dwell times at fixed temperatures allowing precise control of heating and cooling rates to within 5 K. The instrument can work under a controlled atmosphere. Thanks to the circular geometry of the induction coils, the heat is homogeneously distributed in the internal volume of the graphite cell ( ca . 150 mm 3 ) where the sample holder is located. The thermal gradient within the furnace is less than 5 K over a height of ca . 5 mm. This new furnace design is well suited to the study of melting and solidification processes in geomaterials, ceramics and several metallic alloys, allowing fast heating (tested up to 6.5 K s -1 ) and quenching (up to 21 K s -1 ) in order to freeze the sample microstructure and chemistry under high-temperature conditions. The sample can be held at high temperatures for several hours, which is essential to follow phenomena with relatively slow dynamics, such as crystallization processes in geomaterials. The utility of the furnace is demonstrated through a few examples of experimental applications performed at the Elettra synchrotron laboratory (Trieste, Italy).

Kudrna Prašek, Marko↗

Understanding middle-point inductance's effect on switching transients for multi-chip SiC package design with P-cell/N-cell concept

Middle-point inductance L_middle can be introduced in power module designs with P-cell/N-cell concept. In this paper, the effect of middle-point inductance on switching transients is analyzed first using frequency domain analysis. Then a dedicated multiple-chips power module is fabricated with the capability of varying L_middle, and extensive switching tests are conducted to evaluate the device’s switching performance at different L_middle. Experiment results show that as L_middle changes, different voltage stresses are imposed on the active switch and anti-parallel diode. For lower MOSFET’s turn-off, as L_middle goes up, the maximum voltage of lower MOSFET increases; however, the maximum voltage of anti-parallel diode decreases significantly. In addition to voltage spikes, it is observed that the active MOSFET’s turn-on loss will decrease at higher values of L_middle while its turn-off loss will increase. Detailed analysis of this loss variation is presented. The analysis and experiment results will provide design guidelines for multiple-chips power module package design with P-cell/N-cell concept.

Yang, Fei↗

Encapsulation Residual Stress and Ferrite Loss in Inductive Coil Assemblies

As inductive wireless charging reaches higher power levels, thermal management and mechanical durability become more critical. To address these concerns, past works have demonstrated the benefit of encapsulating coil assemblies in thermally conductive materials. However, due to the sensitivity of the MnZn ferrites commonly used in coil assemblies to mechanical stress, care must be taken to avoid creating large stresses in the ferrite that cause higher hysteresis loss. The stress formation in the encapsulant curing process is overviewed and modeled and an experiment is performed to demonstrate the effect in a small-scale coil assembly. Finally, the effect is shown in the reduced coil-coil efficiency of a first generation high power inductive power transfer prototype using a stiff epoxy compared to better performance in a second prototype using a softer thermally-conductive silicone encapsulant.

Foote, Andrew↗

Sensitivity Analysis and Control of Induction Cooktop for Non-Ferromagnetic Cookware

All metal induction cooktop has the potential to enable heating of both ferromagnetic and non-ferromagnetic cookware. Compared to ferromagnetic cookware, the performance of an induction cooktop with non-ferromagnetic cookware is impacted significantly by the cookware misalignment. A detailed sensitivity analysis to the cookware misalignment for non-ferromagnetic cookware is studied in this paper. Based on the analysis, a control architecture is presented which ensures desired power transfer to the non-ferromagnetic cookware and zero voltage turn on of the high frequency inverter irrespective of cookware misalignment. Results are presented to verify the analysis and proposed control strategy.

Mukherjee, Subho [ORNL] (ORCID:0009000672297925)↗

Integrated Magnetics for Multiport Inductive and Conductive Power Transfer Architecture for Electric Vehicles

This paper proposes a shared magnetic arrangement for an electric-vehicle charger that supports both conductive and inductive charging while preserving independent power control at the two ports. In the proposed implementation, the high-frequency transformer used for the conductive path and the resonant inductor required by the inductive path are realized in an integrated form. By combining the magnetic structure and primary-side converter hardware, the charger can deliver improved hardware utilization and higher power density without a corresponding increase in cost or implementation complexity. The paper describes the magnetic realization and presents finite-element and circuit-level simulation results to confirm minimal interaction between the two charging paths. The study demonstrates that the proposed charger is a viable option for flexible, high-power EV charging systems.

