Search NASA⌕ Search

SEARCH · Search NASA

Results for “Leak Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Improved Vacuum-Tight Connector

Simple reinforcing tube increases service life and improves seal. Short stainless-steel tube inserted in copper tube to reinforce against compression, preventing leaks due to thermal distortion or to collapse under squeeze of ferrule in compressure fitting. Several test specimens of improved connector constructed, tested, and evaluated. Fittings not only operated successfully at required operating conditions of vacuum and temperature but also consistently demonstrated high reliability after loosened and tightened many times.

Rudin, Frank↗

An experimental study on the static and dynamic characteristics of pump annular seals with two phase flow

A new test apparatus is reconstructed and is applied to investigate static and dynamic characteristics of annular seals leaked by two phase flow (gas and liquid) for turbopumps. The fluid forces acting on the seals are measured for various parameters such as void ratio, the preswirl velocity, the pressure difference between the inlet and outlet of the seal, the whirling amplitude, and the ratio of whirling speed to spinning speed of the rotor. Influence of these parameters on the static and dynamic characteristics is investigated from the experimental results. As a result, with regard to the two phase flow, as the void ratio increases, the flow induced force decreases. Another dynamic characteristic of two phase flow is as almost similar as that of the monophase flow.

Iwatsubo, T.↗

Use of Raman Spectroscopy and Delta Volume Growth from Void Collapse to Assess Overwrap Stress Gradients Compromising the Reliability of Large Kevlar/Epoxy COPVs

Composite Overwrapped Pressure Vessels (COPVs) are frequently used for storing pressurized gases aboard spacecraft and aircraft when weight saving is desirable compared to all-metal versions. Failure mechanisms in fibrous COPVs and variability in lifetime can be very different from their metallic counterparts; in the former, catastrophic stress-rupture can occur with virtually no warning, whereas in latter, a leak before burst design philosophy can be implemented. Qualification and certification typically requires only one burst test on a production sample (possibly after several pressure cycles) and the vessel need only meet a design burst strength (the maximum operating pressure divided by a knockdown factor). Typically there is no requirement to assess variability in burst strength or lifetime, much less determine production and materials processing parameters important to control of such variability. Characterizing such variability and its source is crucial to models for calculating required reliability over a given lifetime (e.g. R = 0.9999 for 15 years). In this paper we present a case study of how lack of control of certain process parameters in COPV manufacturing can result in variations among vessels and between production runs that can greatly increase uncertainty and reduce reliability. The vessels considered are 40-inch ( NASA Glenn Research center, Cleveland, OH, 44135 29,500 in3 ) spherical COPVs with a 0.74 in. thick Kevlar49/epoxy overwrap and with a titanium liner of which 34 were originally produced. Two burst tests were eventually performed that unexpectedly differed by almost 5%, and were 10% lower than anticipated from burst tests on 26-inch sister vessels similar in every detail. A major observation from measurements made during proof testing (autofrettage) of the 40-inch vessels was that permanent volume growth from liner yielding varied by a factor of more than two (150 in3 to 360 in3 ), which suggests large differences in the residual stress gradient through their overwraps. This resulted in large uncertainty in true fiber stress ratio (fiber stress at operating pressure divided by fiber stress at burst) which governs lifetime. The vessels were originally designed with tight safety margins, so it became crucial to develop a non-destructive evaluation (NDE) technique to directly measure the overwrap residual stress state of each vessel, and to identify those vessels at highest risk of having poor reliability. This paper describes a Raman Spectroscopy technique for measuring certain patterns of fluctuation in fiber elastic strains over the outside vessel surface (where all but one wrap is exposed at certain locations) that are shown to directly correlate to increased fiber stress ratios and reduced reliability.

