SEARCH · Search NASA
Results for “Padding”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The Energy Storage Test Pad at Sandia's Distributed Energy Technologies Laboratory.
Abstract not provided.
Numerical Simulations of Gas Production from Gas Hydrate Reservoirs at the Prudhoe Bay Unit 7-11-12 Pad on Alaska North Slope
In December 2018, a partnership between the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL), the Japan Oil, Gas and Metals National Corporation (JOGMEC), and the U.S. Geological Survey (USGS) successfully drilled and logged the Hydrate-01 Stratigraphic Test Well (STW) in the greater Prudhoe Bay oil field on Alaska North Slope. The logging-while-drilling (LWD) data confirmed the presence of gas hydrate-bearing reservoirs within two sand reservoirs (Unit B and Unit D) that are suitable targets for future testing. The interpreted log data and core sample measurements were used to create reservoir models for the Prudhoe Bay Unit (PBU) Kuparuk 7-11-12 Site. The models combine both gas hydrate-bearing sections in Unit B and Unit D together with the intermediate Unit C and over- and underburden sands and shales. The vertical heterogeneity in porosity, gas hydrate saturation, and permeability distributions for reservoir and non-reservoir units was implemented using fine mesh discretization. The depressurization method was applied to Unit B to induce gas hydrate destabilization at constant bottom hole pressure (BHP) values. The results of the numerical simulations support the development of production scenarios, well design, surface facilities, and field test procedures with the main goal to perform efficient and safe scientific production testing. Project results contribute to the knowledge base of permafrost-associated gas hydrate accumulations as a future energy source.
Ambient Air Monitoring of Well Pads During Drilling Activities
A&WMA’s 114th Annual Conference & Exhibition, Virtual, June 14-17, 2021
Quantifying Methane Emissions from Marcellus Shale Oil and Gas Well Pads During Pre-Production Activities
Annual American Meteorological Society Meeting, Denver, CO, January 8-12, 2023
Sensitivity Analysis of Gas Hydrate Reservoir Productivity at the Prudhoe Bay Unit Kuparuk 7-11-12 pad on Alaska North Slope
AGU Fall Meeting 2022, Chicago, IL, December 12-16, 2022
Numerical Simulations of Gas Hydrate Reservoir Productivity Using 2D and 3D Reservoir Models of the Prudhoe Bay Unit Kuparuk 7-11-12 Pad on the Alaska North Slope
For presentation at the 10th International Conference on Gas Hydrates, Singapore, July 10-14, 2023.
EFFECT ON 105KW NORTH WALL DUE TO ADDITION OF FILTRATION SYSTEM
CHPRC D&D Projects is adding three filtration system on two 1-ft concrete pads adjacent to the north side of existing KW Basin building. This analysis is prepared to provide qualitative assessment based on the review of design information available for 105KW basin substructure. In the proposed heating, ventilation and air conditioning (HVAC) filtration pad designs a 2 ft gap will be maintained between the pads and the north end of the existing 1 05KW -Basin building. Filtration Skids No.2 and No.3 share one pad. It is conservative to evaluate the No.2 and No.3 skid pad for the wall assessment. Figure 1 shows the plan layout of the 105KW basin site and the location of the pads for the filtration system or HVAC skids. Figure 2 shows the cross-section elevation view of the pad. The concrete pad Drawing H-1-91482 directs the replacement of the existing 8-inch concrete pad with two new 1-ft think pads. The existing 8-inch pad is separated from the 105KW basin superstructure by an expansion joint of only half an inch. The concrete pad Drawing H-1-91482 shows the gap between the new proposed pads and the north wall and any overflow pits and sumps is 2-ft. Following analysis demonstrates that the newly added filtration units and their pads do not exceed the structural capacity of existing wall. The calculation shows that the total bending moment on the north wall due to newly added filtration units and pads including seismic load is 82.636 ft-kip/ft and is within the capacity of wall which is 139.0ft-kip/ft.
An Empirical Model of Radiation Belt Electron Pitch Angle Distributions Based On Van Allen Probes Measurements
Based on over 4 years of Van Allen Probes measurements, an empirical model of radiation belt electron equatorial pitch angle distribution (PAD) is constructed here. The model, developed by fitting electron PADs with Legendre polynomials, provides the statistical PADs as a function of L-shell (L = 1–6), magnetic local time, electron energy (~30 keV to 5.2 MeV), and geomagnetic activity (represented by the Dst index) and is also the first empirical PAD model in the inner belt and slot region. For megaelectron volt electrons, model results show more significant day-night PAD asymmetry of electrons with higher energies and during disturbed times, which is caused by geomagnetic field configuration and flux radial gradient changes. Steeper PADs with higher fluxes around 90° pitch angle and lower fluxes at lower pitch angles for higher-energy electrons and during active times are also present, which could be due to electromagnetic ion cyclotron wave scattering. For hundreds of kiloelectron volt electrons, cap PADs are generally present in the slot region during quiet times and their energy-dependent features are consistent with hiss wave scattering, while during active times, cap PADs are less significant especially at outer part of slot region, which could be due to the complex energizing and transport processes. Finally, the 90°-minimum PADs are persistently present in the inner belt and appear in the slot region during active times, and minima at 90° pitch angle are more significant for electrons with higher energies, which could be a critical evidence in identifying the underlying physical processes responsible for the formation of 90°-minimum PADs.
