Search NASA⌕ Search

SEARCH · Search NASA

Results for “Modal Test and Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Simulated rotor test apparatus dynamic characteristics in the 80- by 120-foot wind tunnel

A shake test was conducted in the 80 by 120 foot Wind Tunnel at NASA Ames Research Center, using a load frame and dummy weights to simulate the weight of the NASA Rotor Test Apparatus. The simulated hub was excited with broadband random excitation, and accelerometer responses were measured at various locations. The transfer functions (acceleration per unit excitation force as a function of frequency) for each of the accelerometer responses were computed, and the data were analyzed using modal analysis to estimate the model parameters.

Hoque, M. S.↗

Ground vibration test of the XV-15 Tiltrotor Research Aircraft and pretest predictions

The first comprehensive ground vibration survey was performed on the XV-15 Tiltrotor Research Aircraft to measure the vibration modes of the airframe and to provide data critical for determining whirl flutter stability margins. The aircraft was suspended by the wings with bungee cords and cables. A NASTRAN finite element model was used in the design of the suspension system to minimize its interference with the wing modes. The primary objective of the test was to measure the dynamic characteristics of the wings and pylons for aeroelastic stability analysis. In addition, over 130 accelerometers were placed on the airframe to characterize the fuselage, wing, and tail vibration. Pretest predictions were made with the NASTRAN model as well as correlations with the test data. The results showed that the suspension system provided the isolation necessary for modal measurements.

Studebaker, Karen↗

Design of a Test Article and Test Facility to Investigate Flow-Induced Vibration of a Helical Coil Steam Generator

NuScale Power LLC (NuScale) is developing a small modular reactor (SMR) with unique design features and arrangements that require testing to provide quality data for safety analysis codes and design validation, as well as for technology maturation. A multi-phase testing program is underway at NuScale to demonstrate that its unique helical coil steam generator design is not susceptible to flow-induced vibration during operation. The phases of the testing program include modal testing of individual tubes during test article fabrication and modal and flow testing after test article completion. NuScale has contracted SIET S.p.A. in Piacenza, Italy for the design and fabrication of the test article and test facility. In-fabrication testing was performed at the site of test article build in Cremosano, Italy. Modal testing and flow testing of the completed test article will be performed at SIET’s facilities in Piacenza. This paper discusses the design of the test article and test facility, including supporting systems, required to generate the quality data required to support NuScale’s comprehensive vibration assessment program as part of the overall licensing effort for NuScale’s first-of-a-kind small modular light water reactor.

Flow-induced vibration, helical coil, steam genera↗

Machine Learning Enabled Sensor Fusion for In-Situ Defect Detection in Laser Powder Bed Fusion

Laser Powder Bed Fusion (L-PBF) Additive Manufacturing (AM) is among the metal 3D printing technologies most broadly adopted by the manufacturing industry. The current industry qualification paradigm for critical-application L-PBF parts relies heavily on expensive non-destructive inspection techniques such as X-Ray Computed Tomography (XCT), which significantly limits the use-cases of L-PBF. In situ monitoring of the process promises a less expensive alternative to ex situ testing, but existing sensor technologies and data analysis techniques struggle to detect sub-surface flaws (e.g., porosity and cracking) on production-scale L-PBF printers. RTX Technologies Research Center (RTRC) has licensed ORNL’s Peregrine software package – a printer- and camera-agnostic data analytics tool designed specifically for detecting process anomalies using in situ data collected during powder bed printing. The goal of this project was to feed temporally rich, multi-modal sensor data, including visible light, integrated near infrared (NIR), and spatially mapped co-axial melt pool thermal emission data into Peregrine to enable detection of subsurface flaws. XCT data was used as ground truth training data to allow Peregrine’s deep learning algorithms to recognize anomalies in these complex data streams in both test artifacts and industrially relevant geometries. Completion of this program has seen the successful implementation of multi-modal, multi-layer sensor data footprints for training of machine learning models in Peregrine. Flaws detected in XCT data have been successfully detected directly from this in situ data footprint, and initial analyses of the in situ probability-of-detection has been conducted, showing performance levels commensurate with traditional non-destructive evaluation (NDE) methods. The in situ monitoring methodology was then applied to an industrially relevant component that was using post-build NDE, highlighting the utility of the proposed method for hard-to-inspect AM components. As a direct result of this program, two journal manuscripts [1], [2] have been published in Additive Manufacturing, with additional manuscripts planned following program completion.

