Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A Progress Report for a 44-month Aging Study on Nitroplasticizer (NP) Stability - Summary of DFT and FTIR Results

In the past few years, a 44-month long aging experiment was conducted under various aging conditions. The properties of aged nitroplasticizer (NP) samples were analyzed using Fourier transform infrared spectroscopy, Karl Fischer (KF) titration, thermogravimetric analysis (TGA), liquid chromatography tandem quadrupole time of flight mass spectrometry (LC/QTOF), and ion chromatography (IC). In this progress report, some FTIR results are documented and discussed. On the theoretical front, density functional theory (DFT) calculations were carried out. Some DFT results are discussed as well.

36 MATERIALS SCIENCE↗

Germplasm cryopreservation of macroalgae for aquaculture breeding and natural resource conservation: A review

The expansion of the global macroalgal aquaculture and climate change creates the need for germplasm preservation of valuable aquaculture strains and maintenance of natural biodiversity. Compared to the large number of studies in fish and shellfish species, relative few studies have been conducted on the macroalgal germplasm cryopreservation. The first cryopreservation of macroalgae to –75 °C was reported on Neopyropia tenera (formerly called Porphyra tenera) in 1964. To date, a total of 34 studies reported germplasm cryopreservation in 33 species, including Chlorophyta (7 species), Ochrophyta (14 species), and Rhodophyta (12 species). Here, the goal of this review was to summarize the published studies on macroalgal germplasm cryopreservation, compare the reported protocols for the cryopreservation process, and identify the factors affecting post-thaw viability. Overall, macroalgal germplasm cryopreservation included haploid or diploid thalli, spores, and gametes. Cryotubes (1.5-ml or 2-ml) have been widely used to package germplasm samples for cooling and storage in most studies, and the 0.5-ml straws and 5-ml cryotubes have been used in several studies. Two approaches (programmable controlled cooling and vitrification) were employed for macroalgal germplasm cryopreservation. A two-step programmable controlled cooling (e.g., from initial culture temperature to a frozen temperature, such as –40 °C, and then directly plunging into liquid nitrogen at –196 °C) was determined to be an effective cooling strategy. Vitrification, a super rapid cooling for a sample to form non-crystalline amorphous solid, was applied on macroalgal germplasm cryopreservation with sample encapsulation and dehydration. Survival of post-thaw samples varied significantly in different studies. Based on research updates, recommendations are made for future research. It is expected that this review can serve as a foundation for future germplasm banking of macroalgae for aquaculture and biodiversity preservation.

59 BASIC BIOLOGICAL SCIENCES↗

Compositional analysis of organosolv poplar lignin by using high-performance liquid chromatography/high-resolution multi-stage tandem mass spectrometry

Organosolv treatment is an efficient and environmentally friendly process to degrade lignin into small compounds. The capability of characterizing the individual compounds in the complex mixtures formed upon organosolv treatment is essential for the optimization of the further lignin conversion processes and for the rational genetic engineering of plants used to produce lignin in order to improve lignin properties. In this study, an organosolv poplar lignin sample was initially analyzed by high-resolution mass spectrometry coupled with negative-ion mode electrospray ionization ((-)ESI HRMS). Lignin monomers and dimers were found to constitute the majority of the compounds in the organosolv lignin sample. Larger lignin oligomers, such as trimers and tetramers, and some not lignin-related compounds, were also detected. A high-performance liquid chromatograph/linear quadrupole ion trap/orbitrap mass spectrometer capable of multi-stage high-resolution tandem mass spectrometry experiments (HRMS n ), equipped with an (-)ESI source (HPLC/(-)ESI HRMS n ), was employed to separate the unknown compounds in the organosolv mixture and to obtain structural information for the deprotonated compounds via collision-activated dissociation (CAD) HRMS n experiments. To improve the understanding of the CAD behavior of deprotonated lignin-related compounds, 16 deprotonated model compounds with different functionalities and linkage types were examined. This approach enabled the assignment of likely structures for several lignin monomers, dimers, trimers, and tetramers, and some not lignin-related compounds, most likely fatty acids. Based on the proposed structures, compounds in the organosolv lignin sample contain β-O-4, 5–5, β-5, and possibly also 4-O-5 linkages. Most compounds contain G- and S-monomeric units although a small amount of H-units were also detected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Whose Gas is it anyway? Differentiating the Source of a Large Soil Vapor Plume beneath Two Adjacent Waste Sites - 20487