Passive zero-gravity leg restraint
A passive zero or microgravity leg restraint is described which includes a central support post with a top and a bottom. Extending from the central support post are a calf pad tab, to which calf pad is attached, and a foot pad tab, to which foot tab is attached. Also extending from central support post are knee pads. When the restraint is in use the user's legs are forced between pads by a user imposed scissors action of the legs. The user's body is then supported in a zero or microgravity neutral body posture by the leg restraint. The calf pad has semi-ridig elastic padding material covering structural stiffener. The foot pad has padding material and a structural stiffener. Knee pads have s structural tube stiffener at their core.
An Empirical Model of Radiation Belt Electron Pitch Angle Distributions Based On Van Allen Probes Measurements
Based on over 4 years of Van Allen Probes measurements, an empirical model of radiation belt electron equatorial pitch angle distribution (PAD) is constructed. The model, developed by fitting electron PADs with Legendre polynomials, provides the statistical PADs as a function of L-shell (L = 1-6), magnetic local time, electron energy (~30 keV to 5.2 MeV), and geomagnetic activity (represented by the Dst index) and is also the first empirical PAD model in the inner belt and slot region. For megaelectron volt electrons, model results show more significant day-night PAD asymmetry of electrons with higher energies and during disturbed times, which is caused by geomagnetic field configuration and flux radial gradient changes. Steeper PADs with higher fluxes around 90° pitch angle and lower fluxes at lower pitch angles for higher energy electrons and during active times are also present, which could be due to electromagnetic ion cyclotron wave scattering. For hundreds of kiloelectron volt electrons, cap PADs are generally present in the slot region during quiet times and their energy-dependent features are consistent with hiss wave scattering, while during active times, cap PADs are less significant especially at outer part of slot region, which could be due to the complex energizing and transport processes. The 90°-minimum PADs are persistently present in the inner belt and appear in the slot region during active times, and minima at 90° pitch angle are more significant for electrons with higher energies, which could be a critical evidence in identifying the underlying physical processes responsible for the formation of 90°-minimum PADs.
Association Between Prevalence of Peripheral Artery Disease and Radiation Exposure in the Atomic Bomb Survivors
Past reports suggested that total-body irradiation at 0.5 to 1.0 Gy could be responsible for atherosclerosis. Peripheral artery disease (PAD) is a manifestation of systematic atherosclerosis. Whether the consequences of a low-to-moderate dose of radiation include increased risk of PAD remains to be determined. The purpose of this study was to examine the association between radiation exposure and prevalence of PAD among Japanese atomic bomb survivors. Radiation exposure from the atomic bombing was assessed in 3476 participants (41.1% men, mean age 74.8 years with SD 6.4 years) with a cross-sectional survey in 2010 to 2014. Left- and right-side ankle-brachial indexes and upstroke time (UT) were obtained using oscillometric VP-2000. PAD was defined as an ankle-brachial index of 1.0 or less or a prior history related to revascularization. UT was considered a sensitive marker of early-stage PAD. Association between radiation exposure and PAD or UT was assessed using multivariable regression analyses with adjustment for potential confounding factors. Of 3476 participants, 79 (2.3%) were identified as having prevalent PAD. Multivariate logistic regression analysis indicated that radiation dose was unrelated to PAD prevalence (odds ratio, 0.83; 95% confidence interval [0.57-1.21]). UT appeared to increase with radiation dose, but the increase was not statistically significant (1.09 ms/Gy; 95% confidence interval [-0.17 to 2.36]). We found no clear association of radiation dose with PAD, but it remains to be determined whether UT is associated with radiation dose.
