Miniaturized Ion and Neutral Mass Spectrometer for CubeSat Atmospheric Measurements

To increase the number of single point in-situ measurements of thermosphere and exosphere ion and neutral composition and density, miniaturized instrumentation is in high demand to take advantage of the increasing platform opportunities available in the smallsat/cubesat industry. The INMS (Ion-Neutral Mass Spectrometer) addresses this need by providing simultaneous measurements of both the neutral and ion environment, essentially providing two instruments in one compact model. The 1.3U volume, 570 gram, 1.8W nominal power INMS instrument makes implementation into cubesat designs (3U and above) practical and feasible. With high dynamic range (0.1-500eV), mass dynamic range of 1-40amu, sharp time resolution (0.1s), and mass resolution of MdM16, the INMS instrument addresses the atmospheric science needs that otherwise would have required larger more expensive instrumentation. INMS-v1 (version 1) launched on Exocube (CalPoly 3U cubesat) in 2015 and INMS-v2 (version 2) is scheduled to launch on Dellingr (GSFC 6U cubesat) in 2017. New versions of INMS are currently being developed to increase and add measurement capabilities, while maintaining its smallsat/cubesat form.

science↗

AFE ion mass spectrometer design study

This final technical report covers the activities engaged in by the University of Texas at Dallas, Center for Space Sciences in conjunction with the NASA Langley Research Center, Systems Engineering Division in design studies directed towards defining a suitable ion mass spectrometer to determine the plasma parameter around the Aeroassisted Flight Experiment vehicle during passage through the earth's upper atmosphere. Additional studies relate to the use of a Langmuir probe to measure windward ion/electron concentrations and temperatures. Selected instrument inlet subsystems were tested in the NASA Ames Arc-Jet Facility.

Wright, Willie↗

VIPER’s Mass Spectrometer observing lunar operations (MSolo)

The Volatiles Investigating Polar Exploration Rover (VIPER) is a lunar volatiles detection and measurement mission that will land on Mons Mouton near Nobile crater, close to the Moon’s south pole. One of the analytical instruments embedded within the rover is the Mass Spectrometer observing lunar operations (MSolo) instrument. VIPER’s data will ultimately be used to create lunar water resource maps that may enable a sustained presence on the lunar surface. As VIPER navigates several kilometers of terrain, its onboard analytical instrumentation will characterize the presence of volatiles along the traverse path and identify candidate locations for drilling. Upon selection of a drilling site, the rover will position itself and deploy an auguring, percussive drill down to a meter depth. Upon extraction, regolith cuttings captured by the auger are deposited on the surface; an activity that will initiate the release of any volatile gases that are subsequently detected and quantified by MSolo. MSolo is designed to identify low-molecular-weight volatiles (between m/z 1-100) with unit mass resolution. Volatiles of interest include D/H and O18/O16 bearing species, including possible water contained within the lunar regolith. MSolo is a modified, commercial off-the-shelf (COTS) system, meaning the instrument is based on a commercially available unit that has been ruggedized for space applications.

MSolo↗

Light ion mass spectrometer for space-plasma investigations

Direct satellite measurements and ground-based techniques have given a comprehensive view of the density distribution of the cold plasma population in the earth's magnetosphere. There were, however, no direct measurements of the low-energy plasma mass composition, temperature, density, pitch-angle distribution, or plasma flow velocity. A description is presented of the evolution and development of an instrument, the Light Ion Mass Spectrometer (LIMS), designed to make these low-energy plasma measurements. The instrument was developed for flight on the spacecraft SCA-THA, a satellite to study satellite charging at high altitudes. This satellite, whose primary mission was to study spacecraft-plasma interactions and electrostatic charging, was launched into a near-geosynchronous orbit. The design requirements regarding the instrument are discussed, and attention is given to the calibration procedures, the flight configuration, and some examples of flight data.

