Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ERROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

$Z$-Pinch Interferometry Analysis With the Fourier-Based TNT Code

Here, we present the analysis of interferometry diagnostics with the user-friendly Talbot Numerical Tool (TNT), a Fourier-based postprocessing code that enables real-time assessment of plasma systems. TNT performance was explored with visible and infrared interferometry in pulsed-power-driven Z -pinch configurations to expand its capabilities beyond Talbot X-ray interferometry in the high-intensity laser environment. TNT enabled accurate electron density characterization of magnetically driven plasma flows and shocks through phase-retrieval methods that did not require data modification or masking. TNT demonstrated enhanced resolution, detecting below 4 % fringe shift, which corresponds to 8.7 × 10 15 cm –2 within 28 μ m, approaching the laser probing system limit. TNT was tested against a well-known interferometry analysis software, delivering an average resolving power nearly ten times better (~28 μ m versus ~ 210 μ m) when resolving plasma ablation features. TNT demonstrated higher sensitivity when probing sharp electron density gradients in supersonic shocks. A maximum electron areal density of 4.1 × 10 17 cm –2 was measured in the shocked plasma region, and a minimum electron density detection of ~ 1.0 × 10 15 cm –2 was achieved. When probing colliding plasma flows, the calculations of the effective adiabatic index and the associated errors were improved from γ* = 2.6 ± 1.6 – 1.4 ± 0.2 with TNT postprocessing, contributing valuable data for the interpretation of radiative transport. Additional applications of TNT in the characterization of pulsed-power plasmas and beyond are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multifunctional light beam source for surface slope measuring long trace profilers

To fully exploit the advantages of fourth-generation synchrotron light sources, diffraction-limited-storage-rings (DLSR) and fully coherent free electron lasers (FELs), beamline mirrors and diffraction grating must be of exceptional quality. To achieve the required mirror and grating quality, the metrology instrumentation and methods used to characterize these challenging optics and, even more so, optical assemblies must also offer exceptional functionality and performance. One of the most widely used slope measuring instruments for characterizing x-ray optics is the long trace profiler (LTP). The easily reconfigurable mechanical design of the LTP allows optimization of the profiler arrangement to the specifics of a particular metrology task. Here, we discuss the optical schematic, design, and performance of an original multifunctional light beam source that provides functional flexibility of the LTP optical sensor. With this source, the LTP can be easily reconfigured for measurements of x-ray mirrors or diffraction gratings that have widely different source coherence requirements. Usage of a source with a low degree of coherence for mirror metrology helps to suppress the LTP systematic errors due to spurious interference effects in the LTP optical elements. A high-coherence narrow-band source is used for groove-density-distribution characterization of x-ray diffraction gratings. The systematic error and spatial resolution of the LTP with the different sources is also measured and analyzed.

Yashchuk, Valeriy V.↗

Extraction of mechanical properties of materials through deep learning from instrumented indentation

Instrumented indentation has been developed and widely utilized as one of the most versatile and practical means of extracting mechanical properties of materials. This method is particularly desirable for those applications where it is difficult to experimentally determine the mechanical properties using stress–strain data obtained from coupon specimens. Such applications include material processing and manufacturing of small and large engineering components and structures involving the following: three dimensional (3D) printing, thin-film and multilayered structures, and integrated manufacturing of materials for coupled mechanical and functional properties. Here, we utilize the latest developments in neural networks, including a multifidelity approach whereby deep-learning algorithms are trained to extract elastoplastic properties of metals an d alloys from instrumented indentation results using multiple datasets for desired levels of improved accuracy. We have established algorithms for solving inverse problems by recourse to single, dual, and multiple indentation and demonstrate that these algorithms significantly outperform traditional brute force computations and function-fitting methods. Moreover, we present several multifidelity approaches specifically for solving the inverse indentation problem which 1) significantly reduce the number of high-fidelity datasets required to achieve a given level of accuracy, 2) utilize known physical and scaling laws to improve training efficiency and accuracy, and 3) integrate simulation and experimental data for training disparate datasets to learn and minimize systematic errors. The predictive capabilities and advantages of these multifidelity methods have been assessed by direct comparisons with experimental results for indentation for different commercial alloys, including two wrought aluminum alloys and several 3D printed titanium alloys.

