At least 415 records · Page 23

Automatic detection of microlensing events in the galactic bulge using machine learning techniques

The Wide Field Infrared Survey Telescope (WFIRST) is a NASA flagship mission scheduled to launch in mid-2020, with more than one year of its lifetime dedicated to microlensing survey. The survey is to discover thousands of exoplanets near or beyond the snowline via their microlensing light curve signatures, enabling a Kepler-like statistical analysis of planets at ~1-10 AU from their host stars and potentially revolutionizing our understanding of planet formation. The goal of our work is to create an automated system that has the ability to efficiently process and classify large-scale astronomical datasets that missions such as WFIRST will produce. In this paper, we discuss our framework that utilizes features election and parameter optimization for classification models to automatically differentiate the different types of stellar variability and detect microlensing events.

Shvartzvald, Yossi↗

IR-Live: fabrication of a low-cost plastic microfluidic device for infrared spectromicroscopy of living cells

Water is a strong mid-infrared absorber, which has hindered the full exploitation of label-free and non-invasive infrared (IR) spectromicroscopy techniques for the study of living biological samples. To overcome this barrier, many researchers have built sophisticated fluidic chambers or microfluidic chips wherein the depth of the liquid medium in the sample compartment is limited to 10 μm or less. We report an innovative and simple way to fabricate plastic devices with infrared transparent view-ports enabling infrared spectromicroscopy of living biological samples; therefore the device is named “IR-Live”. Advantages of this approach include lower production costs, a minimal need to access a micro-fabrication facility, and unlimited mass or waste exchange for the living samples surrounding the view-port area. We demonstrate that the low-cost IR-Live in combination with microfluidic perfusion techniques enables long term (>60 h) cell culture, which broadens the capability of IR spectromicroscopy for studying living biological samples. To illustrate this, we first applied the device to study protein and lipid polarity in migrating REF52 fibroblasts by collecting 2-dimensional spectral chemical maps at a micrometer spatial resolution. Then, we demonstrated the suitability of our approach to study dynamic cellular events by collecting a time series of spectral maps of U937 monocytes during the early stage of cell attachment to a bio-compatible surface.

47 OTHER INSTRUMENTATION↗

Spectroscopic Monitoring of Spent Nuclear Fuel Reprocessing Streams: An Evaluation of Spent Fuel Solutions via Raman, Visible, and Near-Infrared Spectroscopy

The potential of using optical spectroscopic techniques, such as Raman and Visible/Near Infrared (Vis/NIR), for on-line process control and special nuclear materials accountability applications at a spent nuclear fuel reprocessing facility was evaluated. Availability of on-line real-time techniques that directly measure process concentrations of nuclear materials will enhance performance and proliferation resistance of the solvent extraction processes. Further, on-line monitoring of radiochemical streams will also improve reprocessing plant operation and safety. This report reviews current state of development of the spectroscopic on-line monitoring techniques for such solutions. To further examine applicability of optical spectroscopy for monitoring reprocessing solutions, segments of a spent nuclear fuel, with approximate burn-up values of 70 MWd/kgM, were dissolved in concentrated nitric acid and adjusted to varying final concentrations of HNO3. The resulting spent fuel solutions were batch-contacted with tributyl phosphate/dodecane organic solvent. The feed and equilibrium aqueous and loaded organic solutions were subjected to optical measurements. The obtained spectra showed the presence of the quantifiable Raman bands due to NO3- and UO22+ and Vis/NIR bands due to multiple species of Pu(IV), Pu(VI), Np(V), the Np(V)-U(VI) cation-cation complex, and Nd(III) in fuel solutions, justifying spectroscopic techniques as a promising methodology for monitoring spent fuel processing solutions in real-time. Quantitative evaluation of the fuel solution was performed based on spectroscopic measurements and compared to ICP-MS analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A COMPARISON OF SPECTROSCOPIC VERSUS IMAGING TECHNIQUES FOR DETECTING CLOSE COMPANIONS TO KEPLER OBJECTS OF INTEREST