Reasoner, D. L.↗

Advanced Laser Architecture for Two-Step Laser Tandem Mass Spectrometer

Future astrobiology missions will focus on planets with significant astrochemical or potential astrobiological features, such as small, primitive bodies and the icy moons of the outer planets that may host diverse organic compounds. These missions require advanced instrument techniques to fully and unambiguously characterize the composition of surface and dust materials. Laser desorptionionization mass spectrometry (LDMS) is an emerging instrument technology for in situ mass analysis of non-volatile sample composition. A recent Goddard LDMS advancement is the two-step laser tandem mass spectrometer (L2MS) instrument to address the need for future flight instrumentation to deconvolve complex organic signatures. The L2MS prototype uses a resonance enhanced multi-photon laser ionization mechanism to selectively detect aromatic species from a more complex sample. By neglecting the aliphatic and inorganic mineral signatures in the two-step mass spectrum, the L2MS approach can provide both mass assignments and clues to structural information for an in situ investigation of non-volatile sample composition. In this paper we will describe our development effort on a new laser architecture that is based on the previously flown Lunar Orbiter Laser Altimeter (LOLA) laser transmitter for the L2MS instrument. The laser provides two discrete midinfrared wavelengths (2.8 m and 3.4 m) using monolithic optical parametric oscillators and ultraviolet (UV) wavelength (266 nm) on a single laser bench with a straightforward development path toward flight readiness.

Laser↗

Mass Spectrometer Observing Lunar Operations (MSoLo)

Introduction: In 2019, the National Aeronautics and Space Administration (NASA) announced that it would seek to have humans return to the moon by 2024 in the hopes of establishing a more sustainable lunar presence by 2028. This goal comes with many challenges, one of upmost importance will be to utilize resources that can be found on the moon. Water, which has been identified in the lunar Polar Regions, will be a key resource for in-situ resource utilization (ISRU), as it is capable of being processed for vehicular fuel, as well as life support systems materials such as oxygen. Upcoming Commercial Lunar Payload Services (CLPS) missions will be critical for these resource assessments. Methods: A modified commercial off-the-shelf (COTS) mass spectrometer developed at Kennedy Space Center known as MSolo, consisting of a quadrupole mass filter and space rated electronics undergoes testing and modifications in order to study operational parameters to unconventional approaches needed in flight situations. In general, MSolo operates in the 0-100 m/z range with the ability to detect with a faraday cup (FC) or an electron multiplier (EM) for enhanced detection. A crossbeam (XB) ionization source is used. Preliminary Data: Prior to construction, little information was available on how the MSolo system would perform at lunar like environments, factors such as temperatures (possible fluctuations from 70 to -45 °C), vibrations from launch and their side effects, the general ability to operate while the entire system (hardware and electronic components) were in a vacuum environment, were factors that while know to flight instruments, were something new to a modified COTS system. As components start to warm up, temperature becomes a key factor (ie. heat can no longer escape the electronics as no atmosphere is present), therefore it becomes crucial to find new ways to maintain stable signals and keep the instrument tuned. Calibration itself becomes an important parameter that needs to be performed while maintaining all flight like characteristics. Even the structure itself of MSolo’s sensor needed to be changed to survive the verification parameters needed to be approved for flight. Most important, all the modifications made to the COTS system have to keep the instrument working at the same specifications of the standard commercial systems. Novel Aspect: Results gathered provide key parameters that will assist to the unconventional mass spectrometry approaches of the upcoming CLPS missions to which MSolo has been selected to.

MSolo↗

Performance of the Dragonfly Mass Spectrometer (DraMS) Programmable UV Laser Source Engineering Test Unit (ETU)

NASA’s Dragonfly mission will sample surface materials from multiple sites on Saturn’s largest moon, Titan, in exploration of its potential for prebiotic chemistry. We report on the performance of our short-pulsed UV laser transmitter, developed for the Dragonfly’s on-board Mass Spectrometer (DraMS). Our engineering test unit (ETU) has completed flight qualification and demonstrated its operational science requirements, such that the final flight unit build can begin. The Titan Hydrocarbon Analysis Nanosecond Optical Source (THANOS) ETU laser produces 266 nm laser pulses at programmable energy levels in order to create high resolution laser desorption mass spectrometry (LDMS) measurements. The laser operates in short bursts of 1-50 pulses, each at < 2 ns pulse width, at a 100 Hz repetition rate. Creating a sealed Titanium unit, capable of operation on the extreme environment of Titan’s surface was a major engineering challenge. The laser successfully demonstrated its ability to meet all operational requirements in terms of pulse energy, beam pointing on target and repeatability even after extensive environmental testing.

