Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV inverters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Enhanced Control, Optimization, and Integration of Distributed Energy Applications (ECO-IDEA)

With support from the U.S. Department of Energy Solar Energy Technologies Office, the National Renewable Energy Laboratory (NREL) partnered with Xcel Energy, Schneider Electric, Varentec, and Electric Power Research Institute (EPRI) to meet the goals of the Enabling Extreme Real-Time Grid Integration of Solar Energy (ENERGISE) program. This project developed and validated an innovative data-enhanced hierarchical control architecture that enables the efficient, reliable, resilient, and secure operation of future distribution systems with a high penetration of distributed energy resources like solar energy. The architecture enables a hybrid control approach where a centralized control layer is complemented by distributed control algorithms for solar inverters and autonomous control of grid edge devices. It is fully interoperable and includes all the cybersecurity aspects necessary for reliable and secure system operation. The hybrid approach can seamlessly integrate multiple voltage-regulation technologies, both at central and grid-edge levels, which enables reliable and efficient system operation in the face of unpredictable conditions. The overarching goal of the Eco-Idea project is to develop, validate, and deploy a unique and innovative Data-Enhanced Hierarchical Control (DEHC) architecture that comprehensively addresses the formidable challenges associated with proliferation of high penetration of distributed PV such as reverse power flows, transients from variability of PV systems, feeder load balancing, and voltage stability. These issues are exposing the weaknesses of existing grid operations and controls - including, but not limited to, lack of grid situational awareness, heuristic and slow-acting control actions, latency of control for emergency situations, and points of failure in communications. The proposed architecture will comprehensively resolve the deficiencies of current operational settings - where monitoring and control solutions proposed across industry and academia may not be interoperable and may not coexist in the same system - and will enable an efficient, reliable, resilient, and secure operation of future distribution systems with penetration of solar energy well beyond current limits. The DEHC architecture was developed and validated rigorously through hardware-in-loop simulations in the laboratory environment and deployed on the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Analysis Framework for Distribution Network DER Integration Analysis in India: Distributed Solar in Tamil Nadu

This report is part of a two-part series that represents a year-long collaboration with the Tamil Nadu Generation and Distribution Corporation Limited (TANGEDCO) on power sector planning. The first report in this series, the Pathways for Tamil Nadu’s Electric Power Sector 2017-2030 report outlines NREL’s work with TANGEDCO's electricity sector planning department to develop a model of the State’s power system and evaluate multiple scenarios of system growth given resource constraints, costs of technologies, and power sector policies. This second report in this series focuses on the rapidly transforming distribution network in the State. The report outlines a framework developed by NREL with TANGEDCO's distribution utility to quickly and accurately analyze the impacts of integrating renewable energy, specifically rooftop solar PV onto Tamil Nadu's distribution system. Together these studies help to prepare Tamil Nadu for a rapidly transforming power system.

14 SOLAR ENERGY↗

CRADA Final Report: Open Microgrid Platform

Current microgrid control technology is mostly proprietary, expensive, and inflexible. An open-source, vendor-neutral, publish-subscribe controller will significantly lower the barrier to entry for new technologies and market entrants: inverter, battery, and load control manufacturers; cloud and services providers; and energy aggregators. An OpenFMB controller can significantly reduce the acquisition, integration, and ongoing operating and maintenance costs and increase revenue opportunities for energy producers and consumers. It allows distributed energy resource (DER) owners to replace individual DER components as richer-function, lower-cost devices become available or to incorporate new forecast and optimization algorithms as they are developed. A standard, secure, full-function DER field controller will also provide a low-cost means for grid operators to effectively manage the variability and uncertainty of solar photovoltaics (PV). Under the terms of this CRADA, ORNL has worked with Open Energy Solutions (OES) to advance the transition of ORNL’s existing open-source microgrid controller into a platform geared toward mainstream implementation. Using a more prevalent and memory-safe programming language, Rust, OES has converted ORNL’s current generation on-grid optimization into an application more suitable for industry use. The results of the ported optimization were analyzed by inputting the same arguments in both the current-generation and next-generation optimizers and verifying that the results were equivalent.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Frequency Support Scheme of Generic Inverter-Based Resource Models for Renewable-Dominated Power Grids