DOE contractor CH2M Hill Plateau Remediation Company is currently responsible for conducting groundwater contamination monitoring at several RCRA treatment, storage, and disposal units located on the Hanford Site in Richland, Washington State. The Nonradioactive Dangerous Waste Landfill treatment, storage, and disposal unit presents a distinct groundwater monitoring problem because of a large multi-contaminant soil vapor plume beneath it that is a likely source of low-level volatile organic compound groundwater contamination. Adjacent to Nonradioactive Dangerous Waste Landfill is the Solid Waste Landfill. Volatile organic compounds are inventory components of both the Nonradioactive Dangerous Waste Landfill and the Solid Waste Landfill. Therefore, it is possible that both sites could be contributing to the soil vapor plume. For regulatory purposes, it is important to differentiate which site is the primary contributor of volatile organic compounds to the plume. An approach was developed to identify the primary volatile organic compound source of the soil vapor plume beneath Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. The site conceptual model hypothesis of vapor-phase volatile organic compound transport to the dissolved phase in groundwater was tested by a simple mathematical model of vapor/liquid equilibrium concentrations at the groundwater/air interface. Once it was shown that vapor-phase volatile organic compound transport to groundwater was a valid conceptual model for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill, spatial and statistical methods were used to determine the primary site contributing to the majority of volatile organic compounds to the soil vapor plume. Average groundwater chloroform, tetrachloroethene, and trichloroethene concentrations from Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring network wells were plotted on maps of the facilities and immediate vicinities and compared to soil vapor sampling probe locations. Principal component analysis and mixing ratios were used to identify source contributions of each treatment, storage, and disposal unit to the plume. Results of the vapor/liquid equilibrium concentrations mathematical model showed that transport phenomena outweigh steady-state equilibria. Estimated vapor/liquid equilibrium concentrations were considerably lower than soil vapor measurements. The results indicate that dynamic vadose zone and groundwater factors such as decreased vapor concentrations with depth, vapor dilution from dispersion in the vadose zone, and advective and diffusional volatile organic compound dilution in groundwater result in groundwater volatile organic compound concentrations much less than would be measured under steady-state equilibrium conditions. Site source contribution differentiation by principal component analysis and mixing ratios was inconclusive using actual soil gas data because of the similarity in concentration values in both datasets for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. Similar data populations suggest mixing of the vapor contributions from both sites by dispersion through the soil matrix pore spaces. However, when groundwater volatile organic compound data were compared between the Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring networks, Solid Waste Landfill mean concentrations were higher, suggesting more vapor-phase volatile organic compound transport to groundwater at those locations. Simulated volatile organic compound soil vapor and groundwater datasets created to test the methods developed for this study show that the method can be successful in source differentiation when significantly different datasets are compared. This paper will describe a method of testing a conceptual model for vapor-phase contaminant transport to groundwater and for differentiating site sources of contaminants comprising a mixed-constituent soil vapor plume. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SRS Strategy for Tank 3 Salt Dissolution - Performance and Lessons Learned - 20441