Matthew W Mullin↗

Performance of the Dragonfly Mass Spectrometer (DraMS) Programmable UV Laser Source Engineering Test Unit (ETU)

NASA’s Dragonfly mission will sample surface materials from multiple sites on Saturn’s largest moon, Titan, in exploration of its potential for prebiotic chemistry. We report on the performance of our short-pulsed UV laser transmitter, developed for the Dragonfly’s on-board Mass Spectrometer (DraMS). Our engineering test unit (ETU) has completed flight qualification and demonstrated its operational science requirements, such that the final flight unit build can begin. The Titan Hydrocarbon Analysis Nanosecond Optical Source (THANOS) ETU laser produces 266 nm laser pulses at programmable energy levels in order to create high resolution laser desorption mass spectrometry (LDMS) measurements. The laser operates in short bursts of 1-50 pulses, each at < 2 ns pulse width, at a 100 Hz repetition rate. Creating a sealed Titanium unit, capable of operation on the extreme environment of Titan’s surface was a major engineering challenge. The laser successfully demonstrated its ability to meet all operational requirements in terms of pulse energy, beam pointing on target and repeatability even after extensive environmental testing.

Matthew Mullin↗

Response of Venus exospheric temperature measured by neutral mass spectrometer to solar EUV flux measured by Langmuir probe on the Pioneer Venus orbiter

The photoelectron current from the Pioneer Venus Langmuir probe has provided measurements of the total flux of solar EUV photons at Venus since 1979. The neutral oxygen scale height measured by the orbiter neutral mass spectrometer has permitted the exospheric temperature to be derived during the same mission. In this paper, the EUV observations are used to examine the response of exospheric temperature to changes in solar activity, primarily those related to solar rotation. It is found that the dayside exospheric temperature quite faithfully tracks variations in the EUV flux. Comparison is also made with the earth-based solar activity index F10.7 adjusted to the position of Venus. This index varied from 142 to 249 flux units during the period of measurements. The exospheric temperature is better correlated with EUV flux than with the 10.7-cm solar radio flux.

Mahajan, K. K.↗

Radiation Design of Ion Mass Spectrometers

In the harsh radiation environment of Jupiter and with the JUpiter ICy moon Explorer (JUICE) mission including two Europa flybys where local intensities are approx. 150 krad/month behind 100 mils of Al shielding, so background from penetrating radiation can be a serious issue for detectors inside an Ion Mass Spectrometer (IMS). This can especially be important for minor ion detection designs. Detectors of choice for time-of-flight (TOF) designs are microchannel plates (MCP) and some designs may include solid state detectors (SSD). The standard approach is to use shielding designs so background event rates are low enough that the detector max rates and lifetimes are first not exceeded and then the more stringent requirement that the desired measurement can successfully be made (i.e., desired signal is sufficiently greater than background noise after background subtraction is made). GEANT codes are typically used along with various electronic techniques, but such designs need to know how the detectors will respond to the simulated primary and secondary radiations produced within the instrument. We will be presenting some preliminary measurements made on the response of MCPs to energetic electrons (20 ke V to 1400 ke V) using a Miniature TOF (MTOF) device and the High Energy Facility at Goddard Space Flight Center which has a Van de Graaff accelerator.

Sittler, Ed↗

Monte Carlo simulations in support of the Shuttle upper atmospheric mass spectrometer experiment

This paper presents the results of calculations obtained with a Direct Simulation Monte Carlo (DSMC) method that describes both the external flow about the nose region of the Shuttle Orbiter and the internal flow in an inlet tube that provides the initial path between the shock-processed gases and a mass spectrometer mounted inside the Orbiter. A dedicated, three-dimensional version of the DSMC was developed during this study for the internal flow simulation along with the procedure for interfacing the external and internal flows. The calculations span the 140 to 95 km altitude range, which includes most of the hypersonic transitional flow encountered during reentry. All calculations were for a multicomponent gas mixture consisting of five chemical species while simulating the effects of transitional, rotational, vibrational, and chemical nonequilibrium. The results of the calculations show that within the entry region of the inlet tube where the gas has equilibrated with the sidewall tube temperature, the pressure is substantially less than the pressure at the external surface. This pressure correction for the entry region is significant for all conditions investigated and increases with altitude. The results highlight the structure of both the external and internal flow. Results of parametric studies show the sensitivity of the equilibrated inlet sidewall pressure to mass flow rates, gas-surface reflection model, tube side-wall temperature variations, and surface recombinations.

