Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

SU-F-I-67: Neurometabolic Effect Induced by Repeated Exposure to Dizocilpine On Prefrontal Cortex of Schizophrenic Animal Model Using In Vivo Proton Magnetic Resonance Spectroscopy at 9.4 T

Purpose: Repeated exposure of dizocilpine (MK-801) can provide a pathophysiological model for progressive development of schizophrenia. In vivo proton magnetic resonance spectroscopy ({sup 1}H MRS) was widely used for non-invasive measurement of neurometabolites, and assessment of disease-induced neurometabolic alterations. The purpose of this study was to investigate neurometabolic alteration in prefrontal cortex (PFC) with respect to progression (from first-episode to chronic stage) of schizophrenia by using in vivo {sup 1}H MRS. Methods: We used high-field {sup 1}H MRS to investigate the neurometabolic alteration in the PFC region of the rats (N = 13) by comparing before and after 6 day of MK-801 (0.5 mg/kg) treatment. A point-resolved spectroscopy (PRESS) sequence was used to obtain spectra in a 22.5 µL of volume of interest carefully located in PFC region with parameters like follow; repetition time, 5000ms; echo time (TE), 13.4 ms; averages = 256. Another experiment group (N = 11) were conducted behavior test by recording the behavior for 20 min. Results: All the rats showed hyperlocomotion, stereotyped behaviors before initiation of MRS. Significantly increased level (N = 7, p < 0.05) of N-acetylasrparate (NAA), glutamate (Glu), taurine and decreased level (N = 6, p < 0.05) of NAA, Glu and phosphocreatine were observed between baseline and day 6. Both metabolic alterations are consistent with results of first-episode and chronic schizophrenia respectively. Conclusion: From our findings, the repeated MK-801 model could be a pathophysiological model which can provide an insight into the transition from first-episode to chronic stage. This is first time to investigate effects of repeated MK-801 using high-field in vivo 1H MRS. We expect our findings can contribute to combining previous diverging results into one pathophysiological interpretation, which can postulate the origin of diverging results to the progression of schizophrenia.

60 APPLIED LIFE SCIENCES↗

Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamical cancellation of pulse-induced transients in a metallic shielded room for ultra-low-field magnetic resonance imaging

Pulse-induced transients such as eddy currents can cause problems in measurement techniques where a signal is acquired after an applied preparatory pulse. In ultra-low-field magnetic resonance imaging, performed in magnetic fields typically of the order of 100 μT, the signal-to-noise ratio is enhanced in part by prepolarizing the proton spins with a pulse of much larger magnetic field and in part by detecting the signal with a Superconducting QUantum Interference Device (SQUID). The pulse turn-off, however, can induce large eddy currents in the shielded room, producing an inhomogeneous magnetic-field transient that both seriously distorts the spin dynamics and exceeds the range of the SQUID readout. It is essential to reduce this transient substantially before image acquisition. We introduce dynamical cancellation (DynaCan), a technique in which a precisely designed current waveform is applied to a separate coil during the later part and turn off of the polarizing pulse. This waveform, which bears no resemblance to the polarizing pulse, is designed to drive the eddy currents to zero at the precise moment that the polarizing field becomes zero. We present the theory used to optimize the waveform using a detailed computational model with corrections from measured magnetic-field transients. SQUID-based measurements with DynaCan demonstrate a cancellation of 99%. Dynamical cancellation has the great advantage that, for a given system, the cancellation accuracy can be optimized in software. This technique can be applied to both metal and high-permeability alloy shielded rooms, and even to transients other than eddy currents.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward Magnetic Resonance–Only Simulation: Segmentation of Bone in MR for Radiation Therapy Verification of the Head

