Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical Impedance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Performance Assessment of Photovoltaic Panels Using Impedance Spectroscopy

The goal of this project was to develop a technique for measuring internal characteristics of a PV module using light modulation under a fixed voltage bias while measuring the resulting alternating current. This technique, light-intensity modulated impedance spectroscopy (LIMIS), has the promise of detecting early signs of panel aging and degradation that could be used for example by solar farm operators to have early warnings to repair or replace panels to maintain reliability of the overall PV array. LIMIS would be complementary with the previously developed electrochemical impedance spectroscopy (EIS), which uses an alternating voltage applied electrically to a solar cell with a similar alternating current measurement. EIS has mostly been developed for individual PV cells rather than whole modules. The project was intended to assess what different information could be revealed by LIMIS, which may in some cases be more scalable to larger modules and potentially more practical to apply in field measurements without needing to electrically disconnect PV modules. We began with small 10 W PV modules and built a testbed capable of oscillating the light intensity with frequencies up to 50 kHz. In parallel, we built a large testbed for testing large 250 W PV modules. Meanwhile, we developed procedures for established measurement techniques: current–voltage (I–V), EIS, and electroluminescence (EL) imaging, where panels are subjected to forward bias while their infrared emission is recorded using a camera modified to be sensitive to IR wavelengths. In addition, we developed protocols for accelerated aging of PV modules in two ways. Thermal cycling from –40°C to +90°C simulates the diurnal temperature cycles on a rooftop. Mechanical stress by dropping a 227 g ball from a height of 1 m simulates damage such as that due to hail impacts.

14 SOLAR ENERGY↗

Mechanisms of blood pressure regulation that differ in men repeatedly exposed to high-G acceleration

The purpose of this study was to test the hypothesis that repeated exposure to high acceleration (G) would be associated with enhanced functions of specific mechanisms of blood pressure regulation. We measured heart rate (HR), stroke volume (SV), cardiac output (), mean arterial blood pressure, central venous pressure, forearm and leg vascular resistance, catecholamines, and changes in leg volume (%DeltaLV) during various protocols of lower body negative pressure (LBNP), carotid stimulation, and infusions of adrenoreceptor agonists in 10 males after three training sessions on different days over a period of 5-7 days using a human centrifuge (G trained). These responses were compared with the same measurements in 10 males who were matched for height, weight, and fitness but did not undergo G training (controls). Compared with the control group, G-trained subjects demonstrated greater R-R interval response to equal carotid baroreceptor stimulation (7.3 +/- 1.2 vs. 3.9 +/- 0.4 ms/mmHg, P = 0.02), less vasoconstriction to equal low-pressure baroreceptor stimulation (-1.4 +/- 0.2 vs. -2.6 +/- 0.3 U/mmHg, P = 0.01), and higher HR (-1.2 +/- 0.2 vs. -0.5 +/- 0.1 beats. min(-1). mmHg(-1), P = 0.01) and alpha-adrenoreceptor response (32.8 +/- 3.4 vs. 19.5 +/- 4.7 U/mmHg, P = 0.04) to equal dose of phenylephrine. During graded LBNP, G-trained subjects had less decline in and SV, %DeltaLV, and elevation in thoracic impedance. G-trained subjects also had greater total blood (6,497 +/- 496 vs. 5,438 +/- 228 ml, P = 0.07) and erythrocyte (3,110 +/- 364 vs. 2,310 +/- 96 ml, P = 0.06) volumes. These results support the hypothesis that exposure to repeated high G is associated with increased capacities of mechanisms that underlie blood pressure regulation.

Non-NASA Center↗

In situ x-ray imaging to understand subsurface behavior during continuous wave laser drilling

A limited understanding regarding the underlying dynamics and mechanisms of material removal during continuous wave laser drilling has presented significant challenges in achieving precision and process control. Here, to address this, we employed high-fidelity, in situ synchrotron x-ray imaging to reveal previously unknown material behaviors during continuous wave laser drilling with power modulation. Our findings highlight that high-aspect ratio drill holes are achieved when the laser modulation frequency falls within the range of 8–12 kHz, provided that the laser average power and modulation amplitude levels meet the specified limits. Under these conditions, we identified a material removal mechanism driven by incremental accumulation of recoil pressure that gradually pushes material upward from deep within the substrate to the surface. This mechanism manifested as a low-frequency fluctuation in the vapor depression depth, resulting in periodic instances of material ejection. Furthermore, our study underscores that rapid expansion of the melt pool and the widening of the drill hole opening can impede effective material removal by redirecting energy from material ejection to increasing the melt pool size. This investigation contributes essential insights into the subsurface dynamics involved in the drilling of high-aspect ratio holes, furthering our fundamental understanding of this intricate process.

