At least 415 records · Page 23

High energy density capacitors for vacuum operation with a pulsed plasma load

Results of the effort of designing, fabricating, and testing of a 40 joules/lb (88.2 joules/Kg) high voltage energy storage capacitor suitable for operating a pulsed plasma thruster in a vacuum environment for millions of pulses are presented. Using vacuum brazing and heli-arc welding techniques followed by vacuum and high pressure helium leak tests it was possible to produce a hermetically sealed relatively light weight enclosure for the dielectric system. An energy density of 40 joules/lb was realized with a KF-polyvinylidene fluoride dielectric system. One capacitor was D.C. life tested at 4 KV (107.8 joules/lb) for 2,000 hours before it failed. Another exceeded 2,670 hours without failure at 38.3 joules/lb. Pulse life testing in a vacuum exceeded 300,000 discharges with testing still in progress. The D.C. life test data shows a small decrease in capacitance and an increase in dissipation factor with time. Heat transfer from the load to the capacitor must also be considered besides the self-heat generated by the capacitor.

Guman, W. J.↗

Airborne bathymetric charting using pulsed blue-green lasers

Laboratory and airborne experiments have proven the feasibility and demonstrated the techniques of an airborne pulsed laser system for rapidly mapping coastal water bathymetry. Water depths of 10 plus or minus 0.25 m were recorded in waters having an effective attenuation coefficient of 0.175 m. A 2-MW peak power Nd:YAG pulsed laser was flown at an altitude of 600 m. An advanced system, incorporating a mirror scanner, a high pulsed rate laser, and a good signal processor, could survey coastal zones at the rate of several square miles per hour.

Kim, H. H.↗

Interplanetary disturbances in the solar wind produced by density, temperature, or velocity pulses at 0.08 AU

Time-dependent solutions of a one-fluid model of the interplanetary medium are investigated. This set of unsteady hydrodynamic equations has been written in conserved form in order to apply the Lax-Wendroff (1960) method for the solution of this problem. The initial disturbance is specified by a pulse at 0.08 AU. Physically, this pulse can be interpreted as having been caused by a solar flare, surge, or any other solar disturbance. The equilibrium condition is determined to be the steady solution of the governing equations and represents the quiet solar wind. Results are presented in terms of density, temperature, and velocity profiles of the interplanetary gas flow at heliocentric distances up to 6 AU at several times. Also, the trajectories of disturbances for various initial pulses are shown. Some June 1972 interplanetary observational data are compared with these theoretical calculations. On the basis of these results, the effects of solar disturbances on the interplanetary environment (such as the generation of large nonlinear wave trains in the shock wakes) can be inferred.

Wu, S. T.↗

Soviet-French working group interpretation of the scientific information during the search for celestial sources of gamma pulses, abstract of reports, 24-30 March 1977

The progress made and techniques used by the Soviet-French group in the study of gamma and X ray pulses are described in abstracts of 16 reports. Experiments included calibration and operation of various recording instruments designed for measurements involving these pulses, specifically the location of sources of such pulses in outer space. Space vehicles are utilized in conjunction with ground equipment to accomplish these tests.

Estulin, I. V.↗

Pulse profile and refined orbital elements for SMC X-1

Results of a reanalysis of SAS-3 data for SMC X-1, including greatly improved orbital elements, are presented. These elements, when combined with newly available data for the optical companion, Sk 160, yield improved estimates for the masses of SMC X-1 and Sk 160. A significant rate of change of intrinsic pulse period is detected during the course of the four-day observation which is consistent with the average value that was previously deduced from observations separated by 5 years. The X-ray pulse profile, averaged over one orbital cycle and with approximately 15-ms time resolution, is also presented. The pulse profile is found to be constant to within statistics, as a function of orbital phase. The implications of the small observed eccentricities of SMC X-1 and other binary X-ray pulsar systems are discussed.

Primini, F.↗

Quantitative effect of initial current rise on pumping the double-pulsed copper chloride laser

The laser energy at optimum time delay of a double-pulsed CuCl laser was experimentally determined to be a logarithmic function of the initial current rise of the pumping pulse over the total circuit inductance range 1 to 12 microhenrys. The minimum delay was found to decrease with initial current rise, which implies that faster rising current pulses are more efficient at pumping copper atoms from the ground state to the upper laser level because lasing threshold occurs with a higher population in the lower laser level.

