Search NASA⌕ Search

SEARCH · Search NASA

Results for “Interface Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Relative role of motion and PSF compensation in whole-body oncologic PET-MR imaging

Purpose: Respiratory motion and partial-volume effects are the two main sources of image degradation in whole-body PET imaging. Simultaneous PET-MR allows measurement of respiratory motion using MRI while collecting PET events. Improved PET images may be obtained by modeling respiratory motion and point spread function (PSF) within the PET iterative reconstruction process. In this study, the authors assessed the relative impact of PSF modeling and MR-based respiratory motion correction in phantoms and patient studies using a whole-body PET-MR scanner. Methods: An asymmetric exponential PSF model accounting for radially varying and axial detector blurring effects was obtained from point source acquisitions performed in the PET-MR scanner. A dedicated MRI acquisition protocol using single-slice steady state free-precession MR acquisitions interleaved with pencil-beam navigator echoes was developed to track respiratory motion during PET-MR studies. An iterative ordinary Poisson fully 3D OSEM PET reconstruction algorithm modeling all the physical effects of the acquisition (attenuation, scatters, random events, detectors efficiencies, PSF), as well as MR-based nonrigid respiratory deformations of tissues (in both emission and attenuation maps) was developed. Phantom and{sup 18}F-FDG PET-MR patient studies were performed to evaluate the proposed quantitative PET-MR methods. Results: The phantom experiment results showed that PSF modeling significantly improved contrast recovery while limiting noise propagation in the reconstruction process. In patients with soft-tissue static lesions, PSF modeling improved lesion contrast by 19.7%–109%, enhancing the detectability and assessment of small tumor foci. In a patient study with small moving hepatic lesions, the proposed reconstruction technique improved lesion contrast by 54.4%–98.1% and reduced apparent lesion size by 21.8%–34.2%. Improvements were particularly important for the smallest lesion undergoing large motion at the lung-liver interface. Heterogeneous tumor structures delineation was substantially improved. Enhancements offered by PSF modeling were more important when correcting for motion at the same time. Conclusions: The results suggest that the proposed quantitative PET-MR methods can significantly enhance the performance of tumor diagnosis and staging as compared to conventional methods. This approach may enable utilization of the full potential of the scanner in oncologic studies of both the lower abdomen, with moving lesions, as well as other parts of the body unaffected by motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Science-based design of stable quantum dots for energy-efficient lighting

II-VI quantum dots, such as CdSe and CdTe, are attractive as downconversion materials for solid-state lighting, because of their narrow linewidth, tunable emission. However, for these materials to have acceptable quantum yields (QYs) requires that they be coated with a II-VI shell material whose valence band offset serves to confine the hole to the core. Confinement prevents the hole from accessing surface traps that lead to nonradiative decay of the exciton. Examples of such hole-confined core/shell QDs include CdTe/CdSe and CdSe/CdS. Unfortunately, the shell can also cause problems due to lattice mismatch, which ranges from 4-6% for systems of interest. This lattice mismatch can create significant interface energies at the heterojunction and places the core under radial compression and the shell under tangential tension. At elevated temperatures (~240°C) interfacial diffusion can relax these stresses, as can surface reconstruction, which can expose the core, creating hole traps. But such high temperatures favor the hexagonal Wurtzite structure, which has lower QY than the cubic zinc blende structure, which can be synthesized at lower temperatures, ~140°C. In the absence of alloying the core/shell structure can become metastable, or even unstable, if the shell is too thick. This can cause result in an irregular shell or even island growth. But if the shell is too thin thermallyactivated transport of the hole to surface traps can occur. In our LDRD we have developed a fundamental atomistic modeling capability, based on Stillinger-Weber and Bond-Order potentials we developed for the entire II-VI class. These pseudo-potentials have enabled us to conduct large-scale atomistic simulations that have led to the computation of phase diagrams of II-VI QDs. These phase diagrams demonstrate that at elevated temperatures the zinc blende phase of CdTe with CdSe grown on it epitaxially becomes thermodynamically unstable due to alloying. This is accompanied by a loss of hole confinement and a severe drop in the QY and emission lifetime, which is confirmed experimentally for the zinc blende core/shell QDs prepared at low temperatures. These QDs have QYs as high as 95%, which makes them very attractive for lighting. Finally, to address strain relaxation in these materials we developed a model for misfit dislocation formation that we have validated through atomistic simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metallic surface states in elemental electrides

