Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

ARIADNE – a program estimating covariances in detail for neutron experiments

The python program ARIADNE is a tool developed for evaluators to estimate detailed uncertainties and covariances for experimental data in a consistent and efficient manner. Currently, it is designed to aid in the uncertainty quantification of prompt fission neutron spectra, and was employed to estimate experimental covariances for CIELO and ENDF/B-VIII.0 evaluations. It provides a streamlined way to estimate detailed covariances by (1) implementing uncertainty quantification algorithms specific to the observables, (2) defining input quantities for typically encountered uncertainty sources and correlation shapes, and (3) automatically generating plots of data, uncertainties and correlations, GND formatted XML and plain text output files. Covariances of the same and between different datasets can be estimated, and tools are provided to assemble a database of experimental data and covariances for an evaluation based on ARIADNE outputs. The underlying IPython notebook files can be easily stored, including all assumptions on uncertainties, leading to more reproducible inputs for nuclear data evaluations. Here, the key inputs and outputs are shown along with a representative example for the current version of ARIADNE to illustrate its usability and to open a discussion on how it could address further needs of the nuclear data evaluation community.

97 MATHEMATICS AND COMPUTING↗

Neutron Emission Profile And Neutron Spectrum Measurements At JET: Status And Plans

In large tokamak devices, such as JET, TFTR, JT-60U and ITER, a neutron emission profile monitor is considered as one of the principal diagnostic tools, firstly in providing information to characterize the fusion source in terms of its location, shape, intensity and secondly in developing an understanding of fast ion physics in tokamak plasmas. The JET neutron profile monitor is one of the most advanced such instruments currently operating. It enables 2-D imaging of the non-circular plasma neutron source through a tomographic deconvolution of line-integrated measurements. Historically it was usually assumed that the fusion neutron source is a function of the magnetic flux surfaces (MFS), but recent JET results have clearly demonstrated the influence of non-uniform fast particle populations on the neutron emission profile.Neutron energy spectroscopy also carries valuable information about fast ion behaviour and the fusion and nuclear reactions taking place in the plasma. Spectrum measurements of neutrons will be particularly important for the up-coming JET experiments with a Be wall. The neutron spectroscopy capabilities at JET were recently enhanced by several instruments: a new time-of-flight spectrometer optimized for high count rates (TOFOR), compact neutron spectrometers based on organic scintillator (NE213) and an upgrade of the Magnetic Proton Recoil system (MPRu). In recent JET campaigns, a prototype digital pulse shape discriminator (DPSD) has been successfully tested on one central chord of the JET neutron profile monitor and spectral information has also been obtained. Neutron spectrometry results obtained during the last JET experimental campaigns illustrate the measurement capabilities and indicate their potential use on ITER. Several projects are in progress to further develop such diagnostic capabilities and these are briefly summarized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of DT and DD components in neutron spectrum with a double-crystal time-of-flight spectrometer

To investigate the deuteron and triton density ratio in core plasmas, a new methodology with measurement of tritium (DT) and deuterium (DD) neutron count rate ratio using a double-crystal time-of-flight (TOF) spectrometer is proposed. Multi-discriminator electronic circuits for the first and second detectors are used in addition to the TOF technique. The optimum arrangement of the detectors and discrimination window were examined considering the relations between the geometrical arrangement and deposited energy using a Monte Carlo Code, PHITS (Particle and Heavy Ion Transport Code System). An experiment to verify the calculations was performed using DD neutrons from an accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron-Rich Hypernuclei Are Coming. What They Tell Us ?

We continue the discussion of our suggestion presented at FINUSTAR 1: to explore the potential of hypernuclear spectroscopy for investigation the structure of light nuclei beyond neutron dripline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First measurements of the absolute neutron spectrum using the magnetic recoil spectrometer at OMEGA (invited)

A neutron spectrometer, called a magnetic recoil spectrometer (MRS), has been built and implemented at the OMEGA laser facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] for absolute measurements of the neutron spectrum in the range of 6-30 MeV, from which fuel areal density ({rho}R), ion temperature (T{sub i}), and yield (Y{sub n}) can be determined. The results from the first MRS measurements of the absolute neutron spectrum are presented. In addition, measuring {rho}R at the National Ignition Facility (NIF) [G. H. Miller et al., Nucl. Fusion 44, S228 (2004)] will be essential for assessing implosion performance during all stages of development from surrogate implosions to cryogenic fizzles to ignited implosions. To accomplish this, we are also developing an MRS for the NIF. As much of the research and development and instrument optimization of the MRS at OMEGA are directly applicable to the MRS at the NIF, a description of the design and characterization of the MRS on the NIF is discussed as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of Neutron Shielding for the PICASSO Experiment

