Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A role for myosin VI in retinal pigment epithelium phagocytosis

Highlights: • Quashing myosin VI activity reduces rates of phagosome trafficking in RPE cells. • Trafficked phagosomes in RPE cells undergo two modes of motion. • The more randomly directed mode of phagosome trafficking is myosin VI dependent. • The more directed mode of phagosome trafficking is myosin VI independent. The retinal pigment epithelium (RPE) is a monolayer of pigmented cells adjacent to the choroid coat, the vascular layer of the eye. Among other functions, these cells are responsible for the phagocytosis of rod and cone cell waste shed from the photoreceptor outer segments. We describe here studies to understand the involvement of the motor protein myosin VI in the trafficking of internalized microspheres by a human retinal pigment epithelium primary cell line (ARPE-19). We perturbed the myosin VI-actin interaction by overexpressing a dominant negative myosin VI construct in these cells. We used single particle tracking to characterize the trajectories of internalized fluorescent microspheres. Analysis of the speed of the microspheres' motions revealed that the magnitude of the average speed over short time scales is reduced in the presence of the dominant negative motor. Analysis of the mean-squared displacement of these trajectories demonstrated that trafficking of phagosomes involves two modes of motion, a rapid, more randomly directed motion that is myosin VI dependent and a slower, more directed motion that is independent of the motor. From these data, we posit that this trafficking process involves an interplay between myosin VI motors, which are involved in motion through the actin periphery of the cell, and microtubule motors.

60 APPLIED LIFE SCIENCES↗

Simulation study of the effects of polymer network dynamics and mesh confinement on the diffusion and structural relaxation of penetrants

The diffusion of small molecular penetrants through polymeric materials represents an important fundamental problem, relevant to the design of materials for applications such as coatings and membranes. Polymer networks hold promise in these applications because dramatic differences in molecular diffusion can result from subtle changes in the network structure. In this paper, we use molecular simulation to understand the role that cross-linked network polymers have in governing the molecular motion of penetrants. By considering the local, activated alpha relaxation time of the penetrant and its long-time diffusive dynamics, we can determine the relative importance of activated glassy dynamics on penetrants at the segmental scale vs entropic mesh confinement on penetrant diffusion. We vary several parameters, such as the cross-linking density, temperature, and penetrant size, to show that cross-links primarily affect molecular diffusion through the modification of the matrix glass transition, with local penetrant hopping at least partially coupled to the segmental relaxation of the polymer network. This coupling is very sensitive to the local activated segmental dynamics of the surrounding matrix, and we also show that penetrant transport is affected by dynamic heterogeneity at low temperatures. To contrast, only at high temperatures and for large penetrants or when the dynamic heterogeneity effect is weak, does the effect of mesh confinement become significant, even though penetrant diffusion more broadly empirically follows similar trends as established models of mesh confinement-based transport.

Chemistry↗

Evaluation of delivered monitor unit accuracy of gated step-and-shoot IMRT using a two-dimensional detector array

Purpose: To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array for user-specific verification purpose. Methods: The authors planned a 6 MV photon, seven-port step-and-shoot lung IMRT delivery. The respiration signals for gated IMRT delivery were obtained from the one-dimensional moving phantom using the real-time position management (RPM) system (Varian Medical Systems, Palo Alto, CA). The beams were delivered using a Clinac iX (Varian Medical Systems, Palo Alto, CA) with the Millennium 120 MLC. The MatriXX (IBA Dosimetry GmbH, Germany) was validated through consistency and reproducibility tests as well as comparison with measurements from a Farmer-type ion chamber. The authors delivered beams with varying dose rates and duty cycles and analyzed the MatriXX data to evaluate MU delivery accuracy. Results: There was quite good agreement between the planned segment MUs and the MUs computed from the MatriXX within {+-}2% error. The beam-on times computed from the MatriXX data were almost identical for all cases, and they matched well with the RPM beam-on and beam-off signals. A slight difference was observed between them, but it was less than 40 ms. The gated IMRT delivery demonstrated an MU delivery accuracy that was equivalent to ungated IMRT, and the delivered MUs with a gating signal agreed with the planned MUs within {+-}0.5 MU regardless of dose rate and duty cycle. Conclusions: The authors can conclude that gated IMRT is able to deliver an accurate dose to a patient during a procedure. The authors believe that the methodology and results can be transferred to other vendors' devices, particularly those that do not provide MLC log data for a verification purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Program manual for ASTOP, an Arbitrary space trajectory optimization program