Purpose: To develop a practical method to localize bones in magnetic resonance (MR) images, to create “computed tomography–like” MR images (ctMRI) that could be used for radiation therapy verification, and to generate MR-based digitally reconstructed radiographs (DRR). Methods and Materials: Using T1-weighted MR images, an air mask was derived from the manual contouring of all airways within the head and neck region using axial images at 6 anatomic levels. Compact bone, spongy bone, and soft tissue masks were then automatically generated using the statistical data derived from MR intensities and the air mask. ctMRI were then generated by mapping the MR intensities of the voxels within these masks into the CT number ranges of corresponding tissues. MR-based DRRs created from ctMRI were quantitatively evaluated using the co-registered MR and CT head images of 20 stereotactic radiosurgery patients. Ten anatomical points, positioned on the skull segmented using a threshold of 300 HU, in CT and ctMRI, were used to determine the differences in distance between MR-based DRRs and CT-based DRRs, and to evaluate the geometric accuracy of ctMRI and MR-based DRRs. Results: The bony structures were identified on ctMRI and were visible in the MR-based DRRs. From the 20 patient cases, the mean geometric difference and standard deviation between the 10 anatomical points on MR-based and CT-based DRRs was −0.05 ± 0.85 mm, respectively. This included uncertainty in image fusion. The maximum distance difference was 1.88 mm. Conclusions: A practical method was developed to segment bone from MR images. The ctMRI created can be used for radiation treatment verification when MR-only simulation is performed. MR-based DRRs can be used in place of CT-based DRRs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High resolution magnetic resonance imaging of the calcaneus: age-related changes in trabecular structure and comparison with dual X-ray absorptiometry measurements

A high-resolution magnetic resonance imaging (MRI) protocol, together with specialized image processing techniques, was applied to the quantitative measurement of age-related changes in calcaneal trabecular structure. The reproducibility of the technique was assessed and the annual rates of change for several trabecular structure parameters were measured. The MR-derived trabecular parameters were compared with calcaneal bone mineral density (BMD), measured by dual X-ray absorptiometry (DXA) in the same subjects. Sagittal MR images were acquired at 1.5 T in 23 healthy women (mean age: 49.3 +/- 16.6 [SD]), using a three-dimensional gradient echo sequence. Image analysis procedures included internal gray-scale calibration, bone and marrow segmentation, and run-length methods. Three trabecular structure parameters, apparent bone volume (ABV/TV), intercept thickness (I.Th), and intercept separation (I.Sp) were calculated from the MR images. The short- and long-term precision errors (mean %CV) of these measured parameters were in the ranges 1-2% and 3-6%, respectively. Linear regression of the trabecular structure parameters vs. age showed significant correlation: ABV/TV (r2 = 33.7%, P < 0.0037), I.Th (r2 = 26.6%, P < 0.0118), I.Sp (r2 = 28.9%, P < 0.0081). These trends with age were also expressed as annual rates of change: ABV/TV (-0.52%/year), I.Th (-0.33%/year), and I.Sp (0.59%/year). Linear regression analysis also showed significant correlation between the MR-derived trabecular structure parameters and calcaneal BMD values. Although a larger group of subjects is needed to better define the age-related changes in trabecular structure parameters and their relation to BMD, these preliminary results demonstrate that high-resolution MRI may potentially be useful for the quantitative assessment of trabecular structure.

NASA Discipline Number 26-10↗

Spin counting in electrically detected magnetic resonance via low-field defect state mixing

The work herein describes a method that allows one to measure paramagnetic defect densities in semiconductor and insulator based devices with electrically detected magnetic resonance (EDMR). The method is based upon the mixing of defect states which results from the dipolar coupling of paramagnetic sites at low magnetic fields. We demonstrate the measurement method with spin dependent tunneling in thin film dielectrics; however, the method should be equally applicable to paramagnetic defect density measurements in semiconductors via the more commonly utilized EDMR technique called spin dependent recombination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In-depth investigation of large axial magnetic anisotropy in monometallic 3d complexes using frequency domain magnetic resonance and ab initio methods: a study of trigonal bipyramidal Co( II )

The magnetic properties of 3d monometallic complexes can be tuned through geometric control, owing to their synthetic accessibility and relative structural simplicity. Monodentate ligands offer great potential for fine-tuning the coordination environment to engineer both the axial and rhombic zero-field splitting (ZFS) parameters. In [CoCl 3 (DABCO)(HDABCO)] ( 1 ), the trigonal bipyramidal Co( II ) centre has two bulky axial ligands and three equatorial chloride ligands. An in-depth experimental and theoretical study of 1 reveals a large easy-plane magnetic anisotropy (+ve D ) with a negligible rhombic zero-field splitting ( E ) due to the strict axial symmetry imposed by the C 3 symmetric ligand and trigonal space group. The large easy-plane magnetic anisotropy ( D = +44.5 cm -1 ) is directly deduced using high-field EPR and frequency-domain magnetic resonance (FDMR) studies. Ab initio calculations reveal a large positive contribution to the D term arising from ground state/excited state mixing of the 4 E" states at ~4085 cm -1 and a minor contribution from the spin–flip transition as well. The nature of the slow relaxation in 1 is elucidated through analysis of the rates of relaxation of magnetisation, taking into account Raman and direct spin–lattice relaxation processes and Quantum Tunnelling of the Magnetisation (QTM). The terms relating to the direct process and QTM were found based on the fit of the field-dependence of $τ$ at 2 K. Subsequently, these were used as fixed parameters in the fit of the temperature-dependence of $τ$ to obtain the Raman terms. This experimental–theoretical investigation provides further insight into the power of FDMR and ab initio methods for the thorough investigation of magnetic anisotropy. Thus, these results contribute to design criteria for high magnetic anisotropy systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relativistic nuclear magnetic resonance J-coupling with ultrasoft pseudopotentials and the zeroth-order regular approximation

