At least 415 records · Page 23

Statistical Analysis of Inter-Area Oscillations in the U.S. Eastern Interconnection: A 2017-2023 Perspective

Recent advancements and the accumulation of high-resolution, long-term phasor measurement unit (PMU) data have provided detailed insights into inter-area oscillations in power grids. This study conducts a comprehensive statistical analysis of inter-area oscillations within the United States Eastern Interconnection from 2017 to 2023. Utilizing data captured by the advanced wide-area Frequency Monitoring Network (FNET/GridEye), this investigation examines the occurrence patterns, dominant frequencies, damping ratios, and excitation mechanisms of these oscillations. Our analysis sheds light on the evolving statistical behaviors of inter-area oscillations, offering updated and critical information for grid operators and planners. The insights gained from this study can be instrumental in enhancing the operational resilience of the power network and guiding strategic developments in grid infrastructure to accommodate future challenges. Additionally, the study discusses emerging challenges associated with the modernization of the power grid, including increased renewable penetration, dynamic load variability, and cyber-physical vulnerabilities that complicate oscillation monitoring and control.

Inter-area oscillations↗

MODELING A SPENT NUCLEAR FUEL CASK SEISMIC TEST

The US Department of Energy Spent Fuel and Waste Science and Technology (SFWST) program is planning to conduct a series of full-scale shake table tests to simulate hypothetical earthquake conditions and record the response of surrogate spent nuclear fuel (SNF) assemblies in a canister dry storage system mockup. The shake table motions will represent a range of hypothetical earthquake conditions at hypothetical locations in the continental US to generally define the range of mechanical loads that SNF can be expected to experience during extended dry storage periods. The earthquake conditions will represent seismic hazards in the 2,000-to-20,000-year return period range. The test will use instrumented pressurized water reactor fuel assemblies with surrogate mass inside the fuel rods instead of radioactive fuel pellets. Dummy assemblies with similar mass and dimensions to actual fuel assemblies will occupy the rest of the fuel assembly locations in a SNF canister that holds 32 fuel assemblies. The canister will be located inside a mockup vertical concrete cask. Instrumentation will record the motion of the major components of the complex dynamic system, and strain gauges will be used to record the cladding strain at select locations. Preparations for the test require modeling predictions to identify the range of response of the system and to help select specific earthquake cases to be simulated on the shake table from a large set of potential cases. This paper describes the pretest nonlinear finite element modeling efforts that have been completed to date, including cask system level modeling and fuel assembly modeling in LS-DYNA. The cask system level models are critical for anticipating sliding or tipping of an unanchored cask during the test. The fuel assembly model is needed to estimate the range of cladding strain response and fuel assembly structural response to be expected during the test and cladding strain measurements will be key metrics for model validation and the development of modeling best practices after the test is concluded.

Klymyshyn, Nicholas A.↗

Real-time machine-learning-driven control system of a deformable mirror for achieving aberration-free X-ray wavefronts

A neural-network machine learning model is developed to control a bimorph adaptive mirror to achieve and preserve aberration-free coherent X-ray wavefronts at synchrotron radiation and free electron laser beamlines. The controller is trained on a mirror actuator response directly measured at a beamline with a real-time single-shot wavefront sensor, which uses a coded mask and wavelet-transform analysis. The system has been successfully tested on a bimorph deformable mirror at the 28-ID IDEA beamline of the Advanced Photon Source at Argonne National Laboratory. It achieved a response time of a few seconds and maintained desired wavefront shapes (e.g., a spherical wavefront) with sub-wavelength accuracy at 20 keV of X-ray energy. This result is significantly better than what can be obtained using a linear model of the mirror’s response. The developed system has not been tailored to a specific mirror and can be applied, in principle, to different kinds of bending mechanisms and actuators.

47 OTHER INSTRUMENTATION↗

Detection, monitoring, and determination of location of changes in metallic structures using multimode acoustic signals

Methods for detection, monitoring, and determination of location of changes in rigid structures with arbitrarily complex geometries are described. Implementations include locating acoustic transducers that generate and receive acoustic signals at multiple locations along a surface of the rigid structure, wherein longitudinal spacing between the transducer locations define measurement zones. Acoustic signals with chosen amplitude-time-frequency characteristics excite multiple vibration modes in the structure within each zone. Small mechanical changes in the inspection zones lead to scattering and attenuation of broadband acoustic signals, which are detectable as changes in received signal characteristics as part of a through-transmission technique. Additional use of short, narrowband pulse acoustic signals as part of a pulse-echo technique allows determination of the relative location of the mechanical change within each zone based on the differential delay profiles.