Vetter, A. A.↗

Calculation of spin-lattice relaxation during pulsed spin locking in solids

The spin-lattice relaxation time has been calculated for dipolar solids in the case where the spins are locked by an RF pulse sequence with pulses of arbitrary angle and finite width. Expressions are given for the homonuclear case in general and for the heteronuclear case in the delta-function limit. The results for the homonuclear case are experimentally confirmed using solid C6F12. The analysis shows that for small pulse angles, at which the direct spin heating effect is known to be small, the relaxation behavior will be identical to the CW irradiation case.

Rhim, W.-K.↗

Scaling a double-pulsed copper chloride laser to 10 mJ

By use of low-inductance (0.5micro H) discharge circuits, pulses of 9.6 mJ were obtained from a double-pulsed CuCl laser. An oscillator-amplifier configuration produced a pulse energy of 11 mJ. Scaling studies indicate that additional increases in the laser energy could be obtained by increasing the discharge voltage above 20 kV and/or by increasing the laser-tube dimensions.

Nerheim, N. M.↗

A continuously pulsed copper halide laser with a cable-capacitor Blumlein discharge circuit

Experimental characteristics of a continuously pulsed copper halide laser with a cable-capacitor Blumlein discharge circuit are reported. Quartz laser tubes 1 m in length and 1.5 and 2.5 cm in diameter were employed to study the effects of the electrical circuit, lasant, and buffer gas on laser performance. Measured properties of the Blumlein circuit are compared with an analytic solution for an idealized circuit. Both CuCl and CuBr with neon and helium buffer gas were studied. A maximum average power of 12.5 W was obtained with a 1.5 nF capacitor charged to 8 kV and discharged at 31 kHz with CuCl and neon buffer gas at 0.7 kPa in a 2.5-cm-diam tube. A maximum efficiency of 0.72 percent was obtained at 9 W average power. Measurements of the radial distribution of the power in the laser beam and the variation of laser power at 510.6 and 578.2 nm with halide vapor density are also reported. Double and continuously pulsed laser characteristics are compared, and the role of copper metastable level atoms in limiting the laser pulse energy density is discussed.

Nerheim, N. M.↗

Directional spectra of ocean waves from microwave backscatter: A physical optics solution with application to the short-pulse and two-frequency measurement techniques

Two simple microwave radar techniques that are potentially capable of providing routine satellite measurements of the directional spectrum of ocean waves were developed. One technique, the short pulse technique, makes use of very short pulses to resolve ocean surface wave contrast features in the range direction; the other technique, the two frequency correlation technique makes use of coherency in the transmitted waveform to detect the large ocean wave contrast modulation as a beat or mixing frequency in the power backscattered at two closely separated microwave frequencies. A frequency domain analysis of the short pulse and two frequency systems shows that the two measurement systems are essentially duals; they each operate on the generalized (three frequency) fourth-order statistical moment of the surface transfer function in different, but symmetrical ways, and they both measure the same directional contrast modulation spectrum. A three dimensional physical optics solution for the fourth-order moment was obtained for backscatter in the near vertical, specular regime, assuming Gaussian surface statistics.

Jackson, F. C.↗

Bit timing with pulse distortion and intersymbol interference

Pulse distortion and intersymbol interference due to insufficient filtering in PCM and PSK channels cause performance degradation in terms of both bit error probabilities and timing errors. This paper reports the results of a study analyzing these effects on bit timing subsystems. Consideration is given to both the filter-rectifier and transition tracking type of timing subsystem. Although both these systems perform similarly in high SNR and ideal pulse models, pulse distortion and intersymbol affects each differently. The primary effects in both systems is to cause the presence of an irreducible mean squared timing error due to the intersymbol which limits the ultimate performance. Design procedures to minimize the anomalies of both systems are presented, and indicate modifications of the standard timing subsystems. It is found that specific design directions depend on whether the intersymbol or the receiver noise tends to dominate.

Gagliardi, R. M.↗

Molecular collision processes in the presence of picosecond laser pulses

Radiative transitions in molecular collision processes taking place in the presence of picosecond pulses are studied within a semiclassical formalism. An expression for adiabatic potential surfaces in the electronic-field representation is obtained, which directly leads to the evaluation of transition probabilities. Calculations with a Landau-Zener-type model indicate that picosecond pulses can be much more effective in inducing transitions than a single long pulse of the same intensity and the same total energy, if the intensity is sufficiently high that the perturbation treatment is not valid.

