GPU-accelerated DNS of compressible turbulent flows

Here, this paper explores strategies to transform an existing CPU-based high-performance computational fluid dynamics solver, HyPar, for compressible flow simulations on emerging exascale heterogeneous (CPU+GPU) computing platforms. The scientific motivation for developing a GPU-enhanced version of HyPar is to simulate canonical turbulent flows at the highest resolution possible on such platforms. We show that optimizing memory operations and thread blocks results in 200x speedup of computationally intensive kernels compared with a CPU core. Using multiple GPUs and CUDA-aware MPI communication, we demonstrate both strong and weak scaling of our GPU-based HyPar implementation on the NVIDIA Volta V100 GPUs. We simulate the decay of homogeneous isotropic turbulence in a triply periodic box on grids with up to 1024 3 points (5.3 billion degrees of freedom) and on up to 1,024 GPUs. We compare the wall times for CPU-only and CPU+GPU simulations. The results presented in the paper are obtained on the Summit and Lassen supercomputers at Oak Ridge and Lawrence Livermore National Laboratories, respectively.

97 MATHEMATICS AND COMPUTING↗

RANSBox: A zero-dimensional modular software package for Reynolds-averaged Navier-Stokes modeling

RANSBox is a zero-dimensional software package for Reynolds-averaged Navier-Stokes (RANS) modeling developed at Lawrence Livermore National Laboratory to support common implementation of RANS models across a variety of host codes with different numerical schemes and code bases. Herein this work describes the key features of RANSBox including “model-agnostic integration,” which allows new models to be implemented in RANSBox and quickly deployed to host codes without additional changes to the host code base. Three one-dimensional test problems with analytical asymptotic properties are described which can be used to verify correctness of RANSBox integration. Results for these problems are then compared across different RANS models in a single code and across different codes with a common RANS model. By using a common model implementation in RANSBox, host codes with different numerical schemes and formal orders of accuracy are demonstrated to predict the expected behavior for the three test problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute photoionization cross sections of brominated organics and determination of an effective C—Br bond cross section

For this work, absolute photoionization cross sections for five brominated species were measured using multiplexed synchrotron photoionization mass spectrometry at the Advanced Light Source (Lawrence Berkeley National Laboratory). These data enable reliable detection of bromine-containing compounds and estimation of C—Br bond photoionization cross sections. Complementary electronic-structure calculations provided adiabatic ionization energies in good agreement with experiment, while thermochemical appearance energies were measured directly. Bond dissociation energies for key fragmentation pathways of the neutral parent molecules were also analyzed. At 11 eV, cross sections were 53.8 ± 7.50 Mb (sp 2 C—Br) and 48.8 ± 7.70 Mb (sp 3 C—Br).

Brominated compounds↗

Assessing Single-Source Reproducibility of Human Head Hair Peptide Profiling from Different Regions of the Scalp

Neither microscopical hair comparisons nor mitochondrial DNA sequencing alone, or together, constitutes a basis for personal identification. Due to these limitations, a complementary technique to compare questioned and known hair shafts was investigated. Recently, scientists from Lawrence Livermore National Laboratory's Forensic Science Center and other collaborators developed a peptide profiling technique, which can infer non-synonymous single nucleotide polymorphisms (SNPs) preserved in hair shaft proteins as single amino acid polymorphisms (SAPs). In this study, peptide profiling was evaluated to determine if it can meet forensic expectations when samples are in limited quantities with the possibility that hair samples collected from different areas of a single donor’s scalp (i.e., single source) might not exhibit the same SAP profile. The average dissimilarity, percent differences in SAP profiles within each source, ranged from 0% difference to 29%. This pilot study suggests that more work is needed before peptide profiling of hair can be considered for forensic comparisons.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-element isotopic analysis of hot particles from Chornobyl

