Search NASA⌕ Search

SEARCH · Search NASA

Results for “Jefferson Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A New Era for Jefferson Lab

On a cool Saturday morning in late April a seemingly endless stream of cars turned off Jefferson Avenue in Newport News, Virginia, bringing 12,000 people ages 1 to 91 to the Open House to learn more about “the new era in science” at the Thomas Jefferson National Accelerator Facility. Here, the visitors were dazzled by the complex equipment, the enthusiastic staff, and the advanced technology at the Laboratory.

43 PARTICLE ACCELERATORS↗

Spin observables in charged pion photo-production from polarized neutrons in solid HD at Jefferson Lab

E asymmetries have been extracted from double-polarizationexperiments in Hall-B of the Thomas Jefferson National Accelerator Facility (JLab). Results have been obtained from the E06-101 (g14) experiment, using circularly polarized photon beams, longitudinally polarized Deuterons in solid HD targets, and the CEBAF Large Acceptance Spectrometer (CLAS). The results cover a range inW from 1.48 to 2.32 GeV. Three independent analyses, using distinctly different methods, have been combined to obtain the final values, which have been published recently. Partial wave analyses (PWA), which have had to rely on a sparse neutron data base, havebeen significantly changed with the inclusion of these g14 asymmetries.

Kageya, Tsuneo↗

The Jefferson Lab 12 GeV Upgrade

A major upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Facility is in progress. Construction began in 2008 and the project should be completed in 2015. The upgrade includes doubling the energy of the electron beam to 12 GeV, the addition of a new fourth experimental hall, and new experimental equipment in three of the experimental halls. A brief overview of this upgrade project is presented along with some highlights of the anticipated experimental program.

43 PARTICLE ACCELERATORS↗

AI for Experimental Controls at Jefferson Lab

We report the AI for Experimental Controls project is developing an AI system to control and calibrate detector systems located at Jefferson Laboratory. Currently, calibrations are performed offline and require significant time and attention from experts. This work would reduce the amount of data and the amount of time spent calibrating in an offline setting. The first use case involves the Central Drift Chamber (CDC) located inside the GlueX spectrometer in Hall D. We use a combination of environmental and experimental data, such as atmospheric pressure, gas temperature, and the flux of incident particles as inputs to a sequential Neural Network (NN) to recommend a high voltage setting and the corresponding calibration constants in order to maintain consistent gain and optimal resolution throughout the experiment. Utilizing AI in this manner represents an initial shift from offline calibration towards near real time calibrations performed at Jefferson Laboratory.

47 OTHER INSTRUMENTATION↗

Overview of SIDIS results from Hall B at Jefferson Lab

Though there are many applications of low energy positrons, many experiments are source limited. Using the LERF accelerator at the Thomas Jefferson National Accelerator Facility, it is possible to produce a high brightness source of very low-energy positrons. The accelerator requirements are well within the capabilities of the installed hardware. The accelerator can easily produce 50 kW of beam with a beam energy of up to 170 MeV. For these experiments, we only need run at up to 100 MeV. The gamma converter must be able to absorb the 50 kW of beam power that the linac delivers. At this low an energy the converter, though challenging, is possible. The transport of the low energy positrons from the production target to the next stage, where the energy is reduced even further, must have a very large acceptance to be able to efficiently transport the flux of positrons from the positron production target to the moderator. We propose to accomplish such a transport by means of a guiding solenoidal field with a novel end-cap design. In this presentation, we will present the proposed schemes necessary to realize such a high brightness positron source.

Benson, Stephen↗

Measurements of GEp/GMp to high Q2 and search for 2{gamma} contribution in elastic ep at Jefferson Lab

The ratio, μpGEp/GMp, where μp is the proton magnetic moment, has been measured extensively over the last decade at the Jefferson Laboratory, using the polarization transfer method. This ratio is extracted directly from the measured ratio of transverse to longitudinal polarizations components of the recoiling proton in elastic electron-proton scattering. The polarization transfer results are of unprecedented high precision and accuracy, due in large part to the small systematic uncertainties associated with the experimental technique. Prior to these measurements, the form factors were empirically observed to exhibit dipole forms, such that μpGEp/GMp ≈ 1 over all regions of momentum transfer studied. With the Hall A results confirming that the ratio μpGEp/GMp shows a steady decrease below unity as a function of Q2, beginning around Q2 ≈ 1 GeV2, discussions revolving around the implication of this deviation from dipole behavior for the structure of the proton have been accompanied by renewed experimental interest in these elastic form factors. Starting in the fall of 2007, two new experiments, GEp-III and GEp-2γ in Hall C at JLab, measured the form factor ratio, GEp/GMp; the GEp-III experiment pushed the highest Q2 limit from 5.6 to 8.49 GeV2, with intermediate points at 5.2 and 6.8 GeV2, and the GEp-2γ experiment measured the ratio in three different kinematics at the constant value Q2=2.5 GeV2, by changing beam energy and detector angles. Preliminary results from both experiments are reported.