Recent high-pressure studies have uncovered an alternative class of materials, insulating electride phases created by compression of simple metals. These exotic insulating phases develop an unusual electronic structure: the valence electrons move away from the nuclei and condense at interstitial sites, thereby acquiring the role of atomic anions or even molecules. In this work, we show that they are also topological phases as they exhibit a wide diversity of metallic surface states (SSs) that are controlled by the bulk electronic structure. The electronic reconstruction occurs that involves charge transfer between the surfaces of opposite polarity making both of them metallic, resembling the appearance of the two-dimensional gas at the renowned SrTiO 3 /LaAlO 3 interface. Remarkably, these materials thus embody seemingly disparate physical concepts—chemical electron localization, topological control of bulk-surface conductivity, and the two-dimensional electron gas. Such metallic SSs could be probed by direct electrical resistance or by standard photoemission measurements on recovery to ambient conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Substrate damage and incorporation of sapphire into barium hexaferrite films deposited by aerosol deposition

Barium Hexaferrite (BaM) grown on sapphire substrate by aerosol deposition is investigated in a subtractive wedge series to determine the extent of energetic substrate damage and indentation. Energy dispersive x-ray spectroscopy (EDS) mapping reveals Al 2 O 3 particulates ejected from the substrate surface during growth. The concentration of particles is higher at the substrate-film interface but persists throughout the 6 mu m thick film. An estimate of the indentation depth (similar to 600 nm) was agreed upon using two EDS techniques (line scan analysis and substrate surface reconstruction by areal integration). X-ray diffraction patterns show peak polycrystalline Al 2 O 3 intensity in 1.5 mu m thick wedges and a decrease at higher thicknesses, confirming that Al 2 O 3 particulate density decreases further from the substrate. Here, magnetic characterization showed decreased magnetic moment compared to bulk and thickness dependence consistent with the fractional increase of Al 2 O 3 content in the films. X-ray absorption at the Fe L 3 edge suggests a reduction of material close to the surface, but this reduction appears secondary in magnitude to the effect of damage from deposition.

36 MATERIALS SCIENCE↗

Dimensionality Reduction Library v 0.2

Dimensionality Reduction Library is a C++ library for dimensionality reduction. In the context of this library, dimensionality reduction is considered to consist of 1)estimation of the intrinsic dimensionality using sampled data, 2) Finding maps that reduce the dimensionality of data (forward map) or increase the dimensionality of data (reverse map) and 3) mapping arbitray coordinates to high and low dimensionalities. The library is intended to provide a consistent interface to multiple dimensionality reduction algorithms with an efficient C++ interface that runs efficiently on multicore architectures. A few routines have been optimized with an option for GPU acceleration or distributed computation. Currently the library offers intrinsic dimensionality estimation using point-PCA reconstruction error and/ residual variance. The following dimensionality reduction methods have been implemented: Principal Component Analysis Multidimensional Scaling Locally Linear Embedding IsoMap Autoencoder Neutral Networks An executable is also supplied that can be built to allow for command-line access to the library routines. A description for an application of the library for molecular structure analysis has been published.

