Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ORIENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Collimation and tagging instrumentation for the GlueX Photon Beamline

A new high energy polarized photon source is being constructed for the GlueX experiment at Jefferson Lab. Linear polarization is obtained using coherent bremsstrahlung from an oriented diamond radiator. By collimating the photon beam to a fraction of the characteristic bremsstrahlung angle $m_e/E_0$, linear polarization of 40\% is obtained at a photon energy of 9~GeV, for an incident electron beam of 12~GeV. Active stabilization of the photon beam spot on the collimator face is required in order to establish and maintain the alignment of the beam on the collimator axis with the required degree of accuracy. A photon beam centroid monitor has been developed for this purpose, based on the design of an electron beam halo detector that was invented for use at SLAC 30 years ago. Beam tests of this device in Hall B at 6 GeV show that it has the required bandwidth and sensitivity to be used in an active feedback loop in the electron beam steering controls. Such a feedback circuit is capable of locking the Hall D photon beam on the Hall D collimator with the required accuracy for GlueX at frequencies up to 1~kHz, over a wide range in beam current.

Jones, Richard↗

Low-noise humidity controller for imaging water mediated processes in atomic force microscopy

We demonstrate the construction of a novel low-noise continuous flow humidity controller and its integration with a commercial variable-temperature atomic force microscope fluid cell, allowing precise control of humidity and temperature at the sample during nanoscale measurements. Based on wet and dry gas mixing, the design allows a high mechanical stability to be achieved by means of an ultrasonic atomiser for the generation of water-saturated gas, improving upon previous bubbler-based architectures. Water content in the flow is measured both at the inflow and outflow of the fluid cell, enabling the monitoring of water condensation and icing, and allowing controlled variation of the sample temperature independently of the humidity. To benchmark the performance of the controller, the results of detailed noise studies and time-based imaging of the formation of ice layers on highly oriented pyrolytic graphite are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CHANDRA DETECTION OF EXTENDED X-RAY EMISSION FROM THE RECURRENT NOVA RS OPHIUCHI

Radio, infrared, and optical observations of the 2006 eruption of the symbiotic recurrent nova RS Ophiuchi showed that the explosion produced non-spherical ejecta. Some of this ejected material was in the form of bipolar jets to the east and west of the central source. Here we describe X-ray observations taken with the Chandra X-ray Observatory one and a half years after the beginning of the outburst that reveal narrow, extended structure with a position angle of approximately 300 deg. (east of north). Although the orientation of the extended feature in the X-ray image is consistent with the readout direction of the CCD detector, extensive testing suggests that the feature is not an artifact. Assuming it is not an instrumental effect, the extended X-ray structure shows hot plasma stretching more than 1900 AU from the central binary (taking a distance of 1.6 kpc). The X-ray emission is elongated in the northwest direction-in line with the extended infrared emission and some minor features in the published radio image. It is less consistent with the orientation of the radio jets and the main bipolar optical structure. Most of the photons in the extended X-ray structure have energies of less than 0.8 keV. If the extended X-ray feature was produced when the nova explosion occurred, then its 1.''2 length as of 2007 August implies that it expanded at an average rate of more than 2 mas day{sup -1}, which corresponds to a flow speed of greater than 6000 km s{sup -1} (days/1.6 kpc) in the plane of the sky. This expansion rate is similar to the earliest measured expansion rates for the radio jets.

79 ASTRONOMY AND ASTROPHYSICS↗

Concept and simulation study of a novel localization method for robotic endoscopic capsules using multiple positron emission markers