The Savannah River Site (SRS) Tank Farms have 51 underground waste tanks used to store and process liquid nuclear waste materials. There are 4 different tank types, ranging in capacity from 2,840,000 to 4,920,000 L (750,000 to 1,300,000 Gal). Twenty-four of the tanks are older style and do not meet full secondary containment standards. The older style tanks are the initial focus of waste removal efforts for tank closure at SRS. Eight of these twenty-four tanks have completed waste removal and are filled with grout. Prior to salt dissolution, Tank 3 was a dry salt tank that contained 5.06 m (199.3 in) of salt and sludge waste. Additional salt waste was present on cooling coils above the salt layer up to approximately 5.59 m (220 in). Three mixing eductors were installed in Tank 3 to aid in dissolving salt waste in three tank riser access ports. A transfer pump was installed, and the transfer pump suction was located 25.4 cm (10 in) from the tank bottom. Well water was added to the tank through a downcomer until the dry bulk salt was covered with liquid. During the initial fill of Tank 3, approximately 242,000 L (64,000 Gal) of rain water were added from periodic F-Tank Farm (FTF) Catch Tank additions and approximately 17,000 L (4,500 Gal) of well water were added. Following liquid additions to cover the dry bulk salt, well water was added through the three mixing eductors in batches during each stage. Additionally, during the salt dissolution campaigns, the FTF Catch Tank was utilized to add rain water through a downcomer in the center tank riser access port as needed for volume relief in the FTF Catch Tank. Following liquid additions, the water was recirculated (internal to the tank) using the transfer pump, and a sample was pulled to confirm the target specific gravity (SpG) of the dissolved salt solution was achieved. The dissolved salt solution was then transferred to the receipt tank (Tank 7), and the mixing eductors were lowered as close to the new bulk salt layer as possible, to support subsequent dissolution campaigns. While the mixing jets were able to dissolve salt successfully in Tank 3, they did not do so in a completely uniform manner. Throughout dissolution, mounds were discovered under Riser 1, Riser 2, and the Center Riser. The mixing jets dissolved the salt around the edges of the tank well but were not as effective toward the center of the tank. FTF Catch Tank additions through the center tank riser access port downcomer were required to impact the mound under the center tank riser. FTF Catch Tank additions were sporadic as they were dependent on rainfall in the area. Additionally, all mixing jets were rarely able to be lowered to the same elevation, indicating some mounding in the bulk salt layer. Indexing of the mixing jets was also utilized to impact the salt mounds. Overall, Tank 3 salt dissolution was successful as approximately 1,476,000 L (390,000 Gal) of dissolved salt solution was transferred to Tank 7 over six stages. Slightly less than 852,000 L (225,000 Gal) of water were added to Tank 3. The original material balance prediction estimated that the bulk salt level in Tank 3 would be 3.88 m (152.8 in) after six salt dissolution stages. After six stages the actual bulk salt level was 3.38 m (133 in). This paper will discuss the salt removal strategy, each salt dissolution stage, and lessons learned for future salt dissolution. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

New reflections on hard X-ray photon-in/photon-out spectroscopy

Analysis of the electronic structure and local coordination of an element is an important aspect in the study of the chemical and physical properties of materials. This is particularly relevant at the nanoscale where new phases of matter may emerge below a critical size. X-ray emission spectroscopy (XES) at synchrotron radiation sources and free electron lasers has enriched the field of X-ray spectroscopy. Additionally, the spectroscopic techniques derived from the combination of X-ray absorption and emission spectroscopy (XAS–XES), such as resonant inelastic X-ray scattering (RIXS) and high energy resolution fluorescence detected (HERFD) XAS, are an ideal tool for the study of nanomaterials. New installations and beamline upgrades now often include wavelength dispersive instruments for the analysis of the emitted X-rays. With the growing use of XAS–XES, scientists are learning about the possibilities and pitfalls. We discuss some experimental aspects, assess the feasibility of measuring weak fluorescence lines in dilute, radiation sensitive samples, and present new experimental approaches for studying magnetic properties of colloidal nanoparticles directly in the liquid phase.

47 OTHER INSTRUMENTATION↗

Myalgic encephalomyelitis/chronic fatigue syndrome and fibromyalgia are indistinguishable by their cerebrospinal fluid proteomes

Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS) and fibromyalgia have overlapping neurologic symptoms particularly disabling fatigue. This has given rise to the question whether they are distinct central nervous system (CNS) entities or is one an extension of the other. To investigate this, we used unbiased quantitative mass spectrometry-based proteomics to examine the most proximal fluid to the brain, cerebrospinal fluid (CSF). This was to ascertain if the proteome profile of one was the same or different from the other. We examined two separate groups of ME/CFS, one with (n = 15) and one without (n = 15) fibromyalgia. We quantified a total of 2083 proteins using immunoaffinity depletion, tandem mass tag isobaric labelling and offline two-dimensional liquid chromatography coupled to tandem mass spectrometry, including 1789 that were quantified in all the CSF samples. ANOVA analysis did not yield any proteins with an adjusted p value <.05. This supports the notion that ME/CFS and fibromyalgia as currently defined are not distinct entities.

