Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Analysis of the one-dimensional transient compressible vapor flow in heat pipes

The transient compressible one-dimensional vapor flow dynamics in a heat pipe is modeled. The numerical results are obtained by using the implicit non-iterative Beam-Warming finite difference method. The model is tested for simulated heat pipe vapor flow and actual vapor flow in cylindrical heat pipes. A good comparison of the present transient results for the simulated heat pipe vapor flow with the previous results of a two-dimensional numerical model is achieved and the steady state results are in agreement with the existing experimental data. The transient behavior of the vapor flow under subsonic, sonic, and supersonic speeds as well as high mass flow rates are successfully predicted.

Jang, Jong H.↗

Investigation of micro-gravity effects on heat pipe thermal performance and working fluid behavior, phase B

The purpose of this experiment is to develop an in-depth understanding of the behavior of heat pipes in space. Both fixed conductance heat pipes (FCHPs) with axial grooves and variable conductance heat pipes (VCHPs) with porous wicks will be investigated. This understanding will be applied to the development of improved performance heat pipes subjected to various accelerations in space, including those encountered on a lunar base or Mars mission. More efficient, reliable, and lighter weight spacecraft thermal control systems should result from these investigations.

Gier, K. D.↗

A study of start-up characteristics of a potassium heat pipe from the frozen state

The start up characteristics of a potassium heat pipe were studied both analytically and experimentally. Using the radiation heat transfer mode the heat pipe was tested in a vacuum chamber. The transition temperature calculated for potassium was then compared with the experimental results of the heat pipe with various heat inputs. These results show that the heat pipe was inactive until it reached the transition temperature. In addition, during the start up period, the evaporator experienced dry-out with a heat input smaller than the capillary limit calculated at the steady state. However, when the working fluid at the condensor was completely melted, the evaporation was rewetted without external aid. The start up period was significantly reduced with a large heat input.

Jang, Jong Hoon↗

Transverse flat plate heat pipe experiment

The Transverse Flat Plate Heat Pipe is a thermal control device that serves the dual function of temperature control and mounting base for electronic equipment. In its ultimate application, the heat pipe would be a lightweight structural member that could be configured in a platform or enclosure, and provide temperature control for large space structures, flight experiments, and equipment. The purpose of this experiment is to evaluate the zero g performance of several heat pipe modules. Performance assessment will include: (1) the systems heat transport capability; (2) temperature drop between evaporator and condensor; and (3) the ability to maintain temperature over varying duty cycles and environments. Also, performance degradation, if any, will be monitored over the length of the LDEF mission. The objective of this experiment is to demonstrate that a self-regulated heat pipe thermal control system can maintain hardware temperatures within tolerances of + or - 9 F or less with varying heat inputs, independent of vehicle payload orientation.

Shular, David↗

A study of high-temperature heat pipes with multiple heat sources and sinks. I - Experimental methodology and frozen startup profiles. II - Analysis of continuum transient and steady-state experimental data with numerical predictions

Experimental profiles for heat pipe startup from the frozen state were obtained, using a high-temperature sodium/stainless steel pipe with multiple heat sources and sinks to investigate the startup behavior of the heat pipe for various heat loads and input locations, with both low and high heat rejection rates at the condensor. The experimental results of the performance characteristics for the continuum transient and steady-state operation of the heat pipe were analyzed, and the performance limits for operation with varying heat fluxes and location are determined.

Faghri, A.↗

Design and performance of a Cryogenic Heat Pipe Experiment (CRYOHP)

The Cryogenic Heat Pipe Experiment which is designed to demonstrate the thermal performance of two different axially grooved oxygen heat pipes in microgravity is discussed. The CRYOHP is manifested for flight aboard STS-53. The first heat pipe design is based on an extrapolated 0-g transport capability of about 20 W-m with oxygen in the range of 80-100 K. The second heat pipe design permits 0-g 'dry-out' in the CRYOHP and offers improved ground testability for 1-g correlation.

Beam, Jerry↗

Visualizing the thermal performance of heat pipes with thermochromic liquid crystals

A novel technique has been developed to visualized the thermal performance characteristics of simple low temperature heat pipes and thermosyphons. Copper heat pipes with internal, annular mesh wicks and charged with Refrigerant-12 were externally coated with thermochromic liquid crystal (TLC) paints. The thermally sensitive TLC coating reversibly changes color upon heating and readily permits visual identification of transient and steady state isotherms during low temperature operation. The start-up and operational behaviors of the heat pipe as well as the presence of non-condensible gases can be visually identified through a spectrum of color changes. A brief video demonstration illustrating heat pipe thermal performance characteristics has been developed and illustrates the utility of TLCs for visualizing thermal behavior.