Purpose: Over the last decade, wireless capsule endoscope has been the tool of choice for noninvasive inspection of the gastrointestinal tract, especially in the small intestine. However, the latest clinical products have not been equipped with a sufficiently accurate localization system which makes it difficult to determine the location of intestinal abnormalities, and to apply follow-up interventions such as biopsy or drug delivery. In this paper, the authors present a novel localization method based on tracking three positron emission markers embedded inside an endoscopic capsule. Methods: Three spherical {sup 22}Na markers with diameters of less than 1 mm are embedded in the cover of the capsule. Gamma ray detectors are arranged around a patient body to detect coincidence gamma rays emitted from the three markers. The position of each marker can then be estimated using the collected data by the authors’ tracking algorithm which consists of four consecutive steps: a method to remove corrupted data, an initialization method, a clustering method based on the Fuzzy C-means clustering algorithm, and a failure prediction method. Results: The tracking algorithm has been implemented inMATLAB utilizing simulation data generated from the Geant4 Application for Emission Tomography toolkit. The results show that this localization method can achieve real-time tracking with an average position error of less than 0.4 mm and an average orientation error of less than 2°. Conclusions: The authors conclude that this study has proven the feasibility and potential of the proposed technique in effectively determining the position and orientation of a robotic endoscopic capsule.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Report: Imaging of Buried Nanoscale Optically Active Materials

This is a final report covering work done at University of Maryland to develop a Ballistic Electron Emission Luminescence (BEEL) microscope. This technique was intended to examine the carrier transport and photon emission in deeply buried optically-active layers and thereby provide a means for materials science to unmask the detailed consequences of experimentally controllable growth parameters, such as quantum dot size, statistics and orientation, and defect density and charge recombination pathways.

36 MATERIALS SCIENCE↗

Bicep2. III. INSTRUMENTAL SYSTEMATICS

In a companion paper, we have reported a >5σ detection of degree scale B-mode polarization at 150 GHz by the Bicep2 experiment. Here we provide a detailed study of potential instrumental systematic contamination to that measurement. We focus extensively on spurious polarization that can potentially arise from beam imperfections. We present a heuristic classification of beam imperfections according to their symmetries and uniformities, and discuss how resulting contamination adds or cancels in maps that combine observations made at multiple orientations of the telescope about its boresight axis. We introduce a technique, which we call “deprojection,” for filtering the leading order beam-induced contamination from time-ordered data, and show that it reduces power in Bicep2's actual and null-test BB spectra consistent with predictions using high signal-to-noise beam shape measurements. We detail the simulation pipeline that we use to directly simulate instrumental systematics and the calibration data used as input to that pipeline. Finally, we present the constraints on BB contamination from individual sources of potential systematics. We find that systematics contribute BB power that is a factor of ∼10× below Bicep2's three-year statistical uncertainty, and negligible compared to the observed BB signal. The contribution to the best-fit tensor/scalar ratio is at a level equivalent to r = (3–6) × 10{sup −3}.

79 ASTRONOMY AND ASTROPHYSICS↗

Robotic System for Precision Assembly of NIF Ignition Targets

This paper provides an overview of the design and testing of a robotic system developed for assembling the inertial confinement fusion ignition targets (depicted in Figures 1 and 2) that will be fielded on the National Ignition Facility (NIF) laser [1]. The system, referred to as the Final Assembly Machine and shown in Figure 3, consists of six groups of stacked axes that allow manipulating millimeter-sized components with submicron precision, integrated with an optical coordinate measuring machine (OCMM) that provides in-situ metrology. Nineteen motorized axes and ten manual axes are used to control the position and orientation of five objects that are predominantly assembled together in a cubic centimeter work zone. An operator-in-the-loop provides top-level control of the system, making it more similar to a surgical robot than to a programmed computer-controlled machine tool. The operator is provided visual feedback by the vision system of the OCMM, and tactile feedback by force and torque sensors embedded in the tooling that holds the major components being assembled. The vision system is augmented with auxiliary mirrors providing multiple viewing directions, and is used to guide the approach and alignment of the components, and to measure the relative position and orientation of the components. The force and torque sensors are used to guide the final approach, alignment, and mating of the components that are designed to slip-fit together, and to monitor that mating while adhesively bonding those components and attaching the target base.