Kezirian, Michael T.↗

Helium-Cooled Black Shroud for Subscale Cryogenic Testing

This shroud provides a deep-space simulating environment for testing scaled-down models of passively cooling systems for spaceflight optics and instruments. It is used inside a liquid-nitrogen- cooled vacuum chamber, and it is cooled by liquid helium to 5 K. It has an inside geometry of approximately 1.6 m diameter by 0.45 m tall. The inside surfaces of its top and sidewalls have a thermal absorptivity greater than 0.96. The bottom wall has a large central opening that is easily customized to allow a specific test item to extend through it. This enables testing of scale models of realistic passive cooling configurations that feature a very large temperature drop between the deepspace-facing cooled side and the Sun/Earth-facing warm side. This shroud has an innovative thermal closeout of the bottom wall, so that a test sample can have a hot (room temperature) side outside of the shroud, and a cold side inside the shroud. The combination of this closeout and the very black walls keeps radiated heat from the sample s warm end from entering the shroud, reflecting off the walls and heating the sample s cold end. The shroud includes 12 vertical rectangular sheet-copper side panels that are oriented in a circular pattern. Using tabs bent off from their edges, these side panels are bolted to each other and to a steel support ring on which they rest. The removable shroud top is a large copper sheet that rests on, and is bolted to, the support ring when the shroud is closed. The support ring stands on four fiberglass tube legs, which isolate it thermally from the vacuum chamber bottom. The insides of the cooper top and side panels are completely covered with 25- mm-thick aluminum honeycomb panels. This honeycomb is painted black before it is epoxied to the copper surfaces. A spiral-shaped copper tube, clamped at many different locations to the outside of the top copper plate, serves as part of the liquid helium cooling loop. Another copper tube, plumbed in a series to the top plate s tube, is clamped to the sidewall tabs where they are bolted to the support ring. Flowing liquid helium through these tubes cools the entire shroud to 5 K. The entire shroud is wrapped loosely in a layer of double-aluminized Kapton. The support ring s inner diameter is the largest possible hole through which the test item can extend into the shroud. Twelve custom-sized trapezoidal copper sheets extend inward from the support ring to within a few millimeters of the test item. Attached to the inner edge of each of these sheets is a custom-shaped strip of Kapton, which is aluminum- coated on the warm-facing (outer) side, and has thin Dacron netting attached to its cold-facing side. This Kapton rests against the test item, but the Dacron keeps it from making significant thermal contact. The result is a non-contact, radiatively reflective thermal closeout with essentially no gap through which radiation can pass. In this way, the part of the test item outside the shroud can be heated to relatively high temperatures without any radiative heat leaking to the inside.

Tuttle, James↗

Effects of flow separation and cove leakage on pressure and heat-transfer distributions along a wing-cove-elevon configuration at Mach 6.9

External and internal pressure and cold-wall heating-rate distributions were obtained in hypersonic flow on a full-scale heat-sink representation of the space shuttle orbiter wing-elevon-cove configuration in an effort to define effects of flow separation on cove aerothermal environment as a function of cove seal leak area, ramp angle, and free-stream unit Reynolds number. Average free-stream Mach number from all tests was 6.9; average total temperature from all tests was 3360 R; free-stream dynamic pressure ranged from about 2 to 9 psi; and wing angle of attack was 5 deg (flow compression). For transitional and turbulent flow separation, increasing cove leakage progressively increased heating rates in the cove. When ingested mass flow was sufficient to force large reductions in extent of separation, increasing cove leakage reduced heating rates in the cove to those for laminar attached flow. Cove heating-rate distributions calculated with a method that assumed laminar developing channel flow agreed with experimentally obtained distributions within root-mean-square differences that varied between 11 and 36 percent where cove walls were parallel for leak areas of 50 and 100 percent.

Deveikis, W. D.↗

SSME Propellant Path Leak Detection

The primary objective of this phase of the investigation is the experimental validation of techniques for detecting and analyzing propellant path external leaks which have a high probability of occurring on the SSME. The selection of candidate detection methods requires a good analytic model for leak plumes which would develop from external leaks and an understanding of radiation transfer through the leak plume. One advanced propellant path leak detection technique is obtained by using state-of-art technology of infrared (IR) thermal imaging systems combined with computer, digital image processing and expert systems for the engine protection. The feasibility of the IR leak plume detection will be evaluated on subscale simulated laboratory plumes to determine sensitivity, signal to noise, and general suitability for the application. The theoretical analysis was undertaken with the objective of developing and testing simple, easy-to-use models to predict the amount of radiation coming from a radiation source, background plate (BP), which can be absorbed, emitted and scattered by the gas leaks.

Roger Crawford↗

xPLSS Structural Backplate Design, Manufacture, and Test Overview

NASA Johnson Space Center (JSC) has been developing and building a new detailed design of the Exploration Extravehicular Mobility Unit (xEMU) space suit to support future International Space Station (ISS) and Lunar Artemis missions. The Exploration Portable Life Support System (xPLSS) of the xEMU contains some clever new technologies to meet the requirements to provide Extra Vehicular Activity (EVA) capability on the ISS and the Moon. The suit must interface with and fit through ports and airlocks of at least three vehicles: ISS, Human Landing System (HLS), and Gateway. The first partial xPLSS experimental flight unit called SWME EXPRESS Rack Flight Experiment (SERFE) that was a rack-deployed thermal control system payload on the ISS for two years (2020-2022). The first complete assembly of the xEMU was built as a Design Verification Test (DVT) unit (2022); similar to but more extensive than an Engineering Development Unit (EDU). The xPLSS Backplate serves not only as the structural backbone of the xPLSS and SERFE systems but also contains innovative design features to reduce the: mass, complexity, parts count, number ofseals (and therefore leak potential), and outer dimensions of the entire assembly. This paper provides an overview of these new design features, manufacturing processes, system interfaces, and SERFE/DVT test results of the Backplate as part of the xPLSS/xEMU.