47 OTHER INSTRUMENTATION↗

Long-Term Performance of Ag/AgCl Reference Electrodes for Corrosion Potential Monitoring in Radioactive Tank Waste at the Hanford Site

This work studied the exposure effects of radioactive tank waste on the long-term performance of single junction Ag/AgCl reference electrodes for corrosion potential monitoring at the Hanford Site. Electrodes from three manufacturers with very different designs were studied using open-circuit potential and electrochemical impedance measurements in radioactive tank waste. Post-test analyses were conducted on some failed electrodes using destructive and nondestructive techniques. The intrusion of the aggressive and radioactive chemicals in tank waste through the porous frit materials was the primary mechanism that led to the clogging of frit, physical and chemical degradation of AgCl bonded to Ag wire, and alteration of the internal electrolyte. Radiolytic chemical species such as H2O2 and HNO3 may have also induced the degradation of the Ag wire. The extent of electrode degradation and failure probability highly depended on the electrode design and environmental conditions. Chemicals in tank waste had stronger effects than radiation on the long-term performance of the Ag/AgCl reference electrodes.

Materials Science↗

Particle Access and Charging Environments in the Lunar Wake

A plasma wake a region of low density, high temperature plasma forms on the far side of the Moon when solar wind, magnetosheath, and magnetotail plasma flows past the Moon [Manka, 1973; Ogilvie et al., 1996; Farrell et al., 1998; Halekas et al., 2005]. Ion populations in these flows typically have much smaller thermal velocity than bulk speed and are therefore excluded from the plasma wake while the large thermal electron velocity allows the lighter negatively charged particles to stream ahead of the ions into the wake. Charge separation due to electrons streaming ahead of the ions into the wake from the wake boundary establishes an ambipolar electric field which impedes the motion of electron flow and accelerates ions into the wake [Ogilvie et al., 1996; Farrell et al., 1997]. We have conducted a theoretical study of acceleration (and deceleration) of charged particles in lunar plasma environments, which investigated the mechanisms responsible for allowing solar wind entry into the lunar wake, and for producing energetic particle distributions observed within the lunar wake. To this end, the investigation utilized a macroscale 3D hybrid particle-in-cell numerical model of the interaction of the Moon with external plasma environments to compute electric fields in the lunar environment for a variety of external plasma conditions and interplanetary magnetic field orientations. Ion dynamics were attained from the hybrid code while electron dynamics were determined by considering electron test particle trajectories through the fields established in the hybrid code. Results from the code will be presented to evaluate charging environments within the lunar wake.

Parker, Linda↗

Prototyping of a Rotary Triboelectric Nanogenerator for Power at Sea

Increasing at-sea power generation by Triboelectric Nanogenerator (TENG) energy harvesters towards the order of 1-Watt will create significant opportunities to power ocean observation buoys and distributed sensor nodes by extending mission time and increasing sensor payload. Of the many possible configurations of harvesting wave energy with TENGs, we document the rationale for choosing and developing a rotary TENG that operates by the freestanding mode. The rotary TENG prototype consists of two plates, a rotor and a stator, to take advantage of the various mechanisms of converting wave action into rotational motion. We have constructed a testing apparatus that allows us to vary several key parameters of the device: distance between rotor and stator, triboelectric material, rotational speed, number of electrodes and output load impedance. Preliminary results show that when driven at a constant 500 rpm, we can achieve a power density of 0.7 W/m3. A variable speed motor drives the rotor, which can be driven using a velocity profile informed by the equivalent to the output from a wave energy converter (WEC). The optimized rotational TENG can be stacked and driven by a single shaft, increasing the energy density of the device. The output of such a TENG could be used to power devices in the ocean at a low cost and high durability.

