Insights from PVEL's Indoor and Outdoor Bifacial Testing
Webinar presentation of indoor lab and outdoor field testing of bifacial PV modules.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Webinar presentation of indoor lab and outdoor field testing of bifacial PV modules.
Energy transition to carbon-free electricity is a crucial pillar of the Circular Economy. Renewable energy reduces environmental impacts and decarbonizes the production of other goods. But, manufacturing renewable energy sources, such as photovoltaic (PV) modules, require energy inputs that are currently carbon intensive. So, how do we decarbonize and circularize these critical technologies to achieve a sustainable energy transition? This work proposes that effective capacity-the installed capacity accounting for degradation rates and failures-is a critical metric to evaluate renewable energy technologies on the path toward circular economy and energy transitions. Our analyses also emphasize the importance of examining a suite of metrics incorporating mass and energy flows to identify potential tradeoffs and inform design or lifecycle management decisions holistically.
Backsheet cracking is among the most commonly observed degradation modes of photovoltaic (PV) modules in the field. Cracks can reduce the ability of backsheets to fulfil their functions, for example, protection of the modules from the environment or electrical insulation. This work presents an evaluation of the degradation and cracking propensity of two backsheets during accelerated IEC TS 62788-7-2 A3 (International Electrotechnical Commission) aging with the fragmentation test: a co-extruded polyamide backsheet (AAA), and a laminated multilayer backsheet with a polyethylene terephthalate core and outer layer and ethylene vinyl acetate inner layer (PPE). Results show the surface embrittlement of the AAA outer layer during exposure. A longer time of exposure causes cracks to form at lower strains during stretching and creates deeper cracks. Accordingly, Young's modulus of the outer layer increases, as measured by cross-sectional nanoindentation. PPE exhibits cracking after exposure as well. While no similar increase of modulus or crack depth can be observed, the outer layer of PPE exhibits more obvious signs of erosion during exposure, including progressive morphological changes and thickness losses. A finite element model to simulate surface crack formation is devised, based on initially zero-thickness decohesion elements. Decohesion criteria define a critical stress, at which these elements grow, and cracks can begin to form. These criteria are obtained via parameter optimization by comparison between simulation and experiment. The model is used to interpret crack formation in both backsheets.
Energy transition to carbon-free electricity is a crucial pillar of the Circular Economy. Renewable energy reduces environmental impacts and decarbonizes the production of other goods. But, manufacturing renewable energy sources, such as photovoltaic (PV) modules, require energy inputs that are currently carbon intensive. So, how do we decarbonize and circularize these critical technologies to achieve a sustainable energy transition? This work proposes that effective capacity-the installed capacity accounting for degradation rates and failures-is a critical metric to evaluate renewable energy technologies on the path toward circular economy and energy transitions. Our analyses also emphasize the importance of examining a suite of metrics incorporating mass and energy flows to identify potential tradeoffs and inform design or lifecycle management decisions holistically.
This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.
By applying multiple environmental stresses in fieldrepresentative combinations and sequences, combined-accelerated stress testing (CAST) identifies degradation modes and failure mechanisms of photovoltaic (PV) modules and components that are missed by single stress factor accelerated testing.
In one respect, disclosed is an in-situ current-voltage (I-V) measurement device for photovoltaic modules in a photovoltaic array, comprising a variable load, wherein the variable load is configured to be connected in parallel with a module, wherein the module is connected in series with at least one other module in a string, such that the module supplies current simultaneously to the string and to the variable load, and wherein the variable load is controlled by a controller, and wherein the controller is configured to shift an I-V operating point of the module, based at least upon varying the variable load.