Mukherjee, Subho [ORNL] (ORCID:0009000672297925)↗

Methodology of Low Inductance Busbar Design for Three-Level Converters

Three-level (3L) converters are more susceptible to parasitics compared with two-level converters because of their complicated structure with multiple switching loops. In this article, the methodology of busbar layout design for 3L converters based on the magnetic cancellation effect is presented. The methodology can fit for 3L converters with symmetric and asymmetric configurations. A detailed design example is provided for a high-power 3L-active neutral point clamped (ANPC) converter, which includes the module selection, busbar layout, and dc-link capacitor placement. The loop inductance of the busbar is verified with simulation, impedance measurements, and converter experiments. Furthermore, the results match with each other, and the inductances of short and long loops are 6.5 and 17.5 nH, respectively, which are significantly lower than the busbars of NPC-type converters in other references.

42 ENGINEERING↗

Electromagnetic Properties of Aluminum-based Bilayers for Kinetic Inductance Detectors

The complex conductivity of a superconducting thin film is related to the quasiparticle density, which depends on the physical temperature and can also be modified by external pair breaking with photons and phonons. This relationship forms the underlying operating principle of Kinetic Inductance Detectors (KIDs), where the detection threshold is governed by the superconducting energy gap. We investigate the electromagnetic properties of thin-film aluminum that is proximitized with either a normal metal layer of copper or a superconducting layer with a lower T-C, such as iridium, in order to extend the operating range of KIDs. Using the Usadel equations along with the Nam expressions for complex conductivity, we calculate the density of states and the complex conductivity of the resulting bilayers to understand the dependence of the pair breaking threshold, surface impedance, and intrinsic quality factor of superconducting bilayers on the relative film thicknesses. The calculations and analyses provide theoretical insights in designing aluminum-based bilayer kinetic inductance detectors for detection of microwave photons and athermal phonons at the frequencies well below the pair breaking threshold of a pure aluminum film.

complex conductivity↗

Smart Inverter Stability Enhancement in Weak Grids Using Adaptive Virtual-Inductance

An adaptive virtual-inductance feedforward scheme is presented in this article to enhance the stable operation of smart inverters in weak grids. In the developed scheme, the virtual inductance is updated in real time according to an adaptation law to ensure that the inverter follows the dynamic response of a robust reference model, thereby ensuring stability without the need for any grid impedance estimation. In this article, the developed scheme is validated with experimental results obtained from testing a small-scale two-level, 208-V, 2-kW inverter.

42 ENGINEERING↗

Thermocouples in Resistive and Induction Furnaces Operated in Strong Magnetic Fields

The thermomagnetic processing methods require an understanding of the in situ temperatures experienced by the workpieces. When commonly used thermocouples (TCs) are employed in induction furnaces, RF fields can contribute additional temperature uncertainties to the ones arising from the use of strong magnetic fields. Focusing on temperatures between 300 ° C and 1000 ° C produced by induction and resistive furnaces, the readings generated by Type-K TCs were contrasted to the ones produced by Type-S and Type-N sensors for magnetic fields up to 9 T. Overall, when comparing Type-K response to temperatures above 700 ° C in both zero field and high field ( ≤9 T), the differences amounted to less than 1% and when continuously measured has a linear relationship to the strength of the applied field. The relative invariance of Type-N and Type-S TCs was confirmed. In conclusion, these findings suggest that the use of TCs in high magnetic fields remains a viable option for applications, although the precision depends on the type used.