36 MATERIALS SCIENCE↗

COVID-19 prevention at institutions of higher education, United States, 2020–2021: implementation of nonpharmaceutical interventions

Background, In early 2020, following the start of the coronavirus disease 2019 (COVID-19) pandemic, institutions of higher education (IHEs) across the United States rapidly pivoted to online learning to reduce the risk of on-campus virus transmission. We explored IHEs’ use of this and other nonpharmaceutical interventions (NPIs) during the subsequent pandemic-affected academic year 2020–2021. Methods, From December 2020 to June 2021, we collected publicly available data from official webpages of 847 IHEs, including all public (n = 547) and a stratified random sample of private four-year institutions (n = 300). Abstracted data included NPIs deployed during the academic year such as changes to the calendar, learning environment, housing, common areas, and dining; COVID-19 testing; and facemask protocols. We performed weighted analysis to assess congruence with the October 29, 2020, US Centers for Disease Control and Prevention (CDC) guidance for IHEs. For IHEs offering ≥50% of courses in person, we used weighted multivariable linear regression to explore the association between IHE characteristics and the summated number of implemented NPIs. Results, Overall, 20% of IHEs implemented all CDC-recommended NPIs. The most frequently utilized NPI was learning environment changes (91%), practiced as one or more of the following modalities: distance or hybrid learning opportunities (98%), 6-ft spacing (60%), and reduced class sizes (51%). Additionally, 88% of IHEs specified facemask protocols, 78% physically changed common areas, and 67% offered COVID-19 testing. Among the 33% of IHEs offering ≥50% of courses in person, having < 1000 students was associated with having implemented fewer NPIs than IHEs with ≥ 1000 students. Conclusions, Only 1 in 5 IHEs implemented all CDC recommendations, while a majority implemented a subset, most commonly changes to the classroom, facemask protocols, and COVID-19 testing. IHE enrollment size and location were associated with degree of NPI implementation. Additional research is needed to assess adherence to NPI implementation in IHE settings.

59 BASIC BIOLOGICAL SCIENCES↗

NXIS - Well integrity inspection in unconventional gas wells

The objective of this project is to advance the state-of-the-art and to develop an integrity inspection system capable of detecting physical flaws in the wellbore structure of conventional and unconventional hydrocarbon producing wells. Measuring the integrity of multiple wellbore casings and cement annuli for onshore and offshore wells remains a challenging task. We propose a multi-modality inspection system composed of neutron and X(gamma)-ray imaging modalities (nXis) to address the above challenge. The functional principle of this wellbore integrity inspection system is the combination of high-energy modalities, such as X(gamma)-ray and neutron backscatter imaging, with conventional low-energy modalities, such as electromagnetic or ultrasound imaging techniques. By combining multiple sensing modalities into one sensing system and by fusing data between modalities, one can gather more information about the integrity of the wellbore structure compared to simply using multiple sensors individually. Imaging prototypes for gamma, neutron, and electromagnetics were designed, manufactured, and tested at GE Global Research and Starfire Industries. Wellbore phantoms with engineered defects were manufactured and the performance of the developed wellbore integrity inspection tool prototypes was evaluated in a test pit test at an industrial GE Oil & Gas facility. Data analysis and fusion between various inspection techniques show enhanced defect detectability. These exciting results were presented at various technical conferences and discussed with operators in the oil & gas industry. Great interest from oil operators lead to discussions about joint industrial partnerships to move the developed technology from the prototype phase to the product phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-218: Novel Validation Paradigm of MRI to CT Deformation of Prostate

Purpose: Deformable registration algorithms are inherently difficult to characterize in the multi-modality setting due to a significant differences in the characteristics of the different modalities (CT and MRI) as well as tissue deformations. We present a unique paradigm where this is overcome by utilizing a planning-MRI acquired within an hour of the planning-CT serving as a surrogate for quantifying MRI to CT deformation by eliminating the issues of multi-modality comparisons. Methods: For nine subjects, T2 fast-spin-echo images were acquired at two different time points, the first several weeks prior to planning (diagnostic-MRI) and the second on the same day as the planning-CT (planning-MRI). Significant effort in patient positioning and bowel/bladder preparation was undertaken to minimize distortion of the prostate in all datasets. The diagnostic-MRI was rigidly and deformably aligned to the planning-CT utilizing a commercially available deformable registration algorithm synthesized from local registrations. Additionally, the quality of rigid alignment was ranked by an imaging physicist. The distances between corresponding anatomical landmarks on rigid and deformed registrations (diagnostic-MR to planning-CT) were evaluated. Results: It was discovered that in cases where the rigid registration was of acceptable quality the deformable registration didn’t improve the alignment, this was true of all metrics employed. If the analysis is separated into cases where the rigid alignment was ranked as unacceptable the deformable registration significantly improved the alignment, 4.62mm residual error in landmarks as compared to 5.72mm residual error in rigid alignments with a p-value of 0.0008. Conclusion: This paradigm provides an ideal testing ground for MR to CT deformable registration algorithms by allowing for inter-modality comparisons of multi-modality registrations. Consistent positioning, bowel and bladder preparation may Result in higher quality rigid registrations than typically achieved which limits the impact of deformable registrations. In this study cases where significant differences exist, deformable registrations provide significant value.

