Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONOCHROMATIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Detection of the Ultraviolet Spectrum of the Hot Subdwarf Companion of 60 Cygni (B1 Ve) from a Survey of IUE Spectra of Be Stars

We used archival International Ultraviolet Explorer (IUE) high-dispersion, short wavelength spectra data to search for evidence of the spectra of hot subdwarf companions of six rapidly rotating Be stars in binary systems. We searched for the signature of a hot companion through an analysis of the cross-correlation functions (CCFs) of observed and model spectra that were separated into primary and secondary components using a Doppler tomography algorithm and adopted spectroscopic orbital solutions. A positive detection of the flux from a hot companion was made for the reconstructed secondary CCF of just one target, 60 Cygni (B1 Ve). We estimate that the companion of the Be star in 60 Cygni has T{sub eff}=42±4 kK, mass ratio M{sub 2}/M{sub 1}=0.15±0.02, and monochromatic flux ratio f{sub 2}/f{sub 1}=0.034±0.002 in the spectral region near 1525 Å. If the companions of the other target Be stars are also hot, then they must be faint and contribute less than ≈1% of the UV flux (<0.6% in the case of γ Cas). We also discuss a shell episode of Pleione (28 Tau) recorded in the IUE spectran in an appendix.

79 ASTRONOMY AND ASTROPHYSICS↗

VIRIAL BLACK HOLE MASS ESTIMATES FOR 280,000 AGNs FROM THE SDSS BROADBAND PHOTOMETRY AND SINGLE-EPOCH SPECTRA

We use the Sloan Digital Sky Survey (SDSS) Quasar Data Release 12 (DR12Q), containing nearly 300,000 active galactic nuclei (AGNs), to calculate the monochromatic luminosities at 5100, 3000, and 1350 Å, derived from the broadband extinction-corrected SDSS magnitudes. After matching these sources to their counterparts from the SDSS Quasar Data Release 7 (DR7Q), we find very high correlations between our luminosities and DR7Q spectra-based luminosities with minute mean offsets (∼0.01 dex) and dispersions of differences of 0.11, 0.10, and 0.12 dex, respectively, across a luminosity range of 2.5 dex. We then estimate the black hole (BH) masses of the AGNs using the broad line region radius–disk luminosity relations and the FWHM of the Mg ii and C iv emission lines, to provide a catalog of 283,033 virial BH mass estimates (132,451 for Mg ii, 213,071 for C iv, and 62,489 for both) along with the estimates of the bolometric luminosity and Eddington ratio for 0.1 < z < 5.5 and for roughly a quarter of the sky covered by SDSS. The BH mass estimates from Mg ii turned out to be closely matched to the ones from DR7Q with a dispersion of differences of 0.34 dex across a BH mass range of ∼2 dex. We uncovered a bias in the derived C iv FWHMs from DR12Q as compared to DR7Q, which we correct empirically. The C iv BH mass estimates should be used with caution because the C iv line is known to cause problems in the estimation of BH mass from single-epoch spectra. Finally, after the FWHM correction, the AGN BH mass estimates from C iv closely match the DR7Q ones (with a dispersion of 0.28 dex), and more importantly the Mg ii and C iv BH masses agree internally with a mean offset of 0.07 dex and a dispersion of 0.39 dex.

79 ASTRONOMY AND ASTROPHYSICS↗

A Catalog of Narrow Line Seyfert 1 Galaxies from the Sloan Digital Sky Survey Data Release 12

We present a new catalog of narrow-line Seyfert 1 (NLSy1) galaxies from the Sloan Digital Sky Survey Data Release 12 (SDSS DR12). This was obtained by a systematic analysis through modeling of the continuum and emission lines of the spectra of all the 68,859 SDSS DR12 objects that are classified as “QSO” by the SDSS spectroscopic pipeline with z<0.8 and a median signal-to-noise ratio (S/N) > 2 pixel{sup −1}. This catalog contains a total of 11,101 objects, which is about 5 times larger than the previously known NLSy1 galaxies. Their monochromatic continuum luminosity at 5100 Å is found to be strongly correlated with Hβ, Hα, and [O iii] emission line luminosities. The optical Fe ii strength in NLSy1 galaxies is about two times larger than the broad-line Seyfert 1 (BLSy1) galaxies. About 5% of the catalog sources are detected in the FIRST survey. The Eddington ratio (ξ{sub Edd}) of NLSy1 galaxies has an average of log ξ{sub Edd} of −0.34, much higher than −1.03 found for BLSy1 galaxies. Their black hole masses (M{sub BH}) have an average of log M{sub BH} of 6.9 M{sub ⊙}, which is less than BLSy1 galaxies, which have an average of log M{sub BH} of 8.0 M{sub ⊙}. The M{sub BH} of NLSy1 galaxies is found to be correlated with their host galaxy velocity dispersion. Our analysis suggests that geometrical effects playing an important role in defining NLSy1 galaxies and their M{sub BH} deficit is perhaps due to their lower inclination compared to BLSy1 galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