The ASTOP program (an Arbitrary Space Trajectory Optimization Program) designed to generate optimum low-thrust trajectories in an N-body field while satisfying selected hardware and operational constraints is presented. The trajectory is divided into a number of segments or arcs over which the control is held constant. This constant control over each arc is optimized using a parameter optimization scheme based on gradient techniques. A modified Encke formulation of the equations of motion is employed. The program provides a wide range of constraint, end conditions, and performance index options. The basic approach is conducive to future expansion of features such as the incorporation of new constraints and the addition of new end conditions.

Horsewood, J. L.↗

Spatial Distribution of Ionospheric Plasma and Field Structures in the High-Latitude F Region

Ion density and velocity measurements from the Dynamics Explorer 2 (DE 2) spacecraft are used to obtain the average magnetic local time versus invariant latitude distribution of irregularities in the high-latitude F region ionosphere. To study the small-scale structure and its relationship to background conditions in the ionosphere, we have formed a reduced database using 2-s (approx. = 16 km) segments of the ion density and velocity data. The background gradients associated with each 2-s segment and the spectral characteristics, such as power at 6 Hz (approx. = 1.3 km) and spectral index, are among the reduced parameters used in this study. The relationship between the observed plasma structure and its motion is complex and dependent on the externally applied fields as well as locally generated plasma structure. The evolution of plasma structures also depends critically on the conductivity of the underlying ionosphere. Observations indicate an enhancement of irregularity amplitudes in two spatially isolated regions in both the ion density and the velocity. Convective properties seem to play a more important role in winter hemisphere where smaller-scale structures are maintained outside the source regions. (Delta)V irregularity amplitudes are enhanced in the cusp and the polar cap during northward interplanetary magnetic field regardless of season. The power in (Delta)V is usually higher than that associated with local polarization electric fields, suggesting that the observed structure in (Delta)N/N is strongly influenced by (Delta)V structure applied to large density gradients.

Kivanc, O.↗

MagicPlate-512: A 2D silicon detector array for quality assurance of stereotactic motion adaptive radiotherapy

Purpose: Spatial and temporal resolutions are two of the most important features for quality assurance instrumentation of motion adaptive radiotherapy modalities. The goal of this work is to characterize the performance of the 2D high spatial resolution monolithic silicon diode array named “MagicPlate-512” for quality assurance of stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) combined with a dynamic multileaf collimator (MLC) tracking technique for motion compensation. Methods: MagicPlate-512 is used in combination with the movable platform HexaMotion and a research version of radiofrequency tracking system Calypso driving MLC tracking software. The authors reconstruct 2D dose distributions of small field square beams in three modalities: in static conditions, mimicking the temporal movement pattern of a lung tumor and tracking the moving target while the MLC compensates almost instantaneously for the tumor displacement. Use of Calypso in combination with MagicPlate-512 requires a proper radiofrequency interference shielding. Impact of the shielding on dosimetry has been simulated by GEANT4 and verified experimentally. Temporal and spatial resolutions of the dosimetry system allow also for accurate verification of segments of complex stereotactic radiotherapy plans with identification of the instant and location where a certain dose is delivered. This feature allows for retrospective temporal reconstruction of the delivery process and easy identification of error in the tracking or the multileaf collimator driving systems. A sliding MLC wedge combined with the lung motion pattern has been measured. The ability of the MagicPlate-512 (MP512) in 2D dose mapping in all three modes of operation was benchmarked by EBT3 film. Results: Full width at half maximum and penumbra of the moving and stationary dose profiles measured by EBT3 film and MagicPlate-512 confirm that motion has a significant impact on the dose distribution. Motion, no motion, and motion with MLC tracking profiles agreed within 1 and 0.4 mm, respectively, for all field sizes tested. Use of electromagnetic tracking system generates a fluctuation of the detector baseline up to 10% of the full scale signal requiring a proper shielding strategy. MagicPlate-512 is also able to reconstruct the dose variation pulse-by-pulse in each pixel of the detector. An analysis of the dose transients with motion and motion with tracking shows that the tracking feedback algorithm used for this experiment can compensate effectively only the effect of the slower transient components. The fast changing components of the organ motion can contribute only to discrepancy of the order of 15% in penumbral region while the slower components can change the dose profile up to 75% of the expected dose. Conclusions: MagicPlate-512 is shown to be, potentially, a valid alternative to film or 2D ionizing chambers for quality assurance dosimetry in SRS or SBRT. Its high spatial and temporal resolutions allow for accurate reconstruction of the profile in any conditions with motion and with tracking of the motion. It shows excellent performance to reconstruct the dose deposition in real time or retrospectively as a function of time for detailed analysis of the effect of motion in a specific pixel or area of interest.