Lee, H. W.↗

Influence of phase cancellation and pulse shape artifacts on ultrasonic spectrum analysis

Both continuous wave and Fourier transformed pulse ultrasonic spectroscopy are being applied to material and flow characterization. Ideal samples and flaws (flat, parallel, and homogeneous) and ideal ultrasonic apparatus (producing delta function stress waves) provide acoustic spectra which can be partially inverted. However, in the presence of material inhomogeneity, lack of sample flatness or parallelism, or finite risetime pulses, the spectra become quite complex and produce phase cancellations at the transducer as well as pulse shape spectral artifacts. In this paper, we examine the nature of these artifacts for both simple and practical samples. Sample spectra are contrasted for several different transducer/electronic systems. Spectra obtained with a phase insensitive acousto-electric transducer (AET) combined with a frequency tracked tone-burst spectroscopy (TBS) method are presented. Analysis of the test configuration is shown to produce spectra consistent with that obtained with the AET-TBS combination.

Heyman, J. S.↗

Pulse-shaping circuit for laser excitation

Narrower, impedence-matched pulses initiate stabler electric discharges for gas lasers. Discharges are more efficient, more compact, capable of high repetition rate, and less expensive than conventional electron-beam apparatus, but gas tends to break down and form localized arcs. Pulse-shaping circuit compresses width of high-voltage pulses from relatively-slow rise-time voltage generator and gradually grades circuit impedance from inherent high impedance of generator to low impedence of gas.

Laudenslager, J. B.↗

Pulse transducer with artifact signal attenuator

An artifact signal attenuator for a pulse rate sensor is described. The circuit for attenuating background noise signals is connected with a pulse rate transducer which has a light source and a detector for light reflected from blood vessels of a living body. The heart signal provided consists of a modulated dc signal voltage indicative of pulse rate. The artifact signal resulting from light reflected from the skin of the body comprises both a constant dc signal voltage and a modulated dc signal voltage. The amplitude of the artifact signal is greater and the frequency less than that of the heart signal. The signal attenuator circuit includes an operational amplifier for canceling the artifact signal from the output signal of the transducer and has the capability of meeting packaging requirements for wrist-watch-size packages.

Cash, W. H., Jr.↗

DIAL with heterodyne detection including speckle noise: Aircraft/shuttle measurements of O3, H2O, and NH3 with pulsed tunable CO2lasers

A parametric analysis of DIAL sensitivity with heterodyne detection is presented and comparisons with direct detection are discussed. Examples are given for monitoring vertical distributions of O3, H2O, and NH3 using a ground-, aircraft-, or shuttle-based pulsed tunable CO2 laser DIAL system. Results indicate that maximum sensitivity at minimum laser energy per measurement requires multiple pulse operation with the energy per pulse selected so that the measured photon rate is approximately equal to the detector IF bandwidth. Measurement sensitivities can be maximized and interference effects minimized by fine adjustment of measurement frequencies using the tunability of high pressure lasers. The use of rare isotope lasers minimizes loss due to CO2 atmospheric absorption.

Brockman, P.↗

Highly flexible pulse programmer for NMR applications

A pulse generator for NMR application is described. Eighteen output channels are provided to allow use in single and double resonance experiments. Complex pulse sequences may be generated by loading instructions into a 256-word by 16-bit program memory. Features of the pulse generator include programmable time delays from 0.5 micros to 1000 s, branching and looping instructions, and the ability to be loaded and operated either manually or from a PDP-11/10 computer.

Dart, J.↗

Pulsed eddy current testing

Since a large number of the procedures used for inspecting the external tank are concerned with determining flaws in welds, there is a need to develop an inspection technique, which can be automated, to determine flaws in welds and structures with complex geometries. Techniques whereby an eddy current is generated in a metallic material and the changes in the circuit parameters due to material differences are observed, were chosen as one possible approach. Pulsed eddy current and its relationship to multifrequency techniques is discussed as well as some preliminary results obtained from observing pulsed waveforms with apparatus and algorithms currently in use for ultrasonic testing of welds. It can be shown the pulsed eddy current techniques can provide similar results, can eliminate some of the noncritical parameters affecting the eddy current signals, and can facilitate in the detection of critical parameter such as flaws, subsurface voids, and corrosion.

Workman, G. L.↗