The frequency response of SG-dominated power grids is predictable ahead of an occurrence of a frequency event because the frequency response of SGs is consistent, and it can be inferred from the swing equation [1]. However, increasing the portion of IBRs in an SG-dominated power grid might make the characteristics of the conventional power grids no longer valid because this changing resource mix affects grid dynamics and controls [2]. Thus, maintaining these characteristics greatly benefits the control and operation of the power grids with high penetration of IBRs. To maintain these characteristics in IBR-dominated power grids, IBRs should have frequency response capability similar to that of an SG. The WECC modeling validation subcommittee has developed generic IBR models for large system planning [3]-[5]. These models can represent various vendors' dynamic behavior for WTG, PV, and ESS [5]. The current generic IBR models approved by WECC can provide frequency response only from droop control loops in REPC models [6], [7]. The contribution of the loops is proportional to the frequency deviation from the nominal frequency. Thus, it presents an insufficient contribution to arrest frequency variation compared to the frequency response of SGs because it allows a high ROCOF in the early stage of frequency events. This shortfall will become greater as the PL of IBRs increases in power grids. Controller enhancement for the generic IBR models is required to secure the frequency stability under high PL of IBRs as in the SG-dominated power grids. This paper proposes a control extension for the generic IBR models to enhance the frequency support capabilities and discusses the classification of frequency support for the different types of IBR considering their operating constraints. An inertial control scheme is implemented in the REPC and REEC models of the generic IBR models to achieve these objectives. The inertial control scheme includes the following stages: Control area data acquisition, inertia time constant estimation, IBR-related constraint check, IBR contribution determination, and inertial response provision. In the scheme, a REPC acquires control area data from a system operator and estimates a total inertia time constant for the control area the applicable IBR power plant belongs. Then, the estimated inertial time constant is transferred to each IBR controller—REEC—within the power plant. Each REEC checks the availability of applicable IBR for inertial response participation. If the IBR is available, the REEC amplifies the estimated inertial time constant to utilize it for inertial response provision. In this way, the proposed inertial response scheme extends the functionality of the generic IBR models to provide SG-like frequency response within their constraints. Various scenarios considering different IBR types, IBR penetration levels, and frequency control schemes were simulated and compared in an IEEE 39-bus system using PSCAD simulator to verify the effectiveness of the proposed scheme.

Kim, Jinho↗

RE-INTEGRATE EMT Simulation Software: Graph Convolutional Network for Sparse Matrix Pattern Detection

The increasing complexity of power networks, driven by proliferation of inverters, presents analytical challenges that simplified models often fail to capture, necessitating Electromagnetic Transient (EMT) simulations. EMT models are represented as discretized differential-algebraic equations (DAEs), forming a linear system Ax = b that is computationally intensive to solve. Due to inherent sparsity of adjacency matrix A, distinct patterns emerge that, when accurately identified, enable efficient solver selection to minimize computation time. However, identifying ideal pattern is complicated by numerous reordering algorithms and limited structural insights. To address this, we introduce a Graph Convolutional Network (GCN) model for classifying sparse matrix patterns common in power system analysis. The model, achieving 96% test accuracy, is validated using PV plant models of 125 MW capacities connected to New England 39-bus transmission system (TS), and further scaled to a 4,992-bus network with 384 PV plants, yielding 191, 616 × 191, 616 sized A matrix. For all cases, the GCN model accurately identifies the matrix’s intrinsic sparse pattern, demonstrating its potential to enhance solver performance in EMT analysis.

