Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Deuteron microscopic optical model potential

A deuteron microscopic optical model potential is obtained by the Green function method through nuclear-matter approximation and local-density approximation based on the effective Skyrme interaction. The microscopic optical model potential is used to calculate the deuteron reaction cross sections and the elastic scattering angular distributions for some target nuclei in the mass range 6<=A<=208 with incident deuteron energies up to 200 MeV. The calculated results are compared with the experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-energy (p,{gamma}) reactions in Ni and Cu nuclei using a microscopic optical model

Radiative capture reactions for low-energy protons have been theoretically studied for Ni and Cu isotopes using the microscopic optical model. The optical potential has been obtained in the folding model using different microscopic interactions with the nuclear densities from relativistic mean field calculations. The calculated total cross sections as well as the cross sections for individually low-lying levels have been compared with measurements involving stable nuclear targets. Rates for the rapid proton capture process have been evaluated for astrophysically important reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

{sup 4}He microscopic optical model potential

The {sup 4}He microscopic optical model potential is obtained by Green's function method through nuclear matter approximation and local density approximation based on the effective Skyrme interaction. The microscopic optical model potential is analyzed and utilized to calculate the reaction cross sections and elastic scattering angular distributions for the target nuclei in the mass range 12{<=}A{<=}209 with incident {sup 4}He energy up to 400 MeV. The theoretical results are compared with the experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lattice QCD computation of the color fields for the static hybrid quark-gluon-antiquark system, and microscopic study of the Casimir scaling

The chromoelectric and chromomagnetic fields, created by a static gluon-quark-antiquark system, are computed in quenched SU(3) lattice QCD, in a 24{sup 3}x48 lattice at {beta}=6.2 and a=0.07261(85) fm. We compute the hybrid Wilson loop with two spatial geometries, one with a U shape and another with an L shape. The particular cases of the two-gluon glueball and quark-antiquark are also studied, and the Casimir scaling is investigated in a microscopic perspective. This microscopic study of the color fields is relevant to understanding the structure of hadrons, in particular, the hybrid excitation of mesons. This also contributes to understanding confinement with flux tubes and to discriminating between the models of fundamental versus adjoint confining strings, analogous to type-II and type-I superconductivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microscopic Theory of Fluctuating Hydrodynamics in Nonlinear Lattices

The theory of fluctuating hydrodynamics has been an important tool for analyzing macroscopic behavior in nonlinear lattices. However, despite its practical success, its microscopic derivation is still incomplete. In this work, we provide the microscopic derivation of fluctuating hydrodynamics, using the coarse-graining and projection technique; the equivalence of ensembles turns out to be critical. The Green-Kubo (GK)-like formula for the bare transport coefficients are presented in a numerically computable form. Our numerical simulations show that the bare transport coefficients exist for a sufficiently large but finite coarse-graining length in the infinite lattice within the framework of the GK-like formula. Finally, this demonstrates that the bare transport coefficients uniquely exist for each physical system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Global Microscopic Description of Nucleon-Nucleus Scattering with Quantified Uncertainties

We develop for the first time a microscopic global nucleon-nucleus optical potential with quantified uncertainties suitable for analyzing nuclear reaction experiments at next-generation rare-isotope beam facilities. Within the improved local density approximation and without any adjustable parameters, we begin by computing proton-nucleus and neutron-nucleus optical potentials from a set of five nuclear forces from chiral effective field theory for 1800 target nuclei in the mass range 12 ≤ A ≤ 242 for energies between 0 MeV < E ≲ 150 MeV. We then parameterize a global optical potential for each chiral force that depends smoothly on the projectile energy as well as the target nucleus mass number and isospin asymmetry. Uncertainty bands for elastic scattering observables are generated from a full covariance analysis of the parameters entering in the description of our global optical potential and benchmarked against existing experimental data for stable target nuclei. Since our approach is purely microscopic, we anticipate a similar quality of the model for nucleon scattering on unstable isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In situ environmental scanning electron microscope observations of colloidal failure mechanisms using the Brazilian disk test

This paper presents data produced using a novel test fixture to study the crack initiation and fracture mechanisms in brittle colloidal systems, in situ in an Environmental Scanning Electron Microscope (ESEM), based on the Brazilian disk test. The test is based on diametral compression loading of a disk of material, which causes a tensile stress in the centre of the disk perpendicular to the loading direction. Key advantages over commercial tensile tests are simplicity of specimen preparation, especially important for fragile and brittle materials, which because of their nature in many cases cannot be microscopically characterised after testing. The test was successful in creating the desired perpendicular tensile stresses and yielded diametral cracks across the latex specimens. It was found that when end crushing was minimal, multiple cracks initiated at several points on the disk and a number of factors appeared to influence the propagation of cracks through the latex, these include: particle packing arrangements, surface defects, and the presence of other cracks. Following the onset of fracture, it was observed that the cracks connected to form a single failure route, here described as the path of least resistance. This, in essence, resulted in the crack taking a route around stronger, more ordered regions of the latex (be they “crystals” or surface defects). The experimental results presented and discussed here represent the first attempt to utilise this loading arrangement in the study of crack propagation in colloidal systems.