42 ENGINEERING↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An absolute recoil-carbon polarimeter for polarized light-ions at the BNL Booster

We describe a recoil-carbon polarimeter for the BNL Booster synchrotron capable of measuring the transverse polarization of both the polarized proton beam and the polarized 3 He ion beam throughout the acceleration cycle. The instrument addresses a critical gap in the BNL polarized beam program: no independent polarization measurement currently exists in the injector chain between the 200 MeV Linac polarimeter and the AGS. The proposed new polarimeter will provide continuous, absolute polarization measurements at the Booster stage, supplying additional anchor points for the polarization transmission through the accelerator chain. The polarimeter 9 is based on elastic pC and 3 He C scattering from a thin internal carbon target, with detection of the recoil 12 C nucleus in a fixed six-station silicon detector ring. A single detector geometry provides continuous kinematic coverage from injection to extraction for both beam species without mechanical adjustment. For pC scattering, the available data and the Bonin parametrization provide a well-established basis for estimating the analyzing power and figure of merit over the Booster energy range; for 3 He C the sole experimental anchor is a measurement at 443 MeV, and the Booster polarimeter itself is identified as the instrument to map the analyzing power across the remainder of the acceleration ramp by a ramp-and-return calibration that anchors the absolute 3 He polarization scale to a few percent. Provision for future deuteron polarimetry is incorporated in the chamber design without modification to the existing geometry. With appropriate detector upgrades, the same recoil-carbon technique can be extended to deuteron beams, for which analyzing power data are already available, and, with future analyzing-power measurements, also to 6 Li and 7 Li beams, making the polarimeter a versatile instrument for the full range of light polarized ion species anticipated at BNL.

43 PARTICLE ACCELERATORS↗

Operando X-ray absorption spectroscopic investigation of electrocatalysts state in anion exchange membrane fuel cells

Capturing the active state of (electro)catalysts under operating conditions, namely operando, is the ultimate objective of (electro)catalyst characterization, enabling the unraveling of reaction mechanisms and advancing (electro)catalyst development. Operando insights advance our understanding of the correlations between electrochemical tests and device-level performances. However, operando characterization of electrocatalysts is challenging due to the complexity of electrochemical devices and instrumental limitations. As a result, the majority of electrocatalyst characterizations have been limited to half-cell in situ studies. Here, we present an operando X-ray absorption spectroscopic study of Mn spinel oxide electrocatalysts in an operating fuel cell employing a custom-designed cell. Our results reveal that in anion exchange membrane fuel cells, the Mn valence state, within spinel Mn 3 O 4 /C, increases to above 3+, adopting an octahedral coordination devoid of Jahn-Teller distortions. This structural change results in an AEMFC performance equivalent to that of Co 1.5 Mn 1.5 O 4 /C, a composition that outperforms Mn 3 O 4 /C in rotating disk electrode tests. Our results underscore the importance of operando characterizations in elucidating the active state of electrocatalysts and understanding the correlation(s) between electrochemical tests and device performance.

Electrocatalysis↗

Top-down proteomics

Proteoforms arising from posttranslational modifications, genetic polymorphisms, and RNA splice variants, play a pivotal role as the key drivers in biology. Thus, a comprehensive understanding of proteoforms is essential for unraveling the intricacies of biological systems and bridging the gap between genotype and phenotype. By analyzing whole proteins without digestion, top-down proteomics (TDP) provides a holistic view of the proteome and presents a next-generation approach for deciphering protein function, uncovering disease mechanisms, and advancing precision medicine. This Primer embarks on a journey into the world of TDP by encapsulating its historical context, underlying principles, recent advances, and an outlook on the future of TDP. The experimental section navigates instrumentation, sample preparation, intact protein separation, tandem mass spectrometry techniques, and data collection. Results decipher raw data, visualize intact protein spectra, unravel data analysis, and explain proteoform identification, characterization, and quantitation, as well as statistical analysis. Various applications of TDP spanning the human proteoform project, biomedical, biopharmaceutical, and clinical applications are described. These are complemented by discussions on measurement reproducibility, limitations, and a forward-looking perspective outlining uncharted waters where the field can advance, and potential exciting future applications of TDP.

