Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Monte Carlo simulation of order-disorder transition in refractory high entropy alloys: A data-driven approach

High entropy alloys (HEAs) are a series of novel materials that demonstrate many exceptional mechanical properties. To understand the origin of these attractive properties, it is important to investigate the thermodynamics and elucidate the evolution of various chemical phases. In this work, we introduce a machine learning approach to construct the effective Hamiltonian and study the thermodynamics of HEAs through canonical Monte Carlo simulation. The main characteristic of our method is to use pairwise interactions between atoms as the machine learning features and systematically improve the representativeness of the dataset using active learning from the Monte Carlo samples. We find this method produces highly robust and accurate effective Hamiltonians that give less than 0.1 mRy test error for all the three refractory HEAs: MoNbTaW, MoNbTaVW, and MoNbTaTiW. Using replica exchange to speed up the MC simulation, we calculated the specific heats and short-range order parameters in a wide range of temperatures. For all the studied materials, we find there are two major order-disorder transitions occurring respectively at T 1 and T 2 , where T 1 is near room temperature but T 2 is much higher. Further, we demonstrate that the transition at T 1 is caused by W and Nb while the one at T 2 is caused by the other elements. By comparing with experiments, the results demonstrate that the order-disorder transitions have a profound impact on the strength and ductility of HEAs.

36 MATERIALS SCIENCE↗

Fe-vacancy ordering in superconducting K 1– x Fe 2– y Se 2 : First-principles calculations and Monte Carlo simulations

Fe vacancies in the 33 K superconductor K 1–x Fe 2–y Se 2 show ordering schemes that may be correlated with its superconducting properties. First-principles calculations and kinetic Monte Carlo simulations lead to a very simple model for vacancy ordering. Repulsive dipolar interactions between Fe vacancies show three ground states: a $\sqrt{8}\times \sqrt{10}$ rhombus-ordered structure for 12.5% vacancies, a $\sqrt{5}\times \sqrt{5}$ squared lattice for 20% vacancies, and a $\sqrt{5}\times \sqrt{5}$ rhombus-ordered structure for 25% vacancies. Other structural states are derived from these three ground states and may contain additional disordered spatial regions. As a result, the repulsive interaction between Fe vacancies arises from enhanced Fe–Se covalent bonds, which differs from the well-known attractive interaction of Fe vacancies in body-centered cubic Fe.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental results and numerical modeling of a high-performance large-scale cryopump. I. Test particle Monte Carlo simulation

For the torus of the nuclear fusion project ITER (originally the International Thermonuclear Experimental Reactor, but also Latin: the way), eight high-performance large-scale customized cryopumps must be designed and manufactured to accommodate the very high pumping speeds and throughputs of the fusion exhaust gas needed to maintain the plasma under stable vacuum conditions and comply with other criteria which cannot be met by standard commercial vacuum pumps. Under an earlier research and development program, a model pump of reduced scale based on active cryosorption on charcoal-coated panels at 4.5 K was manufactured and tested systematically. The present article focuses on the simulation of the true three-dimensional complex geometry of the model pump by the newly developed ProVac3D Monte Carlo code. It is shown for gas throughputs of up to 1000 sccm ({approx}1.69 Pa m{sup 3}/s at T = 0 deg. C) in the free molecular regime that the numerical simulation results are in good agreement with the pumping speeds measured. Meanwhile, the capture coefficient associated with the virtual region around the cryogenic panels and shields which holds for higher throughputs is calculated using this generic approach. This means that the test particle Monte Carlo simulations in free molecular flow can be used not only for the optimization of the pumping system but also for the supply of the input parameters necessary for the future direct simulation Monte Carlo in the full flow regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of the maximum energy loss for electron stopping power calculations and its effect on backscattering electron yield in Monte-Carlo simulations applying continuous slowing-down approximation

The maximum energy loss for electron stopping power calculations by the full Penn algorithm within the dielectric formalism is determined with taking into account the contribution of electron and plasmon excitations. Use of these calculated electron stopping powers in Monte Carlo simulations applying continuous slowing down approximation gives the backscattering electron yields in much better agreement with experimental data than previous other theoretical results. The muffin-tin model is used to describe the electron elastic scattering by atom bound in solids with taking into account the exchange correlation and polarization effect.