Moss, J. N.↗

Ion mass spectrometer experiment for ISIS-2 spacecraft

The International Satellite for Ionospheric Studies (ISIS) program of NASA was the longest duration program in NASA history. A number of satellites were flown under this program, the last being called ISIS-2, which was launched on April 1, 1971 and operated successfully for over 13 years. An experiment called the Ion Mass Spectrometer (IMS) was flown on the ISIS-2 spacecraft. It operated for 10 years providing a large data base of positive ion composition and ion flow velocities along the orbit of the satellite, the latter being circular at 1400 km with a 90 degree inclination. The data were processed and reside in the National Space Sciences Data Center.

Hoffman, John H.↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bayesian Model for HOPE Mass Spectrometers on Van Allen Probes

Space instruments rely heavily on modeling to predict and understand the instrument response, enabling a determination of the capabilities and resolution. The Bayesian approach provides a framework to incorporate prior knowledge and propagate uncertainty to predict the instrument response. We present an empirical Bayes model for the end-to-end performance of the Helium, Oxygen, Proton, and Electron mass spectrometers aboard the Van Allen Probes mission. In this model, we use a combination of external modeling, laboratory calibration, and expert opinion to construct the time-of-flight spectra and demonstrate good agreement with on-orbit data. The empirical Bayes model is applied to explore doubly charged ions and carbon, nitrogen, oxygen discrimination during the Van Allen Probes mission.

47 OTHER INSTRUMENTATION↗

A preliminary investigation into the feasibility of laser ablation U–Pb isotope ratio measurement via all‐faraday cup detection with 10 11 ‐ and 10 13 ‐Ω amplifiers on the Neoma multicollector‐inductively coupled plasma‐mass spectrometer

Rationale Signal detection for uranium–lead (U–Pb) dating of zircon is typically performed via ion counters. Here, we develop a preliminary understanding of the strengths and limitations of faraday‐cup‐based detection. Methods A suite of zircon reference materials and the NIST‐610 glass were sampled using laser ablation followed by U–Pb isotope ratio measurement on a Neoma multicollector‐inductively coupled plasma‐mass spectrometer. Results We were able to produce geologically accurate 207 Pb/ 206 Pb, 206 Pb/ 238 U, and 207 Pb/ 235 U ratios for the NIST‐610 glass and the zircon standards, with ages ranging from ~2.5 Ga to ~337 Ma (TanBrown A, Oracle, 91550, Mud Tank, Temora, and Plešovice). Two of the younger zircon standards examined (94‐35, ~55.6 Ma, and Fish Canyon, 28.6 Ma) yielded accurate 206 Pb/ 238 U but not 207 Pb/ 235 U or 207 Pb/ 206 Pb ratios, whereas the youngest zircon standard (Penglai, ~4.4 Ma) failed for all three ratios of interest. The accuracy and precision of the all‐faraday method are directly tied to signal intensity, with reliable data capable of being produced even when both isotopes in a ratio have signals below ~0.001 V (equivalent to ~62 500 cps on an ion counter). Conclusion The all‐faraday cup multicollection method provides sufficient sensitivity to obtain geologically meaningful U–Pb data, with possible advantages being that laser pit depth‐dependent changes in the observed interelemental fractionation behavior may be easier to correct using a static collector configuration compared to when the ion beam is swept across a single detector while also removing the need for an interdetector‐type calibration. Further work is needed to refine the all‐faraday cup method (e.g., application of background subtraction and common Pb corrections, outlier removal, and interelement as well as down‐hole fractionation corrections), but our initial results demonstrate that the faraday detector method has sufficient sensitivity to warrant further study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration and Ruggedization of a Commercially Available Gas Chromatograph and Mass Spectrometer (GCMS) for the Resource Prospector Mission (RPM)