The PICASSO experiment searches WIMPs via their spin-dependent interactions with nuclei. At their operating temperatures, PICASSO threshold detectors are not sensitive to {gamma}-rays, while it is necessary to suppress neutron and {alpha}-ray backgrounds. The different types of neutron shielding (water, polyethylene, borated water and polyethylene doped with different compounds of boron and lithium) were studied via the Monte Carlo method using MCNPX code. Efficiencies of these different types of neutron shielding were compared from the point of view of neutron suppression as well as number of newly born y-rays. The neutrons and {gamma}-rays were followed up to the PICASSO detector active material. The most suitable neutron shielding for the PICASSO experiment was determined following these simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the absolute deuterium-tritium neutron yield using the magnetic recoil spectrometer at OMEGA and the NIF

A magnetic recoil spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IBIS: An inverse geometry Brillouin inelastic neutron spectrometer for the SNS

The high power target station at the Spallation Neutron Source (SNS) currently has about 20 completed neutron scattering instruments. With a broad coverage of the momentum transfer (Q)-energy (E) space, these instruments serve an extensive user community. In an effort to further expand the scientific capabilities of the SNS instrument suites, we propose a low background, inverse geometry Brillouin inelastic spectrometer for the SNS which will expand the Q-E coverage of the current instrument suite and facilitate the study of inelastic and quasi-elastic scatterings at low Q values. The possible location for the proposed instrument is either beamline 8 which views the decoupled water moderator, or beamline 14A, which views a cold, coupled super critical hydrogen moderator. The instrument parameters, optimizations, and performances at these two beamline locations are discussed.

43 PARTICLE ACCELERATORS↗

The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF

The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, iontemperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A compact neutron spectrometer for characterizing inertial confinement fusion implosions at OMEGA and the NIF

A compact spectrometer for measurements of the primary deuterium-tritium neutron spectrum has been designed and implemented on the OMEGA laser facility [T. Boehly et al., Opt. Commun. 133, 495 (1997)]. This instrument uses the recoil spectrometry technique, where neutrons produced in an implosion elastically scatter protons in a plastic foil, which are subsequently detected by a proton spectrometer. This diagnostic is currently capable of measuring the yield to ∼±10% accuracy, and mean neutron energy to ∼±50 keV precision. As these compact spectrometers can be readily placed at several locations around an implosion, effects of residual fuel bulk flows during burn can be measured. Future improvements to reduce the neutron energy uncertainty to ±15−20 keV are discussed, which will enable measurements of fuel velocities to an accuracy of ∼±25−40 km/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data acquisition system with pulse height capability for the TOFED time-of-flight neutron spectrometer

A new time-of-flight neutron spectrometer TOFED has been constructed for installation at Experimental Advanced Superconducting Tokamak. A data acquisition system combining measurements of flight time and energy from the interaction of neutrons with the TOFED scintillators has been developed. The data acquisition system can provide a digitizing resolution better than 1.5% (to be compared with the >10% resolution of the recoil particle energy in the plastic scintillators) and a time resolution <1 ns. At the same time, it is compatible with high count rate event recording, which is an essential feature to investigate phenomena occurring on time scales faster than the slowing down time (≈100 ms) of the beam ions in the plasma. Implications of these results on the TOFED capability to resolve fast ion signatures in the neutron spectrum from EAST plasmas are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of fuel and ablator ρR in Symmetry-Capsule implosions with the Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility

The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility (NIF) measures the neutron spectrum in the energy range of 4–20 MeV. This paper describes MRS measurements of DT-fuel and CH-ablator ρR in DT gas-filled symmetry-capsule implosions at the NIF. DT-fuel ρR's of 80–140 mg/cm{sup 2} and CH-ablator ρR's of 400–680 mg/cm{sup 2} are inferred from MRS data. The measurements were facilitated by an improved correction of neutron-induced background in the low-energy part of the MRS spectrum. This work demonstrates the accurate utilization of the complete MRS-measured neutron spectrum for diagnosing NIF DT implosions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light output function and assembly of the time-of-flight enhanced diagnostics neutron spectrometer plastic scintillators for background reduction by double kinematic selection at EAST