60 APPLIED LIFE SCIENCES↗

Two modes of screw dislocation glide in fcc single-phase concentrated alloys

Concentrated solid solution alloys (CSSAs), including medium- and high-entropy alloys, are currently being considered as prospective materials in many applications. The behavior of CSSAs under different conditions, including mechanical loading, differs from that of conventional alloys and has been the subject of intensive study by different techniques. In many cases, their behavior is treated by modifying solid solution hardening models, which, in principle, does not reflect many important features of CSSAs where the distinction between solute and solvent atoms is not clear. In this work, we report the results of an atomic-scale study of ½<110>{111} screw dislocation motion in an fcc equiatomic Ni-Fe alloy. Molecular dynamics simulations demonstrate that the dislocation has two distinctive modes for glide. At lower stress, dislocations move in a very rough manner that cannot be described as continuous glide but rather as jerky motion through a set of obstacles. At high stress, they glide in a manner similar to lattice friction-controlled conditions in single component systems. The stress for the transition between modes depends on the dislocation segment length and temperature. As a result, at 300 K, the flow stress saturates at ~130 MPa for lengths above ~140 |b| (b is the Burgers vector).

36 MATERIALS SCIENCE↗

Potential of discrete Gaussian edge feathering method for improving abutment dosimetry in eMLC-delivered segmented-field electron conformal therapy

Purpose: The purpose of this work was to investigate the potential of discrete Gaussian edge feathering of the higher energy electron fields for improving abutment dosimetry in the planning volume when using an electron multileaf collimator (eMLC) to deliver segmented-field electron conformal therapy (ECT). Methods: A discrete (five-step) Gaussian edge spread function was used to match dose penumbras of differing beam energies (6-20 MeV) at a specified depth in a water phantom. Software was developed to define the leaf eMLC positions of an eMLC that most closely fit each electron field shape. The effect of 1D edge feathering of the higher energy field on dose homogeneity was computed and measured for segmented-field ECT treatment plans for three 2D PTVs in a water phantom, i.e., depth from the water surface to the distal PTV surface varied as a function of the x-axis (parallel to leaf motion) and remained constant along the y-axis (perpendicular to leaf motion). Additionally, the effect of 2D edge feathering was computed and measured for one radially symmetric, 3D PTV in a water phantom, i.e., depth from the water surface to the distal PTV surface varied as a function of both axes. For the 3D PTV, the feathering scheme was evaluated for 0.1-1.0-cm leaf widths. Dose calculations were performed using the pencil beam dose algorithm in the Pinnacle{sup 3} treatment planning system. Dose verification measurements were made using a prototype eMLC (1-cm leaf width). Results: 1D discrete Gaussian edge feathering reduced the standard deviation of dose in the 2D PTVs by 34, 34, and 39%. In the 3D PTV, the broad leaf width (1 cm) of the eMLC hindered the 2D application of the feathering solution to the 3D PTV, and the standard deviation of dose increased by 10%. However, 2D discrete Gaussian edge feathering with simulated eMLC leaf widths of 0.1-0.5 cm reduced the standard deviation of dose in the 3D PTV by 33-28%, respectively. Conclusions: A five-step discrete Gaussian edge spread function applied in 2D improves the abutment dosimetry but requires an eMLC leaf resolution better than 1 cm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of SPECT corrections on 3D-dosimetry for liver transarterial radioembolization using the patient relative calibration methodology