Gunnerson, Fred S.↗

Cryogenic Heat Pipe Experiment (CRYOHP)

The objective of the CRYOHP experiment is to conduct a shuttle experiment that demonstrates the reliable operation of two oxygen heat pipes in microgravity. The experiment will perform the following tasks: (1) demonstrate startup of the pipes from the supercritical state; (2) measure the heat transport capacity of the pipes; (3) measure evaporator and condenser film coefficients; and (4) work shuttle safety issues. The approach for the experiment is as follows: (1) fly two axially grooved oxygen heat pipes attached to mechanical stirling cycle tactical coolers; (2) integrate experiment in hitch-hiker canister; and (3) fly on shuttle and control from ground.

Mcintosh, Roy↗

Heat pipe performance experiment

The objective of the heat pipe performance experiment is to answer questions about how heat pipe performance in space differs from heat pipe performance on the ground. This part of the experiment will attempt to account for the following: (1) gravity domination in ground testing; (2) surface tension domination in a microgravity environment; and (3) the effects of underfill and overfill. The secondary objective of the experiment is to obtain quantitative data for axial groove and porous wick heat pipes in a microgravity environment for comparison with the following: (1) analytical models; (2) ground test data; and (3) existing flight data.

Fleischman, George↗

Heat-pipe transient model for space applications

A two-dimensional model is developed for simulating heat pipes transient performance following changes in the input/rejection power or in the evaporator/condenser temperatures. The model employs the complete form of governing equations and momentum and energy jump conditions at the liquid-vapor interface. Although the model is capable of handling both cylindrical and rectangular geometries, the results reported are for a circular heat pipe with liquid lithium as the working fluid. The model incorporates a variety of other working fluids, such as water, ammonia, potassium, sodium and mercury, and offers combinations of isothermal, isoflux, convective and radiative heating/cooling conditions in the evaporator and condenser regions of the heat pipe. Results presented are for lithium heat pipes with exponential heating of the evaporator and isothermal cooling of the condenser.

Tournier, Jean-Michel↗

A study of circumferentially-heated and block-heated heat pipes. I - Experimental analysis and generalized analytical prediction of capillary limits. II - Three-dimensional numerical modeling as a conjugate problem

The wall and centerline vapor temperatures and heat output are determined experimentally for a low-temperature copper-water heat pipe under uniform circumferential heating and block heating. The time required to reach a vapor temperature of 60 C from an initial ambient temperature of 21 C is determined for both modes of heating. The experimental capillary limit of the heat pipe is compared to the generalized capillary limits for block-heated pipes over a range of vapor temperatures. A three-dimensional numerical model is then developed for determining the temperature, pressure, and velocity distributions in the entire domain of a circumferentially heated and a block-heated pipe. The problem is formulated as a conjugate problem, without the assumption of a uniform vapor temperature. The predictions of the model are found to be in good agreement with the experimental data.

Schmalhofer, Joseph↗

Heat Pipe With Interrupted Slot

Newer version of heat pipe slot interrupted by plug or, if heat pipe is cast, by bridge of heat-pipe material cast integrally across groove. Small barrier assists in priming heat pipe. Vapor and noncondensible gas still accumulates in liquid channel at evaporator before or during startup, but barrier keeps liquid out of small part of slot at bubble. Dry part of slot allows bubble to escape into vapor channel, making room for liquid to move in during startup.

Brown, Richard F.↗

Physics of heat pipe rewetting

This is the final report which summarizes the research accomplishments under the project entitled 'Physics of Heat Pipe Rewetting' under NASA Grant No. NAG 9-525, Basic, during the period of April 1, 1991 to January 31, 1994. The objective of the research project was to investigate both analytically and experimentally the rewetting characteristics of the heated, grooved plate. The grooved plate is to simulate the inner surface of the vapor channel in monogroove heat pipes for space station design. In such designs, the inner surface of the vapor channel is threaded with monogrooves. When the heat pipe is thermally overloaded, dryout of the monogroove surface occurs. Such a dryout surface should be promptly rewetted to prevent the failure of the heat pipe operation in the thermal radiator of the space station.