3D printed materials, stress-strain behavior, mult↗

Quantification of manganese for ChemCam Mars and laboratory spectra using a multivariate model

In this work, we report a new calibration model for manganese using the laser-induced breakdown spectroscopy instrument that is part of the ChemCam instrument suite onboard the NASA Curiosity rover. The model has been trained using an expanded set of 523 manganese-bearing rock, mineral, metal ore, and synthetic standards. The optimal calibration model uses the Partial Least Squares (PLS) and Least Absolute Shrinkage and Selection Operator (LASSO) multivariate techniques, with a novel “double blending” technique. We determined the detection limit for manganese is 82 ppm using a method blank procedure and is possibly as low as 27 ppm based on visual inspection of the spectra. Based on a representative test set consisting of measurements on 93 standards, the double blended multivariate model shows a Root Mean Squared Error of Prediction (RMSEP) accuracy of 1.39 wt% MnO for the full blended model. Employing a local RMSEP estimate where the model performance is evaluated based on nearby test samples, the accuracy is 0.03 wt% at the quantification limit (0.05 wt% MnO), 0.4 wt% accuracy at 1.0 wt% MnO, and 4.4 wt% accuracy at 100 wt% MnO. Precision is estimated using the standard deviation of the test set measurements, and is ±0.01 wt% MnO at the quantification limit, ±0.09 wt% MnO at 1.0 wt% MnO, and ± 2.1 wt% MnO at 100 wt% MnO (all 1 standard deviation). This new calibration is important for understanding the variation of manganese in the bedrock with the Curiosity rover on Mars, which provides insight into past redox conditions on Mars.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Steering an intense relativistic electron beam in a linear induction accelerator

The best electron beam transport through a linear induction accelerator (LIA) is achieved when the beam is well centered on the magnetic axis of the focusing solenoids. Since the beam may be injected offset from, or at an angle to, the centerline, dipole magnets are usually provided as a means to steer the beam and center it. Steering may be accomplished by trial and error, but this is very time consuming, especially for accelerators with a low repetition rate for beam position measurements and dipole adjustments. With this in mind, this article presents a steering method requiring a minimal number of measurements and adjustments to position the beam at any desired location, including positioning on the centerline.

47 OTHER INSTRUMENTATION↗

Reducing Ground-based Astrometric Errors with Gaia and Gaussian Processes

Stochastic field distortions caused by atmospheric turbulence are a fundamental limitation to the astrometric accuracy of ground-based imaging. This distortion field is measurable at the locations of stars with accurate positions provided by the Gaia DR2 catalog; we develop the use of Gaussian process regression (GPR) to interpolate the distortion field to arbitrary locations in each exposure. We introduce an extension to standard GPR techniques that exploits the knowledge that the 2D distortion field is curl-free. Applied to several hundred 90 s exposures from the Dark Energy Survey as a test bed, we find that the GPR correction reduces the variance of the turbulent astrometric distortions ≈12× , on average, with better performance in denser regions of the Gaia catalog. The rms per-coordinate distortion in the riz bands is typically ≈7 mas before any correction and ≈2 mas after application of the GPR model. The GPR astrometric corrections are validated by the observation that their use reduces, from 10 to 5 mas rms, the residuals to an orbit fit to riz-band observations over 5 yr of the r = 18.5 trans-Neptunian object Eris. We also propose a GPR method, not yet implemented, for simultaneously estimating the turbulence fields and the 5D stellar solutions in a stack of overlapping exposures, which should yield further turbulence reductions in future deep surveys.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic Layer Thermopiles: Comprehensive static calibration, comparison and application in subsonic and supersonic flows

Here, this paper compares the calibration of different heat flux sensors in radiation- and convection-based sub- and supersonic operation. First, four heat flux sensors based on different principles: ALTP (Transverse Seebeck Effect), HFM-8E (differential-layer device), coaxial Thermocouple and a TG-2000 (circular-foil gage) are calibrated in a laser-based radiation setup. In a second step, all heat flux sensors are compared with a slug-calorimeter within a subsonic convection-dominated facility based on stagnation-point measurements of an impinging hot air jet. The obtained results indicate that a sensitivity transfer between a radiative calibrated sensor used in a mainly convective environment is not always possible and can lead to significant, systematic errors. Calibration in a subsonic shear flow with thermocouple readings demonstrate small divergence from the manufacturer provided sensitivity. Finally, supersonic testing with high frequency shock-boundary layer interactions highlight the need for ALTP rather than the conventional use of thermocouple arrays to resolve the high frequency phenomena associated with shock boundary layer interactions.