Microscopic fuel fragments, so-called “hot particles”, were released during the 1986 accident at the Chornobyl nuclear powerplant and continue to contaminate the exclusion zone in northern Ukraine. Isotopic analysis can provide vital information about sample origin, history and contamination of the environment, though it has been underutilized due to the destructive nature of most mass spectrometric techniques, and inability to remove isobaric interference. Recent developments have diversified the range of elements that can be investigated through resonance ionization mass spectrometry (RIMS), notably in the fission products. The purpose of this study is to demonstrate the application of multi-element analysis on hot particles as relates to their burnup, particle formation in the accident, and weathering. The particles were analysed with two RIMS instruments: resonant-laser secondary neutral mass spectrometry (rL-SNMS) at the Institute for Radiation Protection and Radioecology (IRS) in Hannover, Germany, and laser ionization of neutrals (LION) at Lawrence Livermore National Laboratory (LLNL) in Livermore, USA. Comparable results across instruments show a range of burnup dependent isotope ratios for U and Pu and Cs, characteristic of RBMK-type reactors. Results for Rb, Ba and Sr show the influence of the environment, retention of Cs in the particles and time passed since fuel discharge.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of the Prompt Fission Gamma Properties for Neutron Induced Fission of 235,238 U and 239 Pu

Herein we present details of the prompt fission gamma property evaluations included in the released ENDF/B-VIII.0 files. The average prompt gamma multiplicity, the average prompt gamma spectrum, the average total prompt gamma energy released and the prompt gamma multiplicity distributions, included in the ENDF/B-VIII.0 files, are presented for 235 U(n,f), 238 U(n,f), and 239 Pu(n,f) reactions, as a function of incident neutron energy up to 30 MeV. The evaluation is based on available experimental data and model calculations. Notable data include recent measurements by experimental groups at Los Alamos and Lawrence Livermore National Laboratories, at Geel and Budapest, at CEA labs, as well as seminal historical gamma production measurements by Drake at Los Alamos.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced light source-Upgrade accumulator-ring gas bremsstrahlung production

Lawrence Berkeley National Laboratory is designing a new electron synchrotron for scientific research using synchrotron radiation. An upgrade of the Advanced Light Source (ALS) would position the nation to retain its international competitiveness in the soft X-ray sciences. The ALS is a 1.9 GeV storage ring operating at 500 mA of beam current. It is optimized to produce intense beams of soft X-rays, which offer spectroscopic contrast, nanometer-scale resolution, and broad temporal sensitivity. Upgrading the ALS storage ring from a triple-bend-achromat to a multibend-achromat (MBA) lattice design will provide a soft X-ray source that is up to 100–1,000 times brighter than today’s ALS and will provide a significantly higher fraction of coherent light in the soft X-ray region than is currently available at the ALS. Further, the upgraded ALS will offer the highest coherent flux of any existing or planned storage-ring facility, worldwide, up to a photon energy of 3.5 keV. The addition of an accumulator ring that enables on-axis, swap-out, recovery, and exchange of bunch trains is required to achieve this coherence and brightness. Analysis of the radiation generated and shielding required by the addition of this new accelerator is presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uranium measurements in the field using high-resolution cadmium zinc telluride detectors