Roberts, David S.↗

Superconducting microwave cavities and qubits for quantum information systems

Superconducting microwave cavities featuring ultrahigh Q-factors, which measure the efficiency of energy storage in relation to energy loss in a system, are revolutionizing quantum computing by providing long coherence times exceeding 1 ms, crucial for the development of scalable multi-qubit quantum systems with low error rates. Here, in this work, we provide an in-depth analysis of recent advances in ultrahigh Q-factor cavities, integration of Josephson junction-based qubits, and bosonic-encoded qubits in 3D cavities. We examine the sources of quantum state dephasing caused by damping and noise mechanisms in cavities and qubits, highlighting the critical challenges that need to be addressed to achieve even higher coherence times. We critically survey the latest progress made in implementing single 3D qubits using superconducting materials, normal metals, and multi-qubit and multi-state quantum systems. Our work sheds light on the promising future of this research area, including novel materials for cavities and qubits, modes with nontrivial topological properties, error correction techniques for bosonic qubits, and new light–matter interaction effects.

3D printing↗

Biofouling of filtration membranes in wastewater reuse: In situ visualization with confocal laser scanning microscopy

The filtration membranes utilized in advanced treatment of municipal wastewater are prone to biological fouling. Permeability loss and water recovery limitations due to fouling necessitate additional pretreatment and membrane cleaning, which raise the cost of water reuse. Better fouling mitigation calls for a deeper understanding of biofilm behavior on water reuse membranes. This study uses confocal microscopy to monitor biofouling under realistic conditions. To simulate water reuse, a miniature flow cell with microfiltration and ultrafiltration membranes was operated under typical filtration conditions using secondary effluent from California's East Bay Municipal Utility District. The growing biofilms were stained for extracellular polymeric substances and live and dead cells, and they were monitored in situ under filtration conditions with a confocal laser scanning microscope to produce 2-D and 3-D images. In situ image series revealed biofilm growth and removal processes including internal and external fouling, extracellular polymeric substance production, wrinkling, delamination, and film re-deposition. Additionally, changes in biofilm morphology between in situ and ex situ images highlighted limitations of ex situ imaging. Here, these results provide insight into the physical and biological mechanisms of biofouling in hopes of informing the development of improved techniques for biofouling mitigation.

ultrafiltration↗

Influence of Silane Coupling Agents on Filler Network Structure and Stress-Induced Particle Rearrangement in Elastomer Nanocomposites

Filled rubber materials are key in many technologies having broad impact on the economy and sustainability, the most obvious being tire technology. Adding filler dramatically improves the strength of rubber by reinforcement and tailoring the type of filler and the chemistry of the interface between filler and rubber matrix is important for optimizing performance metrics such as fuel efficiency. In a highly loaded, silica-filled, crosslinked model rubber closely mimicking commercial materials, both the filler network structure and the dynamics of the silica filler particles change when the silica surface is modified with silane coupling agents. Reduction in size scales characteristic of the structure are quantified using ultra-small-angle X-ray scattering (USAXS) measurements and the particle dynamics probed with X-ray photon correlation spectroscopy (XPCS). While the structure averaged over the scattering volume changes little with aging after step strain, the dynamics slow appreciably in a manner that varies with the treatment of the silica filler. The evolution of filler particle dynamics depends on the chemical functionality at the silica surface and observing these differences suggests a way of thinking about the origins of hysteresis in nanoparticle-reinforced rubbers. These microscopic filler dynamics are correlated with the macroscopic stress relaxation of the filled materials. The combination of static and dynamic X-ray scattering techniques with rheological measurements is a powerful approach for elucidating the microscopic mechanisms of rubber reinforcement.

36 MATERIALS SCIENCE↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

Lorentz symmetry fractionalization and dualities in (2+1)d

We discuss symmetry fractionalization of the Lorentz group in (2+1) d d non-spin quantum field theory (QFT), and its implications for dualities. We prove that two inequivalent non-spin QFTs are dual as spin QFTs if and only if they are related by a Lorentz symmetry fractionalization with respect to an anomalous \mathbb{Z}_2 ℤ 2 one-form symmetry. Moreover, if the framing anomalies of two non-spin QFTs differ by a multiple of 8, then they are dual as spin QFTs if and only if they are also dual as non-spin QFTs. Applications to summing over the spin structures, time-reversal symmetry, and level/rank dualities are explored. The Lorentz symmetry fractionalization naturally arises in Chern-Simons matter dualities that obey certain spin/charge relations, and is instrumental for the dualities to hold when viewed as non-spin theories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Length and Seed Current Scaling of a Mark X HG driven, 8 inch PBX9501 RancheroS FCG system: II