42 ENGINEERING↗

Controlling optical-cavity locking using reinforcement learning

Abstract This study applies an effective methodology based on Reinforcement Learning to a control system. Using the Pound–Drever–Hall locking scheme, we match the wavelength of a controlled laser to the length of a Fabry-Pérot cavity such that the cavity length is an exact integer multiple of the laser wavelength. Typically, long-term drift of the cavity length and laser wavelength exceeds the dynamic range of this control if only the laser’s piezoelectric transducer is actuated, so the same error signal also controls the temperature of the laser crystal. In this work, we instead implement this feedback control grounded on Q-Learning. Our system learns in real-time, eschewing reliance on historical data, and exhibits adaptability to system variations post-training. This adaptive quality ensures continuous updates to the learning agent. This innovative approach maintains lock for eight days on average.

47 OTHER INSTRUMENTATION↗

Evaluation and Intercomparison of Small Uncrewed Aircraft Systems Used for Atmospheric Research

Abstract Small uncrewed aircraft systems (sUAS) are regularly being used to conduct atmospheric research and are starting to be used as a data source for informing weather models through data assimilation. However, only a limited number of studies have been conducted to evaluate the performance of these systems and assess their ability to replicate measurements from more traditional sensors such as radiosondes and towers. In the current work, we use data collected in central Oklahoma over a 2-week period to offer insight into the performance of five different sUAS platforms and associated sensors in measuring key weather data. This includes data from three rotary-wing and two fixed-wing sUAS and included two commercially available systems and three university-developed research systems. Flight data were compared to regular radiosondes launched at the flight location, tower observations, and intercompared with data from other sUAS platforms. All platforms were shown to measure atmospheric state with reasonable accuracy, though there were some consistent biases detected for individual platforms. This information can be used to inform future studies using these platforms and is currently being used to provide estimated error covariances as required in support of assimilation of sUAS data into weather forecasting systems.

54 ENVIRONMENTAL SCIENCES↗

(U) A Theoretical Study of Asay Foil Trajectories (V.02)

We consider the trajectory of a generic Asay foil ejecta momentum diagnostic sensor, for scenarios where ejecta are produced at a planar surface and fly ballistically through a perfect vacuum to the sensor. To do so, we build upon a previously established mathematical formalism derived for the analytic study of stationary sensors (i.e., piezopins). First, we derive the momentum conservation equation for the problem, in a form amenable to accelerating sensors, in terms of a generic ejecta source areal mass function (“source model”). This defines an integro-differential equation (IDE) for the foil trajectory. When ejecta production is instantaneous - as is generally assumed in momentum diagnostic data analyses - the IDE leads to an implicit and easily calculable closed-form solution for the foil trajectory in a perfect system, as long as the ejecta particle velocity distribution is twice-integrable. General properties of the instant-production trajectory solution indicate the existence of a boundary condition the particle velocity distribution must satisfy in order for the analytically predicted foil trajectories to be compatible with certain features commonly observed in foil data. This boundary condition is identical to one derived previously from a consideration of piezopin data. Armed with the analytic solution for instant production, we also consider various techniques used to extract time-dependent cumulative ejecta masses from foil trajectories, and derive an expression for the error imposed by using an approximated equation of motion. This analytic trajectory solution furthermore makes it possible to examine the common practice of presenting inferred cumulative ejecta masses as a function of a normalized implied velocity; we derive conditions under which this methodology is and is not meaningful. We also propose a strategy for extending the instant-production trajectory solution to time-dependent source functions.