IMAGING THE ELUSIVE H-POOR GAS IN THE HIGH adf PLANETARY NEBULA NGC 6778

We present the first direct image of the high-metallicity gas component in a planetary nebula (NGC 6778), taken with the OSIRIS Blue Tunable Filter centered on the O ii λ 4649+50 Å optical recombination lines (ORLs) at the 10.4 m Gran Telescopio Canarias. We show that the emission of these faint O ii ORLs is concentrated in the central parts of the planetary nebula and is not spatially coincident either with emission coming from the bright [O iii] λ 5007 Å collisionally excited line (CEL) or the bright H α recombination line. From monochromatic emission line maps taken with VIMOS at the 8.2 m Very Large Telescope, we find that the spatial distribution of the emission from the auroral [O iii] λ 4363 line resembles that of the O ii ORLs but differs from nebular [O iii] λ 5007 CEL distribution, implying a temperature gradient inside the planetary nebula. The centrally peaked distribution of the O ii emission and the differences with the [O iii] and H i emission profiles are consistent with the presence of an H-poor gas whose origin may be linked to the binarity of the central star. However, determination of the spatial distribution of the ORLs and CELs in other PNe and a comparison of their dynamics are needed to further constrain the geometry and ejection mechanism of the metal-rich (H-poor) component and hence, understand the origin of the abundance discrepancy problem in PNe.

79 ASTRONOMY AND ASTROPHYSICS↗

Issues in gravitational wave detection with space missions

Two masses freely orbiting in the solar system, separated by several astronomical units, are proposed as antennas for the detection of monochromatic gravitational radiation emitted by double stars. If one of these masses was an artificial satellite, then relative acceleration could be measured by the Doppler effect on the satellite radio signal. A highly accurate clock would have to be invented and incorporated into the tracking network in order for this plan to be feasible.

Davies, R. W.↗

Pseudo-backscatter laser Doppler velocimeter employing antiparallel-reflector in the forward direction

A laser Doppler velocimeter for measuring the velocity of a flowing fluid was discussed. It comprises laser means for providing first and second beams of collimated coherent monochromatic electromagnetic radiation which are focused to intersect at a predetermined location in a flowing fluid. The movement of the particles of the fluid serve to scatter radiation in substantially all directions. The scattered radiation is shifted in frequency from that of the first beam by an amount corresponding to the velocity of the fluid at the predetermined location. A corner cube is disposed generally forward of the predetermined location, the corner cube responding to a portion of the radiation scattered in the forward direction and being operative to reflect the portion in a direction substantially antiparallel to the forward direction.

Gunter, W. D., Jr.↗

Widely tunable (PbSn)Te lasers using etched cavities for mass production

Lead salt diode lasers are being used increasingly as tunable sources of monochromatic infrared radiation in a variety of spectroscopic systems. These devices are particularly useful, both in the laboratory and in the field, because of their high spectral brightness (compared to thermal sources) and wide spectral coverage (compared to line-tunable gas lasers). While the primary commercial application of these lasers has been for ultrahigh resolution laboratory spectroscopy, there are numerous systems applications, including laser absorbtion pollution monitors and laser heterodyne radiometers, for which diode lasers have great potential utility. Problem areas related to the wider use of these components are identified. Among these are total tuning range, mode control, and high fabrication cost. A fabrication technique which specifically addresses the problems of tuning range and cost, and which also has potential application for mode control, is reported.

