Search NASA⌕ Search

SEARCH · Search NASA

Results for “MM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Injection-locked composite lasers for mm-wave modulation : LDRD 117819 final report.

This report summarizes a 3-year LDRD program at Sandia National Laboratories exploring mutual injection locking of composite-cavity lasers for enhanced modulation responses. The program focused on developing a fundamental understanding of the frequency enhancement previously demonstrated for optically injection locked lasers. This was then applied to the development of a theoretical description of strongly coupled laser microsystems. This understanding was validated experimentally with a novel 'photonic lab bench on a chip'.

42 ENGINEERING↗

Ferrite-Cored Solenoidal Induction Coil Sensor for BUD (MM-1667)

We have designed and lab tested a new ferrite cored induction coil sensor for measuring the secondary fields from metallic UXO with the BUD system. The objective was to replace the 5-inch diameter air-cored coils in the BUD system with smaller sensors that would allow the placement of multiple sensors in the smaller package of the new BUD hand-held system. A ferrite-cored solenoidal coil of length L can easily be made to have sensitivity and noise level roughly the same as an air-cored coil of a diameter on the same order as L. A ferrite-cored solenoidal coil can easily have a feedback configuration to achieve critical damping. The feedback configuration leads to a very stable response. Feedback ferrite-cored solenoidal coils show very little interaction as long as they are separated by one half their length.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

New Strategies for 0.5 mm Resolution, High Sensitivity, Multi- Radionuclide Imaging

This project constitutes a 0.5-millimeter resolution radionuclide detector system built from CZT. (1) A novel dual-crystal photon detector module design with cross-strip electrode patterns was developed; (2) The module mechanical assembly was built; (3) A data acquisition (DAQ) chain for the module was produced; (4) A software tool was developed to incorporate novel time and energy measurement calibration techniques. (5) A small multi-detector prototype of the radionuclide imaging system was built from this module for system-level characterizations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

100 mm Engineered InP-on-Si Laminate Substrates for InP-based Multijunction Solar Cells

The project focused on fabrication of InP/Si laminate substrates as templates for growth of InGaAsP/InGaAs and InAlAs/InGaAsP/InGaAs multijunction solar cells. InP/Si template substrates were developed and used as templates for InGaAs solar growth. A novel feature of the program was development of the virtual substrate template, which enables a substrate to be formed with a lattice constant intermediate between those of GaAs and InP. Large-area virtual substrate templates were formed by transfer and bonding of dislocation free InGaAs films wafer onto silicon substrates.

14 SOLAR ENERGY↗

New Methods to Produce and Extend the Spectral Range of Photocathodes for Large Area Photodetectors with mm scale Space Resolution (Final Report)

Cornell group has developed recipes to grow photocathodes belonging to the alkali antimonide family using evaporation from elemental sources with and without line of sight between the sources and the glass substrate. Photocathodes were characterized in terms of their quantum efficiency in the spectral range covering the visible and the near infrared part of the spectrum. Two different approaches have been used to demonstrate the growth of high quantum efficiency photocathodes: the first approach makes use of elemental antimony and alkali metals loaded into ceramic crucibles hosted into effusion cells like the one used in molecular beam epitaxy reactors; whereas in the second approach the antimony film is evaporated onto the transparent substrate using effusion cells and then transferred into a different reaction chamber where exposure to the alkali metals coming from an elemental source lacking the line of sight to the substrate is used to produce the photocathode material. The research conducted opens the exploration of alternative methods for the synthesis of photocathodes specifically designed to be implemented over large areas maximizing the production throughput and lowering the cost. It particular, this research can benefit future HEP programs by providing new methods that can be adopted to produce photon detectors for future experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of the Sub-mm Delay Plates for the IOTA Optical-Stochastic-Cooling Experiment

This note describes the methods used to measure the thickness profile of the glass plates used in the optical-delay line of the Optical Stochastic Cooling (OSC) experiment at the Fermilab’s IOTA ring. The plates have a nominal thickness of 250 μm and the measurement was performed to verify the nominal thickness and determine its variation over the entire plate surface. All the available plates were characterized and the impact of the thickness variation on the radiation wave front was found to be negligible using wave-optics simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Attenuator, PC-2.92mm, Fixed (Proficiency Test Report; PT ID Number 6679665)

The PSL has reviewed the documentation and data provided by NNSS–Livermore Operations with respect to this proficiency test. This proficiency test was performed to assess NNSS–Livermore Operations’ ability to perform scattering parameter calibrations. The level of documentation was satisfactory. On 12/28/2021, NNSS–Livermore Operations reported the data for the proficiency test conducted on the attenuator. NNSS–Livermore Operations performed this proficiency test using an Anritsu vector network analyzer, an electronic calibration module, and verification kit. The PSL used a Keysight vector network analyzer and mechanical calibration kit. The PSL results included in this proficiency test report were taken on June 23, 2020.

42 ENGINEERING↗

Attenuator, PC-2.92mm, Fixed (Proficiency Test Report: Document # 6679664_11752120)

The PSL has reviewed the documentation and data provided by NNSS–Livermore Operations with respect to this proficiency test. This proficiency test was performed to assess NNSS–Livermore Operations’ ability to perform scattering parameter calibrations. The level of documentation was satisfactory. On 5/19/2020, NNSS–Livermore Operations reported the data for the proficiency test conducted on the attenuator. NNSS–Livermore Operations performed this proficiency test using an Anritsu vector network analyzer, an electronic calibration module, and verification kit. The PSL used a Keysight vector network analyzer and mechanical calibration kit. The PSL results included in this proficiency test report were taken on June 23, 2020.

47 OTHER INSTRUMENTATION↗

Polymers used in 4 mm PV Connectors [Slides]

Polymer cracks are not a new problem in the PV industry. However, the suddenness and severity of the cracking connector model is new and concerning. Some sites are experiencing wide-spread cracking of a specific connector model. The preliminary investigation results are (1) there are potential clearance issues with the O-ring, leading to high mechanical stress; (2) potential use of lubrication yields polymer embrittlement; and (3) clear mechanical or chemical differences between the affected model and other PPE-based models using FTIR and tensile testing could not be demonstrated.

36 MATERIALS SCIENCE↗

Advanced high power mm-wave microwave devices Final Report CRADA No. TC-0287-92

The purpose of this CRADA was to improve existing high-average-power microwave devices and develop the next generation microwave devices for energy and defense applications. A Free Electron Maser was under test at the FOM Institute (Rijnhuizen) Netherlands with the goal of producing a lMW-long pulse to CW microwave output in the range 130GHz to 250GHz. The DC acceleration and beam transport system is eventually to be used in a depressed collector configuration requiring 99.8% beam transmission in order that the high voltage 2MV supply be required only to supply 20 milliamps of body cucrent. A relativistic version of the Herrmarm optical theory originally developed for microwave tube beams was used to take into account thermal elections far out on the gaussian distribution tail that can translate into beam current well outside the ideal beam edge. This theory was applied to the FOM beamline design and predicts that the beam envelope containing 99.8% of the current can be successfully transported to the undulator for a wide range of assumed eminence values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