Kepler planet candidates require both spectroscopic and imaging follow-up observations to rule out false positives and detect blended stars. Traditionally, spectroscopy and high-resolution imaging have probed different host star companion parameter spaces, the former detecting tight binaries and the latter detecting wider bound companions as well as chance background stars. In this paper, we examine a sample of 11 Kepler host stars with companions detected by two techniques—near-infrared adaptive optics and/or optical speckle interferometry imaging, and a new spectroscopic deblending method. We compare the companion effective temperatures (T{sub eff}) and flux ratios (F{sub B}/F{sub A}, where A is the primary and B is the companion) derived from each technique and find no cases where both companion parameters agree within 1σ errors. In 3/11 cases the companion T{sub eff} values agree within 1σ errors, and in 2/11 cases the companion F{sub B}/F{sub A} values agree within 1σ errors. Examining each Kepler system individually considering multiple avenues (isochrone mapping, contrast curves, probability of being bound), we suggest two cases for which the techniques most likely agree in their companion detections (detect the same companion star). Overall, our results support the advantage that the spectroscopic deblending technique has for finding very close-in companions (θ ≲ 0.″02–0.″05) that are not easily detectable with imaging. However, we also specifically show how high-contrast AO and speckle imaging observations detect companions at larger separations (θ ≥ 0.″02–0.″05) that are missed by the spectroscopic technique, provide additional information for characterizing the companion and its potential contamination (e.g., position angle, separation, magnitude differences), and cover a wider range of primary star effective temperatures. The investigation presented here illustrates the utility of combining the two techniques to reveal higher-order multiples in known planet-hosting systems.

79 ASTRONOMY AND ASTROPHYSICS↗

In-flight off-surface flow visualization using infrared imaging

A light test investigation was conducted to evaluate an infrared (IR) imaging technique to visualize off-surface flow phenomena. A single-engine, general-aviation airplane was equipped with an IR imaging system that viewed the region around the left wingtip. Vortical flow at the wingtip was seeded with surfur hexafluoride, a gas with strong infrared absorbing and emitting characteristics. Different terrain and sky backgrounds were evaluated for their effect on IR images of vortical flow. The best IR images were obtained with a clear background. The results of the investigation indicate that IR flow visualization compliments existing smoke generator methods for off-surface flow visualization.

Manuel, Gregory S.↗

Finite Volume Numerical Methods for Aeroheating Rate Calculations from Infrared Thermographic Data

The use of multi-dimensional finite volume numerical techniques with finite thickness models for calculating aeroheating rates from measured global surface temperatures on hypersonic wind tunnel models was investigated. Both direct and inverse finite volume techniques were investigated and compared with the one-dimensional semi -infinite technique. Global transient surface temperatures were measured using an infrared thermographic technique on a 0.333-scale model of the Hyper-X forebody in the Langley Research Center 20-Inch Mach 6 Air tunnel. In these tests the effectiveness of vortices generated via gas injection for initiating hypersonic transition on the Hyper-X forebody were investigated. An array of streamwise orientated heating striations were generated and visualized downstream of the gas injection sites. In regions without significant spatial temperature gradients, one-dimensional techniques provided accurate aeroheating rates. In regions with sharp temperature gradients due to the striation patterns two-dimensional heat transfer techniques were necessary to obtain accurate heating rates. The use of the one-dimensional technique resulted in differences of 20% in the calculated heating rates because it did not account for lateral heat conduction in the model.