36 MATERIALS SCIENCE↗

First-principles-based Kinetic Monte Carlo Simulation of Nitric Oxide Reduction over Platinum Nanoparticles under Lean-burn Conditions

The kinetics of NO reduction over platinum nanoparticles under lean-burn condition was investigated by first-principles-based kinetic Monte Carlo simulations. Three-dimensional model platinum nanoparticles with diameters ranging from 2.29 to 4.61 nm were represented by a truncated octahedron model consisting of a single (100) facet and eight (111) facets. First-principles density functional theory (DFT) calculations were used to determine the intrinsic kinetic parameters including the binding energies for all of the surface intermediates as well as the activation barriers and reaction energies that comprise the reaction mechanism over the (100) facet, the (111) facet and the (111)/(100) edge sites on the three-dimension nanoparticle. Both intra- and inter- facet diffusion of adsorbates were included to model mass transport over the particle surface. The simulation results show that in the presence of excess oxygen, NO reduction to N2 occurs only on the (100) facets. The oxidation of NO to NO2, while much more favored on the (111) facets, can occur on both (100) and (111) facets. Only small amounts of N2O form over the (100) facet. The apparent activation energies for N2 and NO2 formation over the overall particle are 45 kJ/mol and 42 kJ/mol, respectively. This is in agreement with previous experiments. Particle size effects on the activities of NO reduction and oxidation depend on the atomic fractions of the (100) and the (111) facets exposed on the platinum nanoparticles. For the three-dimensional model platinum nanoparticles examined here, the atomic fraction of the (100) facet is nearly the same while the atomic fraction of the (111) facet increases with the increasing particle size. As a result, the activity of NO reduction is insensitive to the particle size. While the larger particle shows higher activity for NO oxidation thus elucidating previous experimental observations. Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo simulation based study of a proposed multileaf collimator for a telecobalt machine

Purpose: The objective of the present work was to propose a design of a secondary multileaf collimator (MLC) for a telecobalt machine and optimize its design features through Monte Carlo simulation. Methods: The proposed MLC design consists of 72 leaves (36 leaf pairs) with additional jaws perpendicular to leaf motion having the capability of shaping a maximum square field size of 35 Multiplication-Sign 35 cm{sup 2}. The projected widths at isocenter of each of the central 34 leaf pairs and 2 peripheral leaf pairs are 10 and 5 mm, respectively. The ends of the leaves and the x-jaws were optimized to obtain acceptable values of dosimetric and leakage parameters. Monte Carlo N-Particle code was used for generating beam profiles and depth dose curves and estimating the leakage radiation through the MLC. A water phantom of dimension 50 Multiplication-Sign 50 Multiplication-Sign 40 cm{sup 3} with an array of voxels (4 Multiplication-Sign 0.3 Multiplication-Sign 0.6 cm{sup 3}= 0.72 cm{sup 3}) was used for the study of dosimetric and leakage characteristics of the MLC. Output files generated for beam profiles were exported to the PTW radiation field analyzer software through locally developed software for analysis of beam profiles in order to evaluate radiation field width, beam flatness, symmetry, and beam penumbra. Results: The optimized version of the MLC can define radiation fields of up to 35 Multiplication-Sign 35 cm{sup 2} within the prescribed tolerance values of 2 mm. The flatness and symmetry were found to be well within the acceptable tolerance value of 3%. The penumbra for a 10 Multiplication-Sign 10 cm{sup 2} field size is 10.7 mm which is less than the generally acceptable value of 12 mm for a telecobalt machine. The maximum and average radiation leakage through the MLC were found to be 0.74% and 0.41% which are well below the International Electrotechnical Commission recommended tolerance values of 2% and 0.75%, respectively. The maximum leakage through the leaf ends in closed condition was observed to be 8.6% which is less than the values reported for other MLCs designed for medical linear accelerators. Conclusions: It is concluded that dosimetric parameters and the leakage radiation of the optimized secondary MLC design are well below their recommended tolerance values. The optimized design of the proposed MLC can be integrated into a telecobalt machine by replacing the existing adjustable secondary collimator for conformal radiotherapy treatment of cancer patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-313: Dosimetric Deviation of Misaligned Beams for a 6 MV Photon Linear Accelerator Using Monte Carlo Simulations