We present a method for the first-principles calculation of nuclear magnetic resonance (NMR) J-coupling in extended systems using state-of-the-art ultrasoft pseudopotentials and including scalar-relativistic effects. The use of ultrasoft pseudopotentials is allowed by extending the projector augmented wave (PAW) method of Joyce et al. [J. Chem. Phys. 127, 204107 (2007)]. We benchmark it against existing local-orbital quantum chemical calculations and experiments for small molecules containing light elements, with good agreement. Scalar-relativistic effects are included at the zeroth-order regular approximation level of theory and benchmarked against existing local-orbital quantum chemical calculations and experiments for a number of small molecules containing the heavy row six elements W, Pt, Hg, Tl, and Pb, with good agreement. Finally, {sup 1}J(P-Ag) and {sup 2}J(P-Ag-P) couplings are calculated in some larger molecular crystals and compared against solid-state NMR experiments. Some remarks are also made as to improving the numerical stability of dipole perturbations using PAW.

97 MATHEMATICS AND COMPUTING↗

Dedicated Magnetic Resonance Imaging in the Radiotherapy Clinic

Purpose: To introduce a novel technology arrangement in an integrated environment and outline the logistics model needed to incorporate dedicated magnetic resonance (MR) imaging in the radiotherapy workflow. An initial attempt was made to analyze the value and feasibility of MR-only imaging compared to computed tomography (CT) imaging, testing the assumption that MR is a better choice for target and healthy tissue delineation in radiotherapy. Methods and Materials: A 1.5-T MR unit with a 70-cm-bore size was installed close to a linear accelerator, and a special trolley was developed for transporting patients who were fixated in advance between the MR unit and the accelerator. New MR-based workflow procedures were developed and evaluated. Results: MR-only treatment planning has been facilitated, thus avoiding all registration errors between CT and MR scans, but several new aspects of MR imaging must be considered. Electron density information must be obtained by other methods. Generation of digitally reconstructed radiographs (DRR) for x-ray setup verification is not straight forward, and reliable corrections of geometrical distortions must be applied. The feasibility of MR imaging virtual simulation has been demonstrated, but a key challenge to overcome is correct determination of the skeleton, which is often needed for the traditional approach of beam modeling. The trolley solution allows for a highly precise setup for soft tissue tumors without the invasive handling of radiopaque markers. Conclusions: The new logistics model with an integrated MR unit is efficient and will allow for improved tumor definition and geometrical precision without a significant loss of dosimetric accuracy. The most significant development needed is improved bone imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clustering Nuclear Magnetic Resonance: Machine learning assistive rapid two‐dimensional relaxometry mapping

Abstract Low‐field nuclear magnetic resonance (NMR) relaxometry is an attractive approach from point‐of‐care testing medical diagnosis to in situ oil‐gas exploration. One of the problems, however, is the inherently long relaxation time of the (liquid) samples, (and hence low signal‐to‐noise ratio) which causes unnecessarily long repetition time. In this work, a new class of methodology is presented for rapid and accurate object classification using NMR relaxometry with the aid of machine learning. It is demonstrated that the sensitivity and specificity of the classification is substantially improved with higher order of (pseudo)‐dimensionality (e.g., 2D‐ or multi‐dimensional). This new methodology (termed as ‘Clustering NMR’) may be extremely useful for rapid and accurate object classification (in less than a minute) using low‐field NMR.