42 ENGINEERING↗

Measuring the Conditional Luminosity and Stellar Mass Functions of Galaxies by Combining the Dark Energy Spectroscopic Instrument Legacy Imaging Surveys Data Release 9, Survey Validation 3, and Year 1 Data

In this investigation, we leverage the combination of the Dark Energy Spectroscopic Instrument (DESI) Legacy Imaging Surveys Data Release 9, Survey Validation 3, and Year 1 data sets to estimate the conditional luminosity functions and conditional stellar mass functions (CLFs and CSMFs) of galaxies across various halo mass bins and redshift ranges. To support our analysis, we utilize a realistic DESI mock galaxy redshift survey (MGRS) generated from a high-resolution Jiutian simulation. An extended halo-based group finder is applied to both MGRS catalogs and DESI observation. By comparing the r- and z-band luminosity functions (LFs) and stellar mass functions (SMFs) derived using both photometric and spectroscopic data, we quantified the impact of photometric redshift (photo-z) errors on the galaxy LFs and SMFs, especially in the low-redshift bin at the low-luminosity/mass end. By conducting prior evaluations of the group finder using MGRS, we successfully obtain a set of CLF and CSMF measurements from observational data. We find that at low redshift, the faint-end slopes of CLFs and CSMFs below ~10 9 h –2 L ⊙ (or h –2 M ⊙ ) evince a compelling concordance with the subhalo mass functions. After correcting the cosmic variance effect of our local Universe following Chen et al., the faint-end slopes of the LFs/SMFs turn out to also be in good agreement with the slope of the halo mass function.

79 ASTRONOMY AND ASTROPHYSICS↗

Analyzing the Calibration History of Radiometers for Determining Optimal Calibration Day(s)

This study investigates the effects of calibrating radiometers using one day or multiple cloudless days as recommended by ASTM and ISO standards. The results demonstrate good responsivity agreement with estimated uncertainty error bars over the years for various radiometers under various Broadband Outdoor Radiometer Calibration (BORCAL) events at both the National Renewable Energy Laboratory and the Southern Great Plains facility. The BORCAL method appears to justify the use of a single calibration day with enough data points to attain repeatable calibration results.

BORCAL↗

The Reduction of Random Uncertainty in Differential Temperature Measurements Using Common Leg Thermocouples

The uncertainty quantification of random error is considered for common leg thermocouples (i.e., where one thermoelement is shared along the length of the TC for all other TC junctions present). The uncertainty is presented for both a common leg and individual, separate leg thermocouples. For Type K thermocouples a reduction in uncertainty by up to 3x is capable when differential temperatures, ?T, are within 150°C, and diminishes to little to no improvement above 150°C.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

The clustering of the SDSS-IV extended Baryon Oscillation Spectroscopic Survey quasar sample: testing observational systematics on the Baryon Acoustic Oscillation measurement

ABSTRACT Baryon Acoustic Oscillations (BAO) are considered to be a very robust standard ruler against various systematics. This premise has been tested against observational systematics, but not to the level required for the next generation of galaxy surveys such as the Dark Energy Spectroscopic Instrument (DESI) and Euclid. In this paper, we investigate the effect of observational systematics on the BAO measurement of the final sample of quasars from the extended Baryon Oscillation Spectroscopic Survey Data Release 16 in order to prepare and hone a similar analysis for upcoming surveys. We employ catalogues with various treatments of imaging systematic effects using linear and neural network-based non-linear approaches and consider how the BAO measurement changes. We also test how the variations to the BAO fitting model respond to the observational systematics. As expected, we confirm that the BAO measurements obtained from the DR16 quasar sample are robust against imaging systematics well within the statistical error, while reporting slightly modified constraints that shift the line-of-sight BAO signal by less than 1.1 per cent. We use realistic simulations with similar redshift and angular distributions as the DR16 sample to conduct statistical tests for validating the pipeline, quantifying the significance of differences, and estimating the expected bias on the BAO scale in future high-precision data sets. Although we find a marginal impact for the eBOSS QSO data, the work presented here is of vital importance for constraining the nature of dark energy with the BAO feature in the new era of big data cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

A unified realization of electrical quantities from the quantum International System of Units