The Photovoltaic (PV) industry constantly aims for lower costs, higher-efficiency cells, and improved module designs. These trends lead to using new materials, designs, and manufacturing processes, resulting in a continually changing technological landscape. These changes can potentially introduce new, unknown degradation mechanisms and failure modes that are difficult to diagnose, analyze, test, and model. This introduces uncertainty into the expected lifetime of PV modules of 25 years. Furthermore, research efforts aim for up to 50 years of service life while keeping performance degradation at a minimum for decades of outdoor weathering - putting additional pressure on improving the accuracy of long-term durability and reliability assessments. Here there is a need to organize the existing degradation data into an accessible format and to provide industry relevant tools for extrapolation from laboratory to field conditions. Because the core of this type of analysis involves calculations that are complicated but ubiquitous for many degradation processes, an enhanced predictive modeling framework will facilitate the analysis to help researchers keep up with the rapid pace of technological changes. In this work, we present an online tool that can be used to search for and analyze degradation information and extrapolate PV module performance and durability to field exposure. A graphical user interface will aid in the understanding of the results. The prediction tool will be built modular and published as open source, enabling users to expand on the existing framework. We use an integration pipeline approach that allows us to leverage weather data from the National Solar Radiation Database to perform geospatial degradation analysis in the US and worldwide. Our repository will contain various degradation models and material parameters suitable for the reliability and durability assessment of materials and components deployed outdoors. We hope to become a repository that can be used for weathering and degradation analysis for various applications beyond the PV industry.
Photovoltaic (PV) energy yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. We have reported on direct measurements-using atomic force microscopy (AFM)-of strong electric-field-induced attraction and adhesion force (Fes) of dust particles onto solar panel that are 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, corroborated by observing the increase in system voltage-induced soiling rate. Here, we report another characteristic of Fes on soiling-long lasting or slow decay after turning off the high voltage applied to solar panels. The Fes decay time varies in a wide time range of 1 to 10 hours, depending on two factors: 1) either/both the cell or/and particle were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off-either connected through the power supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting Fes for hours can significantly affect the solar panel soiling after sunset, especially combined with water condensation.
Photovoltaic (PV) energy-yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. The electrostatic attraction and adhesion force (F es ) of dust particles by the high voltages from solar panels have been reported to be 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, which has been corroborated by observing the increase in system voltage-induced soiling rate by setting up an outdoor test. Here, we report another characteristic of F es on soiling - long-lasting or slow decay after turning off the high voltage applied to solar panels. The F es decay time varies across a wide time range of 1 to 10 h, depending on two factors: 1) whether the cell, the particle, or both were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off - either connected through the power-supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting F es for hours can affect the solar panel soiling after sunset, and it can have an even greater effect when combined with water condensation at night.
Explore the source record for details and available documents.
The U.S. Department of Energy’s solar office and its national laboratory partners analyze cost data for U.S. solar photovoltaic systems to develop cost benchmarks to measure progress toward goals and guide research and development programs. The cost data is available in an Excel spreadsheet model that can be downloaded here.
The objective of this study is to complete a life cycle assessment (LCA) of a novel technology that separates the crystalline silicon (c-Si) photovoltaic (PV) module front glass from the backsheet using hot knife technology. This is known to be the most challenging step in module recycling, where the choice of delamination approach can determine the process selection for the next steps of the recycling process, the economic value of the recovered materials, and environmental performance. The life cycle inventory (LCI) reported here is based on primary data from the technology manufacturer. Different LCIs are established following the cut-off approach and the end-of-life (EOL) approach. The environmental impacts of the hot knife delamination process are analysed based on six indicators, and the main contributors to delamination efforts are identified. For the EOL approach, the potential environmental benefits from the recovered materials are compared to the environmental impacts caused by the delamination process. The functional unit of this analysis is the delamination of 1 kg of used framed c-Si PV modules at the place of installation.