The Resource Prospector is a mission to prospect for lunar volatiles (primarily water) at one of the two lunar poles, as well as demonstrate In-Situ Resource Utilization (ISRU) on the Moon. The Resource Prospector consists of a lander, a rover, and a rover-borne scientific payload. The Regolith and Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) payload, will be able to (1) locate near subsurface volatiles, (2) excavate and analyze samples of the volatile-bearing regolith, and (3) demonstrate the form, extractability and usefulness of the materials. The gas chromatograph mass spectrometer (GCMS) is the primary instrument in the RESOLVE instrumentation suite responsible for identification and quantification of the volatiles evolved from the lunar regolith. Specifically, this instrument must have: a low mass, a low power consumption, be able to perform fast analyses of samples ranging from less than one to greater than ninety nine percent water by mass, be autonomously controlled by the payload's software and avionics platform, and be able to operate in the harsh lunar environment. The RPM's short mission duration is the primary driver of the requirement for a very fast analysis time currently base lined at less than 2 minutes per sample. This presentation will discuss the requirements levied upon the GCMS design, lessons learned from a preliminary field demonstration deployment, the current design, and the path forward.

Loftin, Kathleen↗

Integration and Ruggedization of a Commercially Available Gas Chromatograph and Mass Spectrometer (GCMS) for the Resource Prospector Mission (RPM)

The Resource Prospector is a mission to prospect for lunar volatiles (primarily water) at one of the two lunar poles, as well as demonstrate In-Situ Resource Utilization (ISRU) on the Moon. The Resource Prospector consists of a lander, a rover, and a rover-borne scientific payload. The Regolith and Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) payload, will be able to (1) locate near subsurface volatiles, (2) excavate and analyze samples of the volatile-bearing regolith, and (3) demonstrate the form, extractability and usefulness of the materials. The gas chromatograph mass spectrometer (GCMS) is the primary instrument in the RESOLVE instrumentation suite responsible for identification and quantification of the volatiles evolved from the lunar regolith. Specifically, this instrument must have: a low mass, a low power consumption, be able to perform fast analyses of samples ranging from less than one to greater than ninety nine percent water by mass, be autonomously controlled by the payload's software and avionics platform, and be able to operate in the harsh lunar environment. The RPM's short mission duration is the primary driver of the requirement for a very fast analysis time currently base lined at less than 2 minutes per sample. This presentation will discuss the requirements levied upon the GCMS design, lessons learned from a preliminary field demonstration deployment, the current design, and the path forward.

Loftin, Kathleen↗

Phoenix Lander's Thermal Evolved Gas Analyzer: Differential Scanning Calorimeter and Mass Spectrometer Database Development

The Mars Scout Phoenix lander will land in the north polar region of Mars in May, 2008. One objective of the Phoenix lander is to search for evidence of past life in the form of molecular organics that may be preserved in the subsurface soil. The Thermal Evolved Gas Analyzer (TEGA) was developed to detect these organics by coupling a simultaneous differential thermal analyzer (SDTA) with a mass spectrometer. Martian soil will be heated to approx.1000 C and potential organic decomposition products such as CO2, CH4 etc. will be examined for with the MS. TEGA s SDTA will also assess the presence of endothermic and exothermic reactions that are characteristic of soil organics and minerals as the soil is heated. The MS in addition to detecting organic decompositon products, will also assess the levels of soil inorganic volatiles such as H2O, SO2, and CO2. Organic detection has a high priority for this mission; however, TEGA has the ability to provide valuable insight into the mineralogical composition of the soil. The overall goal of this work is to develop a TEGA database of minerals that will serve as a reference for the interpretation of Phoenix-TEGA. Previous databases for the ill-fated Mars Polar Lander (MPL)-TEGA instrument only went to 725 C. Furthermore, the MPL-TEGA could only detect CO2 and H2O while the Phoenix-TEGA MS can examine up to 144 atomic mass units. The higher temperature Phoenix-TEGA SDTA coupled with the more capable MS indicates that a higher temperature database is required for TEGA interpretation. The overall goal of this work is to develop a differential scanning calorimeter (DSC) database of minerals along with corresponding MS data of evolved gases that can used to interpret TEGA data during and after mission operations. While SDTA and DSC measurement techniques are slightly different (SDTA does not use a reference pan), the results are fundamentally similar and thus DSC is a useful technique in providing comparative data for the TEGA database. The objectives of this work is to conduct DSC and MS analysis up to 1000 C of select minerals that may be found in the martian soil.

Sutter, B.↗