In the revised International System of Units (SI), the ohm and the volt are realized from the von Klitzing constant and the Josephson constant, and a practical realization of the ampere is possible by applying Ohm’s law directly to the quantum Hall and Josephson effects. As a result, it is possible to create an instrument capable of realizing all three primary electrical units, but the development of such a system remains challenging. Here, in this study, we report a unified realization of the volt, ohm and ampere by integrating a quantum anomalous Hall resistor (QAHR) and a programmable Josephson voltage standard (PJVS) in a single cryostat. Our system has a quantum voltage output that ranges from 0.24 mV to 6.5 mV with combined relative uncertainties down to 3 μV V −1 . The QAHR provides a realization of the ohm at zero magnetic field with uncertainties near 1 μΩ Ω −1 . We use the QAHR to convert a longitudinal current to a quantized Hall voltage and then directly compare that against the PJVS to realize the ampere. We determine currents in the range of 9.33–252 nA, and our lowest uncertainty is 4.3 μA A −1 at 83.9 nA. For other current values, a systematic error that ranges from −10 μA A −1 to −30 μA A −1 is present due to the imperfect isolation of the PJVS microwave bias.

Quantum metrology↗

Spectral Data Fusion From Handheld Laser-Induced Breakdown Spectroscopy (LIBS) and X-ray Fluorescence (XRF) Analyzers for Improved Detection of Cerium in a Simulated Dispersal Accident

Here, this work implements a mid-level data fusion methodology on spectral data from handheld X-ray fluorescence and laser-induced breakdown spectroscopy analyzers to quantify plutonium surrogate (CeO 2 ) contamination in soil samples for the first time. Spectral data from each analyzer were used independently to train supervised machine learning regressions to predict Ce concentration. Fused features from both data sets were then used to train the same models, comparing prediction performance by evaluating model precision and sensitivity. Fusing principal component scores from the two sensors yielded an order of magnitude improvement in precision and sensitivity of predictions made with an artificial neural network, compared to predictions made by models trained on independent sensor data. As a result, a boosted ensemble trained on the fused spectral features yielded an ideal predictor with root-mean-squared error on the order of 10 –6 and calculated limit of detection order 10 –5 wt %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainties in Atomic Data for Modeling Astrophysical Charge Exchange Plasmas

Relevant uncertainties of theoretical atomic data are vital to determining the accuracy of plasma diagnostics in a number of areas, including, in particular, the astrophysical study. We present a new calculation of the uncertainties on the present theoretical ion-impact charge exchange atomic data and X-ray spectra, based on a set of comparisons with the existing laboratory data obtained in historical merged-beam, cold-target recoil-ion momentum spectroscopy, and electron beam ion traps experiments. The average systematic uncertainties are found to be 35–88% on the total cross sections, and 57–75% on the characteristic line ratios. The model deviation increases as the collision energy decreases. The errors on total cross sections further induce a significant uncertainty to the calculation of ionization balance for low-temperature collisional plasmas. Substantial improvements of the atomic database and dedicated laboratory measurements are needed to obtain the current models, ready for the X-ray spectra from the next X-ray spectroscopic mission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments for MSRs

This report serves as the deliverable for Milestone M3RS-23AN0401061 that is part of Work Package RS-23AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone was to determine performance of the flow enhanced electrochemical sensor (FEES) and modular flow instrumentation testbed (MFIT) in safeguards relevant scenarios. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. To further improve this capability, in FY23 we undertook a campaign of safeguards relevant scenarios in molten salt containing a range of uranium chloride concentrations (0 to 3 wt%). All the testing carried out in FY23 was aided by a control system designed to automatically actuate flow conditions and collect data. This new automation system is estimated to have increased experimental throughput by a factor of four and enabled testing in a variety of complex conditions. The advancements in throughput and repeatability led to improved quantification of actinide concentrations using the in-flow sensors, with a reduction of the mean absolute relative error from 5.6% in FY22 to 3.1% in FY23. In addition to safeguards scenarios run in the MFIT, FY23 work included deployment of a FEES at a partner institution where it will be tested in a flowing salt loop. The FEES was successfully integrated into that loop and is being tested prior to loop startup. In FY23, work also continued on the smaller flow system that we have named the mini-MFIT. This smaller system is capable of rapid prototyping of new sensor designs prior to installation in the larger MFIT radiological flow system. Work was carried out to test this new system in non-radiological molten salts in a separate glovebox. This work is helping us to enhance the accuracy of our salt monitoring capabilities through the integration of multiple types of sensors. The high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will be needed to further push the measurement accuracy to the needed level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