Peng, Weng Kung↗

Assessment of acute myocarditis by cardiac magnetic resonance imaging: Comparison of qualitative and quantitative analysis methods

Background: To compare cardiac magnetic resonance (CMR) qualitative and quantitative analysis methods for the noninvasive assessment of myocardial inflammation in patients with suspected acute myocarditis (AM). Methods: A total of 61 patients with suspected AM underwent coronary angiography and CMR. Qualitative analysis was performed applying Lake-Louise Criteria (LLC), followed by quantitative analysis based on the evaluation of edema ratio (ER) and global relative enhancement (RE). Diagnostic performance was assessed for each method by measuring the area under the curves (AUC) of the receiver operating characteristic analyses. The final diagnosis of AM was based on symptoms and signs suggestive of cardiac disease, evidence of myocardial injury as defined by electrocardiogram changes, elevated troponin I, exclusion of coronary artery disease by coronary angiography, and clinical and echocardiographic follow-up at 3 months after admission to the chest pain unit. Results: In all patients, coronary angiography did not show significant coronary artery stenosis. Troponin I levels and creatine kinase were higher in patients with AM compared to those without (both P < .001). There were no significant differences among LLC, T2-weighted short inversion time inversion recovery (STIR) sequences, early (EGE), and late (LGE) gadolinium-enhancement sequences for diagnosis of AM. The AUC for qualitative (T2-weighted STIR 0.92, EGE 0.87 and LGE 0.88) and quantitative (ER 0.89 and global RE 0.80) analyses were also similar. Conclusions: Qualitative and quantitative CMR analysis methods show similar diagnostic accuracy for the diagnosis of AM. These findings suggest that a simplified approach using a shortened CMR protocol including only T2-weighted STIR sequences might be useful to rule out AM in patients with acute coronary syndrome and normal coronary angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging in Postprostatectomy Radiotherapy Planning

Purpose: To investigate whether the use of magnetic resonance imaging (MRI) in prostate bed treatment planning could influence definition of the clinical target volume (CTV) and organs at risk. Methods and Materials: A total of 21 consecutive patients referred for prostate bed radiotherapy were included in the present retrospective study. The CTV was delineated according to the European Organization for Research and Treatment of Cancer recommendations on computed tomography (CT) and T{sub 1}-weighted (T{sub 1}w) and T{sub 2}-weighted (T{sub 2}w) MRI. The CTV magnitude, agreement, and spatial differences were evaluated on the planning CT scan after registration with the MRI scans. Results: The CTV was significantly reduced on the T{sub 1}w and T{sub 2}w MRI scans (13% and 9%, respectively) compared with the CT scans. The urinary bladder was drawn smaller on the CT scans and the rectum was smaller on the MRI scans. On T{sub 1}w MRI, the rectum and urinary bladder were delineated larger than on T{sub 2}w MRI. Minimal agreement was observed between the CT and T{sub 2}w images. The main spatial differences were measured in the superior and superolateral directions in which the CTV on the MRI scans was 1.8-2.9 mm smaller. In the posterior and inferior border, no difference was seen between the CT and T{sub 1}w MRI scans. On the T{sub 2}w MRI scans, the CTV was larger in these directions (by 1.3 and 1.7 mm, respectively). Conclusions: The use of MRI in postprostatectomy radiotherapy planning resulted in a reduction of the CTV. The main differences were found in the superior part of the prostate bed. We believe T{sub 2}w MRI enables more precise definition of prostate bed CTV than conventional planning CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory Amplitude Guided 4-Dimensional Magnetic Resonance Imaging

Purpose: To evaluate the feasibility of prospectively guiding 4-dimensional (4D) magnetic resonance imaging (MRI) image acquisition using triggers at preselected respiratory amplitudes to achieve T{sub 2} weighting for abdominal motion tracking. Methods and Materials: A respiratory amplitude-based triggering system was developed and integrated into a commercial turbo spin echo MRI sequence. Initial feasibility tests were performed on healthy human study participants. Four respiratory states, the middle and the end of inhalation and exhalation, were used to trigger 4D MRI image acquisition of the liver. To achieve T{sub 2} weighting, the echo time and repetition time were set to 75 milliseconds and 4108 milliseconds, respectively. Single-shot acquisition, together with parallel imaging and partial k-space imaging techniques, was used to improve image acquisition efficiency. 4D MRI image sets composed of axial or sagittal slices were acquired. Results: Respiratory data measured and logged by the MRI scanner showed that the triggers occurred at the appropriate respiratory levels. Liver motion could be easily observed on both 4D MRI image datasets by sensing either the change of liver in size and shape (axial) or diaphragm motion (sagittal). Both 4D MRI image datasets were T{sub 2}-weighted as expected. Conclusions: This study demonstrated the feasibility of achieving T{sub 2}-weighted 4D MRI images using amplitude-based respiratory triggers. With the aid of the respiratory amplitude-based triggering system, the proposed method is compatible with most MRI sequences and therefore has the potential to improve tumor-tissue contrast in abdominal tumor motion imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