xPLSS↗

xPLSS Structural Backplate Design, Manufacture, and Test Overview

NASA Johnson Space Center (JSC) has been developing and building a new detailed design of the Exploration Extravehicular Mobility Unit (xEMU) space suit to support future International Space Station (ISS) and Lunar Artemis missions. The Exploration Portable Life Support System (xPLSS) of the xEMU contains some clever new technologies to meet the requirements to provide Extra Vehicular Activity (EVA) capability on the ISS and the Moon. The suit must interface with and fit through ports and airlocks of at least three vehicles: ISS, Human Landing System (HLS), and Gateway. The first partial xPLSS experimental flight unit called SWME EXPRESS Rack Flight Experiment (SERFE) that was a rack-deployed thermal control system payload on the ISS for two years (2020-2022). The first complete assembly of the xEMU was built as a Design Verification Test (DVT) unit (2022); similar to but more extensive than an Engineering Development Unit (EDU). The xPLSS Backplate serves not only as the structural backbone of the xPLSS and SERFE systems but also contains innovative design features to reduce the: mass, complexity, parts count, number ofseals (and therefore leak potential), and outer dimensions of the entire assembly. This paper provides an overview of these new design features, manufacturing processes, system interfaces, and SERFE/DVT test results of the Backplate as part of the xPLSS/xEMU.

xPLSS↗

Cryogenic Propellant Long-term Storage With Zero Boil-off

Significant boil-off losses of cryogenic propellant storage systems in long-duration space mission applications result in additional propellant and large tanks. The zero boil-off (ZBO) concept consists of an active cryo-cooling system integrated with traditional passive thermal insulation. The potential mass reductions with the ZBO concept are Substantial; therefore, further exploration through technology programs has been initiated within NASA. A large-scale demonstration of the ZBO concept has been devised utilizing the Marshall Space Flight Center (MSFC) Multipurpose Hydrogen Test Bed (MHTB) along with a cryo-cooler unit. The cryo-cooler with the MHTB and spraybar recirculation/mixer system in a manner that enables thermal energy removal at a rate that equals the total tank heat leak. The liquid hydrogen is withdrawn from the tank, passed through a heat exchanger, and then the chilled liquid is sprayed back into the tank through a spraybar. The test series will be performed over a 30-40 day period. Tests will be conducted at multiple fill levels and various mixer operational cycles to demonstrate concept viability and to provide benchmark data to be used in analytical model development. In this paper. analytical models for heat flows through the MHTB tank, cryo-cooler performance. and spraybar performance will be presented.

Hedayat, A.↗

Impact damage resistance of carbon/epoxy composite tubes for the DC-XA liquid hydrogen feedline

Low-velocity impacts were inflicted upon two elbow sections of carbon/epoxy feedline that are to be a part of the Delta Clipper-XA flight vehicle. A soap-based liquid leak detector solution was used to inspect the impact sites for leaks of pressurized gas that was pumped into the tube. Visual surface damage was noted and recorded for each impact site. After impact testing of each of the two sections of tubes was completed, the damage zones were disected from the tube and cross sectioned through the impact site. These specimens were polished after potting them in epoxy and were examined for microcracking using a fluorescent dye penetrant technique. The results showed that nonvisible damage could cause microcracking, thereby resulting in leaks through the tube wall.

Nettles, A. T.↗

Low-heat-leak current leads for intermittent use

The paper reports on the development of current leads for an orbiting superconducting magnetic spectrometer that were required to achieve a zero-current heat leak of 0.03 W with a total coolant flow rate as low as 0.011 g/sec cooling only the coldest third of the length of a lead. Analysis of heat flow phenomena in an insulated current lead in thermal contact with cryogenic gas flow is given for prediction of lead performance. A basic lead design was then tested and modified by such techniques as tapering, adding superconducting sections, and operating above the optimum current, until a lead satisfying the low-leak requirements was obtained. Operating the insulated leads at well above their optimum current for short periods at high mass flow is possible, and instability behavior is predictable.

Smoot, G. F.↗

Faster Test for Cable Seals

Vacuum-assisted immersion test is much faster than conventional atmospheric immersion tests of cable seals. Vacuum speeds removal of air, allowing its replacement by conductive salt solution in leaking specimens. Previously, 24-hour immersion was necessary to assure displacement of trapped air. Improved method takes only 10 minutes.

Shephard, A. T.↗

Study of the Thermal Physical Properties of Insulating Materials in A Titan Environment

Dragonfly is a planned rotorcraft mission that NASA/APL will be sending to Saturn’s moon Titan to study its chemistry. The Dragonfly Mass Spectrometer (DraMS) is a mass spectrometer that is being developed to identify different kinds of organic material that comprises Titan’s surface. The Cryogenic engineering team on DraMS is developing and interface between the room temperature rotorcraft body and the near-cryogenic temperatures of an onboard sample chamber, while minimizing the thermal leak to the Titan environment. As part of design process, the Cryogenic team has built a conductivity test rig for testing the thermophysical properties of candidate insulators, which includes Rohacell 31HF and hollowed 3D printed PEEK structures, at simulated Titan environmental conditions.