The 2.5 MeV neutron spectrometer TOFED (Time-Of-Flight Enhanced Diagnostics) has been constructed to perform advanced neutron emission spectroscopy diagnosis of deuterium plasmas on EAST. The instrument has a double-ring structure which, in combination with pulse shape digitization, allows for a dual kinematic selection in the time-of-flight/recoil proton energy (tof/E{sub p}) space, thus improving the spectrometer capability to resolve fast ion signatures in the neutron spectrum, in principle up to a factor ≈100. The identification and separation of features from the energetic ions in the neutron spectrum depends on the detailed knowledge of the instrument response function, both in terms of the light output function of the scintillators and the effect of undesired multiple neutron scatterings in the instrument. This work presents the determination of the light output function of the TOFED plastic scintillator detectors and their geometrical assembly. Results from dedicated experiments with γ-ray sources and quasi-monoenergetic neutron beams are presented. Implications on the instrument capability to perform background suppression based on double kinematic selection are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of time of flight detectors using laser-driven neutron source

Calibration of three scintillators (EJ232Q, BC422Q, and EJ410) in a time-of-flight arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub-MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors is shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A spherical shell target scheme for laser-driven neutron sources

A scheme for neutron production is investigated in which an ultra-intense laser is irradiated into a two-layer (deuterium and aurum) spherical shell target through the cone shaped entrance hole. It is found that the energy conversion efficiency from laser to target can reach as high as 71%, and deuterium ions are heated to a maximum energy of several MeV from the inner layer surface. These ions are accelerated towards the center of the cavity and accumulated finally with a high density up to tens of critical density in several picoseconds. Two different mechanisms account for the efficient yield of the neutrons in the cavity: (1) At the early stage, the neutrons are generated by the high energy deuterium ions based on the “beam-target” approach. (2) At the later stage, the neutrons are generated by the thermonuclear fusion when the most of the deuterium ions reach equilibrium in the cavity. It is also found that a large number of deuterium ions accelerated inward can pass through the target center and the outer Au layer and finally stopped in the CD{sub 2} layer. This also causes efficient yield of neutrons inside the CD{sub 2} layer due to “beam-target” approach. A postprocessor has been designed to evaluate the neutron yield and the neutron spectrum is obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of the coincidence counting technique to DD neutron spectrometry data at the NIF, OMEGA, and Z

A compact neutron spectrometer, based on a CH foil for the production of recoil protons and CR-39 detection, is being developed for the measurements of the DD-neutron spectrum at the NIF, OMEGA, and Z facilities. As a CR-39 detector will be used in the spectrometer, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). To reject the background to the required level for measurements of the down-scattered and primary DD-neutron components in the spectrum, the Coincidence Counting Technique (CCT) must be applied to the data. Using a piece of CR-39 exposed to 2.5-MeV protons at the MIT HEDP accelerator facility and DD-neutrons at Z, a significant improvement of a DD-neutron signal-to-background level has been demonstrated for the first time using the CCT. These results are in excellent agreement with previous work applied to DT neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal and background considerations for the MRSt on the National Ignition Facility (NIF)

A Magnetic Recoil Spectrometer (MRSt) has been conceptually designed for time-resolved measurements of the neutron spectrum at the National Ignition Facility. Using the MRSt, the goals are to measure the time-evolution of the spectrum with a time resolution of ∼20-ps and absolute accuracy better than 5%. To meet these goals, a detailed understanding and optimization of the signal and background characteristics are required. Through ion-optics, MCNP simulations, and detector-response calculations, it is demonstrated that the goals and a signal-to background >5–10 for the down-scattered neutron measurement are met if the background, consisting of ambient neutrons and gammas, at the MRSt is reduced 50–100 times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The magnetic recoil spectrometer (MRSt) for time-resolved measurements of the neutron spectrum at the National Ignition Facility (NIF)

The next-generation magnetic recoil spectrometer for time-resolved measurements of the neutron spectrum has been conceptually designed for the National Ignition Facility. This spectrometer, called MRSt, represents a paradigm shift in our thinking about neutron spectrometry for inertial confinement fusion applications, as it will provide simultaneously information about the burn history and time evolution of areal density (ρR), apparent ion temperature (T{sub i}), yield (Y{sub n}), and macroscopic flows during burn. From this type of data, an assessment of the evolution of the fuel assembly, hotspot, and alpha heating can be made. According to simulations, the MRSt will provide accurate data with a time resolution of ∼20 ps and energy resolution of ∼100 keV for total neutron yields above ∼10{sup 16}. At lower yields, the diagnostic will be operated at a higher-efficiency, lower-energy-resolution mode to provide a time resolution of ∼20 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