Purpose: To quantify the dosimetric variations of misaligned beams for a linear accelerator by using Monte Carlo (MC) simulations. Method and Materials: Misaligned beams of a Varian 21EX Clinac were simulated to estimate the dosimetric effects. All the linac head components for a 6 MV photon beam were implemented in BEAMnrc/EGSnrc system. For incident electron beam parameters, 6 MeV with 0.1 cm full-width-half-max Gaussian beam was used. A phase space file was obtained below the jaw per each misalignment condition of the incident electron beam: (1) The incident electron beams were tilted by 0.5, 1.0 and 1.5 degrees on the x-axis from the central axis. (2) The center of the incident electron beam was off-axially moved toward +x-axis by 0.1, 0.2, and 0.3 cm away from the central axis. Lateral profiles for each misaligned beam condition were acquired at dmax = 1.5 cm and 10 cm depth in a rectangular water phantom. Beam flatness and symmetry were calculated by using the lateral profile data. Results: The lateral profiles were found to be skewed opposite to the angle of the incident beam for the tilted beams. For the displaced beams, similar skewed lateral profiles were obtained with small shifts of penumbra on the +x-axis. The variations of beam flatness were 3.89–11.18% and 4.12–42.57% for the tilted beam and the translated beam, respectively. The beam symmetry was separately found to be 2.95 −9.93% and 2.55–38.06% separately. It was found that the percent increase of the flatness and the symmetry values are approximated 2 to 3% per 0.5 degree tilt or per 1 mm displacement. Conclusion: This study quantified the dosimetric effects of misaligned beams using MC simulations. The results would be useful to understand the magnitude of the dosimetric deviations for the misaligned beams.

60 APPLIED LIFE SCIENCES↗

Tunable magnetic helicity in Mn{sub 1−x}Fe{sub x}Ge: A Monte Carlo simulation

Motivated by recent experiments on B20 compound Mn{sub 1−x}Fe{sub x}Ge, we explore the variations of spin structures and magnetic helicity γ{sub m} in Mn{sub 1−x}Fe{sub x}Ge as a function of concentration x, using Monte Carlo simulation. We propose a simple spin model including hybrid Dzyaloshinskii-Moriya (DM) interactions with different signs in FeGe and MnGe. The results reveal a series of spin structures with helicity γ{sub m} varying continuously from negative values to positive values upon decreasing x (0.0 ≤ x ≤ 1.0). The simulated x-dependence of the spin structures is consistent with experimental observations, suggesting the validity of the present hybrid model. This study sheds light on control of magnetic helicity in helimagnets, by mixing crystals with different DM interactions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Designing Monte Carlo Simulation and an Optimal Machine Learning to Optimize and Model Space Missions

This paper investigates applying artificial intelligence (AI) algorithms to attitude control system of satellites to optimally tune the controller using high performance computing. This methodology is applied to the Virtual Telescope for X-ray Observation mission, which is a precise formation of two separate spacecraft observing multiple objects in the space in the X-ray domain. The mission is divided into phases based on the instrumentation and the mission goal. To reach an stable precise formation robust to stochastic slew and slew rate (i.e., Euler angles and angular velocities) in a minimal constrained time T , consumed energy of the attitude control system, denoted as E, and root-mean-square state error of attitude control system, denoted as e, are minimized. Monte-Carlo simulation is used for the sensitivity analysis of optimization and designing a controller. Deep neural networks (DNN), Gaussian processes (GP), and support vector regression (SVR) learn this optimization as a surrogate model, while their hyperparameters are optimized in a novel approach. THETA supercomputer at Argonne Leadership Computing Facility (ALCF) is used for optimizing the hyperparameters of DNN. The surrogate model meets the requirements of the mission, and it shows a better performance over the optimization and Monte-Carlo. The optimal DNN can satisfy the mission requirements e and T while reducing E for 90% compared to the other given methods.