C-13 Nuclear Magnetic Resonance Spectroscopy of Methane and Carbon Dioxide in a Natural Shale

13C nuclear magnetic resonance (NMR) spectroscopy shows that high resolution spectra of isotopically enriched CH4 and CO2 can be obtained for a natural shale sample under in situ conditions relevant to petroleum reservoirs (T = 323K and Pfluid = 90 bars) using magic angle spinning. These results show for the first time that this technique has the potential to provide otherwise unobtainable, species-specific structural and dynamical insight into the pore systems of shales and other tight reservoir and source rocks, and can thus help guide design of the methods used in enhanced petroleum production. The NMR results show that CH4 and CO2 readily displace each other in the nano- (<10 nm) and meso-porosity (>10 nm) pore spaces of the shales; that CH4 in nanopores, mesopores, and bulk fluid can be distinguished; and that the partitioning of CH4 between nanopores and mesopores depends on the CH4/CO2 ratio and, thus, partial pressures of the individual fluid species.

Bowers, Geoffrey M.↗

Influence of Resonant Magnetic Perturbations on transport barrier dynamics

Our work focuses on the effects of Resonant Magnetic Perturbations (RMPs) on ELM stabilization, since recent experiments [T. Evans et al., Phys. Rev. Lett. 92, 235003 (2004), Y. Liang et al., Phys. Rev. Lett. 98, 265004 (2007), K. Finken et al., Nucl. Fusion 47, 522-534 (2007)] demonstrated that the RMP control technique is very promising whereas much of the physics remains to be understood. We present the results of microturbulence simulations with a transport barrier showing the stabilization effect of RMPs on barrier relaxations, and giving insight on the physical mecanisms at play.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-J-151: Evaluation of a Magnetic Resonance Image Gated Radiotherapy System Using a Motion Phantom and Radiochromic Film

Purpose: Magnetic resonance image (MRI) guided radiotherapy enables gating directly on target position for soft-tissue targets in the lung and abdomen. We present a dosimetric evaluation of a commercially-available FDA-approved MRI-guided radiotherapy system’s gating performance using a MRI-compatible respiratory motion phantom and radiochromic film. Methods: The MRI-compatible phantom was capable of one-dimensional motion. The phantom consisted of a target rod containing high-contrast target inserts which moved inside a body structure containing background contrast material. The target rod was equipped with a radiochromic film insert. Treatment plans were generated for a 3 cm diameter spherical target, and delivered to the phantom at rest and in motion with and without gating. Both sinusoidal and actual tumor trajectories (two free-breathing trajectories and one repeated-breath hold) were used. Gamma comparison at 5%/3mm was used to measure fidelity to the static target dose distribution. Results: Without gating, gamma pass rates were 24–47% depending on motion trajectory. Using our clinical standard of repeated breath holds and a gating window of 3 mm with 10% of the target allowed outside the gating boundary, the gamma pass rate was 99.6%. Relaxing the gating window to 5 mm resulted in gamma pass rate of 98.6% with repeated breath holds. For all motion trajectories gated with 3 mm margin and 10% allowed out, gamma pass rates were between 64–100% (mean:87.5%). For a 5 mm margin and 10% allowed out, gamma pass rates were between 57–98% (mean: 82.49%), significantly lower than for 3 mm by paired t-test (p=0.01). Conclusion: We validated the performance of respiratory gating based on real-time cine MRI images with the only FDA-approved MRI-guided radiotherapy system. Our results suggest that repeated breath hold gating should be used when possible for best accuracy. A 3 mm gating margin is statistically significantly more accurate than a 5 mm gating margin.

60 APPLIED LIFE SCIENCES↗

Resonant magnetic perturbations and edge ergodization on the COMPASS tokamak

Results of calculations of resonant magnetic perturbation spectra on the COMPASS tokamak are presented. Spectra of the perturbations are calculated from the vacuum field of the perturbation coils. Ergodization is then estimated by applying the criterion of overlap of the resulting islands and verified by field line tracing. Results show that for the chosen configuration of perturbation coils an ergodic layer appears in the pedestal region. The ability to form an ergodic layer is similar to the theoretical results for the ELM suppression experiment at DIII-D; thus, a comparable effect on ELMs can be expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