BROWN, WILLIAM↗

InSight Entry, Descent and Landing Post-Flight Performance Assessment

On November 26, 2018, the Interior Exploration using Seismic Investigations, Geodesy and Heat Transport (InSight) lander successfully touched down on the surface of Mars. NASA Langley Research Center’s (LaRC) Program to Optimize Simulated Trajectories II (POST2) was used during both project development and flight operations to assess the Entry, Descent and Landing (EDL) vehicle performance against related requirements across the expected range of possible environmental and spacecraft conditions. During flight operations, these analyses were used to evaluate the need for updating flight software EDL parameters and the effects of executing a trajectory correction maneuver (TCM). Therefore, the NASA LaRC POST2 simulation had a critical role during the cruise, approach and ultimately EDL phases of the mission. This paper presents results of the final pre- and post- EDL flight performance assessments. A summary of the reconstructed “as-flown” trajectory with a comparison of key EDL metrics to the nominal and three-sigma bound pre-EDL predictions is also provided. Emphasis on the trajectory between entry interface and parachute deploy is provided as this is the period during which deviations from the pre-EDL prediction occurred. The post-flight assessment provides important verification of the POST2 models and analysis techniques used for InSight, providing critical feed-forward information to future lander missions.

Robert W Maddock↗

OSIRIS-REx Earth Return Orbit Determination Analysis and Performance

Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) was a NASA New Frontiers–class asteroid sample return mission to (101955) Bennu. OSIRIS-REx performed a series of Trajectory Cor-rection Maneuver (TCM)s to target an Entry Interface (EI) point for Earth Return and entry, descent, and landing (EDL). On September 24, 2023, the Sample Re-turn Capsule (SRC) separated from the spacecraft, entered the atmosphere, and ultimately landed at the Utah Test and Training Range for recovery. This paper gives an overview of the updated orbit determination (OD) covariance analysis that went into the Earth return and reentry analysis after asteroid departure. Tracking data assumptions and multiple filter cases are analyzed to show performance. Operational OD results from TCM-9 and subsequent targeting maneuvers up to entry interface are provided. We show parameter error analysis contributions from the OD setup and their breakdown in the B-Plane error ellipses. Finally, we discuss the terminal OD solutions into EI and reconstruction results using onboard image data.

Jason M. Leonard↗

Technical Note: Dose effects of 1.5 T transverse magnetic field on tissue interfaces in MRI-guided radiotherapy

Purpose: The integration of MRI with a linear accelerator (MR-linac) offers great potential for high-precision delivery of radiation therapy (RT). However, the electron deflection resulting from the presence of a transverse magnetic field (TMF) can affect the dose distribution, particularly the electron return effect (ERE) at tissue interfaces. The purpose of the study is to investigate the dose effects of ERE at air-tissue and lung-tissue interfaces during intensity-modulated radiation therapy (IMRT) planning. Methods: IMRT and volumetric modulated arc therapy (VMAT) plans for representative pancreas, lung, breast, and head and neck (HN) cases were generated following commonly used clinical dose volume (DV) criteria. In each case, three types of plans were generated: (1) the original plan generated without a TMF; (2) the reconstructed plan generated by recalculating the original plan with the presence of a TMF of 1.5 T (no optimization); and (3) the optimized plan generated by a full optimization with TMF = 1.5 T. These plans were compared using a variety of DV parameters, including V{sub 100%}, D{sub 95%}, DHI [dose heterogeneity index: (D{sub 20%}–D{sub 80%})/D{sub prescription}], D{sub max}, and D{sub 1cc} in OARs (organs at risk) and tissue interface. All the optimizations and calculations in this work were performed on static data. Results: The dose recalculation under TMF showed the presence of the 1.5 T TMF can slightly reduce V{sub 100%} and D{sub 95%} for PTV, with the differences being less than 4% for all but one lung case studied. The TMF results in considerable increases in D{sub max} and D{sub 1cc} on the skin in all cases, mostly between 10% and 35%. The changes in D{sub max} and D{sub 1cc} on air cavity walls are dependent upon site, geometry, and size, with changes ranging up to 15%. The VMAT plans lead to much smaller dose effects from ERE compared to fixed-beam IMRT in pancreas case. When the TMF is considered in the plan optimization, the dose effects of the TMF at tissue interfaces (e.g., air-cavity wall, lung-tissue interfaces, skin) are significantly reduced in most cases. Conclusions: The doses on tissue interfaces can be significantly changed by the presence of a TMF during MR-guided RT when the magnetic field is not included in plan optimization. These changes can be substantially reduced or even eliminated during VMAT/IMRT optimization that specifically considers the TMF, without deteriorating overall plan quality.