electrostatic generator↗

Contact Resistance of Carbon–Li x (Ni,Mn,Co)O 2 Interfaces

Abstract Electronic resistance in lithium‐ion battery positive electrodes is typically attributed to the bulk resistance of the active material and the network resistance of the carbon additive. Expected overpotentials from these bulk components are minimal relative to that from charge‐transfer resistance. However, literature reports show that cell overpotentials are often much more sensitive to conductive additives than the expected level from bulk or percolating‐network transport. This discrepancy motivated a detailed examination of the contact resistance between the active material and conductive additive. The contact and bulk resistances are simultaneously measured using dense bar samples of lithium‐layered oxides (Li x Ni 1 /3 Mn 1/3 Co 1/3 O 2 and Li x Ni 0.5 Mn 0.3 Co 0.2 O 2 ) in contact with carbon black. It is found that the contact resistance dominates the overall electronic resistance when the length scale is smaller than millimeters; after correcting for contact effects, bulk conductivity of layered oxides is determined to be orders‐of‐magnitude higher than previously reported. In porous electrodes, it is found from three‐electrode electrochemical impedance spectroscopy that the carbon content most heavily influences the low‐frequency regime (≈0.01 Hz), as opposed to the high frequency (>10 3 Hz) regime expected from electronic percolating properties. Constriction effects within the layered oxide are identified as the dominant mechanism for contact resistance and its implication is investigated for porous electrodes.

Kuo, Jimmy Jiahong↗

Unified Ultrasonic/Eddy-Current Data Acquisition

Imaging station for detecting cracks and flaws in solid materials developed combining both ultrasonic C-scan and eddy-current imaging. Incorporation of both techniques into one system eliminates duplication of computers and of mechanical scanners; unifies acquisition, processing, and storage of data; reduces setup time for repetitious ultrasonic and eddy-current scans; and increases efficiency of system. Same mechanical scanner used to maneuver either ultrasonic or eddy-current probe over specimen and acquire point-by-point data. For ultrasonic scanning, probe linked to ultrasonic pulser/receiver circuit card, while, for eddy-current imaging, probe linked to impedance-analyzer circuit card. Both ultrasonic and eddy-current imaging subsystems share same desktop-computer controller, containing dedicated plug-in circuit boards for each.

Chern, E. James↗

Tuned Reactivity at the Lithium Metal–Argyrodite Solid State Electrolyte Interphase

Thin intermetallic Li 2 Te–LiTe 3 bilayer (0.75 µm) derived from 2D tellurene stabilizes the solid electrolyte interphase (SEI) of lithium metal and argyrodite (LPSCl, Li 6 PS 5 Cl) solid-state electrolyte (SSE). Tellurene is loaded onto a standard battery separator and reacted with lithium through single-pass mechanical rolling or transferred directly to SSE surface by pressing. State-of-the-art electrochemical performance is achieved, e.g., symmetric cell stable for 300 cycles (1800 h) at 1 mA cm -2 and 3 mAh cm -2 (25% DOD, 60 µm foil). Cryo-stage focused ion beam (Cryo-FIB) sectioning and Raman mapping demonstrate that the Li 2 Te–LiTe 3 bilayer impedes SSE decomposition. The unmodified Li–LPSCl interphase is electrochemically unstable with a geometrically heterogeneous reduction decomposition reaction front that extends deep into the SSE. Decomposition drives voiding in Li metal due to its high flux to the reaction front, as well as voiding in the SSE due to the associated volume changes. Analysis of cycled SSE found no evidence for pristine (unreacted) lithium metal filaments/dendrites, implying failure driven by decomposition phases with sufficient electrical conductivity that span electrolyte thickness. In conclusion, DFT calculations clarify thermodynamic stability, interfacial adhesion, and electronic transport properties of interphases, while mesoscale modeling examines interrelations between reaction front heterogeneity (SEI heterogeneity), current distribution, and localized chemo-mechanical stresses.

25 ENERGY STORAGE↗

Laser pulse-length dependent ablation and shock generation in silicon at 5 × 10 14 W/ cm 2 intensities

The effect of laser pulse duration on energy coupling into a planar silicon target is investigated in experiments at the OMEGA-EP facility by varying the laser pulse length τ —spanning 3 orders of magnitude from 100 ps to 10 ns—while maintaining a constant peak laser intensity, I 0 = 5 × 10 14 W/ cm 2 . In theoretical models, the ablation pressure primarily scales for a given material with laser intensity and wavelength, which are all fixed variables here, allowing us to explore the specific role of laser pulse duration. Two-dimensional radiation-hydrodynamics simulations benchmarked with optical probing of the expanding plasma show that the pulse duration is critical for the ablation pressure to reach a steady state. Moreover, the pulse duration impacts shock decay and multiple wave effects, which strongly dictate the evolving shock profile that propagates within the laser-shocked target as ultimately measured by rear-surface diagnostics. The shock velocities inferred from the theoretical model, after considering shock decay, impedance matching, and shock Hugoniot, are found to be in good agreement with velocimetry measurements. However, discrepancies are observed with simulations for the shorter (0.1 ns) and longer (10 ns) pulse durations, which are respectively attributed to unaccounted contributions of kinetic absorption mechanisms and instabilities in simulations. Published by the American Physical Society 2024