43 PARTICLE ACCELERATORS↗

Electron Cloud Estimates for the Jefferson Lab EIC

In this work, we present preliminary estimates for electron cloud build-up and saturation for the ion ring of the Jefferson Laboratory Electron-Ion Collider (JLEIC) currently under development. Using the baseline ion ring design, we study the impact of various operational parameters on the behavior of the electron cloud for a 100 GeV proton beam, including estimated tune shifts.

Deitrick, K. E.↗

Fiducial Volumes for Photons Detected in the Electromagnetic Calorimeters of the CLAS Detector at Jefferson Lab

Fiducial volumes have been determined for photons detected in the electromagnetic calorimeters of the CEBAF Large Acceptance Spectrometer (CLAS) at the Thomas Jefferson National Accelerator Facility. This work is part of a systematic study of neutral meson photoproduction from the proton and light nuclear targets over an incident photon energy range of 0.5 - 1.5 GeV to investigate nuclear medium modifications of nucleon resonances and the meson-nucleon interaction. In this analysis the neutral mesons are reconstructed from their two-photon decay. The fiducial volumes define regions of the calorimeters with full photon detection efficiency. The volumes were determined by examining the photon hit distributions along the different scintillator planes in the sampling calorimeters. The procedure will be described and the results will be presented.

Shultz, Christian↗

Overview of torus magnet coil production at Fermilab for the Jefferson Lab 12-GeV Hall B upgrade

Fermi National Accelerator Laboratory (Fermilab) fabricated the torus magnet coils for the 12 GeV Hall B upgrade at Jefferson Laboratory (JLab). The production consisted of 6 large superconducting coils for the magnet and 2 spare coils. The toroidal field coils are approximately 2 m x 4 m x 5 cm thick. Each of these coils consists of two layers, each of which has 117 turns of copper-stabilized superconducting cable which will be conduction cooled by helium gas. Due to the size of the coils and their unique geometry, Fermilab designed and fabricated specialized tooling and, together with JLab, developed unique manufacturing techniques for each stage of the coil construction. In conclusion, this paper describes the tooling and manufacturing techniques required to produce the six production coils and two spare coils needed by the project.

43 PARTICLE ACCELERATORS↗

The proton form factor ratio results from Jefferson Lab

The ratio of the proton form factors, GE p/GMp, has been measured extensively, from Q2 of 0.5 GeV2 to 8.5 GeV2, at the Jefferson Laboratory, using the polarization transfer method. This ratio is extracted directly from the measured ratio of the transverse and longitudinal polarization components of the recoiling proton in elastic electron-proton scattering. The polarization transfer results are of unprecedented high precision and accuracy, due in large part to the small systematic uncertainties associated with the experimental technique. There is an approved experiment at JLab, GEP(5), to continue the ratio measurements to 12 GeV2. A dedicated experimental setup, the Super Bigbite Spectrometer (SBS), will be built for this purpose. It will be equipped with a focal plane polarimeter to measure the polarization of the recoil protons. The scattered electrons will be detected in an electromagnetic calorimeter. In this presentation, I will review the status of the proton elastic electromagnetic form factors and discuss a number of theoretical approaches to describe nucleon form factors.

43 PARTICLE ACCELERATORS↗

Jefferson Lab IEC 61508/61511 Safety PLC Based Safety System

This paper describes the design of the new 12 GeV Upgrade Personnel Safety System (PSS) at the Thomas Jefferson National Accelerator Facility (TJNAF). The new PSS design is based on the implementation of systems designed to meet international standards IEC61508 and IEC 61511 for programmable safety systems. In order to meet the IEC standards, TJNAF engineers evaluated several SIL 3 Safety PLCs before deciding on an optimal architecture. In addition to hardware considerations, software quality standards and practices must also be considered. Finally, we will discuss R&D that may lead to both high safety reliability and high machine availability that may be applicable to future accelerators such as the ILC. Key words: PLC, Safety, TJNAF, SIL, PSS, PPS, Software, ILC Notice: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. The U.S. Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce this manuscript for U.S. Government purposes.