60 APPLIED LIFE SCIENCES↗

Test of a model for trace element partition during closed-system solidification of a silicate liquid

Trace-element concentrations in separated minerals and rock fragments from a coarsely crushed and sieved sample of medium-grained lunar basalt are determined by high-precision instrumental neutron activation analysis for three main purposes. These are: (1) to test a previously proposed model for describing trace-element behavior during solidification of a silicate liquid under conditions of a closed system; (2) to compare trace-element concentrations among different size fractions of a comminuted basalt; and (3) to investigate small-scale heterogeneity within a single medium-grained basalt. It is found that an excellent mass balance for the whole rock is attained in terms of the trace-element concentrations of the component minerals and mesostasis, that the mixing model describing this mass balance yields a superior modal analysis for the whole rock, and that different size fractions of the coarsely crushed basalt vary in mineral composition. The closed-system model is shown to account properly for the average behavior of the trace elements during solidification of the basalt, and values of distribution coefficients are obtained for incompatible elements in that rock.

Haskin, L. A.↗

Modal vector estimation for closely spaced frequency modes

Techniques for obtaining improved modal vector estimates for systems with closely spaced frequency modes are discussed. In describing the dynamical behavior of a complex structure modal parameters are often analyzed: undamped natural frequency, mode shape, modal mass, modal stiffness and modal damping. From both an analytical standpoint and an experimental standpoint, identification of modal parameters is more difficult if the system has repeated frequencies or even closely spaced frequencies. The more complex the structure, the more likely it is to have closely spaced frequencies. This makes it difficult to determine valid mode shapes using single shaker test methods. By employing band selectable analysis (zoom) techniques and by employing Kennedy-Pancu circle fitting or some multiple degree of freedom (MDOF) curve fit procedure, the usefulness of the single shaker approach can be extended.

Craig, R. R., Jr.↗

SU-E-T-01: (In)dependence of Plan Quality On Treatment Modalities and Target-To-Critical Structure Geometry for Brain Tumor

Purpose: To evaluate and test the hypothesis that plan quality may be systematically affected by treatment delivery techniques and target-tocritical structure geometric relationship in radiotherapy for brain tumor. Methods: Thirty-four consecutive brain tumor patients treated between 2011–2014 were analyzed. Among this cohort, 10 were planned with 3DCRT, 11 with RadipArc, and 13 with helical IMRT on TomoTherapy. The selected dosimetric endpoints (i.e., PTV V100, maximum brainstem/chiasm/ optic nerve doses) were considered as a vector in a highdimensional space. A Pareto analysis was performed to identify the subset of Pareto-efficient plans.The geometric relationships, specifically the overlapping volume and centroid-of-mass distance between each critical structure to the PTV were extracted as potential geometric features. The classification-tree analyses were repeated using these geometric features with and without the treatment modality as an additional categorical predictor. In both scenarios, the dominant features to prognosticate the Pareto membership were identified and the tree structures to provide optimal inference were recorded. The classification performance was further analyzed to determine the role of treatment modality in affecting plan quality. Results: Seven Pareto-efficient plans were identified based on dosimetric endpoints (3 from 3DCRT, 3 from RapicArc, 1 from Tomo), which implies that the evaluated treatment modality may have a minor influence on plan quality. Classification trees with/without the treatment modality as a predictor both achieved accuracy of 88.2%: with 100% sensitivity and 87.1% specificity for the former, and 66.7% sensitivity and 96.0% specificity for the latter. The coincidence of accuracy from both analyses further indicates no-to-weak dependence of plan quality on treatment modality. Both analyses have identified the brainstem to PTV distance as the primary predictive feature for Pareto-efficiency. Conclusion: Pareto evaluation and classification-tree analyses have indicated that plan quality depends strongly on geometry for brain tumor, specifically PTV-tobrain-stem-distance but minimally on treatment modality.