Daryabeigi, Kamran↗

The effect of 150μm expandable graphite on char expansion of intumescent fire retardant coating

Intumescent is defined as the swelling of certain substances to insulate the underlying substrate when they are heated. In this research work the effect of 150μm expandable graphite (EG) was studied on char expansion, char morphology and char composition of intumescent coating formulations (ICFs). To study the expansion and thermal properties of the coating, nine different formulations were prepared. The coatings were tested at 500 °C for one hour and physically were found very stable and well bound with the steel substrate. The morphology was studied by Scanning Electron Microscopy (SEM). The char composition was analysed by X-ray Diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) techniques. EG above than 10.8wt% expands the char abruptly with uniform network structure and affect the outer surface of the char.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Near-infrared spectroscopy for monitoring of tissue oxygenation of exercising skeletal muscle in a chronic compartment syndrome model

Variations in the levels of muscle hemoglobin and of myoglobin oxygen saturation can be detected non-invasively with near-infrared spectroscopy. This technique could be applied to the diagnosis of chronic compartment syndrome, in which invasive testing has shown increased intramuscular pressure associated with ischemia and pain during exercise. We simulated chronic compartment syndrome in ten healthy subjects (seven men and three women) by applying external compression, through a wide inflatable cuff, to increase the intramuscular pressure in the anterior compartment of the leg. The tissue oxygenation of the tibialis anterior muscle was measured with near-infrared spectroscopy during gradual inflation of the cuff to a pressure of forty millimeters of mercury (5.33 kilopascals) during fourteen minutes of cyclic isokinetic dorsiflexion and plantar flexion of the ankle. The subjects exercised with and without external compression. The data on tissue oxygenation for each subject then were normalized to a scale of 100 per cent (the baseline value, or the value at rest) to 0 per cent (the physiological minimum, or the level of oxygenation achieved by exercise to exhaustion during arterial occlusion of the lower extremity). With external compression, tissue oxygenation declined at a rate of 1.4 +/- 0.3 per cent per minute (mean and standard error) during exercise. After an initial decrease at the onset, tissue oxygenation did not decline during exercise without compression. The recovery of tissue oxygenation after exercise was twice as slow with compression (2.5 +/- 0.6 minutes) than it was without the use of compression (1.3 +/- 0.2 minutes).

NASA Discipline Musculoskeletal↗

Finite Volume Numerical Methods for Aeroheating Rate Calculations from Infrared Thermographic Data

The use of multi-dimensional finite volume heat conduction techniques for calculating aeroheating rates from measured global surface temperatures on hypersonic wind tunnel models was investigated. Both direct and inverse finite volume techniques were investigated and compared with the standard one-dimensional semi-infinite technique. Global transient surface temperatures were measured using an infrared thermographic technique on a 0.333-scale model of the Hyper-X forebody in the NASA Langley Research Center 20-Inch Mach 6 Air tunnel. In these tests the effectiveness of vortices generated via gas injection for initiating hypersonic transition on the Hyper-X forebody was investigated. An array of streamwise-orientated heating striations was generated and visualized downstream of the gas injection sites. In regions without significant spatial temperature gradients, one-dimensional techniques provided accurate aeroheating rates. In regions with sharp temperature gradients caused by striation patterns multi-dimensional heat transfer techniques were necessary to obtain more accurate heating rates. The use of the one-dimensional technique resulted in differences of 20% in the calculated heating rates compared to 2-D analysis because it did not account for lateral heat conduction in the model.

Daryabeigi, Kamran↗

Applications of Advanced Nondestructive Evaluation (NDE) and Structural Health Monitoring (SHM) Techniques to Address Safety of Flight Issues on NASA Spacecraft

Advanced NDE and SHM techniques are critical for ensuring the reliability and safety of NASA launch vehicles and spacecraft. NDE techniques such as infrared thermography, THz imaging, x-ray computed tomography and backscatter x-ray are used to detect indications of damage in spacecraft components and structures. Additionally, sensor and measurement systems are integrated into spacecraft to provide SHM to detect damaging events that occur during flight such as debris impacts during launch and assent or from micrometeoroid and orbital debris, or excessive loading due to anomalous flight conditions. A number of examples will be provided of how these NDE and SHM techniques have been applied to resolve safety critical inspection concerns for the Space Shuttle, International Space Station (ISS), and a variety of launch vehicles and unmanned spacecraft.