A new generation of cadmium zinc telluride (CZT) detectors has become available and is being evaluated by the International Atomic Energy Agency (IAEA) for safeguards verifications in the field. The new CZT detector, model M400, is a room temperature spectrometer manufactured by H3D, Inc. The M400 demonstrates superior energy resolution, effective isotope identification capabilities, and convenient usability features when tested in a controlled laboratory environment. These characteristics define the M400 as a potential platform for IAEA field detection applications, which could become suitable for nuclear material characterization (e.g., enrichment verification) and nuclear safeguards missions. The capabilities of gamma spectrometry codes including Fixed energy, Response function Analysis with Multiple efficiencies (FRAM) from Los Alamos National Laboratory, CZT for Uranium (CZTU) from Lawrence Livermore National Laboratory, and Gamma Detector Response and Analysis Software (GADRAS) from Sandia National Laboratories were adapted for M400 spectra, and the performance of the codes has been validated. This was reported in a prior work. To further validate the performance of the high-energy resolution CZT detector and the isotopic analysis codes, a field measurement campaign consisting of uranium hexafluoride (UF 6 ) cylinder measurements was conducted at a fuel fabrication facility. A total of 34 Type 30B cylinders containing UF6 were measured using three different M400 CZT detectors. Each detector was outfitted with a custom rectangular collimator and shield made out T-Flex®, a tungsten-impregnated polymer. Measurements were performed at three different locations of the cylinder, ensuring that the measurement geometry satisfied the infinite thickness criterion. The spectra from the M400 CZT were analyzed using the code General Enrichment Meter (GEM). For analyzing the gamma-ray spectra from UF 6 cylinder, the GEM code is the appropriate tool since it relies only on the gamma-ray emissions from 235 U and not from other isotopes. Results from the spectral analysis were compared with the known abundance of 235 U in the cylinders, as well as with the International Target Values 2020 (ITV2020). The suitability of the different underlying techniques used by the various codes for UF 6 analysis is discussed. The challenges of measuring UF 6 contained in cylinders and mitigation strategies are highlighted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute decay counting of 146 Sm with 4π cryogenic microcalorimetry

We present a methodology for absolute activity counting of long-lived isotopes based on cryogenic Decay Energy Spectroscopy. A 146 Sm source was produced at the TRIUMF Laboratory and then processed and purified at Lawrence Livermore National Laboratory, yielding a pure sample. The source was embedded within a 4π thermal absorber coupled to a magnetic microcalorimeter achieving nearly 100% counting efficiency. Experimental uncertainties were studied and modeled, including thermal coupling of the source to the absorber, pulse pile-up, trigger, and event selection efficiencies. Here, the absolute activity of the pure 146 Sm source was measured to better than 1% uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conversion of the LLNL/CAMS 1 MV biomedical AMS system to a semi-automated natural abundance 14C spectrometer: system optimization and performance evaluation

The Lawrence Livermore National Laboratory – Center for Accelerator Mass Spectrometry compact 1 MV biomedical accelerator mass spectrometer was repurposed and optimized for the semi-automated radiocarbon measurement of natural abundance environmental samples. Here we present results from 15 months of routine system operation and evaluate the system performance based on 30 sample wheels measured with consistent operating conditions over 7 months from August 2019 to March 2020. Additionally, the average measurement precision was 2.7 ± 0.7‰. System accuracy was assessed with measurements of 14 C-free materials, standard materials with 14 C-content spanning 0.5 to 1.5 F 14 C, and by comparison to split samples measured with the 10 MV AMS system. Overall, this system can routinely measure samples as small as 300 µgC and less than 33000 years without the need for size-specific correction protocols.

43 PARTICLE ACCELERATORS↗

The effects of high energy deuteron ion beam irradiation on the tensile behavior of HT-9

Ion beam implantations are widely performed to understand the effects of irradiation-induced displacement damage on nuclear structural materials. However, the volume of material that can be investigated is often limited by the maximum energies of accelerator facilitates, leading to a limitation in the thickness of samples whose mechanical properties can be evaluated. The Lawrence Berkeley National Laboratory’s 88-Inch Cyclotron offers a wide range of ions and energies, allowing for material ion implantations at larger scales than typical. Four HT-9 SS-J-geometry tensile specimens were polished and then irradiated with deuterons at the 88-Inch Cyclotron to doses of approximately 0.2 dpa prior to small scale tensile testing. Here, the results from this study show irradiation hardening characterized by the tensile test results and black dot irradiation defects. Additionally, a comprehensive look at low temperature irradiations of high-Cr F/M steels is presented and our results show agreement with the available data.