Bailly-Grandvaux, M. (ORCID:0000000175294013)↗

Digital Distributed Parameter Model for Analysis of Unsteady Flow in Liquid-Filled Lines

A distributed parameter model for computing unsteady flow conditions in liquid systems is presented. The model is adapted for use in conjunction with a digital computer. The analytical method employed is essentially a solution synthesized from the effects of incremental step pressure pulses. The pressure pulses are generated because of incremental flow-rate changes that originate in a fluid system from a variety of sources, including the mechanical motion of the system structure. The pressure pulses propagate throughout the system at sonic velocity and are partially transmitted and reflected at each discontinuity. The velocity change caused by each pressure pulse is obtained from the relation for the characteristic acoustic impedance. Pressure and velocity time histories at any point in the system are obtained by a timewise summation of the contributions of the incremental pressure pulses passing that point. The analysis is presented in a form general enough to be applied to a variety of liquid-filled fluid systems. To illustrate the application of the method to a specific system, the response of a long, straight propellant line to a sinusoidal inlet flow and pressure perturbation is computed. Both a constant-cross-section line and a tapered line are analyzed in the example.

UNSTEADY FLOW↗

An Impedance Humidity Sensor Based on CVD Grown WSe 2 2D Films

2D materials-based planar devices have been sought after for gas and humidity sensor applications owing to their high sensitivity due to their ultrathin nature and increased surface area. Herein, 2D WSe 2 films-based planner devices were fabricated to evaluate their performance for potential application in humidity sensors. The structure and morphology of the WSe 2 sensing films were studied by Raman spectroscopy, photoluminescence, optical microscopy, and scanning electron microscopy (SEM) techniques. The relative humidity-dependent sensing performances of the 2D WSe 2 films were evaluated using current–voltage (I–V), relative impedance, and complex total impedance (electrochemical impedance spectroscopy, EIS) techniques. This sensor showed a very stable and repeatable performance investigated over the period of 18 months. The response and recovery times of the WSe 2 -based impedance sensors were found to be 40 and 30 s, respectively. The WSe 2 sensor exhibits a 2 ± 1% minimum hysteresis at a lower humidity level (50% RH) and around 8 ± 2% maximum hysteresis at relative humidity level (70% RH). This value of hysteresis is in the acceptable range during the initial investigation of any material to explore its potential for application in humidity sensors. The density functional theory (DFT) analysis was performed with the interaction from water molecules of the WSe 2 sample for a better understanding of the sensing mechanism of devices.

2D- WSe2↗

ACS Spotlight: Bipolar Membranes for Electrochemical Energy Conversion, Chemical Manufacturing, and Separations

Sustainable energy conversion, chemical manufacturing, and separations are central to addressing the world’s energy and environmental challenges. Electrochemical platforms stand as a cornerstone in addressing these challenges because they are low exergy and can be powered on renewable electrons. In electrochemical systems, bipolar membranes (BPMs) are emerging as a unique class of ion exchange membranes poised to revolutionize various electrochemical processes via pH control of anode and cathode chambers and in situ pH adjustment. In this Spotlight Review, we provide a comprehensive review of electrochemical platforms utilizing BPMs for energy conversion (water electrolyzers for hydrogen production, fuel cells, and flow batteries), chemical manufacturing (electrolyzers that convert carbon dioxide into value-added chemicals and nitrate into ammonia), and separations. The motivation for using BPMs, as well as their performance and durability, in electrochemical platforms are disseminated. We also discuss current challenges that impede BPM electrochemical systems from competing with state-of-the-art electrochemical systems using monopolar ion-exchange membranes (e.g., anion/hydroxide exchange membranes and cation/proton exchange membranes). Here, the review also covers molecular modeling and continuum modeling efforts to understand the basic mechanisms that govern BPM performance.