Advanced Nondestructive Evaluation (NDE)↗

Applications of Advanced Nondestructive Measurement Techniques to Address Safety of Flight Issues on NASA Spacecraft

Advanced nondestructive measurement techniques are critical for ensuring the reliability and safety of NASA spacecraft. Techniques such as infrared thermography, THz imaging, X-ray computed tomography and backscatter X-ray are used to detect indications of damage in spacecraft components and structures. Additionally, sensor and measurement systems are integrated into spacecraft to provide structural health monitoring to detect damaging events that occur during flight such as debris impacts during launch and assent or from micrometeoroid and orbital debris, or excessive loading due to anomalous flight conditions. A number of examples will be provided of how these nondestructive measurement techniques have been applied to resolve safety critical inspection concerns for the Space Shuttle, International Space Station (ISS), and a variety of launch vehicles and unmanned spacecraft.

Prosser, Bill↗

Scanless laser waveform measurement in the near-infrared

Field-resolved measurements of few-cycle laser waveforms allow access to ultrafast electron dynamics in light–matter interactions and are key to future lightwave electronics. Recently, sub-cycle gating based on nonlinear excitation in active pixel sensors has allowed the first single-shot measurements of mid-infrared optical fields. Extending the techniques to shorter wavelengths, however, is not feasible using silicon-based detectors with bandgaps in the near-infrared. Here, we demonstrate an all-optical sampling technique for near-infrared laser fields, wherein an intense fundamental field generates a sub-cycle gate through nonlinear excitation of a wide-bandgap crystal, in this case, ZnO, which can sample the electric field of a weak perturbing pulse. By using a crossed-beam geometry, the temporal evolution of the perturbing field is mapped onto a transverse spatial axis of the nonlinear medium, and the waveform is captured in a single measurement of the spatially resolved fluorescence emission from the crystal. The technique is demonstrated through field-resolved measurements of the field reshaping during nonlinear propagation in the ZnO detection crystal.

Truong, Tran-Chau (ORCID:0000000348940635)↗

Measurements of the linewidth enhancement factor of mid-infrared quantum cascade lasers by different optical feedback techniques

Precise knowledge of the linewidth enhancement factor of a semiconductor laser under actual operating conditions is of prime importance since this parameter dictates various phenomena such as linewidth broadening or optical nonlinearities enhancement. The above-threshold linewidth enhancement factor of a mid-infrared quantum cascade laser structure operated at 10{sup ∘}C is determined experimentally using two different methods based on optical feedback. Both Fabry-Perot and distributed feedback quantum cascade lasers based on the same active area design are studied, the former by following the wavelength shift as a function of the feedback strength and the latter by self-mixing interferometry. The results are consistent and unveil a clear pump current dependence of the linewidth enhancement factor, with values ranging from 0.8 to about 3.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

VISSTPX2DRECTG16V4MINNIS (c1)

Satellite-based retrievals of cloud and radiation properties are available in this value-added product provided by Bill Smith’s group at NASA/Langley using the VISST (Visible Infrared Solar-Infrared Split Window Technique) algorithm. This product contains VISST-derived pixel-level products from the GOES-16 satellite, rectilinear projection 2-D array.

broadband LW flux↗

Non-invasive neuroimaging using near-infrared light

This article reviews diffuse optical brain imaging, a technique that employs near-infrared light to non-invasively probe the brain for changes in parameters relating to brain function. We describe the general methodology, including types of measurements and instrumentation (including the tradeoffs inherent in the various instrument components), and the basic theory required to interpret the recorded data. A brief review of diffuse optical applications is included, with an emphasis on research that has been done with psychiatric populations. Finally, we discuss some practical issues and limitations that are relevant when conducting diffuse optical experiments. We find that, while diffuse optics can provide substantial advantages to the psychiatric researcher relative to the alternative brain imaging methods, the method remains substantially underutilized in this field.

Non-NASA Center↗