42 ENGINEERING↗

Small-Body Extensions for the Satellite Orbit Analysis Program (SOAP)

An extension to the SOAP software allows users to work with tri-axial ellipsoid-based representations of planetary bodies, primarily for working with small, natural satellites, asteroids, and comets. SOAP is a widely used tool for the visualization and analysis of space missions. The small body extension provides the same visualization and analysis constructs for use with small bodies. These constructs allow the user to characterize satellite path and instrument cover information for small bodies in both 3D display and numerical output formats. Tri-axial ellipsoids are geometric shapes the diameters of which are different in each of three principal x, y, and z dimensions. This construct provides a better approximation than using spheres or oblate spheroids (ellipsoids comprising two common equatorial diameters as a distinct polar diameter). However, the tri-axial ellipsoid is considerably more difficult to work with from a modeling perspective. In addition, the SOAP small-body extensions allow the user to actually employ a plate model for highly irregular surfaces. Both tri-axial ellipsoids and plate models can be assigned to coordinate frames, thus allowing for the modeling of arbitrary changes to body orientation. A variety of features have been extended to support tri-axial ellipsoids, including the computation and display of the spacecraft sub-orbital point, ground trace, instrument footprints, and swathes. Displays of 3D instrument volumes can be shown interacting with the ellipsoids. Longitude/latitude grids, contour plots, and texture maps can be displayed on the ellipsoids using a variety of projections. The distance along an arbitrary line of sight can be computed between the spacecraft and the ellipsoid, and the coordinates of that intersection can be plotted as a function of time. The small-body extension supports the same visual and analytical constructs that are supported for spheres and oblate spheroids in SOAP making the implementation of the more complex algorithms largely transparent to the user.

Carnright, Robert↗

Acoustic Emission Source Location in Unidirectional Carbon-Fibre-Reinforced Plastic Plates Using Virtually Trained Artificial Neural Networks

Acoustic emission source location in a unidirectional carbon-fibre-reinforced plastic plate was attempted employing Artificial Neural Network (ANN) technology. The acoustic emission events were produced by a lead break, and the response wave received by piezoelectric sensors, type VS150-M resonant at 150 kHz. The waves were detected by a Vallen AMSY4 eight-channel instrumentation. The time of arrival, determined through the conventional threshold crossing technique, was used to measure the dependence of wave velocity on fibre orientation. A simple empirical formula, relying on classical lamination and suggested by wave propagation theory, was able to accurately model the experimental trend. Based on the formula, virtual training and testing data sets were generated for the case of a plate monitored by three transducers, and adopted to select two potentially effective ANN architectures. For final validation, experimental tests were carried out, positioning the source at predetermined points evenly distributed within the plate area. A very satisfactory correlation was found between the actual source locations and the ANN predictions.

36 MATERIALS SCIENCE↗

Survey of ultraviolet shuttle glow

The University of Colorado Get Away Special (GAS) project utilizes the efforts of its students to place experiments on the shuttle. The objective of one experiment, the shuttle glow study, is to conduct a general survey of emissions in the ultraviolet near vehicle surfaces. An approximate wavelength range of 1900 to 3000 A will be scanned to observe predominant features. Special emphasis will be placed on studying the band structure of NO near 2000 A and the Mg+ line at 2800 A. The spectrometer, of Ebert-Faste 1/8-meter design, will perform the experiment during spacecraft night. It will be oriented such that the optical axis points to the cargo bay zenith. In order to direct the field-of-view of the instrument onto the shuttle vertical stabilizer (tail), a mirror assembly is employed. The mirror system has been designed to rotate through 7.5 degrees of arc using 10 positions resulting in a spatial resolution of 30 x 3 cm, with the larger dimension corresponding to the horizontal direction. Such a configuration can be attained from the forwardmost position in the cargo bay. Each spatial position will be subjected to a full spectral scan with a resolution on the order of 10 A.

Spear, K. A.↗

On Physical Interpretation of the In-Site Measurement of Earth Rotation by Ring Laser Gyrometers

Large ring laser gyrometers under development have demonstrated the capability of detecting minute ground motions and deformations on a wide range of timescales. The next challenge and goal is to measure the Earth's rotation variations to a precision that rivals that of the present space-geodesy techniques, thus providing an in-situ (and cost effective alternatives of Earth rotation measurement for geophysical research and geodetic applications. Aside from thermal and mechanical instabilities, "undesirable" ground motion and tilt that appear in the signal will need to be removed before any variation in Earth rotation can be detected. Removal of these signals, some of them are larger than the sought rotation signals, has been a typical procedure in many precise geophysical instruments, such as gravimeters, seismometers, and tiltmeters. The remaining Earth rotation signal resides in both the spin around the axis and in the orientation of the axis. In the case of the latter, the in-situ measurement is complementary to the space-geodetic observables in terms of polar motion and nutation, a fact to be exploited.