42 ENGINEERING↗

Atomic-resolution lithography with an on-chip scanning tunneling microscope

In this work, atomic-resolution lithography with a Microelectromechanical-System (MEMS) based Scanning Tunneling Microscope (STM) is demonstrated for the first time. The microscope consists of a commercial UltraHigh-Vacuum (UHV) STM whose regular tip is replaced with a 1-Degree-of-Freedom (1-DOF) MEMS nanopositioner. This results in a hybrid STM system where XY-plane motions are provided by the piezotube of the original system and Z-axis motion by the MEMS with a higher bandwidth. Sharp tips made of Pt or W are added to the MEMS devices with postfabrication techniques. With this hybrid system, STM-based lithography is demonstrated on an H-passivated Si (100)-2×1 sample under UHV condition. Results prove the capability of the hybrid STM system for atomic-scale lithography. This capability, paired with the small footprint of the MEMS device, makes this approach a candidate for building a high-throughput parallel STM lithography platform by incorporating an array of 1-DOF MEMS devices that perform lithography in parallel.

Alipour, Afshin (ORCID:0000000263252067)↗

A broader view on EUV-masks: adding complementary imaging modes to the SHARP microscope

The authors are expanding the capabilities of the SHARP microscope by implementing complementary imaging modes. SHARP (the SEMATECH High-NA Actinic Reticle review Project) is an actinic, synchrotron-based microscope dedicated to extreme ultraviolet (EUV) photomask research. SHARP’s programmable Fourier Synthesis Illuminator and its use of Fresnel zoneplate lenses as imaging optics provide a versatile framework, facilitating the implementation of diverse modes beyond conventional imaging. In addition to SHARP’s set of standard zoneplates, we have created more than 100 zoneplates for complementary imaging modes, all designed to extract additional information from photomasks, improve navigation and enhance defect detection. More than 50 new zoneplates are installed in the tool; the remaining lenses are currently in production. Here in this paper we discuss the design and fabrication of zoneplates for complementary imaging modes and present image data, obtained using Zernike Phase Contrast and different implementations of Differential Interference Contrast.

36 MATERIALS SCIENCE↗

Upgrade to the SHARP EUV mask microscope

© 2019 SPIE. The Sharp High-NA Actinic Reticle review Project (SHARP) is a synchrotron-based, extreme ultraviolet (EUV) microscope dedicated to photomask research. A potential upgrade to the SHARP microscope is presented. The upgrade includes changing the light path in the instrument from its current off-Axis configuration to an on-Axis configuration. This change allows for an increased working distance of 2.5 mm or more. A central obscuration, added to the zoneplate aperture, blocks stray light from reaching the central part of the image, thus improving the image contrast. The imaging performance of the two configurations is evaluated by means of ray tracing.

Benk, M↗

WE-EF-BRA-02: A Monte Carlo Study of Macroscopic and Microscopic Dose Descriptors for Kilovoltage Cellular Dosimetry

Purpose: To investigate how doses to cellular (microscopic) targets depend on cell morphology, and how cellular doses relate to doses to bulk tissues and water for 20 to 370 keV photon sources using Monte Carlo (MC) simulations. Methods: Simulation geometries involve cell clusters, single cells, and single nuclear cavities embedded in various healthy and cancerous bulk tissue phantoms. A variety of nucleus and cytoplasm elemental compositions are investigated. Cell and nucleus radii range from 5 to 10 microns and 2 to 9 microns, respectively. Doses to water and bulk tissue cavities are compared to nucleus and cytoplasm doses. Results: Variations in cell dose with simulation geometry are most pronounced for lower energy sources. Nuclear doses are sensitive to the surrounding geometry: the nuclear dose in a multicell model differs from the dose to a cavity of nuclear medium in an otherwise homogeneous bulk tissue phantom by more than 7% at 20 keV. Nuclear doses vary with cell size by up to 20% at 20 keV, with 10% differences persisting up to 90 keV. Bulk tissue and water cavity doses differ from cellular doses by up to 16%. MC results are compared to cavity theory predictions; large and small cavity theories qualitatively predict nuclear doses for energies below and above 50 keV, respectively. Burlin’s (1969) intermediate cavity theory best predicts MC results with an average discrepancy of 4%. Conclusion: Cellular doses vary as a function of source energy, subcellular compartment size, elemental composition, and tissue morphology. Neither water nor bulk tissue is an appropriate surrogate for subcellular targets in radiation dosimetry. The influence of microscopic inhomogeneities in the surrounding environment on the nuclear dose and the importance of the nucleus as a target for radiation-induced cell death emphasizes the potential importance of cellular dosimetry for understanding radiation effects. Funded by the Natural Sciences and Engineering Research Council of Canada (NSERC), the Canada Research Chairs Program (CRC), and the Ontario Ministry of Training, Colleges and Universities.