This report is intended to examine the ultimate operating limits of the combined Pt. 88 capacitor bank (CB) + MarkX Helical Generator (HG) driving a RancheroS Flux Compression Generator (FCG) with various physics experiment load inductances. As such, many degradation mechanisms are neglected in this study. In actual use, degradation of the HG output current delivered to the FCG will probably occur. Internal changes in the HG can occur due to both Ohmic heating in the generator leading to a time varying series resistance [R(t)] such as that seen in the first trial (Shot 0) of the MarkX, as well as any misbehavior, such HG internal turn to turn shorts such as seem to have occurred in subsequent MarkX tests. Both reduce the output current from the HG that is used to seed the FCG. The results discussed here are intended to probe the limits of the RancheroS driving various loads, in an ideal situation in which none of the HG or system degradation mechanisms prior to the FCG armature first motion (FM) reduce the seed current. The HG is modeled simply as a time varying inductance [L(t), as measured in Shot 0], with a constant internal resistance [R(t) = 0.2mOhm]. The RancheroS itself is fully modeled, including all FCG and load degradation mechanisms, thus probing the ultimate capabilities of the full system, independent of problems upstream of the FCG.

47 OTHER INSTRUMENTATION↗

Imaging Carrier Dynamics and Transport in Hybrid Perovskites with Transient Absorption Microscopy

In this review, the recent progress in using transient absorption microscopy to image charge transport and dynamics in semiconducting hybrid organic–inorganic perovskites is discussed. The basic principles, instrumentation, and resolution of transient absorption microscopy are outlined. With temporal resolution as high as 10 fs, sub-diffraction-limit spatial resolution, and excited-state structural resolution, these experiments have provided crucial details on charge transport mechanisms that have been previously obscured in conventional ultrafast spectroscopy measurements. Morphology-dependent mapping unveils spatial heterogeneity in carrier recombination and cooling dynamics. By spatially separating the pump and probe beams, carrier transport across grain boundaries has been directly visualized. Further, femtosecond temporal resolution allows for the examination of nonequilibrium transport directly, revealing extraordinarily long-range hot carrier migration. The application of transient absorption microscopy is not limited to hybrid perovskites but can also be useful for other polycrystalline materials in which morphology plays an important role in carrier transport.

36 MATERIALS SCIENCE↗

Laser-driven ramp-compression experiments on the national ignition facility

This report details the analyses and related uncertainties in measuring longitudinal-stress–density paths in indirect laser-driven ramp equation-of-state (EOS) experiments. Experiments were conducted at the National Ignition Facility (NIF) located at the Lawrence Livermore National Laboratory. The NIF can deliver up to 2 MJ of laser energy over 30 ns and provide the necessary laser power and control to ramp compress materials to TPa pressures (1 TPa = 10 × 10 6 atmospheres). These data provide low-temperature solid-state EOS data relevant to the extreme conditions found in the deep interiors of giant planets. In these experiments, multi-stepped samples with thicknesses in the range of 40–120 µm experience an initial shock compression followed by a time-dependent ramp compression to peak pressure. Interface velocity measurements from each thickness combine to place a constraint on the Lagrangian sound speed as a function of particle velocity, which in turn allows for the determination of a continuous stress–density path to high levels of compressibility. In this report, we present a detailed description of the experimental techniques and measurement uncertainties and describe how these uncertainties combine to place a final uncertainty in both stress and density. Here, we address the effects of time-dependent deformation and the sensitivity of ramp EOS techniques to the onset of phase transformations.

47 OTHER INSTRUMENTATION↗

High-Performance Atomically-Thin Room-Temperature NO 2 Sensor

The development of room-temperature sensing devices for detecting small concentrations of molecular species is imperative for a wide range of low-power sensor applications. Here, we demonstrate a room-temperature, highly sensitive, selective, and reversible chemical sensor based on a monolayer of the transition metal dichalcogenide Re 0.5 Nb 0.5 S 2 . The sensing device exhibits thickness dependent carrier type, and upon exposure to NO 2 molecules, its electrical resistance considerably increases or decreases depending on the layer number. The sensor is selective to NO 2 with only minimal response to other gases such as NH 3 , CH 2 O, and CO 2 . In the presence of humidity, not only are the sensing properties not deteriorated, but also the monolayer sensor shows complete reversibility with fast recovery at room temperature. We present a theoretical analysis of the sensing platform and identify the atomically-sensitive transduction mechanism.

47 OTHER INSTRUMENTATION↗