60 APPLIED LIFE SCIENCES↗

Low-cost production method for fluorescent particles for liquid flow velocimetry applications

Abstract In this Technical Note, we present a simple and low-cost production method for fluorescent particles perfectly suitable for velocimetry applications. We leverage the unique ability of Nile Red (NR) fluorophores to adsorb on the polymer surface and/or embed itself in between polymeric chains. The laboratory procedure to dye polyamide particles with NR and monetary advantages over commercially available fluorescent particles is outlined. Subsequently, the fluorescence behavior of the dyed particles is tested under a laser illumination source in polar and non-polar liquids. The distinct advantage of the emission spectrum of NR-dyed particles is demonstrated with sample test results.

42 ENGINEERING↗

Identification of Non-Fermi Liquid Physics in a Quantum Critical Metal via Quantum Loop Topography

Non-Fermi liquid physics is ubiquitous in strongly correlated metals, manifesting itself in anomalous transport properties, such as a $\textit{T}$-linear resistivity in experiments. However, its theoretical understanding in terms of microscopic models is lacking, despite decades of conceptual work and attempted numerical simulations. In this work, we demonstrate that a combination of sign-problem-free quantum Monte Carlo sampling and quantum loop topography, a physics-inspired machine-learning approach, can map out the emergence of non-Fermi liquid physics in the vicinity of a quantum critical point (QCP) with little prior knowledge. Using only three parameter points for training the underlying neural network, we are able to robustly identify a stable non-Fermi liquid regime tracing the fans of metallic QCPs at the onset of both spin-density wave and nematic order. In particular, we establish for the first time that a spin-density wave QCP commands a wide fan of non-Fermi liquid region that funnels into the quantum critical point. Our study thereby provides an important proof-of-principle example that new physics can be detected via unbiased machine-learning approaches.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Equation of State Measurements on Iron Near the Melting Curve at Planetary Core Conditions by Shock and Ramp Compressions

The outer core of the Earth is composed primarily of liquid iron, and the inner core boundary is governed by the intersection of the melt line and the geotherm. While there are many studies on the thermodynamic equation of state for solid iron, the equation of state of liquid iron is relatively unexplored. In this work, we use dynamic compression to diagnose the high-pressure liquid equation of state of iron by utilizing the shock-ramp capability at Sandia National Laboratories’ Z-Machine. This technique enables measurements of material states off the Hugoniot by initially shocking samples and subsequently driving a further, shockless compression. Planetary studies benefit greatly from isentropic, off-Hugoniot experiments since they can cover pressure-temperature (P-T) conditions that are close to adiabatic profiles found in planetary interiors. We used this method to drive iron to P-T conditions similar to those of the Earth’s outer-inner core boundary, along an elevated-temperature isentrope in the liquid from 275 GPa to 400 GPa. We derive the equation of state using a hybrid backward integration – forward Lagrangian technique on particle velocity traces to determine the pressure-density history of the sample. Our results are in excellent agreement with SESAME 92141, a previously published equation of state table. With our data and previous experimental data on liquid iron we provide new information on the iron melting line and derive new parameters for a Vinet-based equation of state. The table and our parameterized equation of state are applied to provide an updated means of modeling the pressure, mass, and density of liquid iron cores in exoplanetary interiors.

58 GEOSCIENCES↗

Characterizing Surface Ice-Philicity Using Molecular Simulations and Enhanced Sampling

The formation of ice, which plays an important role in diverse contexts ranging from cryopreservation to atmospheric science, is often mediated by solid surfaces. Although surfaces that interact favorably with ice (relative to liquid water) can facilitate ice formation by lowering nucleation barriers, the molecular characteristics that confer ice-philicity to a surface are complex and incompletely understood. To address this challenge, here we introduce a robust and computationally efficient method for characterizing surface ice-philicity that combines molecular simulations and enhanced sampling techniques to quantify the free energetic cost of increasing surface–ice contact at the expense of surface–water contact. Using this method to characterize the ice-philicity of a family of model surfaces that are lattice matched with ice but vary in their polarity, we find that the nonpolar surfaces are moderately ice-phobic, whereas the polar surfaces are highly ice-philic. In contrast, for surfaces that display no complementarity to the ice lattice, we find that ice-philicity is independent of surface polarity and that both nonpolar and polar surfaces are moderately ice-phobic. Furthermore, our work thus provides a prescription for quantitatively characterizing surface ice-philicity and sheds light on how ice-philicity is influenced by lattice matching and polarity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis, identification and confirmation of synthetic opioids using chloroformate chemistry: Retrospective detection of fentanyl and acetylfentanyl in urine and plasma samples by EI-GC-MS and HR-LC-MS