Chao, B. F.↗

Multistage Passive Cooler for Spaceborne Instruments

A document describes a three-stage passive radiative cooler for a cryogenic spectrometer to be launched into a low orbit around the Moon. This cooler is relatively lightweight and compact, and its basic design is scalable and otherwise adaptable to other applications in which there are requirements for cooling instrumentation in orbit about planets. The cooler includes multiple lightweight flat radiator blades alternating with cylindrical parabolic infrared reflectors. The radiator blades are oriented at an angle chosen to prevent infrared loading from the Moon limb at the intended orbital altitude and attitude. The reflectors are shaped and oriented to position their foci outside the radiator surfaces. There are six radiator-blade/reflector pairs - two pairs for each stage of cooling. The radiator blades and reflectors are coated on their front and back surfaces with materials having various infrared emissivities, infrared reflectivities, and solar reflectivities so as to maximize infrared radiation to cold outer space and minimize inadvertent solar heating. The radiator blades and reflectors are held in place by a lightweight support structure, the components of which are designed to satisfy a complex combination of thermal and mechanical requirements.

Rodriquez, Jose I.↗

Techniques for Achieving Zero Stress in Thin Films of Iridium, Chromium, and Nickel

We examine techniques for achieving zero intrinsic stress in thin films of iridium, chromium, and nickel deposited by magnetron sputter deposition. The intrinsic stress is further correlated to the microstructural features and physical properties such as surface roughness and optical density at a scale appropriate to soft X-ray wavelengths. The examination of the stress in these materials is motivated by efforts to advance the optical performance of light-weight X-ray space telescopes into the regime of sub-arcsecond resolution through various deposition techniques that rely on control of the film stress to values within 10-100 MPa. A characteristic feature of the intrinsic stress behavior in chromium and nickel is their sensitivity to the magnitude and sign of the intrinsic stress with argon gas pressure and deposition rate, including the existence of a critical argon process pressure that results in zero film stress which scales linearly with the atomic mass of the sputtered species. While the effect of stress reversal with argon pressure has been previously reported by Hoffman and others for nickel and chromium, we report this effect for iridium. In addition to stress reversal, we identify zero stress in the optical functioning iridium layer shortly after island coalescence for low process pressures at a film thickness of approximately 35nm. The measurement of the low values of stress during deposition was achieved with the aid of a sensitive in-situ instrument capable of a minimum detectable level of stress, assuming a 35nm thick film, in the range of 0.40-6.0 MPa for <111> oriented crystalline silicon substrate thicknesses of 70-280 microns, respectively.

X-ray optical thin films↗

Scientist-Guided Autonomy for Self-Reliant Rovers

Although Mars rover missions have been highly successful in accomplishing scientific objectives, mission productivity is limited by challenges stemming from the need for commanding ground-based targeted observations under communication constraints imposed by the large distance between Earth and Mars. With an aging fleet of sun-synchronous relay orbiters, the opportunities for regular communication with rovers may become even more limited. In addition to on-board planning, robust navigation, and health assessment, there are strategies to make future rovers more self-reliant by enabling them to perform autonomous scientific characterizations of new areas during periods without an opportunity for ground-based targeted observations. In particular, we have studied how a ”walkabout” strategy, in which an initial high-level characterization of a region is used to informed subsequent passes with specific targeted observations, was used successfully during the investigation of Pahrump Hills by the Mars Science Laboratory. Inspired by this approach, we have identified several capabilities that could allow a rover to autonomously perform some of these initial high-level characterization steps. In this paper, we describe technologies for identifying specific geologic units, regions, or features of interest, identifying areas of contact between two adjacent units, detecting and determining the orientation of layering within rock units, identifying novel and interesting features, and planning observations of regions with different sampling strategies using remote sensing instruments. The observations acquired with these approaches are driven by scientists’ guidance and can provide scientists with data to help inform their decisions about where to make more resource-intensive targeted observations.