43 PARTICLE ACCELERATORS↗

Status of the LCLS-II-HE Project at Jefferson Lab

The Linac Coherent Light Source II High Energy (LCLS-II-HE) upgrade at the SLAC National Accelerator Laboratory is being constructed in partnership with the Thomas Jefferson National Accelerator Facility (JLab) and the Fermi National Accelerator Laboratory (FNAL). The cryomodule production scope consists of the design, procurement, construction, and acceptance testing of 24 eight-cavity, 1.3 GHz cryomodules, as well as R&D activities necessary to develop the required technology. To achieve this, JLab and FNAL are also contributing to SLAC’s effort to develop the cavity recipe and production processes necessary to meet the LCLS-II-HE goal of 20.8 MV/m and average Q₀ of 2.7·10¹⁰. This paper details the JLab scope, focusing on the project initiation phase, in particular technology development and prototyping, project development and planning, and implementation of lessons learned from LCLS-II.

Wilson, K. M.↗

The Proton Form Factor Ratio Measurements at Jefferson Lab

The ratio of the proton form factors, G{sub Ep}/G{sub Mp}, has been measured from Q{sup 2} of 0.5 GeV{sup 2} to 8.5 GeV{sup 2}, at the Jefferson Laboratory, using the polarization transfer method. This ratio is extracted directly from the measured ratio of the transverse and longitudinal polarization components of the recoiling proton in elastic electron-proton scattering. The discovery that the proton form factor ratio measured in these experiments decreases approximately linearly with four-momentum transfer, Q{sup 2}, for values above ~1 GeV{sup 2}, is one of the most significant results to come out of JLab. These results have had a large impact on progress in hadronic physics; and have required a significant rethinking of nucleon structure. The increasingly common use of the double-polarization technique to measure the nucleon form factors, in the last 15 years, has resulted in a dramatic improvement of the quality of all four nucleon electromagnetic form factors, G{sub Ep}, G{sub Mp}, G{sub En} and G{sub Mn}. There is an approved experiment at JLab, GEP(V), to continue the ratio measurements to 12 GeV{sup 2}. A dedicated experimental setup, the Super Bigbite Spectrometer (SBS), will be built for this purpose. It will be equipped with a focal plane polarimeter to measure the polarization of the recoil protons. The scattered electrons will be detected in an electromagnetic calorimeter. In this presentation, I will review the status of the proton elastic electromagnetic form factors and discuss a number of theoretical approaches to describe nucleon form factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strong interaction physics at the luminosity frontier with 22 GeV electrons at Jefferson Lab

Here, the purpose of this document is to outline the developing scientific case for pursuing an energy upgrade to 22 GeV of the Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Facility (TJNAF, or JLab). This document was developed with input from a series of workshops held in the period between March 2022 and April 2023 that were organized by the JLab user community and staff with guidance from JLab management (see Sec. 10). The scientific case for the 22 GeV energy upgrade leverages existing or already planned Hall equipment and world-wide uniqueness of CEBAF high-luminosity operations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the EMC Effect of the Helium-3 Nucleus at Jefferson Lab

The MARATHON (MeAsurement of the Fn 2 /Fp 2 , d/u RAtios and A=3 EMC Effect in Deep Inelastic Scattering Off the Tritium and Helium MirrOr Nuclei) experiment ran in the Hall A Facility of the Thomas Jefferson National Accelerator Facility (JLab). The experiment used a 10.59 GeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) of JLab to measure the ratio of the F2 structure functions of Helium-3 and Deuterium. Data were taken in the kinematic range of 0.195 lte x lte 0.825, 2.5 (GeV/c)2 lte Q2 lte 13 (GeV/c)2, and 3.5 (GeV/c2)^2 lte W^2 lte 13 (GeV/c2)^2. This is the first measurement of the 3He EMC effect that is purely in the Deep Inelastic Scattering region. The results of this experiment constitute an important, complimentary addition, to the limited data presently available for the EMC effect of light nuclei. The MARATHON results are compared to the world data for light, medium, and heavy nuclei. This measurement is considered an essential component to uncovering the nature of the EMC effect.

Hague, Tyler↗

Extraction of the Compton Form Factor H from recent DVCS measurements at Jefferson Lab

Working at twist 2 accuracy and assuming the dominance of the Generalized Parton Distribution H we study the helicity-dependent and independent cross sections measured in Hall A and the beam spin asymmetries measured in Hall B at Jefferson Laboratory. We extract the real and imaginary parts of the Compton Form Factor H, the latter being obtained with a 20–50 % uncertainty. We discuss our results and compare to other extractions as well as to the popular VGG model. We pay extra attention to the estimation of systematic errors on the extraction of H.

43 PARTICLE ACCELERATORS↗

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