Chan, S. H.↗

Carbon-Carbon Heat Pipe Testing and Evaluation

This report discusses development and proof-of-concept testing of a new lightweight carbon-carbon (C-C) space radiator heat pipe developed under the NASA Civil Space Technology Initiative (CSTI) High Capacity Power Program. The heat pipe was filled with potassium working fluid and tested for 11 hours including startup from ambient temperature with the working fluid initially in the frozen state to near 700 K condenser temperature. Steady-state heat pipe input power during testing was facility limited to about 300 watts, representing about 50 percent of the design input power. Post test inspection showed the heat pipe to be in excellent condition after eight thermal cycles from ambient to steady-state operating temperature. Potential applications, ranging from small spacecraft heat rejection to aircraft and terrestrial uses, are discussed.

Juhasz, Albert J.↗

Baseline experimental investigation of an electrohydrodynamically assisted heat pipe

The increases in power demand and associated thermal management requirements of future space programs such as potential Lunar/Mars missions will require enhancing the operating efficiencies of thermal management devices. Currently, the use of electrohydrodynamically (EHD) assisted thermal control devices is under consideration as a potential method of increasing thermal management system capacity. The objectives of the currently described investigation included completing build-up of the EHD-Assisted Heat Pipe Test bed, developing test procedures for an experimental evaluation of the unassisted heat pipe, developing an analytical model capable of predicting the performance limits of the unassisted heat pipe, and obtaining experimental data which would define the performance characteristics of the unassisted heat pipe. The information obtained in the currently proposed study will be used in order to provide extensive comparisons with the EHD-assisted performance observations to be obtained during the continuing investigation of EHD-Assisted heat transfer devices. Through comparisons of the baseline test bed data and the EHD assisted test bed data, accurate insight into the performance enhancing characteristics of EHD augmentation may be obtained. This may lead to optimization, development, and implementation of EHD technology for future space programs.

Duncan, A. B.↗

Shield For Flexible Pipe

Cylindrical shield designed to fit around flexible pipe to protect nearby workers from injury and equipment from damage if pipe ruptures. Designed as pressure-relief device. Absorbs impact of debris ejected radially from broken flexible pipe. Also redirects flow of pressurized fluid escaping from broken pipe onto flow path allowing for relief of pressure while minimizing potential for harm.

Ponton, Michael K.↗

Direct Numerical Simulation of Incompressible Pipe Flow Using a B-Spline Spectral Method

A numerical method based on b-spline polynomials was developed to study incompressible flows in cylindrical geometries. A b-spline method has the advantages of possessing spectral accuracy and the flexibility of standard finite element methods. Using this method it was possible to ensure regularity of the solution near the origin, i.e. smoothness and boundedness. Because b-splines have compact support, it is also possible to remove b-splines near the center to alleviate the constraint placed on the time step by an overly fine grid. Using the natural periodicity in the azimuthal direction and approximating the streamwise direction as periodic, so-called time evolving flow, greatly reduced the cost and complexity of the computations. A direct numerical simulation of pipe flow was carried out using the method described above at a Reynolds number of 5600 based on diameter and bulk velocity. General knowledge of pipe flow and the availability of experimental measurements make pipe flow the ideal test case with which to validate the numerical method. Results indicated that high flatness levels of the radial component of velocity in the near wall region are physical; regions of high radial velocity were detected and appear to be related to high speed streaks in the boundary layer. Budgets of Reynolds stress transport equations showed close similarity with those of channel flow. However contrary to channel flow, the log layer of pipe flow is not homogeneous for the present Reynolds number. A topological method based on a classification of the invariants of the velocity gradient tensor was used. Plotting iso-surfaces of the discriminant of the invariants proved to be a good method for identifying vortical eddies in the flow field.

Loulou, Patrick↗

Thermal Insulation Performance of Flexible Piping for Use in HTS Power Cables

High-temperature superconducting (HTS) cables that typically operate at temperatures below 80 K are being developed for power transmission. The practical application of HTS power cables will require the use of flexible piping to contain the cable and the liquid nitrogen coolant. A study of thermal performance of multilayer insulation (MLI) was conducted in geometries representing both rigid and flexible piping. This experimental study performed at the Cryogenics Test Laboratory of NASA Kennedy Space Center provides a framework for the development of cost-effective, efficient thermal insulation systems that will support these long-distance flexible lines containing HTS power cables. The overall thermal performance of the insulation system for a rigid configuration and for a flexible configuration, simulating a flexible HTS power cable, was determined by the steady-state liquid nitrogen boiloff method under the full range of vacuum levels. Two different cylindrically rolled material systems were tested: a standard MLI and a layered composite insulation (LCI). Comparisons of ideal MLI, MLI on rigid piping, and MLI between flexible piping are presented.

Fesmire, James E.↗