60 APPLIED LIFE SCIENCES↗

Measurement with microscopic MRI and simulation of flow in different aneurysm models

Purpose: The impact and the development of aneurysms depend to a significant degree on the exchange of liquid between the regular vessel and the pathological extension. A better understanding of this process will lead to improved prediction capabilities. The aim of the current study was to investigate fluid-exchange in aneurysm models of different complexities by combining microscopic magnetic resonance measurements with numerical simulations. In order to evaluate the accuracy and applicability of these methods, the fluid-exchange process between the unaltered vessel lumen and the aneurysm phantoms was analyzed quantitatively using high spatial resolution. Methods: Magnetic resonance flow imaging was used to visualize fluid-exchange in two different models produced with a 3D printer. One model of an aneurysm was based on histological findings. The flow distribution in the different models was measured on a microscopic scale using time of flight magnetic resonance imaging. The whole experiment was simulated using fast graphics processing unit-based numerical simulations. The obtained simulation results were compared qualitatively and quantitatively with the magnetic resonance imaging measurements, taking into account flow and spin–lattice relaxation. Results: The results of both presented methods compared well for the used aneurysm models and the chosen flow distributions. The results from the fluid-exchange analysis showed comparable characteristics concerning measurement and simulation. Similar symmetry behavior was observed. Based on these results, the amount of fluid-exchange was calculated. Depending on the geometry of the models, 7% to 45% of the liquid was exchanged per second. Conclusions: The result of the numerical simulations coincides well with the experimentally determined velocity field. The rate of fluid-exchange between vessel and aneurysm was well-predicted. Hence, the results obtained by simulation could be validated by the experiment. The observed deviations can be caused by the noise in the measurement and by the limited resolution of the simulation. The resulting differences are small enough to allow reliable predictions of the flow distribution in vessels with stents and for pulsed blood flow.

60 APPLIED LIFE SCIENCES↗

Sci-Thur AM: YIS – 06: A Monte Carlo study of macro- and microscopic dose descriptors and the microdosimetric spread using detailed cellular models

Purpose: To develop Monte Carlo models of cell clusters to investigate the relationships between macro- and microscopic dose descriptors, quantify the microdosimetric spread in energy deposition for subcellular targets, and determine how these results depend on the computational model. Methods: Microscopic tissue structure is modelled as clusters of 13 to 150 cells, with cell (nuclear) radii between 5 and 10 microns (2 and 9 microns). Energy imparted per unit mass (specific energy or dose) is scored in the nucleus (D{sub nuc}) and cytoplasm (D{sub cyt}) for incident photon energies from 20 to 370 keV. Dose-to-water (D{sub w,m}) and dose-to-medium (D{sub m,m}) are compared to D{sub nuc} and D{sub cyt}. Single cells and single nuclear cavities are also simulated. Results: D{sub nuc} and D{sub cyt} are sensitive to the surrounding environment with deviations of up to 13% for a single nucleus/cell compared with a multicellular cluster. These dose descriptors vary with cell and nucleus size by up to 10%. D{sub nuc} and D{sub cyt} differ from D{sub w,m} and D{sub m,m} by up to 32%. The microdosimetric spread is sensitive to whether cells are arranged randomly or in a hexagonal lattice, and whether subcellular compartment sizes are sampled from a normal distribution or are constant throughout the cluster. Conclusions: D{sub nuc} and D{sub cyt} are sensitive to cell morphology, elemental composition and the presence of surrounding cells. The microdosimetric spread was investigated using realistic elemental compositions for the nucleus and cytoplasm, and depends strongly on subcellular compartment size, source energy and dose.

60 APPLIED LIFE SCIENCES↗

Identification of site-specific isotopic labels by vibrational spectroscopy in the electron microscope

The identification of isotopic labels by conventional macroscopic techniques lacks spatial resolution and requires relatively large quantities of material for measurements. We recorded the vibrational spectra of an α amino acid, l -alanine, with damage-free “aloof” electron energy-loss spectroscopy in a scanning transmission electron microscope to directly resolve carbon-site–specific isotopic labels in real space with nanoscale spatial resolution. An isotopic red shift of 4.8 ± 0.4 milli–electron volts in C–O asymmetric stretching modes was observed for 13 C-labeled l -alanine at the carboxylate carbon site, which was confirmed by macroscopic infrared spectroscopy and theoretical calculations. The accurate measurement of this shift opens the door to nondestructive, site-specific, spatially resolved identification of isotopically labeled molecules with the electron microscope.