Hossain, Md Rifat [Florida International Universit↗

PV O&M Cost Model [SWR-21-14]

This tool presents a method for calculating costs associated with the operation and maintenance (O&M) of photovoltaic (PV) systems. The tool compiles details regarding the cost and frequency of multiple O&M services to estimate annual O&M costs ($/year) for each year of an analysis period, the net present value ($) of life cycle costs accumulated over the analysis period, and the reserve account amount ($) that might be required to fund unexpected repairs. The reserve account includes parts inventory and is important for providing a source of funds to make repairs quickly and avoid lost production. This method allows a detailed selection of services to perform based on system size, market served (e.g., residential, commercial, or utility), type and configuration of system components (e.g., micro-, string, or central inverter), and site and environmental conditions (e.g., pollen, bird populations) which is an improvement over simple per unit valuations of O&M costs ($/kW/year). This model also distinguishes costs that vary from year to year and increase at different rates over time as modeled by heuristic failure distributions (e.g., Weibull or Lognormal distribution) based on actuarial data for many of the services.

Walker, Andy↗

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

Development of High-Efficiency GaAs Solar Cells Grown on Nanopatterned GaAs Substrates

One approach to reducing the cost of high-efficiency III–V devices involves adding patterned layers to heteroepitaxial or homoepitaxial substrates to facilitate substrate removal and reuse. However, few studies have focused explicitly on high-quality devices grown over patterned substrates, which is required for any cost saving to be beneficial. In this work, we demonstrate the growth of high-efficiency GaAs solar cells on GaAs substrates patterned with an array of nanoscale SiOX mask stripes. We show that reducing the pattern dimensions to submicron length scales with nanoimprint lithography enables defect-free coalescence. By varying the growth conditions, faceting of the epilayer material during overgrowth of the patterned mask was also controlled. A V/III ratio of 200 during MOVPE overgrowth produced smooth coalesced epilayers, which is desirable for the growth of subsequent device layers. Inverted GaAs front homojunction devices grown on patterned GaAs(001) substrates achieved threading dislocation densities below 5 × 10 5 cm –2 and maintained >23% solar cell efficiencies at one sun illumination, equivalent to control devices grown on unpatterned epi-ready substrates.

14 SOLAR ENERGY↗

Enhancement of Distribution System Resilience Through the Application of Volt-Var Regulation Devices

This paper discusses a practical implementation of locating and sizing dynamic reactive compensation using an impedance matrix (Zbus) approach to improve distribution system resilience in scenarios with high penetration of distributed resources. The modeled system is a 14.2 kV radial residential system modified to be fed by a combination of traditional sources and solar resources. Time-varying loads and PV sources are connected along the feeder to simulate the challenging operational voltage regulation scenarios faced by Modern Distribution Systems. Additionally, enhancement of the resilience of the electrical system is demonstrated through analyzing the effect of a topology change to the system. This study uses the GridLAB-D software.

42 ENGINEERING↗

Understanding Solar Photovoltaic System Performance: An Assessment of 75 Federal Photovoltaic Systems

This report presents a performance analysis of 75 photovoltaic systems based on PV system production data collected as part of a FEMP Federal PV Performance Assessment project combined with co-incident insolation, and ambient temperature to analyze how actual performance compares with a performance model. FEMP collaborated with 17 Federal agencies and sub-agencies to collect the information required to analyze the performance of each system. The systems represent a total capacity of 30,714 kW and range in size from 1 kW to 4,043 kW, with an average size of 410 kW, and were installed between 2011 and 2020. The data is analyzed for Key Performance Indicators, Availability, Performance Ratio and Energy Ratio by comparing the measured production data to model production data. The System Advisor Model (SAM) combines a description of the system (such as inverter capacity, de-rating for temperature, balance-of-system efficiency) with environmental parameters (coincident solar and temperature data) to calculate predicted performance. The performance metrics are calculated by lining up the measured production data with the model estimate on an hour-by-hour, day-by-day, or month-by-month basis (depending on the interval resolution of the production data). A report with system description, photo of the system, special assumptions made for the site, graph of measured production and model production, table of key performance indicators, and links to O&M resources that might improve performance was produced and delivered to site and agency staff with a short on-line briefing.