DOE's PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial performance loss rates due to effects like light-induced degradation (LID) and light & elevated temperature-induced degradation (LeTID). To accurately characterize the initial field performance loss requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement. Current samples deployed and monitored in this way include Jinko Solar (2016), Trina Solar (2016), Hanwha Q-Cells (2017), Panasonic (2018), LG (2018), Canadian Solar (2018), Mission Solar (2019). More recently, modules from Sunpreme (2019), and LONGi (2020) have been deployed but not yet analyzed. Overall annual performance loss rates are as follows: our first modules to be deployed (Jinko and Trina) have annual median performance loss rate between -0.4%/yr and -0.9%/yr, mainly concentrated in the first year. The QCells mono-PERC and multi-PERC modules have an annual degradation rate of -0.76%/yr and -0.69%/yr respectively, also concentrated in the first year of operation. Panasonic and LG modules displayed negligible performance loss in the past two years, at 0.1%/yr and -0.0%/yr respectively. They also were the only modules with initial IV curve measurements consistently above the nameplate rating. Possibly relatedly, these are also the only two N-type silicon module types analyzed so far. Canadian Solar multi-PERC modules demonstrated a -1.3%/yr degradation rate which actually accelerated in the past year, so this will be a module type to monitor in future years. Mission Solar modules exhibited strong recoverable performance loss, consistent with LeTID susceptibility. (The same is true for the Jinko JKM260 module type). Annual performance loss actually showed improvement in time at +0.3%/yr after 2 years in the field, although the module initially was measured at 3% below nameplate rating. These modules could therefore be experiencing a form of post-LeTID recovery. Initial measurements have been conducted on the next two module types - Sunpreme n-HIT and LONGi bifacial mono-PERC. We will report on initial year-1 performance change for these modules in the next PV Lifetime annual report. For the remaining modules, an additional year of field exposure will provide greater certainty in annual degradation rates, particularly for those with degradation concentrated in the initial year of field deployment.
The present work is a continuation of the 2020 IEA PVPS Task 12 Human Health Risk Assessment Methods for PV Part 3: Module Disposal Risks. The 2020 report performed a human health risk assessment (HHRA) for disposal of a cadmium telluride (CdTe) PV module in an unlined landfill, focusing solely on risks from cadmium. This study extends the 2020 HHRA on CdTe PV, analyzing eleven constituent elements: Cd, Se, Te, Cu, Si, Cr(III), Mo, Sn, Zn, Ni, and Al. The present HHRA was performed through two methods: utilization of the U.S. Environmental Protection Agency's (USEPA) Delisting Risk Assessment Software (DRAS V.4.0) on eight exposure pathways for cancer risk and non-cancer hazards; and comparison of exposure point concentrations to federal standards for groundwater, surface water, air, and soil exposure pathways. Cancer risks and non-cancer hazards posed by elemental leaching through all evaluated exposure pathways, using both methods, were found to be several orders of magnitude below USEPA health-protective thresholds. Cadmium exhibited both the highest risks and lowest uncertainty considering data availability on chemical content, leachate, and federal screening levels.
Photovoltaic (PV) reference cells, modules, and arrays respond in a complex manner to the many variables that define their operating environment. PV reference cells for irradiance measurement have similarities but also differences to operational PV modules. For this reason, a more neutral and a well-defined generic PV reference cell is needed, whose characteristics are close enough to most operational PV devices to make stable performance indicators possible but whose characteristics are not necessarily identical to any of them. This poster describes a new well-defined reference quantity for outdoor PV measurements, called the baseline performance reference (BPR).
This paper introduces the implementation of electromagnetic transient (EMT) simulations of a photovoltaic (PV) inverter module using the Implicit-Explicit (ImEx) solver in the Suite of Nonlinear and Differential/Algebraic Equation Solvers (SUNDIALS). This study demonstrates the effectiveness of the ImEx solver in overcoming the challenges inherent in simulating the complex dynamics of PV inverter modules. Furthermore, using SUNDIALS’ ImEx solver module ARKODE for EMT simulation automates key aspects of the process, such as numerical integration, providing substantial benefits including enhanced consistency, faster implementation, reduced human error, and the capability to handle the complexities of advanced numerical integration. By conducting comparative simulations with an implicit method used in commercial software, the research showcases the ImEx solver’s capability in achieving high accuracy and reliability. Results indicate that leveraging the ImEx approach significantly enhances modeling fidelity and reduces simulation setup times, offering a promising tool for the EMT analysis of PV inverter systems in power electronics-dominated power grids.