36 MATERIALS SCIENCE↗

Quantifying replication through repeated analysis of UVM-A, a liquid reference material for cosmogenic 10 Be and 26 Al studies

In this study, in-situ produced cosmogenic nuclide sample preparation and analysis is a complicated, multi-step process with numerous possible sources of error, many of which have not been robustly quantified. Here, we use a liquid reference material (UVM-A) to test whether the analytic precision associated with individual isotopic ratios (n = 96) measured at two Accelerator Mass Spectrometry facilities (Lawrence Livermore National Laboratory and Purdue Rare Isotope Measurement Laboratory) accurately represents the range of values determined for aliquots prepared in a single laboratory over a period of five years. We find that 10 Be/ 9 Be ratios measured at the different accelerator facilities (n = 26 and n = 70) have statistically indistinguishable central tendencies, matching to within 0.1 %. Based on this large dataset, we suggest preliminary consensus values for UVM-A of 1.45 ± 0.06 x 10 -13 for 10 Be/ 9 Be (mean, one standard deviation, n = 96) and 4.47 ± 0.22 x 10 -13 for 26 Al/ 27 Al (mean, one standard deviation, n = 27). For both 10 Be/ 9 Be and 26 Al/ 27 Al, the relative standard deviations of the measured ratios are similar to the reported analytic uncertainties of sample measurement, suggesting that sample preparation introduced little if any additional scatter beyond the uncertainty of isotopic analysis. This dataset demonstrates that robust sample preparation and measurement can generate isotope ratio data reproducible at the level of counting statistics.

58 GEOSCIENCES↗

Gut microbiome associations with outcome following co-infection with porcine reproductive and respiratory syndrome virus (PRRSV) and porcine circovirus type 2 (PCV2) in pigs immunized with a PRRS modified live virus vaccine

Porcine reproductive and respiratory syndrome virus (PRRSV) and porcine circovirus type 2 (PCV2) are two of the most significant pathogens affecting swine. Co-infections are common and result in respiratory disease and reduced weight gain in growing pigs. Although PRRS modified live virus (MLV) vaccines are widely used to decrease PRRS-associated losses, they are generally considered inadequate for disease control. The gut microbiome provides an alternative strategy to enhance vaccine efficacy and improve PRRS control. The objective of this work was to identify gut microbiome characteristics associated with improved outcome in pigs immunized with a PRRS MLV and co-challenged with PRRSV and PCV2b. Twenty-eight days after vaccination and prior to co-challenge, fecal samples were collected from an experimental population of 50 nursery pigs. At 42 days post-challenge, 20 pigs were retrospectively identified as having high or low growth outcomes during the post-challenge period. Gut microbiomes of the two outcome groups were compared using the Lawrence Livermore Microbial Detection Array (LLMDA) and 16S rDNA sequencing. High growth outcomes were associated with several gut microbiome characteristics, such as increased bacterial diversity, increased Bacteroides pectinophilus, decreased Mycoplasmataceae species diversity, higher Firmicutes:Bacteroidetes ratios, increased relative abundance of the phylum Spirochaetes, reduced relative abundance of the family Lachnospiraceae, and increased Lachnospiraceae species C6A11 and P6B14. Overall, this study identifies gut microbiomes associated with improved outcomes in PRRS vaccinated pigs following a polymicrobial respiratory challenge and provides evidence towards the gut microbiome playing a role in PRRS vaccine efficacy.

59 BASIC BIOLOGICAL SCIENCES↗

Classical-quantum simulation of non-equilibrium Marshak waves

In the radiation hydrodynamic simulations used to design inertial confinement fusion (ICF) and pulsed power experiments, nonlinear radiation diffusion tends to dominate CPU time. This raises the interesting question of whether a quantum algorithm can be found for nonlinear radiation diffusion which provides a quantum speedup. Recently, such a quantum algorithm was introduced based on a quantum algorithm for solving systems of nonlinear partial differential equations (PDEs) which provides a quadratic quantum speedup. Here, we apply this quantum PDE (QPDE) algorithm to the problem of a non-equilibrium Marshak wave propagating through a cold, semi-infinite, optically thick target, where the radiation and matter fields are not assumed to be in local thermodynamic equilibrium. The dynamics is governed by a coupled pair of nonlinear PDEs which are solved using the QPDE algorithm, as well as two standard PDE solvers: (i) Python's py-pde solver; and (ii) the KULL ICF simulation code developed at Lawrence-Livermore National Laboratory. We compare the simulation results obtained using the QPDE algorithm and the standard PDE solvers and find excellent agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Case Study in Assessing a Potential Severity Framework for Incidents from a Decadal Sample