Tener, Zachary P. [Oak Ridge National Laboratory (↗

Ion flux and ion distribution function measurements in synchronously pulsed inductively coupled plasmas

Changes in the ion flux and the time-averaged ion distribution functions are reported for pulsed, inductively coupled RF plasmas (ICPs) operated over a range of duty cycles. For helium and argon plasmas, the ion flux increases rapidly after the start of the RF pulse and after about 50 {mu}s reaches the same steady state value as that in continuous ICPs. Therefore, when the plasma is pulsed at 1 kHz, the ion flux during the pulse has a value that is almost independent of the duty cycle. By contrast, in molecular electronegative chlorine/chlorosilane plasmas, the ion flux during the pulse reaches a steady state value that depends strongly on the duty cycle. This is because both the plasma chemistry and the electronegativity depend on the duty cycle. As a result, the ion flux is 15 times smaller in a pulsed 10% duty cycle plasma than in the continuous wave (CW) plasma. The consequence is that for a given synchronous RF biasing of a wafer-chuck, the ion energy is much higher in the pulsed plasma than it is in the CW plasma of chlorine/chlorosilane. Under these conditions, the wafer is bombarded by a low flux of very energetic ions, very much as it would in a low density, capacitively coupled plasma. Therefore, one can extend the operating range of ICPs through synchronous pulsing of the inductive excitation and capacitive chuck-bias, offering new means by which to control plasma etching.

74 ATOMIC AND MOLECULAR PHYSICS↗

Study on spatial distribution of plasma parameters in a magnetized inductively coupled plasma

Spatial distributions of various plasma parameters such as plasma density, electron temperature, and radical density in an inductively coupled plasma (ICP) and a magnetized inductively coupled plasma (M-ICP) were investigated and compared. Electron temperature in between the rf window and the substrate holder of M-ICP was higher than that of ICP, whereas the one just above the substrate holder of M-ICP was similar to that of ICP when a weak (<8 G) magnetic field was employed. As a result, radical densities in M-ICP were higher than those in ICP and the etch rate of oxide in M-ICP was faster than that in ICP without severe electron charging in 90 nm high aspect ratio contact hole etch.

36 MATERIALS SCIENCE↗

TU-EF-BRA-03: Free Induction Decay (without the Decay) and Spin-Echo Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP3-02: Benchmarks of a Proton Relative Biological Effectiveness (RBE) Model for DNA Double Strand Break (DSB) Induction in the FLUKA, MCNP, TOPAS, and RayStation™ Treatment Planning System

Purpose: Validate implementation of a published RBE model for DSB induction (RBEDSB) in several general purpose Monte Carlo (MC) code systems and the RayStation™ treatment planning system (TPS). For protons and other light ions, DSB induction is a critical initiating molecular event that correlates well with the RBE for cell survival. Methods: An efficient algorithm to incorporate information on proton and light ion RBEDSB from the independently tested Monte Carlo Damage Simulation (MCDS) has now been integrated into MCNP (Stewart et al. PMB 60, 8249–8274, 2015), FLUKA, TOPAS and a research build of the RayStation™ TPS. To cross-validate the RBEDSB model implementation LET distributions, depth-dose and lateral (dose and RBEDSB) profiles for monodirectional monoenergetic (100 to 200 MeV) protons incident on a water phantom are compared. The effects of recoil and secondary ion production ({sub 2}H{sub +}, {sub 3}H{sub +}, {sub 3}He{sub 2+}, {sub 4}He{sub 2+}), spot size (3 and 10 mm), and transport physics on beam profiles and RBEDSB are examined. Results: Depth-dose and RBEDSB profiles among all of the MC models are in excellent agreement using a 1 mm distance criterion (width of a voxel). For a 100 MeV proton beam (10 mm spot), RBEDSB = 1.2 ± 0.03 (− 2–3%) at the tip of the Bragg peak and increases to 1.59 ± 0.3 two mm distal to the Bragg peak. RBEDSB tends to decrease as the kinetic energy of the incident proton increases. Conclusion: The model for proton RBEDSB has been accurately implemented into FLUKA, MCNP, TOPAS and the RayStation™TPS. The transport of secondary light ions (Z > 1) has a significant impact on RBEDSB, especially distal to the Bragg peak, although light ions have a small effect on (dosexRBEDSB) profiles. The ability to incorporate spatial variations in proton RBE within a TPS creates new opportunities to individualize treatment plans and increase the therapeutic ratio. Dr. Erik Traneus is employed full-time as a Research Scientist at RaySearch Laboratories. The research build of the RayStation used in the study was made available to the University of Washington free of charge. RaySearch Laboratories did not provide any monetary support for the reported studies.