Electron Impact Gas Chromatography-Mass Spectrometry (EI-GC-MS) and High Resolution Liquid Chromatography-Mass Spectrometry (HR-LC-MS) have been used in the analysis of products arising from the trichloroethoxycarbonylation of fentanyl and acetylfentanyl in urine and plasma matrices. The method involves the initial extraction of both synthetic opioids separately from the matrices followed by detection of the unique products that arise from their reaction with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl), namely Troc-norfentanyl and Troc-noracetylfentanyl. The optimized protocol was successfully evaluated for its efficacy at detecting these species formed from fentanyl and acetylfentanyl when present at low and high levels in urine (fentanyl: 5 and 10 ng/mL and acetylfentanyl: 20 and 100 ng/mL) and plasma (fentanyl: 10 and 20 ng/mL and acetylfentanyl: 50 and 200 ng/mL), values that reflect levels reported in overdose victims. The HR-LC-MS method’s LOQ (limit of quantitation) for the Troc-norfentanyl and Troc-noracetylfentanyl products was determined to be ~10 ng/mL for both species. Even though the superiority in the detection of these species by HR-LC-MS over EI-GC-MS, the latter method proved to be important in the detection of the second product from the reaction, namely 2-phenylethyl chloride that is crucial in the determination of the original opioid. This observation highlights the importance of using complimentary analytical techniques in the analysis of a sample, whether biological or environmental in nature. The method herein serves as a complementary, qualitative confirmation for the presence of a fentanyl in collected urine, plasma and by extension other biological samples amenable to the common extraction procedures described for opioid analysis. More importantly, the method’s main strength comes from its ability to react with unknown fentanyls to yield products that can be not only detected by EI-GC-MS and HR-LC-MS but can then be used to retrospectively identify an unknown fentanyl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

What Are the Similarities and Differences in Marine Boundary Layer Cloud and Drizzle Microphysical Properties During the ACE–ENA and MARCUS Field Campaigns?

This study compares macrophysical and microphysical properties of single-layered, liquid-dominant MBL clouds from the Measurements of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) (above 60°S) and the ARM East North Atlantic (ENA) site during the Aerosol and Cloud Experiments in Eastern North Atlantic (ACE-ENA) field campaign. A total of 1,136 (16.5% of clouds) and 6,034 5-min cloud samples are selected from MARCUS and ARM ENA in this study. MARCUS clouds have higher cloud-top heights, thicker cloud layers, larger liquid water path, and colder cloud temperatures than ENA. Thinner, warmer MBL clouds at ENA can contain higher layer-mean liquid water content due to higher cloud and ocean surface temperatures along with greater precipitable water vapor (PWV). MARCUS has a higher drizzle frequency rate (71.8%) than ENA (45.1%). Retrieved cloud and drizzle microphysical properties from each field campaign show key differences. MARCUS clouds feature smaller cloud droplets, whereas ENA clouds have larger cloud droplets, especially at the upper region of the cloud. From cloud top to cloud base, drizzle drop sizes increase while number concentrations decrease. Drizzle drop radius and number concentration decrease from cloud base to drizzle base due to net evaporation, and MARCUS' lower specific humidity leads to a higher drizzle base than ENA. In conclusion, the broader surface pressure and lower tropospheric stability (LTS) distributions during MARCUS have demonstrated that there are different synoptic patterns for selected cases during MARCUS with less PWV, while ENA is dominated by high pressure systems with nearly doubled PWV.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Ionic Mercury Species in SRR Samples Measured by SRNL and Eurofins FGS