42 ENGINEERING↗

A High-Resolution Spatially Explicit Monte-Carlo Simulation Approach to Commercial and Residential Electricity and Water Demand Modeling

As urban areas continue to grow and evolve in a world of increasing environmental awareness, the need for high resolution spatially explicit estimates for energy and water demand has become increasingly important. Though current modeling efforts mark significant progress in the effort to better understand the spatial distribution of energy and water consumption, many are provided at a course spatial resolution or rely on techniques which depend on detailed region-specific data sources that are not publicly available for many parts of the U.S. Furthermore, many existing methods do not account for errors in input data sources and may therefore not accurately reflect inherent uncertainties in model outputs. We propose an alternative and more flexible Monte-Carlo simulation approach to high-resolution residential and commercial electricity and water consumption modeling that relies primarily on publicly available data sources. The method’s flexible data requirement and statistical framework ensure that the model is both applicable to a wide range of regions and reflective of uncertainties in model results.

Energy Modeling↗

A non-additive repulsive contribution in an equation of state: The development for homonuclear square well chains equation of state validated against Monte Carlo simulation

This work consists of the adaptation of a non-additive hard sphere theory inspired by Malakhov and Volkov [Polym. Sci., Ser. A 49(6), 745–756 (2007)] to a square-well chain. Using the thermodynamic perturbation theory, an additional term is proposed that describes the effect of perturbing the chain of square well spheres by a non-additive parameter. In order to validate this development, NPT Monte Carlo simulations of thermodynamic and structural properties of the non-additive square well for a pure chain and a binary mixture of chains are performed. Good agreements are observed between the compressibility factors originating from the theory and those from molecular simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inverse Comptonization in a Two Component Advective Flow: Results of a Monte Carlo simulation

We compute the resultant spectrum due to multiple scattering of soft photons emitted from a Keplerian disk by thermal electrons inside a torus axisymmetrically placed around a black hole. In a two component advective flow model, the post-shock region is similar to a thick accretion disk and the pre-shock sub-keplerian flow is highly optically thin. As a preliminary run of the Monte Carlo simulation of the system, we assume the CENBOL to be a small (2-14r{sub g}) thick accretion disk without a cusp to allow bulk motion of the flow. Bulk Motion Comptonization (BMC) has also been added. We show that the spectral behaviour is very similar to what is predicted in Chakrabarti and Titarchuk (1995)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluate the impact of sensor accuracy on model performance in data-driven building fault detection and diagnostics using Monte Carlo simulation

The performance of data-driven fault detection and diagnostics (FDD) is heavily dependent on sensors. However, sensor inaccuracy and sensor faults are pervasive in building operation: inaccurate and missing sensor readings deteriorate FDD performance; sensor inaccuracy will also affect the selection of sensor for data-driven FDD in the model training process, which is another key factor of data-driven FDD performance. Sensor accuracy and sensor selection individually are well-studied research topics in this field, but the impact of sensor accuracy on sensor selection and its further impact on FDD performance has not been evaluated and quantified. In this paper, we developed a novel analysis methodology that comprehensively evaluates sensor fault on sensor selection and FDD accuracy. Monte Carlo simulation is applied to deal with multiple stochastic sensor inaccuracy and provide probabilistic analysis results of the impact of sensor inaccuracy on sensor selection and FDD accuracy. This methodology focuses on the net impact of fault states across a full sensor set. The developed methodology can be used for the early-stage sensor design and operation-stage sensor maintenance. Furthermore, a case study is conducted to demonstrate the analysis methodology using a commercial building model crated to Flexible Research Platform located at Oak Ridge National Laboratory, USA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monte Carlo Simulation of Electron Interactions in an MeV-STEM for Thick Frozen Biological Sample Imaging