60 APPLIED LIFE SCIENCES↗

Engineering surface segregation of perovskite oxide through wet exsolution for CO catalytic oxidation

Cation segregation occurring near the surface or interfaces of solid catalysts plays an important role in catalytic reactions. Unfortunately, the native surface of perovskite oxides is dominated by passivated A-site segregation, which severely hampers the catalytic activity and durability of the system. To address this issue, we present a wet exsolution method to reconstruct surface segregation in perovskite cobalt oxide. Here, under reduction etching treatment of glycol solution, inert surface Sr segregation was transformed into active Co 3 O 4 segregation. By varying the reaction time, we achieved differing coverage of the active Co 3 O 4 segregation on the La 0.5 Sr 0.5 CoO 3-δ (LSCO) perovskite oxide surface. This study reveals that CO oxidation activity exhibits a volcano-shaped dependence on the coverage of Co 3 O 4 segregation at the surface of a perovskite cobalt oxide. Furthermore, we find that a suitable coverage of Co 3 O 4 segregation can dramatically improve the catalytic activity of the perovskite catalyst by enhancing interface interactions. Co K-edge, Co L-edge, and O K-edge X-ray absorption spectra confirm that the synergistic effect optimizes the covalence of the metal-oxygen bond at the surface and interface. This work not only contributes to the design of perovskite-type catalysts, but also provides important insight into the relationship between surface segregation and catalytic activity.

36 MATERIALS SCIENCE↗

δ -Doping of oxygen vacancies dictated by thermodynamics in epitaxial SrTiO 3 films

Homoepitaxial SrTiO 3 (110) film is grown by molecular beam epitaxy in ultra-high vacuum with oxygen diffusing from substrate as the only oxidant. The resulted oxygen vacancies (V O s ) are found to be spatially confined within few subsurface layers only, forming a quasi-two-dimensional doped region with a tunable high concentration. Such a δ-function distribution of V O s is essentially determined by the thermodynamics associated with the surface reconstruction, and facilitated by the relatively high growth temperature. Here, our results demonstrate that it is feasible to tune V O s distribution at the atomic scale by controlling the lattice structure of oxide surfaces. Transition metal oxide interfaces have exhibited a variety of novel phenomena, including the high-mobility two-dimensional electron gas, superconductivity and unusual magnetism. While these phenomena are inherently related to the artificially designed architecture, oxygen vacancies (V O s ) are recognized to be particularly important in determining the exotic behaviors of the oxides systems. As electron donors in oxides, V O s were observed to be one of the major factors for the high carrier density at the LaAlO 3 /SrTiO 3 interface. V O s induce ferromagnetism in the epitaxial LaCoO 3 films via the ordering of excess electrons in Co 3d orbit. It was also suggested that the existence of V O s plays an important role in the formation of undesirable insulating phase in ultrathin films of many metallic oxide materials, referred to as the “dead layer” behavior. How V O s are involved in such complex phenomena is still unclear. One essential issue toward the design of emergent properties of oxide films is how to characterize and control V O s at the atomic scale. Recently, quantitative measurements of V O concentration have been realized with high spatial resolution benefited by the development of the state-of-the-art aberration-corrected scanning transmission microscope (STEM) and related spectroscopy techniques. However, tuning the V O density precisely by growth control is still extremely challenging. Different oxidants, i.e., molecular O 2 , O 3 and atomic O, have been used with different feeding pressure during the growth. This approach is limited by thermodynamics of the material since the pressure of oxidant has to coordinate with temperature and other parameters in order to ensure the formation of the desired phase. In many cases the optimal condition for oxygen stoichiometry cannot be reached, and residual V O s are inevitably formed. It has been reported that V O s even form inhomogeneous clusters in SrTiO 3 (STO) films. Post annealing is another thermodynamic approach and seems to be effective to reduce the V O density. However, it does not allow the precise control of V O s distribution at the atomic scale either. In the current work, to study the control of V O s at the atomic scale, we grow SrTiO 3 homoepitaxial films along the polar [110] direction. Atomically well-defined (4 × 1) reconstruction is maintained on the surface all through the growth [see Fig. 1 (a) and (b)], which compensates the polarity. More importantly, the energy configuration associated with the surface reconstruction results in the spatial confinement of V O s within only few subsurface layers of the film, while their concentration remains extremely low on the topmost surface and in the bulk of STO substrate. In conclusion, we show that such a quasi-two-dimensional (2D) V O -doped layer, mimicking the δ-doping case in conventional semiconductors, can be precisely controlled.