60 APPLIED LIFE SCIENCES↗

Development and evaluation of the impulse transfer function technique

The development of the test/analysis technique known as the impulse transfer function (ITF) method is discussed. This technique, when implemented with proper data processing systems, should become a valuable supplement to conventional dynamic testing and analysis procedures that will be used in the space shuttle development program. The method can relieve many of the problems associated with extensive and costly testing of the shuttle for transient loading conditions. In addition, the time history information derived from impulse testing has the potential for being used to determine modal data for the structure under investigation. The technique could be very useful in determining the time-varying modal characteristics of structures subjected to thermal transients, where conventional mode surveys are difficult to perform.

Mantus, M.↗

Medical ultrasonic tomographic system

An electro-mechanical scanning assembly was designed and fabricated for the purpose of generating an ultrasound tomogram. A low cost modality was demonstrated in which analog instrumentation methods formed a tomogram on photographic film. Successful tomogram reconstructions were obtained on in vitro test objects by using the attenuation of the fist path ultrasound signal as it passed through the test object. The nearly half century tomographic methods of X-ray analysis were verified as being useful for ultrasound imaging.

Heyser, R. C.↗

Optical fiber sensors and signal processing for intelligent structure monitoring

The analytic and experimental performance of optical fiber sensors for the control of vibration of large aerospace and other structures are investigated. In particular, model domain optical fiber sensor systems, are being studied due to their apparent potential as distributed, low mass sensors of vibration over appropriate ranges of both low frequency and low amplitude displacements. Progress during the past three months is outlined. Progress since September is divided into work in the areas of experimental hardware development, analytical analysis, control design and sensor development. During the next six months, tests of a prototype closed-loop control system for a beam are planned which will demonstrate the solution of several optical fiber instrumentation device problems, the performance of the control system theory which incorporates the model of the modal domain sensor, and the potential for distributed control which this sensor approach offers.

Rogowski, Robert↗

Nondestructive Structural Damage Detection in Flexible Space Structures Using Vibration Characterization

Spacecraft are susceptible to structural damage over their operating life from impact, environmental loads, and fatigue. Structural damage that is not detected and not corrected may potentially cause more damage and eventually catastrophic structural failure. NASA's current fleet of reusable spacecraft, namely the Space Shuttle, has been flown on several missions. In addition, configurations of future NASA space structures, e.g. Space Station Freedom, are larger and more complex than current structures, making them more susceptible to damage as well as being more difficult to inspect. Consequently, a reliable structural damage detection capability is essential to maintain the flight safety of these structures. Visual inspections alone can not locate impending material failure (fatigue cracks, yielding); it can only observe post-failure situations. An alternative approach is to develop an inspection and monitoring system based on vibration characterization that assesses the integrity of structural and mechanical components. A methodology for detecting structural damage is presented. This methodology is based on utilizing modal test data in conjunction with a correlated analytical model of the structure to: (1) identify the structural dynamic characteristics (resonant frequencies and mode shapes) from measurements of ambient motions and/or force excitation; (2) calculate modal residual force vectors to identify the location of structural damage; and (3) conduct a weighted sensitivity analysis in order to assess the extent of mass and stiffness variations, where structural damage is characterized by stiffness reductions. The approach is unique from other existing approaches in that varying system mass and stiffness, mass center locations, the perturbation of both the natural frequencies and mode shapes, and statistical confidence factors for structural parameters and experimental instrumentation are all accounted for directly.

Ricles, James M.↗

Structural-acoustic coupling in aircraft fuselage structures

Results of analytical and experimental investigations of structural-acoustic coupling phenomenon in an aircraft fuselage are described. The structural and acoustic cavity modes of DC-9 fuselage were determined using a finite element approach to vibration analysis. Predicted structural and acoustic dispersion curves were used to determine possible occurrences of structural-acoustic coupling for the fuselage. An aft section of DC-9 aircraft fuselage, housed in an anechoic chamber, was used for experimental investigations. The test fuselage was excited by a shaker and vibration response and interior sound field were measured using accelerometer and microphone arrays. The wavenumber-frequency structural and cavity response maps were generated from the measured data. Analysis and interpretation of the spatial plots and wavenumber maps provided the required information on modal characteristics, fuselage response and structural-acoustic coupling.