Purpose: Many centers aim to plan liver transarterial radioembolization (TARE) with dosimetry, even without CT-based attenuation correction (AC), or with unoptimized scatter correction (SC) methods. This work investigates the impact of presence vs absence of such corrections, and limited spatial resolution, on 3D dosimetry for TARE. Methods: Three voxelized phantoms were derived from CT images of real patients with different body sizes. Simulations of {sup 99m}Tc-SPECT projections were performed with the SIMIND code, assuming three activity distributions in the liver: uniform, inside a “liver’s segment,” or distributing multiple uptaking nodules (“nonuniform liver”), with a tumoral liver/healthy parenchyma ratio of 5:1. Projection data were reconstructed by a commercial workstation, with OSEM protocol not specifically optimized for dosimetry (spatial resolution of 12.6 mm), with/without SC (optimized, or with parameters predefined by the manufacturer; dual energy window), and with/without AC. Activity in voxels was calculated by a relative calibration, assuming identical microspheres and {sup 99m}Tc-SPECT counts spatial distribution. 3D dose distributions were calculated by convolution with {sup 90}Y voxel S-values, assuming permanent trapping of microspheres. Cumulative dose-volume histograms in lesions and healthy parenchyma from different reconstructions were compared with those obtained from the reference biodistribution (the “gold standard,” GS), assessing differences for D95%, D70%, and D50% (i.e., minimum value of the absorbed dose to a percentage of the irradiated volume). γ tool analysis with tolerance of 3%/13 mm was used to evaluate the agreement between GS and simulated cases. The influence of deep-breathing was studied, blurring the reference biodistributions with a 3D anisotropic gaussian kernel, and performing the simulations once again. Results: Differences of the dosimetric indicators were noticeable in some cases, always negative for lesions and distributed around zero for parenchyma. Application of AC and SC reduced systematically the differences for lesions by 5%–14% for a liver segment, and by 7%–12% for a nonuniform liver. For parenchyma, the data trend was less clear, but the overall range of variability passed from −10%/40% for a liver segment, and −10%/20% for a nonuniform liver, to −13%/6% in both cases. Applying AC, SC with preset parameters gave similar results to optimized SC, as confirmed by γ tool analysis. Moreover, γ analysis confirmed that solely AC and SC are not sufficient to obtain accurate 3D dose distribution. With breathing, the accuracy worsened severely for all dosimetric indicators, above all for lesions: with AC and optimized SC, −38%/−13% in liver’s segment, −61%/−40% in the nonuniform liver. For parenchyma, D50% resulted always less sensitive to breathing and sub-optimal correction methods (difference overall range: −7%/13%). Conclusions: Reconstruction protocol optimization, AC, SC, PVE and respiratory motion corrections should be implemented to obtain the best possible dosimetric accuracy. On the other side, thanks to the relative calibration, D50% inaccuracy for the healthy parenchyma from absence of AC was less than expected, while the optimization of SC was scarcely influent. The relative calibration therefore allows to perform TARE planning, basing on D50% for the healthy parenchyma, even without AC or with suboptimal corrections, rather than rely on nondosimetric methods.