Miller, M. D.↗

Towards the Structure Determination of a Modulated Protein Crystal: The Semicrystalline State of Profilin:Actin

One of the remaining challenges to structural biology is the solution of modulated structures. While small molecule crystallographers have championed this type of structure, to date, no modulated macromolecular structures have been determined. Modulation of the molecular structures within the crystal can produce satellite reflections or a superlattice of reflections in reciprocal space. We have developed the data collection methods and strategies that are needed to collect and analyze these data. If the macromolecule's crystal lattice is composed of physiologically relevant packing contacts, structural changes induced under physiological conditions can cause distortion relevant to the function and biophysical processes of the molecule making up the crystal. By careful measurement of the distortion, and the corresponding three-dimensional structure of the distorted molecule, we will visualize the motion and mechanism of the biological macromolecule(s). We have measured the modulated diffraction pattern produced by the semicrystalline state of profilin:actin crystals using highly parallel and highly monochromatic synchrotron radiation coupled with fine phi slicing (0.001-0.010 degrees) for structure determination. These crystals present these crystals present a unique opportunity to address an important question in structural biology. The modulation is believed to be due to the formation of actin helical filaments from the actin beta ribbon upon the pH-induced dissociation of profilin. To date, the filamentous state of actin has resisted crystallization and no detailed structures are available. The semicrystalline state profilin:actin crystals provides a unique opportunity to understand the many conformational states of actin. This knowledge is essential for understanding the dynamics underlying shape changes and motility of eukaryotic cells. Many essential processes, such as cytokinesis, phagocytosis, and cellular migration depend upon the capacity of the actin microfilament system to be restructured in a controlled manner via polymerization, depolymerization, severing, cross-linking, and anchorage. The structure the semicrystalline state of profilin:actin will challenge and validate current models of muscle contraction and cell motility. The methodology and theory under development will be easily extendable to other systems.

Borgstahl, G.↗

Alternative Process for Manufacturing of Thin Layers of Boron for Neutron Measurement

Due to the worldwide shortage of helium 3, Boron-lined proportional counters are developed intensively by several groups. Up to now, thin boron containing layers for neutron detectors are essentially produced by sputtering of boron carbide (B{sub 4}C). This technology provides high quality films but it is slow and expensive. Our paper describes a novel and inexpensive technology for producing boron layers. This technology is based on chemical synthesis of boron 10 nanoparticles, and on electrophoretic deposition of these particles on metallic plates, or on metallic pieces with more complex shapes. The chemical synthesis consists in: - Heating boron 10 with lithium up to 700 deg. C under inert atmosphere: an intermetallic compound, LiB, is produced; - Hydrolysing this intermetallic compound: LiB + H{sub 2}O → B + Li{sup +} + OH{sup -} + 1/2H{sub 2}, where B is under the form of nanoparticles; - Purifying the suspension of boron nanoparticles in water, from lithium hydroxide, by successive membrane filtrations; - Evaporating the purified suspension, in order to get a powder of nanoparticles. The obtained nanoparticles have size around 300 nm, with a high porosity, of about 50%. This particle size is equivalent to about 150 nm massive particles. The nanoparticles are then put into suspension in a specific solvent, in order to perform deposition on metallic surfaces, by electrophoretic method. The solvent is chosen so that it is not electrolysed even under voltages of several tens of volts. An acid is dissolved into the solvent, so that the nanoparticles are positively charged. Deposition is performed on the cathode within about 10 min. The cathode could be an aluminium plate, or a nickel coated aluminium plate. Homogeneous deposition may also be performed on complex shapes, like grids in a Multigrid detector. A large volume of pieces, can be coated with a Boron-10 film in a few hours. The thickness of the layer can be adjusted according to the required neutron detection characteristics, between 0,5 to 5 μm (equivalent to 0,25 to 2.5 massive layer). The thickness is homogenous within a ±20% range. The layer is an almost pure {sup 10}B layer (90%). The ratio of the amount of deposed boron 10 to the amount of raw boron 10 used is more than 80%. Hence, another advantage of this technique is that Boron 10 will be deposited on the cathodes only, without loss of this expensive material. 2 grids of a Multi-Grid detector have been coated with pure Boron by using this technique. The film structure has been analysed with a microscope and the detector has been tested on a monochromatic neutron beam line. Preliminary results will be shown. (authors)

36 MATERIALS SCIENCE↗

Theory of the special Smith-Purcell radiation from a rectangular grating

The recently uncovered special Smith-Purcell radiation (S-SPR) from the rectangular grating has significantly higher intensity than the ordinary Smith-Purcell radiation (SPR). Its monochromaticity and directivity are also much better. Here we explored the mechanism of the S-SPR by applying the fundamental electromagnetic theory and simulations. We have confirmed that the S-SPR is exactly from the radiating eigen modes of the grating. Its frequency and direction are well correlated with the beam velocity and structure parameters, which indicates its promising applications in tunable wave generation and beam diagnostic.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation of quasi-monochromatic beams of accelerated electrons during interaction of weak-contrast intense femtosecond laser radiation with a metal-foil edge