Mathur, Gopal P.↗

Sensor-Only System Identification for Structural Health Monitoring of Advanced Aircraft

Environmental conditions, cyclic loading, and aging contribute to structural wear and degradation, and thus potentially catastrophic events. The challenge of health monitoring technology is to determine incipient changes accurately and efficiently. This project addresses this challenge by developing health monitoring techniques that depend only on sensor measurements. Since actively controlled excitation is not needed, sensor-to-sensor identification (S2SID) provides an in-flight diagnostic tool that exploits ambient excitation to provide advance warning of significant changes. S2SID can subsequently be followed up by ground testing to localize and quantify structural changes. The conceptual foundation of S2SID is the notion of a pseudo-transfer function, where one sensor is viewed as the pseudo-input and another is viewed as the pseudo-output, is approach is less restrictive than transmissibility identification and operational modal analysis since no assumption is made about the locations of the sensors relative to the excitation.

Kukreja, Sunil L.↗

Uncertainty Quantification of Inducer Natural Frequency using Conditional Assessment of Modeling and Modal Testing of Simpler Systems

The low pressure fuel pump inducer of the new Space Launch System RS25 core stage engine operates in a highly complex environment that substantially affects its modal characteristics. Some of the more important effects are fluid-added mass resulting from operation within a light liquid (Hydrogen), and the magnification of this effect due to tight tip clearance. Since higher order cavitation has been identified as a significant harmonic driver, knowledge of the natural frequency of potentially excitable modes is critical for safe operation, but this frequency cannot be measured during the severe operational environment. A comprehensive testing and analysis program has therefore been performed over the last four years to identify the nominal value and uncertainty of the frequency by modeling and testing four simpler structures which share some of the characteristics of the operational inducer. This testing was used to assess and adjust modeling techniques and excellent correlation was achieved. Identification of the uncertainty in the inducer frequency itself was still problematic, however. This difficulty led to an investigation of Bayesian uncertainty quantification techniques, and to the application of the relatively simple technique of Multi-Variate Normal conditional distributions to calculate the inducer natural frequency uncertainty. Assumptions on prior distributions of uncertainty of the fluid-added mass and tip clearance effect are initially applied to models of each of the simple structures and the inducer itself, and these uncertainties are propagated to generate natural frequencies using design of experiments. Simple response surfaces are then created from this data in order to calculate a Covariance Matrix relating all of these natural frequencies. Finally, the results from modal test of the simple structures are considered to be observations and used to calculate the conditional variance of the desired inducer frequencies. As this method is less rigorous than more complicated Bayesian methods reported in the literature, a conservative factor is applied to the result, but the resulting uncertainty is still significantly less than originally estimated and will greatly assist certification of the inducer for use in the engine.

Uncertainty Quantification↗

Uncertainty Quantification of Inducer Eigenvalues using Conditional Assessment of Models and Modal Test of Simpler Systems

The low pressure fuel pump inducer of the new Space Launch System RS25 core stage engine operates in a highly complex environment that substantially affects its modal characteristics. Some of the more important effects are fluid-added mass resulting from operation within a light liquid (Hydrogen), and the magnification of this effect due to tight tip clearance. Since higher order cavitation has been identified as a significant harmonic driver, knowledge of the natural frequency of potentially excitable modes is critical for safe operation, but this frequency cannot be measured during the severe operational environment. A comprehensive testing and analysis program has therefore been performed over the last four years to identify the nominal value and uncertainty of the frequency by modeling and testing four simpler structures which share some of the characteristics of the operational inducer. This testing was used to assess and adjust modeling techniques and excellent correlation was achieved. Identification of the uncertainty in the inducer frequency itself was still problematic, however. This difficulty led to an investigation of Bayesian uncertainty quantification techniques, and to the application of the relatively simple technique of Multi-Variate Normal conditional distributions to calculate the inducer natural frequency uncertainty. Assumptions on prior distributions of uncertainty of the fluid-added mass and tip clearance effect are initially applied to models of each of the simple structures and the inducer itself, and these uncertainties are propagated to generate natural frequencies using design of experiments. Simple response surfaces are then created from this data in order to calculate a Covariance Matrix relating all of these natural frequencies. Finally, the results from modal test of the simple structures are considered to be observations and used to calculate the conditional variance of the desired inducer frequencies. As this method is less rigorous than more complicated Bayesian methods reported in the literature, a conservative factor is applied to the result, but the resulting uncertainty is still significantly less than originally estimated and will greatly assist certification of the inducer for use in the engine.

Uncertainty Quantification↗