60 APPLIED LIFE SCIENCES↗

Structural elements of collapses in shallow water flows with horizontally nonuniform density

The mechanisms and structural elements of instability whose evolution results in the occurrence of the collapse are studied in the scope of the rotating shallow water model with a horizontally nonuniform density. The diagram stability based on the integral collapse criterion is suggested to explain system behavior in the space of constants of motion. Analysis of the instability shows that two collapse scenarios are possible. One scenario implies anisotropic collapse during which the contact area of a collapsing drop-like fragment with the bottom contracts into a rotating segment. The other implies isotropic contraction of the area into a point.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Short-period and long-period perturbations of a spherical satellite due to direct solar radiation

On the basis of expressions derived by Kozai (1961) and those developed in this paper, a detailed semianalytic algorithm is presented for calculating radiation-pressure perturbations in the Keplerian elements. Through some simple modifications, the algorithm is also made to hold when e = 0, i = 0, or both. The perturbations are obtained by summing over the sunlit segment of the satellite's orbit during each revolution or part thereof. The end points of this segment are evaluated numerically once per revolution. The effect of the inherent uncertainties in the boundaries of the earth's shadow is discussed. The algorithm is tested by means of numerical integration of the equations of motion and through comparisons with observations of the balloon satellite 1963 30D during a 200-day interval.

Aksnes, K.↗

Accelerated vortex dynamics across the magnetic 3D-to-2D crossover in disordered superconductors

Disorder can have remarkably disparate consequences in superconductors, driving superconductor–insulator transitions in ultrathin films by localizing electron pairs and boosting the supercurrent carrying capacity of thick films by localizing vortices (magnetic flux lines). Though the electronic 3D-to-2D crossover at material thicknesses d ~ ξ (coherence length) is well studied, a similarly consequential magnetic crossover at d ~ L c (pinning length) that should drastically alter material properties remains largely underexamined. According to collective pinning theory, vortex segments of length L c bend to adjust to energy wells provided by point defects. Consequently, if d truncates L c , a change from elastic to rigid vortex dynamics should increase the rate of thermally activated vortex motion S. Here, we characterize the dependence of S on sample thickness in Nb and cuprate films. The results for Nb are consistent with collective pinning theory, whereas creep in the cuprate is strongly influenced by sparse large precipitates. In conclusion, we leverage the sensitivity of S to d to determine the generally unknown scale L c , establishing a new route for extracting pinning lengths in heterogeneously disordered materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

δ-SUNSPOT FORMATION IN SIMULATION OF ACTIVE-REGION-SCALE FLUX EMERGENCE

δ-sunspots, with highly complex magnetic structures, are very productive in energetic eruptive events, such as X-class flares and homologous eruptions. We here study the formation of such complex magnetic structures by numerical simulations of magnetic flux emergence from the convection zone into the corona in an active-region-scale domain. In our simulation, two pairs of bipolar sunspots form on the surface, originating from two buoyant segments of a single subsurface twisted flux rope, following the approach of Toriumi et al. Expansion and rotation of the emerging fields in the two bipoles drive the two opposite polarities into each other with apparent rotating motion, producing a compact δ-sunspot with a sharp polarity inversion line. The formation of the δ-sunspot in such a realistic-scale domain produces emerging patterns similar to those formed in observations, e.g., the inverted polarity against Hale's law, the curvilinear motion of the spot, and strong transverse field with highly sheared magnetic and velocity fields at the polarity inversion line (PIL). Strong current builds up at the PIL, giving rise to reconnection, which produces a complex coronal magnetic connectivity with non-potential fields in the δ-spot overlaid by more relaxed fields connecting the two polarities at the two ends.

79 ASTRONOMY AND ASTROPHYSICS↗

Perceived visual speed constrained by image segmentation

Little is known about how or where the visual system parses the visual scene into objects or surfaces. However, it is generally assumed that the segmentation and grouping of pieces of the image into discrete entities is due to 'later' processing stages, after the 'early' processing of the visual image by local mechanisms selective for attributes such as colour, orientation, depth, and motion. Speed perception is also thought to be mediated by early mechanisms tuned for speed. Here we show that manipulating the way in which an image is parsed changes the way in which local speed information is processed. Manipulations that cause multiple stimuli to appear as parts of a single patch degrade speed discrimination, whereas manipulations that perceptually divide a single large stimulus into parts improve discrimination. These results indicate that processes as early as speed perception may be constrained by the parsing of the visual image into discrete entities.