36 MATERIALS SCIENCE↗

Resolving the Evolution of Atomic Layer-Deposited Thin-Film Growth by Continuous In Situ X-Ray Absorption Spectroscopy

In situ synchrotron X-ray absorption near-edge structure characterization of thin-film titania growth by atomic layer deposition (ALD) over ZnO nanowires reveals persistent low-coordinated Ti motifs leading to a new picture of ALD growth. Through the design of growth and measurement cycles, Ti K-edge spectral data are continuously recorded so as to characterize the film evolution as a function of ALD cycle number and the surface changes within the time scale of the ALD cycle. A unified set of analysis tools is developed to interpret the time-series of spectral data. A prenucleation stage of growth, a transition region, and then a steady-state growth stage are observed with distinguishable features. Multivariate curve resolution analysis, that is physically constrained, demonstrates two specific spectral components with associated, time-dependent concentrations. The bulk-film component tracks the stages of growth. The surface and interface components, present throughout the stages of growth, reveal a significant coverage of relatively isolated or loosely networked tetrahedrally coordinated Ti atomic motifs. Lastly, spectral signatures for the intra-cycle growth kinetics are reconstructed at a time resolution of ~1 s and demonstrate that the transient Ti motifs on the growing surface stabilize within a few seconds of the Ti precursor pulse.

36 MATERIALS SCIENCE↗

SU-G-201-04: Can the Dynamic Library of Flap Applicators Replace Treatment Planning in Surface Brachytherapy?

Purpose: Contemporary brachytherapy treatment planning systems-(TPS) include the applicator model libraries to improve digitization; however, the library of surface-flap-applicators-(SFA) is not incorporated into the commercial TPS. We propose the dynamic library-(DL) for SFA and investigate if such library can eliminate applicator reconstruction, source activation and dose normalization. Methods: DL was generated for the SFA using the C++class libraries of the Visualization Toolkit-(VTK) and Qt-application framework for complete abstraction of the graphical interface. DL was designed such that the user can initially choose the size of the applicator that corresponds to the one clinically placed to the patient. The virtual applicator-(VA) has an elastic property so that it can be registered to the clinical CT images with a real applicator-(RA) on it. The VA and RA matching is performed by adjusting the position and curvature of the VA. The VA does not elongate or change its size so each catheter could always be at a distance of 5mm from the skin and 10mm apart from the closest catheter maintaining the physical accuracy of the clinical setup. Upon the applicator placement, the dwell positions were automatically activated, and the dose is normalized to the prescription depth. The accuracy of source positioning was evaluated using various applicator sizes. Results: The accuracy of the applicator placement was in the sub-millimeter range. The time-study reveals that up to 50% of the planning time can be saved depending on the complexity of the clinical setup. Unlike in the classic approach, the planning time was not highly dependent on the applicator size. Conclusion: The practical benefits of the DL of the SFA were demonstrated. The time demanding planning processes can be partially automated. Consequently, the planner can dedicate effort to fine tuning, which can result in the improvement of the quality of treatment plans in surface brachytherapy.