14 SOLAR ENERGY↗

The roles of learning mechanisms in services: Evidence from US residential solar installations

Non-hardware costs are majority of the cost of producing solar photovoltaic (PV) electricity. Here we use matched data on patents and over 125,000 residential PV installations to estimate the effects of three learning mechanisms in reducing PV costs: learning by doing, searching, and interacting. While previous work in this area has focused predominantly on learning by doing, we find that learning by searching and interacting are also significant mechanisms to facilitate non-hardware cost reductions. Including these two mechanisms reduces the effect of learning by doing in explaining non-hardware cost reductions by 43%. Our results suggest that prior work may overemphasize the role of learning by doing and the policies that help generate learning by doing. Analysis of the supplier-network between installers and their suppliers shows that concentrated supplier networks are associated with lower non-hardware costs, although there are key differences between installer-panel and installer-inverter manufacturer networks. An important implication is that policies for reducing non-hardware costs need to take a more complete view of how different learning mechanisms engender cost reductions. They should particularly consider the important role of learning in supplier networks in cost reductions—an effect that until now has largely been missing in analyses of solar non-hardware costs.

14 SOLAR ENERGY↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices: Preprint

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Triple-junction solar cells with 39.5% terrestrial and 34.2% space efficiency enabled by thick quantum well superlattices

Multijunction solar cell design is guided by both the theoretical optimal bandgap combination as well as the realistic limitations to materials with these bandgaps. For instance, triple-junction III-V multijunction solar cells commonly use GaAs as a middle cell because of its near-perfect material quality, despite its bandgap being higher than optimal for the global spectrum. Here, we modify the middle cell bandgap using thick GaInAs/GaAsP strain-balanced quantum well (QW) solar cells with excellent voltage and absorption. Additionally, these high-performance QWs are incorporated into a triple-junction inverted metamorphic multijunction device consisting of a GaInP top cell, GaInAs/GaAsP QW middle cell, and lattice-mismatched GaInAs bottom cell, each of which has been highly optimized. We demonstrate triple-junction efficiencies of 39.5% and 34.2% under the AM1.5 global and AM0 space spectra, respectively, and the global efficiency is higher than previous record six-junction devices.

14 SOLAR ENERGY↗

Advanced Distributed Wind Turbine Controls Series: Part 1-Flatirons Campus Model Overview – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

Wind turbines are typically deployed to provide energy, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL), it is demonstrated that advanced wind turbine controls can be employed to support higher contributions of wind, and to demonstrate ways that wind can play a role in supporting grid stability in islanded or grid-connected configurations. This paper documents models of various subsystem comprising a portion of NREL's Flatirons campus that will be used in three subsequent reports to demonstrate capabilities of advanced wind turbine controls. The series of reports will detail advanced capabilities of distributed wind turbines to provide support to isolated grids, distribution grids, and microgrids. We developed models to simulate a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a diesel generator (2 MW) and various types of loads (critical, dynamic). The model of the subsystems in MATLAB/Simulink are validated with available data from real-world components on NREL's Flatirons Campus. These validated models can be configured for various studies including four MIRACL use cases: 1) isolated grids, 2) microgrids, and 3) behind-the-meter, and 4) front-of-the-meter wind turbine deployments.

17 WIND ENERGY↗

Insights into Methodologies and Operational Details of Resource Adequacy Assessment: A Case Study with Application to a Broader Flexibility Framework

Assessing and maintaining resource adequacy (RA) is a core pillar of power systems. However, recent changes in the physical makeup of these systems and the conditions under which these systems must operate have yielded a renewed interest in the methods, metrics, and assumptions that underpin RA assessments. In this paper, we systematically explore a wide range of RA modeling dimensions, including: the objective function and level of operational detail in the underlying model formulation; the quantity (look-ahead) and quality (accuracy) of data that is available for making operational decisions within those models; and the physical configuration of solar photovoltaics (PV) with battery storage hybrid resources. We apply a set of probabilistic RA tools and production cost modeling tools to a realistic test system based loosely on a future Electric Reliability Council of Texas power system dominated by solar PV resources. Under the assumptions of our system and models, we find that multi-stage probabilistic assessments may provide a more robust evaluation of RA by capturing a wider range of operational and system interactions, but this comes at a computational cost of 1-2 orders of magnitude longer run time depending on the specific configuration. In addition, the information on thermal generator availability impacts RA performance by an order of magnitude more than solar resource forecasts, which is driven by the comparatively larger magnitude of thermal outages than solar forecast errors within our test system. Lastly, the flexibility provided by hybrid and other resources can help reduce system load-shedding event frequencies and enable the system to be more robust to inaccurate forecast information, and alternative hybrid inverter sizes can impact RA levels by 1-2 orders of magnitude. Our results point to the importance of a broader flexibility framework to describe the interaction between (1) flexibility "supply" from both physical resource capabilities and operational constraints considered in the modeling, and (2) flexibility "demand" from forecast errors, thermal generator outages, and other sources of uncertainty, as well as their RA impacts. Results are likely sensitive to the system buildout explored; future work could consider additional system configurations and conditions.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Characterizing Current THD’s Dependency on Solar Irradiance and Supraharmonics Profiling for a Grid-Tied Photovoltaic Power Plant