30 DIRECT ENERGY CONVERSION↗

Extending Calendar Life of Si-Based Lithium-Ion Batteries by a Localized High Concentration Electrolyte

Silicon (Si) is one of the most promising anode materials for the next generation lithium-ion batteries (LIBs). Although significant progresses have been made on the cycle life of Si-based LIBs, their calendar-life is still far less than those required for electrical vehicle applications. Here, in this work, the fundamental mechanisms behind the limited calendar life of Si-LIBs have been investigated. It is found that the unstable interphase layers formed on electrodes during the formation/cycling of batteries using conventional electrolyte with fluoroethylene carbonate (FEC) additive are responsible for the rapid impedance-increase of Si-LIBs during storage at elevated temperature (55°C). By using an FEC-free localized high concentration electrolyte (lithium bis(fluorosulfonyl)imide:ethyl propionate:ethylene carbonate:1,1,2,2-tetrafluoroethyl-2,2,3,3-tetrafluoropropyl ether (1:2.8:0.2:1 by mol.) with 1 wt.% lithium difluorophosphate), stable interphase layers formed on electrodes can effectively block the crosstalk between cathode and anode, minimize the impedance increase of Si||LiNi 0.6 Mn 0.2 Co 0.2 (NMC622) batteries during storage at elevated temperature (55°C), therefore largely improve their calendar life. Si||NMC622 batteries using this electrolyte also demonstrated a high-capacity retention of ~92.4% after 500 cycles at 45°C with well-preserved electrode structure. Hence, this novel electrolyte is a good candidate to extend the cycling life and calendar life of Si-LIBs.

25 ENERGY STORAGE↗

Bridging the Gap from Networking Technologies to Applications: Workshop Report

The objective of the Next Generation Internet (NGI) Federal program is threefold, encompassing development of networking technologies, high-performance network testbeds, and revolutionary applications. There have been notable advances in emerging network technologies and several nationwide testbeds have been established, but the integration of emerging technologies into applications is lagging. To help bridge this gap between developers of NGI networking technologies and developers of NGI applications, the NASA Research and Education Network (NREN) project hosted a two-day workshop at NASA Ames Research Center in August 1999. This paper presents a summary of the results of this workshop and also describes some of the challenges NREN is facing while incorporating new technologies into HPCC and other NASA applications. The workshop focused on three technologies - Quality of Service (QoS), advanced multicast, and security-and five major NGI application areas - telemedicine, digital earth, digital video, distributed data-intensive applications, and computational infrastructure applications. Network technology experts, application developers, and NGI testbed representatives came together at the workshop to promote cross-fertilization between the groups. Presentations on the first day, including an overview of the three technologies, application case studies and testbed status reports, laid the foundation for discussions on the second day. The objective of these latter discussions, held within smaller breakout groups, was to establish a coherent picture of the current status of the various pieces of each of the three technologies, to create a roadmap outlining future technology development, and to offer technological guidance to application developers. In this paper we first present a brief overview of the NGI applications that were represented at the workshop, focusing on the identification of technological advances that have successfully been incorporated in each application and technological challenges that remain. Next we present the technology roadmaps that were created at the workshop, summarizing the status of various mechanisms that are currently under development and forecasting when various advances are likely to occur within the next one-to-three-year time span. Then we identify issues that were raised at the workshop that might hinder technology development or that might impede integration into NGI applications. We also report some specific guidelines that were offered at the workshop to enable application developers to integrate and effectively use emerging NGI technology building blocks. Finally, we describe NREN activities to incorporate emerging technologies into NASA applications. These activities include support for other NASA High-Performance Computing and Communications Program areas such as IPG (Information Power Grid), support for NASA science enterprises such as Earth science and Mars program prototyping activities, support for satellite/terrestrial networking applications such as the TransAtlantic and TransPacific demonstrations and the Interplanetary Internet, support for NASA telemedicine applications such as the Virtual Collaborative Clinic, and participation in NGI advanced technology testbed initiatives such as the QBone and the NTON/Supernet. For each activity we highlight the primary technological challenge that is associated with it.

Johnson, Marjory J.↗

Low Cost Beam-Steering Approach for a Series-Fed Array

Phased array antennas showcase many advantages over mechanically steered systems. However, they are also more complex and costly. This paper presents a concept which overcomes these detrimental attributes by eliminating all of the phased array backend (including phase shifters). Instead, a propagation constant reconfigurable transmission line in a series fed array arrangement is used to allow phase shifting with one small (less than or equal to 100mil) linear mechanical motion. A novel slotted coplanar stripline design improves on previous transmission lines by demonstrating a greater control of propagation constant, thus allowing practical prototypes to be built. Also, beam steering pattern control is explored. We show that with correct choice of line impedance, pattern control is possible for all scan angles. A 20 element array scanning from -25 deg less than or equal to theta less than or equal to 21 deg. with mostly uniform gain at 13GHz is presented. Measured patterns show a reduced scan range of 12 deg. less than or equal to theta less than or equal to 25 deg. due to a correctable manufacturing error as verified by simulation. Beam squint is measured to be plus or minus 2.5 deg for a 600MHz bandwidth and cross-pol is measured to be at least -15dB.

Transmission line↗