60 APPLIED LIFE SCIENCES↗

Quantitative Electron Nanodiffraction.

This Final report summarizes progress under this award for the final reporting period 2002 - 2013 in our development of quantitive electron nanodiffraction to materials problems, especially devoted to atomistic processes in semiconductors and electronic oxides such as the new artificial oxide multilayers, where our microdiffraction is complemented with energy-loss spectroscopy (ELNES) and aberration-corrected STEM imaging (9). The method has also been used to map out the chemical bonds in the important GaN semiconductor (1) used for solid state lighting, and to understand the effects of stacking sequence variations and interfaces in digital oxide superlattices (8). Other projects include the development of a laser-beam Zernike phase plate for cryo-electron microscopy (5) (based on the Kapitza-Dirac effect), work on reconstruction of molecular images using the scattering from many identical molecules lying in random orientations (4), a review article on space-group determination for the International Tables on Crystallography (10), the observation of energy-loss spectra with millivolt energy resolution and sub-nanometer spatial resolution from individual point defects in an alkali halide, a review article for the Centenary of X-ray Diffration (17) and the development of a new method of electron-beam lithography (12). We briefly summarize here the work on GaN, on oxide superlattice ELNES, and on lithography by STEM.

36 MATERIALS SCIENCE↗

A solution-adaptive hybrid-grid method for the unsteady analysis of turbomachinery

A solution-adaptive method for the time-accurate analysis of two-dimensional flows in turbomachinery is described. The method employs a hybrid structured-unstructured zonal grid topology in conjunction with appropriate modeling equations and solution techniques in each zone. The viscous flow region in the immediate vicinity of the airfoils is resolved on structured O-type grids while the rest of the domain is discretized using an unstructured mesh of triangular cells. Implicit, third-order accurate, upwind solutions of the Navier-Stokes equations are obtained in the inner regions. In the outer regions, the Euler equations are solved using an explicit upwind scheme that incorporates a second-order reconstruction procedure. An efficient and robust grid adaptation strategy, including both grid refinement and coarsening capabilities, is developed for the unstructured grid regions. Grid adaptation is also employed to facilitate information transfer at the interfaces between unstructured grids in relative motion. Results for grid adaptation to various features pertinent to turbomachinery flows are presented. Good comparisons between the present results and experimental measurements and earlier structured-grid results are obtained.

Mathur, Sanjay R.↗

Triaxial Probe Magnetic Data Analysis

The Triaxial Magnetic Moment Analysis software uses measured magnetic field test data to compute dipole and quadrupole moment information from a hardware element. It is used to support JPL projects needing magnetic control and an understanding of the spacecraft-generated magnetic fields. Evaluation of the magnetic moment of an object consists of three steps: acquisition, conditioning, and analysis. This version of existing software was extensively rewritten for easier data acquisition, data analysis, and report presentation, including immediate feedback to the test operator during data acquisition. While prior JPL computer codes provided the same data content, this program has a better graphic display including original data overlaid with reconstructed results to show goodness of fit accuracy and better appearance of the report graphic page. Data are acquired using three magnetometers and two rotations of the device under test. A clean acquisition user interface presents required numeric data and graphic summaries, and the analysis module yields the best fit (least squares) for the magnetic dipole and/or quadrupole moment of a device. The acquisition module allows the user to record multiple data sets, selecting the best data to analyze, and is repeated three times for each of the z-axial and y-axial rotations. In this update, the y-axial rotation starting position has been changed to an option, allowing either the x- or z-axis to point towards the magnetometer. The code has been rewritten to use three simultaneous axes of magnetic data (three probes), now using two "rotations" of the device under test rather than the previous three rotations, thus reducing handling activities on the device under test. The present version of the software gathers data in one-degree increments, which permits much better accuracy of the fit ted data than the coarser data acquisition of the prior software. The data-conditioning module provides a clean data set for the analysis module. For multiple measurements at a given degree, the first measurement is used. For omitted measurements, the missing field is estimated by linear interpolation between the two nearest measurements. The analysis module was rewritten for the dual rotation, triaxial probe measurement process and now has better moment estimation accuracy, based on the finer one degree of data acquisition resolution. The magnetic moments thus computed are used as an input to summarize the total spacecraft field.