In this study, the primary objective of this case study is to determine the applicability and feasibility of a framework that leverages occupational incident details to prospectively identify “potential Serious Injury or Fatality” (pSIF) cases. This study comprehensively reviewed a random sample of 1,081 injury and illness cases across 21 generalized incident types spanning over a decade at Lawrence Livermore National Laboratory (LLNL), a U.S. Department of Energy research and development facility with more than 9,000 employees. The review applied a general framework that classified each case on information suitability, potential severity, and future incident mitigation. The findings from the study indicate that 86.6% of the cases had sufficient information to make a high-confidence determination on potential severity, underscoring the feasibility of applying this general framework. Additionally, cases with a higher pSIF score had, on average, a higher level of institutional response. Implementing a simplified methodology for incident classification that emphasizes incidents that pose high potential severity, regardless of incident type, can help LLNL prioritize resources and tailor responses to such incidents using a graded approach. LLNL has recognized the value of this capability and is integrating the framework into their injury and illness process in the 2024 calendar year.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Assessment of the Second-Ionization Potential of Lawrencium: Investigating the End of the Actinide Series with a One-Atom-at-a-Time Gas-Phase Ion Chemistry Technique

Experiments were performed at the Lawrence Berkeley National Laboratory 88-Inch Cyclotron facility to investigate the electron-transfer reduction reaction of dipositive Lr ( Z = 103) with O 2 gas. Ions of 255 Lr were produced in the fusion-evaporation reaction 209 Bi( 48 Ca,2n) 255 Lr and were studied with a novel gas-phase ion chemistry technique. The produced 255 Lr 2+ ions were trapped and O 2 gas was introduced, such that the charge-exchange reaction to reduce 255 Lr 2+ to 255 Lr 1+ was observed and the reaction rate constant was determined to be k = 1.5(7) × 10 -10 cm 3 /mol/s. The observation that this reaction proceeds establishes the lower limit on the second ionization potential of Lr to be 13.3(3) eV. This gives further support that the actinide series terminates with Lr. Additionally, this result can be used to better interpret the situation concerning the placement of Lu and Lr on the periodic table within the current framework of the actinide hypothesis. The success of this experimental approach now identifies unique opportunities for future gas-phase reaction studies on actinide and super heavy elements.

36 MATERIALS SCIENCE↗

Investigation of O( 3 P) Initiated Oxidation Products of 2,3-Dimethylfuran Using Synchrotron Photoionization

Biofuels are an appealing alternative to augment conventional fossil fuels, given that traditional fossil fuels are finite in nature despite being the highest-consumed energy source. Furans have been studied as potential biofuels due to their renewability, high energy density, and ability to both blend with existing fossil fuels and serve as a stand-alone fuel. Although promising, more research efforts on the combustion of furan-based biofuels are needed. Here, in this study, the oxidation of 2,3-dimethylfuran (2,3-DMF) initiated by O( 3 P) was investigated using vacuum-ultraviolet synchrotron radiation from the Advanced Light Source at the Lawrence Berkeley National Laboratory. The reaction was studied at 550 K and 7 Torr. Major reaction products include 3-methyl-3-buten-2-one, 4,5-dimethyl-3(2H)-furanone, and 3-methyl-4-oxo-2(Z)-pentenal, with 3-methyl-3-buten-2-one being the most abundant.

CBS-QB3↗