Thermal Conductivity↗

Test Analysis Correlation of the Single Stringer Bending Tests for the Space Shuttle ET-137 Intertank Stringer Crack Investigation

On November 5, 2010, Space Shuttle mission STS-133 was scrubbed due to a hydrogen leak at the Ground Umbilical Carrier Plate (GUCP). After the scrub, a crack in the foam thermal protection system (TPS) was observed on the External Tank (ET) near the interface between the liquid oxygen (LOX) tank and the Intertank. When the damaged foam was removed, two 9-in. long cracks were found on the feet of Intertank stringer S7-2, and the stringer failure was the cause of the TPS crack. An investigation was conducted to determine the root cause of the cracks, establish a remedy/repair for the stringers, and provide flight rationale for the damaged tank, ET-137. The Space Transportation System (STS) Super Lightweight ET (SLWT) is comprised of two propellant tanks (an aft liquid hydrogen (LH2) tank and a forward LOX tank) and an Intertank. The Intertank serves as the structural connection between the two propellant tanks and also functions to receive and distribute all thrust loads from the solid rocket boosters . The Intertank is a stiffened cylinder structure consisting of eight mechanically joined panels (two integrally-stiffened, machined thrust panels to react the booster loads and six stringer-stiffened skin panels). There are one main ring frame, four intermediate ring frames, and forward and aft flange chords that mate to the respective propellant tanks.. The skin/stringer panels utilize external hat-section stringers that are mechanically attached with rivets along most of their length and with specialty fasteners, such as GP Lockbolts and Hi-Loks, at the forward and aft ends where the stringers attach to the flange chords. During the STS-133 Intertank stringer crack investigation, cracks were found on a total of five stringers. All of the cracks were at the LOX end, in the feet of the stringers, and near the forward fasteners (GP Lockbolts). Video of tanking for the November 5 launch attempt was used to determine that the TPS failure, and thus the stringer failure, occurred as the LOX liquid level crossed the LOX tank / Intertank interface ring frame. Hence, cryogenically-induced displacements were suspected as a contributing cause of the stringer cracks. To study the behavior of Intertank stringers subjected to similar displacements, static load tests of individual stringers, colloquially known as "single stringer bending tests" were performed. Approximately thirty stringers were tested, many of which were cut from the partially completed Intertank for what would have been ET-139. In addition to the tests, finite element (FE) analyses of the test configuration were also performed. In this paper, the FE analyses and test-analysis correlation for stringer test S6-8 are presented. Stringer S6-8 is a "short chord" configuration with no doubler panels.

Phillips, Dawn R.↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

Structural Dynamic Assessment of the GN2 Piping System for NASA's New and Powerful Reverberant Acoustic Test Facility

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has led the design and build of the new world-class vibroacoustic test capabilities at the NASA GRC's Plum Brook Station in Sandusky, Ohio, USA from 2007 to 2011. SAIC-Benham has completed construction of a new reverberant acoustic test facility to support the future testing needs of NASA's space exploration program and commercial customers. The large Reverberant Acoustic Test Facility (RATF) is approximately 101,000 cubic feet in volume and was designed to operate at a maximum empty chamber acoustic overall sound pressure level (OASPL) of 163 dB. This combination of size and acoustic power is unprecedented amongst the world s known active reverberant acoustic test facilities. Initial checkout acoustic testing was performed on March 2011 by SAIC-Benham at test levels up to 161 dB OASPL. During testing, several branches of the gaseous nitrogen (GN2) piping system, which supply the fluid to the noise generating acoustic modulators, failed at their T-junctions connecting the 12 in. supply line to their respective 4 in. branch lines. The problem was initially detected when the oxygen sensors in the horn room indicated a lower than expected oxygen level from which was inferred GN2 leaks in the piping system. In subsequent follow up inspections, cracks were identified in the failed T-junction connections through non-destructive evaluation testing. Through structural dynamic modeling of the piping system, the root cause of the T-junction connection failures was determined. The structural dynamic assessment identified several possible corrective design improvements to the horn room piping system. The effectiveness of the chosen design repairs were subsequently evaluated in September 2011 during acoustic verification testing to 161 dB OASPL.

McNelis, Mark E.↗

Apollo 14 mission food preparation unit leakage

A bubble of water collected on the delivery probe of the food preparation unit after hot water was dispensed by the Apollo 14 crew. Postflight tests showed that dimensional interference between the cylinder and the piston at hot water temperatures produced the apparent leak by causing erratic and slow stroke time of the valve assembly.

Source record↗