A variety of volume electron microscopy techniques have been developed to visualize thick biological samples. However, the resolution is limited by the sliced section thickness (>30–60 nm). To preserve biological samples in a hydrated state, cryo-focused ion beam scanning electron microscopy has been developed, providing nm resolutions. However, this method is time-consuming, requiring 15–20 h to image a 10 μm thick sample with an 8 nm slice thickness. There is a pressing need for a method that allows the rapid and efficient study of thick biological samples while maintaining nanoscale resolution. The remarkable ability of mega-electron-volt (MeV) electrons to penetrate thick biological samples, even exceeding 10 μm in thickness, while maintaining nanoscale resolution, positions MeV-STEM as a suitable microscopy tool for such applications. Our research delves into understanding the interactions between MeV electrons and frozen biological specimens through Monte Carlo simulations. Single elastic scattering, plural elastic scattering, single inelastic scattering, and plural inelastic scattering events have been simulated. The electron trajectories, the beam profile, and the intensity change of electrons in each category have been investigated. Additionally, the effects of the detector collection angle and the focal position of the electron beam were investigated. As electrons penetrated deeper into the specimen, single and plural elastic scattered electrons diminished, and plural inelastic scattered electrons became dominant, and the beam profile became wider. Even after 10 μm of the specimen, 42% of the MeV electrons were collected within 10 mrad. This confirms that MeV-STEM can be employed to study thick biological samples.

electron specimen interaction↗

Effect of monomer sequences on conformations of copolymers grafted on spherical nanoparticles: A Monte Carlo simulation study

Functionalizing nanoparticles with organic ligands, such as oligomers, polymers, DNA, and proteins, is an attractive way to manipulate the interfacial interactions between the nanoparticles and the medium the particles are placed in, and thus control the nanoparticle assembly. In this paper we have conducted a Monte Carlo simulation study on copolymer grafted spherical nanoparticles to show the tremendous potential of using monomer sequence on the copolymers to tune the grafted chain conformation, and thus the effective interactions between copolymer grafted nanoparticles. We have studied AB copolymers with alternating, multiblock, or diblock sequences, where either A monomers or B monomers have monomer-monomer attractive interactions. Our focus has been to show the nontrivial effect of monomer sequence on the conformations of the grafted copolymers at various particle diameters, grafting densities, copolymer chain lengths, and monomer-monomer interactions in an implicit small molecule solvent. We observe that the monomer sequence, particle diameter, and grafting density dictate whether (a) the grafted chains aggregate to bring attractive monomers from multiple grafted chains together (interchain and intrachain monomer aggregation) if the enthalpy gained by doing so offsets the entropic loss caused by stretching of chains, or (b) each grafted chain folds onto itself to bring its attractive monomers together (only intrachain monomer aggregation) if the entropic loss from interchain aggregation cannot be overcome by the enthalpic gain. For six copolymers of chain length N=24 grafted on a spherical particle of diameter D=4, interchain and intrachain monomer aggregation occurs, and the radius of gyration varies nonmonotonically with increasing blockiness of the monomer sequence. At larger particle diameters the grafted chains transition to purely intrachain monomer aggregation. The radius of gyration varies monotonically with monomer sequence for intrachain monomer aggregation because as the sequence becomes blockier (like monomers are grouped together), the copolymer chain has to fold less compactly to maximize the enthalpically favorable contacts while maintaining high conformational entropy. The radius of gyration of alternating and diblock copolymers scales with chain length N through a power law <R{sub g}{sup 2}>{sup 1/2}={alpha}N{sup {nu}} with the prefactor {alpha} and scaling exponent {nu}, varying with monomer sequence and monomer-monomer attraction strength.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying the effect of anode surface roughness on diagnostic x-ray spectra using Monte Carlo simulation