The rapidly increasing distributed energy resources (DERs) in power systems are now getting interconnected to set community grid structures, where power quality will be a major concern. The grid-to-grid (G2G) bidirectional power transfer among the distribution microgrid will not be considered commercially feasible unless the upstream harmonics are under the limits. The aggregation of such harmonics, measured as total harmonic distortion (THD), is feared to be beyond tolerable limits with the progression of rooftop grid-tied PV-like installations. Hence, this THD needs to be characterized with DER generation end variables. In this work, the photovoltaic (PV) DERs’ dependency on environment variables such as irradiance was profiled in the context of generating and injecting harmonics into the grid. A mathematical model of a grid-tied three-phase PV DER was developed as part of this correlation characterization, matching the fundamental unit structure of a 1.4 MW solar canopy located on the Florida International University (FIU) Miami campus. To determine the qualitative association with produced THD patterns, the model was evaluated with various irradiance settings. A real-time digital simulation (RTDS) platform was used to verify it. Following this confirmation, sets of data from power quality meters at the point of common coupling and FIU field sensors were utilized to validate further the correlation model. The results showed that the grid current’s THD exhibited a high correlation with the irradiance profile and its variation over time. The early morning and late afternoon periods of the day, associated with a low irradiance, constantly had higher harmonics generated from the PV DER. The midday THD was rather rational with partial shadings, hence a geolocation-dependent factor. These findings were verified by an RTDS and validated by real field data. In quantifying the THD injected by a single DER at a high-frequency (2–150 kHz) supraharmonics (SH) level, a 3% peak increment in magnitude was observed from the high-fixed to the low-fixed irradiance profile. The correlation characteristics depicted that the hybrid microgrid suffered from a daytime-dependent harmonic insertion from the grid-tied DER. This is a global problem unless specific measures are taken to mitigate the harmonics. The electrically notorious higher-frequency SH was found to increase proportionally. The G2G power transfer can be limited because of the higher THD in the early morning and late afternoon, which will also worsen because the numbers of grid-tied PV DERs (i.e., rooftop solar and industrial solar) are likely to increase rapidly soon. The community grid structure can thus have a controlled harmonics filtration setup purposefully designed to address the findings of this work, which also fall within the scope of our future research.

14 SOLAR ENERGY↗

Enabling Extended-Term Simulation of Power Systems with High PV Penetration. Final Report

This is the final Technical Report for DOE-SETO Project Award # DE-EE0036461. The goal of this project is to advance the understanding of the grid impact of high penetration of photovoltaic (PV) generation by developing novel numerical methods to solve the differential algebraic equations (DAEs) that define power systems. This will overcome the limitations of current software packages – namely that they only consider fast dynamics over brief time periods. The work presented in this final project report covers results over the entire period of the project. This includes results on model development, code development for the PST repository, datasets in the PST repository, algorithm development and results from variable time-step simulations, development and results from multirate simulations, and sensitivity analysis of key parameter in variable time-step methods. In addition, this report discusses project outreach activities to stakeholders, and a summary of project products. Also covered in this final report is the writing of two conference papers (one of which has already been accepted) and a journal paper. In addition, the updating of two inverter models (both grid forming and grid following) to be compatible with the latest version of PST software is discussed.

14 SOLAR ENERGY↗