Savannah River Remediation (SRR) requested the development of mercury speciation capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins Frontier Global Sciences (FGS). This document reports on this method development work performed at SRNL as well as the comparative analyses conducted between the two laboratories. Development, optimization, and validation were undertaken at SRNL to produce a method for the species-specific analysis of ionic mercury. This method was developed as a secondary step to an existing method, L16.1-ADS-1579 Purgeable Mercury Cold Vapor Atomic Fluorescence Spectrophotometry. As such, much of the development and validation were performed in service of development of L16.1-ADS-1579. Six samples, representing two consecutive quarterly Tank 50 batches, were tested for ionic mercury by SRNL-AD and Eurofins FGS. The mean values reported by each lab for ionic mercury differed by less than one standard deviation, therefore the values reported by both labs were considered to be in agreement. SRNL-AD reported values for the six samples that differed by -5.56 mean percent, relative to Eurofins FGS. Together with comparable quality control data reported by each laboratory, these data represent a high level of agreement among both laboratories. With a viable method for ionic mercury that matches the data quality provided by outside commercial laboratories, SRNL-AD has demonstrated competency in measuring methylmercury, ethylmercury, total mercury, soluble & particulate mercury, purgeable mercury, and ionic mercury species in a variety of radioactive tank samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Glycolate in Radioactive Waste by Ion Chromatography (IC) and Proton Nuclear Magnetic Resonance (H NMR)

Here, in preparation for implementing the Nitric-Glycolic (NG) acid flowsheet for the Savannah River Site (SRS) Liquid Waste System (LWS), analytical methods for determining glycolate at low concentration, below 20 mg/L in radioactive samples, were developed to support system management and safety. To accommodate the wide range of LWS matrix conditions, two alternative methods were developed, refined, and demonstrated for glycolate analysis in radioactive waste samples: ion chromatography (IC) and a proton nuclear magnetic resonance (H NMR). Investigators validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. The deployed IC method is applicable in low to moderate ionic strength samples and requires sample pretreatment using a Dionex OnGuard II H + cartridge. The deployed H NMR method is more labor intensive but provides options for a broader range of matrices. Based on the results, high quality glycolate analysis of the Defense Waste Processing Facility (DWPF) condensate in Tank 22 is feasible by IC down to approximately 12 mg/L. Using H NMR, glycolate may be determined to 8 mg/L or lower depending on the run time with the potential for broader applicability of the method to higher ionic strength conditions in other tanks of the SRS LWS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Quantitative phase imaging by gradient retardance optical microscopy

Abstract Quantitative phase imaging (QPI) has become a vital tool in bioimaging, offering precise measurements of wavefront distortion and, thus, of key cellular metabolism metrics, such as dry mass and density. However, only a few QPI applications have been demonstrated in optically thick specimens, where scattering increases background and reduces contrast. Building upon the concept of structured illumination interferometry, we introduce Gradient Retardance Optical Microscopy (GROM) for QPI of both thin and thick samples. GROM transforms any standard Differential Interference Contrast (DIC) microscope into a QPI platform by incorporating a liquid crystal retarder into the illumination path, enabling independent phase-shifting of the DIC microscope's sheared beams. GROM greatly simplifies related configurations, reduces costs, and eradicates energy losses in parallel imaging modalities, such as fluorescence. We successfully tested GROM on a diverse range of specimens, from microbes and red blood cells to optically thick (~ 300 μm) plant roots without fixation or clearing.

47 OTHER INSTRUMENTATION↗

Equation of State of CO 2 Shock Compressed to 1 TPa

Equation-of-state (pressure, density, temperature, internal energy) and reflectivity measurements on shock-compressed CO 2 at and above the insulating-to-conducting transition reveal new insight into the chemistry of simple molecular systems in the warm-dense-matter regime. CO 2 samples were precompressed in diamond-anvil cells to tune the initial densities from 1.35 g/cm 3 (liquid) to 1.74 g/cm 3 (solid) at room temperature and were then shock compressed up to 1 TPa and 93 000 K. Lastly, variation in initial density was leveraged to infer thermodynamic derivatives including specific heat and Gruneisen coefficient, exposing a complex bonded and moderately ionized state at the most extreme conditions studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