Shultz, Kimberly↗

Interfacial Coupling and Electronic Structure of Two-Dimensional Silicon Grown on the Ag(111) Surface at High Temperature

Freestanding silicene, a monolayer of Si arranged in a honeycomb structure, has been predicted to give rise to massless Dirac fermions, akin to graphene. However, Si structures grown on a supporting substrate can show properties that strongly deviate from the freestanding case. Here, combining scanning tunneling microscopy/spectroscopy and differential conductance mapping, we show that the electrical properties of the (√3 x √3) phase of few-layer Si grown on Ag(111) strongly depend on film thickness, where the electron phase coherence length decreases and the free-electron-like surface state gradually diminishes when approaching the interface. These features are presumably attributable to the inelastic inter-band electron-electron scattering originating from the overlap between the surface state, interface state and the bulk state of the substrate. We further demonstrate that the intrinsic electronic structure of the as grown (√3 x √3) phase is identical to that of the (√3 x √3) R30° reconstructed Ag on Si(111), both of which exhibit the parabolic energy-momentum dispersion relation with comparable electron effective masses. Lastly, these findings highlight the essential role of interfacial coupling on the properties of two-dimensional Si structures grown on supporting substrates, which should be thoroughly scrutinized in pursuit of silicene.

36 MATERIALS SCIENCE↗

Magnetic and structural properties of BiFeO{sub 3} thin films grown epitaxially on SrTiO{sub 3}/Si substrates

The integration of oxides with semiconductors is important for the technological advancement of the next generation electronics. Concomitant ferroelectric and antiferromagnetic (AF) behavior is demonstrated in single crystal BiFeO{sub 3} (BFO) films grown on 20 nm SrTiO{sub 3} (STO) virtual substrates on Si(100) using molecular beam epitaxy (MBE). STO thin films are grown in an oxide MBE chamber by co-deposition of Sr, Ti, and molecular O{sub 2}. Careful control of the O{sub 2} during nucleation produced commensurate growth of STO on Si. The sequence of the steps allows for the suppression of an amorphous SiO{sub 2} layer. This STO(20 nm)/Si structure was used as a virtual substrate for MBE deposition of BFO on Si without breaking vacuum. BFO was deposited using Fe and O{sub 2} plasma with an overpressure of Bi flux, the growth rate was controlled by the incoming Fe flux. The reflection high energy electron diffraction image shows a 2-D growth front with a 6-fold surface reconstruction under optimized O{sub 2} pressure of 5 Multiplication-Sign 10{sup -8} mbar. Cross-sectional transmission electron microscopy (TEM) confirms the high crystallinity of the films and shows sharp, atomically flat interfaces. The selected area diffraction pattern (SADP) reveals that BFO grows in a distorted rhombohedral crystal structure. X-ray diffraction does not show formation of second phases and is consistent with the TEM and SADP results. The BFO films show AF behavior with a Neel temperature that exceeds 350 K, as expected (T{sub N} = 673 K) and with a residual ferromagnetic behavior that decreases with film thickness and is consistent with the G-type AF due to the canted spins. The saturation magnetization per unit volume for a 40 nm thick film was 180 emu/cm{sup 3} at an in-plane magnetic field of 8 kOe. The ferroelectric behavior of the films was verified using piezoresponse force microscopy.

36 MATERIALS SCIENCE↗