The formation of monoenergetic beams of accelerated electrons by focusing femtosecond laser radiation with an intensity of 2 Multiplication-Sign 10{sup 17} W cm{sup -2} onto an edge of aluminium foil has been experimentally demonstrated. The electrons had energy distributions peaking in the range from 0.2 to 0.8 MeV and an energy spread less than 20 %. The acceleration mechanism related to the generation of a plasma wave as a result of self-modulation instability of the laser pulse in the subcritical plasma formed the prepulse of the laser system (arriving 10 ns before the main pulse) is considered. Onedimensional PIC simulation of the interaction between the laser radiation and plasma with a concentration of 5 Multiplication-Sign 10{sup 19} cm{sup -3} showed that effective excitation of a plasma wave, as well as the trapping and acceleration of the electron beam with an energy on the order of 1 MeV, may occur in the presence of inhomogeneities in the density at the plasma boundary and in the temporal shape of the beam. (extreme light fields and their applications)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality

Purpose: To evaluate the image quality of virtual monochromatic images synthesized from dual-source dual-energy computed tomography (CT) in comparison with conventional polychromatic single-energy CT for the same radiation dose. Methods: In dual-energy CT, besides the material-specific information, one may also synthesize monochromatic images at different energies, which can be used for routine diagnosis similar to conventional polychromatic single-energy images. In this work, the authors assessed whether virtual monochromatic images generated from dual-source CT scanners had an image quality similar to that of polychromatic single-energy images for the same radiation dose. First, the authors provided a theoretical analysis of the optimal monochromatic energy for either the minimum noise level or the highest iodine contrast to noise ratio (CNR) for a given patient size and dose partitioning between the low- and high-energy scans. Second, the authors performed an experimental study on a dual-source CT scanner to evaluate the noise and iodine CNR in monochromatic images. A thoracic phantom with three sizes of attenuating rings was used to represent four adult sizes. For each phantom size, three dose partitionings between the low-energy (80 kV) and the high-energy (140 kV) scans were used in the dual-energy scan. Monochromatic images at eight energies (40 to 110 keV) were generated for each scan. Phantoms were also scanned at each of the four polychromatic single energy (80, 100, 120, and 140 kV) with the same radiation dose. Results: The optimal virtual monochromatic energy depends on several factors: phantom size, partitioning of the radiation dose between low- and high-energy scans, and the image quality metrics to be optimized. With the increase of phantom size, the optimal monochromatic energy increased. With the increased percentage of radiation dose on the low energy scan, the optimal monochromatic energy decreased. When maximizing the iodine CNR in monochromatic images, the optimal energy was lower than that when minimizing noise level. When the total radiation dose was equally distributed between low and high energy in dual-energy scans, for minimum noise, the optimal energies were 68, 71, 74, and 77 keV for small, medium, large, and extra-large (xlarge) phantoms, respectively; for maximum iodine CNR, the optimal energies were 66, 68, 70, 72 keV. With the optimal monochromatic energy, the noise level was similar to and the CNR was better than that in a single-energy scan at 120 kV for the same radiation dose. Compared to an 80 kV scan, however, the iodine CNR in monochromatic images was lower for the small, medium, and large phantoms. Conclusions: In dual-source dual-energy CT, optimal virtual monochromatic energy depends on patient size, dose partitioning, and the image quality metric optimized. With the optimal monochromatic energy, the noise level was similar to and the iodine CNR was better than that in 120 kV images for the same radiation dose. Compared to single-energy 80 kV images, the iodine CNR in virtual monochromatic images was lower for small to large phantom sizes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rectennas at optical frequencies: How to analyze the response

Optical rectennas, antenna-coupled diode rectifiers that receive optical-frequency electromagnetic radiation and convert it to DC output, have been proposed for use in harvesting electromagnetic radiation from a blackbody source. The operation of these devices is qualitatively different from that of lower-frequency rectennas, and their design requires a new approach. To that end, we present a method to determine the rectenna response to high frequency illumination. It combines classical circuit analysis with classical and quantum-based photon-assisted tunneling response of a high-speed diode. We demonstrate the method by calculating the rectenna response for low and high frequency monochromatic illumination, and for radiation from a blackbody source. Such a blackbody source can be a hot body generating waste heat, or radiation from the sun.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