NASA Discipline Neuroscience↗

Microgravity vestibular investigations: perception of self-orientation and self-motion

Four astronauts experienced passive whole-body rotation in a number of test sessions during a 7-day orbital mission. Pitch (Y-axis) and roll (X-axis) rotation required subject orientations on the rotator in which the otolith system was at radius of 0.5 m. Thus subjects experienced a constant -0.22 Gz stimulus to the otoliths during the 60 s constant-velocity segments of "pitch" and "roll" ramp profiles. The Gz stimulus, a radius-dependent vector ranging from -0.22 Gz at the otoliths to +0.36 Gz at the feet, generated sensory information that was not interpreted as inversion in any of the 16 tests carried out in flight (12 in pitch and 4 in roll orientation). None of the subjects was rotated with head off-center during the first 33 h of the mission. In the state of orbital adaptation of these subjects, a -0.22 Gz otolith stimulus did not provide a vertical reference in the presence of a gradient of +Gz stimuli to the trunk and legs.

NASA Experiment Number 284058↗

Clinical Utility of 4D FDG-PET/CT Scans in Radiation Treatment Planning

Purpose: The potential role of four-dimensional (4D) positron emission tomography (PET)/computed tomography (CT) in radiation treatment planning, relative to standard three-dimensional (3D) PET/CT, was examined. Methods and Materials: Ten patients with non-small-cell lung cancer had sequential 3D and 4D [{sup 18}F]fluorodeoxyglucose PET/CT scans in the treatment position prior to radiation therapy. The gross tumor volume and involved lymph nodes were contoured on the PET scan by use of three different techniques: manual contouring by an experienced radiation oncologist using a predetermined protocol; a technique with a constant threshold of standardized uptake value (SUV) greater than 2.5; and an automatic segmentation technique. For each technique, the tumor volume was defined on the 3D scan (VOL3D) and on the 4D scan (VOL4D) by combining the volume defined on each of the five breathing phases individually. The range of tumor motion and the location of each lesion were also recorded, and their influence on the differences observed between VOL3D and VOL4D was investigated. Results: We identified and analyzed 22 distinct lesions, including 9 primary tumors and 13 mediastinal lymph nodes. Mean VOL4D was larger than mean VOL3D with all three techniques, and the difference was statistically significant (p < 0.01). The range of tumor motion and the location of the tumor affected the magnitude of the difference. For one case, all three tumor definition techniques identified volume of moderate uptake of approximately 1 mL in the hilar region on the 4D scan (SUV maximum, 3.3) but not on the 3D scan (SUV maximum, 2.3). Conclusions: In comparison to 3D PET, 4D PET may better define the full physiologic extent of moving tumors and improve radiation treatment planning for lung tumors. In addition, reduction of blurring from free-breathing images may reveal additional information regarding regional disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A refined finite element for vibration analysis of twisted blades based on beam theory

A finite element method of discretizing beam segments of pretwisted rotating blades is presented. Employing the matrix displacement method, stiffness and mass properties are developed from basic mechanics of a pretwisted beam theory. By introducing the proper displacement functions, the effect of rotor blade rotational motion on the stiffness matrix is obtained systematically from the kinetic energy expression. Comparing with other beam elements the derivation of this element is more fundamental. This allows one to apply the same approach to more complicated problems including nonlinear effects or complex dynamic motions. Illustrative examples are given comparing numerical results with available data and other numerical solutions from rotating and nonrotating force fields. These examples show that accurate prediction of vibration frequencies for pretwisted blades can be obtained by employing a quite modest number of degrees of freedom.

Sisto, F.↗

A Transient Response Method for Linear Coupled Substructures

A method is presented for determining the transient response of a discrete coordinate model of a linear structural system composed of substructures. The method is applicable to systems consisting of any number of substructures, both determinate and indeterminate interface boundaries, and any topological arrangement of the substructures. The method is simple to implement from a computational point of view because the equations of motion of each of the substructures are solved independently, and the interface boundary compatibility conditions are enforced at each integration time step by a matrix multiplication. The method is demonstrated for a structural system consisting of two beam segments and acted upon by a time dependent force. The numerical results from the demonstration problem validates the accuracy of the method. The application of this method to structural systems with changing interface boundary conditions between substructures is discussed.

Admire, J. R.↗