60 APPLIED LIFE SCIENCES↗

Latched detection of zeptojoule spin echoes with a kinetic inductance parametric oscillator

When strongly pumped at twice their resonant frequency, nonlinear resonators develop a high-amplitude intracavity field, a phenomenon known as parametric self-oscillations. The boundary over which this instability occurs can be extremely sharp and thereby presents an opportunity for realizing a detector. Here, we operate such a device based on a superconducting microwave resonator whose nonlinearity is engineered from kinetic inductance. The device indicates the absorption of low-power microwave wavepackets by transitioning to a self-oscillating state. Using calibrated pulses, we measure the detection efficiency to zeptojoule energy wavepackets. We then apply it to measurements of electron spin resonance, using an ensemble of 209 Bi donors in silicon that are inductively coupled to the resonator. We achieve a latched readout of the spin signal with an amplitude that is five hundred times greater than the underlying spin echoes.

42 ENGINEERING↗

On coincident loop transient electromagnetic induction logging

Coincident loop transient induction wireline logging is examined as the borehole analog of the well-known land and airborne time-domain electromagnetic (EM) method. The concept of whole-space late-time apparent resistivity is modified from the half-space version commonly used in land and airborne geophysics and applied to the coincident loop voltages produced from various formation, borehole, and invasion models. Given typical tool diameters, off-time measurements with such an instrument must be made on the order of nanoseconds to microseconds — much more rapidly than for surface methods. Departure curves of the apparent resistivity for thin beds, calculated using an algorithm developed to model the transient response of a loop in a multilayered earth, indicate that the depth of investigation scales with the bed thickness. Modeled resistivity logs are comparable in accuracy and resolution with standard frequency-domain focused induction logs. However, if measurement times are longer than a few microseconds, the thicknesses of conductors can be overestimated, whereas resistors are underestimated. Thin-bed resolution characteristics are explained by visualizing snapshots of the EM fields in the formation, where a conductor traps the electric field while two current maxima are produced in the shoulder beds surrounding a resistor. Radial profiling is studied using a concentric cylinder earth model. Results found that true formation resistivity can be determined in the presence of either oil- or water-based mud, although in the latter case, measurements must be taken several orders of magnitude later in time. Lastly, the ability to determine true formation resistivity is governed by the degree that the EM field heals after being distorted by borehole fluid and invasion, a process visualized and particularly evident in the case of conductive water-based mud.

58 GEOSCIENCES↗

A Phase 2 Study of Induction Chemotherapy Using Docetaxel, Cisplatin, and S-1 for Gastric Cancer with Peritoneal Metastasis (KUGC06)

Background: The authors previously showed the significant efficacy of S-1 plus cisplatin for gastric cancer with limited peritoneal metastasis. They conducted a phase 2 study to evaluate the safety and efficacy of induction chemotherapy using a docetaxel, cisplatin, and S-1 (DCS) triplet regimen to treat gastric cancer with peritoneal metastasis. Methods: The key eligibility criteria were gastric cancer with peritoneal metastasis or positive peritoneal cytology but no other distant metastases and capability of oral administration. The patients received three 28-day cycles of DCS (60 mg/m{sup 2} of cisplatin, 40 mg/m{sup 2} of docetaxel on day 1, and 80 mg/m{sup 2} of S-1 from day 1 to day 14), then underwent D2 gastrectomy if R0 was possible. The primary end point was the R0 resection rate. The sample size was determined to have 80% power for detecting a 20% improvement in the R0 resection rate over a 45% baseline for a one-tailed alpha of 0.1. Results: Among 30 enrolled patients, 24 completed three cycles of DCS. The most frequent grade 3 or 4 toxicity was neutropenia (60%). A complete response of peritoneal metastasis was observed in 16 patients, and 14 patients achieved R0 resection (47%; 95% confidence interval 28–66%). When the extent of peritoneal metastasis was classified as P0CY1, P1, P2, and P3 according to the Japanese classification, the R0 resection rates were respectively 63%, 60%, 46% and 0%. Conclusions: Induction chemotherapy with DCS is safe and can achieve R0 resection for some patients with limited peritoneal metastasis or positive peritoneal cytology. The efficacy, however, appears similar to that of S-1 plus cisplatin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