74 ATOMIC AND MOLECULAR PHYSICS↗

Achieving sub-0.5-angstrom–resolution ptychography in an uncorrected electron microscope

Subangstrom resolution has long been limited to aberration-corrected electron microscopy, where it is a powerful tool for understanding the atomic structure and properties of matter. Here, we demonstrate electron ptychography in an uncorrected scanning transmission electron microscope (STEM) with deep subangstrom spatial resolution down to 0.44 angstroms, exceeding the conventional resolution of aberration-corrected tools and rivaling their highest ptychographic resolutions​. Our approach, which we demonstrate on twisted two-dimensional materials in a widely available commercial microscope, far surpasses prior ptychographic resolutions (1 to 5 angstroms) of uncorrected STEMs. We further show how geometric aberrations can create optimized, structured beams for dose-efficient electron ptychography. Our results demonstrate that expensive aberration correctors are no longer required for deep subangstrom resolution.

36 MATERIALS SCIENCE↗

Microscopic Theory of Pinning of Multiquantum Vortex in Cylindrical Cavity

We have proposed and developed a microscopic model of depinning (escape) of a multiquantum vortex in a superconductor with a cylindrical nonconducting cavity with the transverse size smaller than or on the order of the superconducting coherence length ξ{sub 0} at zero temperature. The spectrum of subgap quasiparticle excitations in two- and three-quantum vortices trapped by a cylindrical cavity has been calculated in the quasiclassical approximation. It is shown that the transformation of the spectrum is accompanied by break of anomalous spectral branches due to normal reflection of quasiparticles from the surface of a defect. A microscopic (spectral) criterion for multiquantum vortex pinning has been proposed; according to this criterion, the multiquantum vortex can be trapped in the cavity during the formation of a minigap in the elementary excitation spectrum near the Fermi level. Self-consistent calculations of density of states N(r, ε) for two- and three-quantum vortices trapped by a cylindrical cavity of radius on the order of ξ{sub 0} have been performed using quasiclassical Eilenberger equations. In the pure limit and for low temperatures T ≪ T{sub c}, peculiarities observed in the N(r, ε) distribution reflect the presence of M anomalous spectral branches in the M-quantum vortex and confirm the correctness of the spectral criterion of pinning (depinning) of a multiquantum vortex.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neuromorphic data microscope

In 2016, Lewis Rhodes Labs, (LRL), shipped the first commercially viable Neuromorphic Processing Unit, (NPU), branded as a Neuromorphic Data Microscope (NDM). This product leverages architectural mechanisms derived from the sensory cortex of the human brain to efficiently implement pattern matching. LRL and Sandia National Labs have optimized this product for streaming analytics, and demonstrated a 1,000x power per operation reduction in an FPGA format. When reduced to an ASIC, the efficiency will improve to 1,000,000x. Additionally, the neuromorphic nature of the device gives it powerful computational attributes that are counterintuitive to those schooled in traditional von Neumann architectures. The Neuromorphic Data Microscope is the first of a broad class of brain-inspired, time domain processors that will profoundly alter the functionality and economics of data processing.

47 OTHER INSTRUMENTATION↗

A Closed-Loop Proportional-Integral (PI) Control Software for Fully Mechanically Controlled Automated Electron Microscopic Tomography

A closed-loop proportional-integral (PI) control software is provided for fully mechanically controlled automated electron microscopic tomography. The software is developed based on Gatan DigitalMicrograph, and is compatible with Zeiss LIBRA 120 transmission electron microscope. However, it can be expanded to other TEM instrument with modification. The software consists of a graphical user interface, a digital PI controller, an image analyzing unit, and other drive units (i.e.: image acquire unit and goniometer drive unit). During a tomography data collection process, the image analyzing unit analyzes both the accumulated shift and defocus value of the latest acquired image, and provides the results to the digital PI controller. The digital PI control compares the results with the preset values and determines the optimum adjustments of the goniometer. The goniometer drive unit adjusts the spatial position of the specimen according to the instructions given by the digital PI controller for the next tilt angle and image acquisition. The goniometer drive unit achieves high precision positioning by using a backlash elimination method. The major benefits of the software are: 1) the goniometer drive unit keeps pre-aligned/optimized beam conditions unchanged and achieves position tracking solely through mechanical control; 2) the image analyzing unit relies on only historical data and therefore does not require additional images/exposures; 3) the PI controller enables the system to dynamically track the imaging target with extremely low system error.

Ren, Gang↗