Purpose: The accurate prediction of x-ray spectra under typical conditions encountered in clinical x-ray examination procedures and the assessment of factors influencing them has been a long-standing goal of the diagnostic radiology and medical physics communities. In this work, the influence of anode surface roughness on diagnostic x-ray spectra is evaluated using MCNP4C-based Monte Carlo simulations. Methods: An image-based modeling method was used to create realistic models from surface-cracked anodes. An in-house computer program was written to model the geometric pattern of cracks and irregularities from digital images of focal track surface in order to define the modeled anodes into MCNP input file. To consider average roughness and mean crack depth into the models, the surface of anodes was characterized by scanning electron microscopy and surface profilometry. It was found that the average roughness (R{sub a}) in the most aged tube studied is about 50 {mu}m. The correctness of MCNP4C in simulating diagnostic x-ray spectra was thoroughly verified by calling its Gaussian energy broadening card and comparing the simulated spectra with experimentally measured ones. The assessment of anode roughness involved the comparison of simulated spectra in deteriorated anodes with those simulated in perfectly plain anodes considered as reference. From these comparisons, the variations in output intensity, half value layer (HVL), heel effect, and patient dose were studied. Results: An intensity loss of 4.5% and 16.8% was predicted for anodes aged by 5 and 50 {mu}m deep cracks (50 kVp, 6 deg. target angle, and 2.5 mm Al total filtration). The variations in HVL were not significant as the spectra were not hardened by more than 2.5%; however, the trend for this variation was to increase with roughness. By deploying several point detector tallies along the anode-cathode direction and averaging exposure over them, it was found that for a 6 deg. anode, roughened by 50 {mu}m deep cracks, the reduction in exposure is 14.9% and 13.1% for 70 and 120 kVp tube voltages, respectively. For the evaluation of patient dose, entrance skin radiation dose was calculated for typical chest x-ray examinations. It was shown that as anode roughness increases, patient entrance skin dose decreases averagely by a factor of 15%. Conclusions: It was concluded that the anode surface roughness can have a non-negligible effect on output spectra in aged x-ray imaging tubes and its impact should be carefully considered in diagnostic x-ray imaging modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural and thermal investigations of an amorphous GaSe{sub 9} alloy using EXAFS, cumulant expansion, and reverse Monte Carlo simulations

In this article, we investigated structural and thermal properties of an amorphous alloy of the Ga–Se system. The amorphous GaSe{sub 9} alloy was produced by mechanical alloying and it was studied using EXAFS spectroscopy and cumulant expansion method. We also made reverse Monte Carlo simulations using the total structure factor S(K) obtained from x-ray diffraction and the EXAFS χ(k) oscillations on Se and Ga K edges as input data. Several parameters, such as average coordination numbers and interatomic distances, structural and thermal disorders, asymmetry of the partial distribution functions g{sub ij}(r), and Einstein and Debye temperatures, were determined. The g{sub ij}{sup E}(r) functions were reconstructed from the cumulants C{sub 1}, C{sub 2}, and C{sub 3} obtained from the Einstein model, and they were compared to the g{sub ij}{sup RMC}(r) functions obtained from the simulations. The simulations also furnished the partial bond angle distribution functions Θ{sub ijℓ}(cosθ), which describe the angular distribution of bonds between first neighbors, and give information about the kind of structural units present in the alloy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of electron energy distribution of an arc-discharge H{sup -} ion source with Monte Carlo simulation

For optimization and accurate prediction of the amount of H{sup -} ion production in negative ion sources, analysis of electron energy distribution function (EEDF) is necessary. We developed a numerical code which analyzes EEDF in the tandem-type arc-discharge source. It is a three-dimensional Monte Carlo simulation code with the effects of cusp, filter, and extraction magnets. Coulomb collision between electrons is treated with Takizuka's model and several inelastic collisions are treated with null-collision method. We applied this code to the JAEA 10 ampere negative ion source. The numerical result shows that the order of electron density is in good agreement with experimental results. In addition, the obtained EEDF is qualitatively in good agreement with experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