Doran, Gary↗

Interactive automated Bragg peak identification with 3D neutron scattering data

Neutron scattering experiments have undergone significant technological development through large area detectors with concurrent enhancements in neutron transport and electronic functionality. Data collected for neutron events include detector pixel location in 3D, time and associated metadata, such as, sample orientation, neutron wavelength, and environmental conditions. RadiaSoft and Oak Ridge National Laboratory personnel are considering single-crystal diffraction data from the TOPAZ instrument. We are leveraging a new method for rapid, interactive analysis of neutron data using NVIDIA’s IndeX 3D volumetric visualization framework. We have implemented machine learning techniques to automatically identify Bragg peaks and separate them from diffuse backgrounds and analyze the crystalline lattice parameters for further analysis. The implementation of automatic peak identification into IndeX allows scientists to visualize and analyze data in real-time. Our methods include a robust comparison with current analysis techniques which show improvement in a variety of aspects. These improvements will be incorporated into IndeX for visualization to allow scientists an interactive tool for crystal analysis.

Kilpatrick, Matthew↗

Drop Testing of a Container for the Storage, Transport and Disposal of Intermediate Level Waste - 18078

Impact tests were performed, as part of a corresponding container's substantiation, during design development of a shielded container proposed for use at Sellafield for waste retrieval from the First Generation Magnox Storage Pond (FGMSP) in the UK. The mechanical test program comprised a 9 m free drop test onto an unyielding target in a container long lid edge down orientation at ambient conditions. Further, a 0,5 m free drop test onto a punch target was performed. Here, the container was orientated with the lid downwards in a way that the punch, a mild steel bar, impacts a filter lid. The test specimen was instrumented with strain gauges and accelerometers for the drop tests. Transient strains at selected points of the inner and outer container walls, at the shielding lid, as well as at the lid bolts were measured during the container's impact. Furthermore, decelerations of the container body, container lid, and the skip were measured. The complex geometrical changes of the container due to impact were determined by optical 3d- deformation measures using the projected fringes method in combination with multi-image photogrammetry. This paper summarizes the performance of the drop tests and various drop test results in context with the design development as well as aspects regarding the associated Finite Element (FE) analyses and post-test evaluation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proof-of-Concept for Sensor Modeling in MOOSE for the Design of Autonomous Nuclear Reactor Control

Autonomous operation is essential for the deployment of microreactors and fission batteries, both in terrestrial and space applications. However, prototypes of microreactors and fission batteries do not exist yet, and even the design space has not been narrowed down conclusively, making the instrumentation and control system design difficult. For this reason, there is a need for flexible computational capabilities to create a numerical stand-in of potential microreactor and fission battery designs. The latter can be used to design and test control strategies to support autonomous operations. In this paper, we describe the initial implementation of a pluggable sensor system for the easy implementation of realistic sensor models in the multiphysics object-oriented simulation environment (MOOSE) framework. This new capability will enable MOOSE users to create a numerical stand-in of microreactors and fission batteries, ultimately allowing them to easily test new control algorithms, and instrumentation strategies for advanced systems in the design phase

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Proof-of-Concept for Sensor Modeling in MOOSE for the Design of Autonomous Nuclear Reactor Control

Autonomous operation is essential for the deployment of microreactors and fission batteries, both in terrestrial and space applications. For this reason, recent studies have investigated autonomous control by using adaptive model predictive control and multi-objective optimization for heat pipe–cooled microreactors under normal and heat pipe failure conditions. However, prototypes of microreactors and fission batteries do not exist yet, and even the design space has not been narrowed down conclusively, making the instrumentation and control system design difficult. For this reason, there is a need for flexible computational capabilities to create a numerical stand-in of potential microreactor and fission battery designs. The latter can be used to design and test control strategies to support autonomous operations. In this poster, we describe the initial implementation of a pluggable sensor system for the easy implementation of realistic sensor models in the multiphysics object-oriented simulation environment (MOOSE) framework. This new capability will enable MOOSE users to create a numerical stand-in of microreactors and fission batteries, ultimately allowing them to easily test new control algorithms, and instrumentation strategies for advanced systems in the design phase.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