Microscale Effects from Global Hot Plasma Imagery
We have used a three-dimensional model of recovery phase storm hot plasmas to explore the signatures of pitch angle distributions (PADS) in global fast atom imagery of the magnetosphere. The model computes mass, energy, and position-dependent PADs based on drift effects, charge exchange losses, and Coulomb drag. The hot plasma PAD strongly influences both the storm current system carried by the hot plasma and its time evolution. In turn, the PAD is strongly influenced by plasma waves through pitch angle diffusion, a microscale effect. We report the first simulated neutral atom images that account for anisotropic PADs within the hot plasma. They exhibit spatial distribution features that correspond directly to the PADs along the lines of sight. We investigate the use of image brightness distributions along tangent-shell field lines to infer equatorial PADS. In tangent-shell regions with minimal spatial gradients, reasonably accurate PADs are inferred from simulated images. They demonstrate the importance of modeling PADs for image inversion and show that comparisons of models with real storm plasma images will reveal the global effects of these microscale processes.
Design of a Trigger Data Serializer ASIC for the Upgrade of the ATLAS Forward Muon Spectrometer
Not provided.
Chemical analysis of DC745 Materials: DEV Lot 1 reinvestigation; barcodes P053387, P053388, and P053389
This report serves as a follow up to our initial development lot 1 chemical analysis report (LA-UR-16-21970). The purpose of that report was to determine whether or not certain combinations of resin lots and curing agent lots resulted in chemical differences in the final material. One finding of that report suggested that pad P053389 was different from the three other pads analyzed. This report consists of chemical analysis of P053387, P053388, and a reinvestigation of P053389 all of which came from the potentially suspect combination of resin and curing agents lot. The goal of this report is to determine whether the observations relating to P053389 were isolated to that particular pad or systemic to that combination of resin and curing agent lot. The following suite of analyses were performed on the pads: Differential Scanning Calorimetry (DSC), Thermogravimetric Analysis (TGA), Fourier Transform Infrared Spectroscopy (FT-IR), and Solid State Nuclear Magnetic Resonance (NMR). The overall conclusions of the study are that pads P053387 and P053388 behave more consistently with the pads of other resin lot and curing agent lot combinations and that the chemical observations made regarding pad P053389 are isolated to that pad and not representative of an issue with that resin lot and curing agent lot combination.
Double-V block fingers with cruciform recess
In a robot having a gripper including a pair of fingers and a drive motor for driving the fingers toward and away from one another while the fingers remain parallel to each other, the fingers consist of finger pads, which interface with a handle on an object to be grasped, and a shank, which attaches the fingers to the robot gripper. The double-V finger has two orthogonal V-grooves forming in the center of the finger pads and recessed cruciform. The double-V finger is used with a handle on the object to be grasped which is the negative of the finger pads. The handle face consists of V-shaped pads capped with a rectangular cruciform. As the gripper is brought into place near the handle, the finger pads are lined up facing the handle pads. When the finger pad and the handle pad are in proper alignment, the rectangular ridges on the handle fall inside the rectangular grooves on the finger, and the grip is complete.
Cryogenic Storage Tank Non-Destructive Evaluation
This slide presentation reviews the work in non-destructive evaluation (NDE) of cryogenic storage tanks. Four large cryogenic tanks, constructed in 1965 with perlite insulation in the annular regions, are of concern. The construction of the tanks, two Liquid Oxygen (LOX) and two Liquid Hydrogen (LH2), are described. The loss rate for the LOX tank at Pad A is slightly higher than that for the one at Pad B. The concerns for the LH2 tank at Pad B are that there is a significantly higher boil-off rate than that at Pad A, that there is mold growth, indicative of increased heat flow, that there is a long down-time needed for repairs, and that 3 of 5 full thermal cycles have been used on the Pad B LH2 tank. The advantages and disadvantages of thermal imaging are given. A detailed description of what is visible of the structures in the infra-red is given and views of the thermal images are included. Missing Perlite is given as the probable cause of the cold spot on the Pad B LH2 tank. There is no indications of problematic cold regions on the Pad A LH2 tank, as shown by the thermal images given in the presentation. There is definite indication of a cold region on the Pad A LOX tank. There is however concerns with thermal imaging, as thermal images can be significantly effected by environmental conditions, image differences on similar days but with different wind speeds. Other effects that must be considered include ambient temperature, humidity levels/dew, and cloud reflections
Hail Disrometer Array for Launch Systems Support
Prior to launch, the space shuttle might be described as a very large thermos bottle containing substantial quantities of cryogenic fuels. Because thermal insulation is a critical design requirement, the external wall of the launch vehicle fuel tank is covered with an insulating foam layer. This foam is fragile and can be damaged by very minor impacts, such as that from small- to medium-size hail, which may go unnoticed. In May 1999, hail damage to the top of the External Tank (ET) of STS-96 required a rollback from the launch pad to the Vehicle Assembly Building (VAB) for repair of the insulating foam. Because of the potential for hail damage to the ET while exposed to the weather, a vigilant hail sentry system using impact transducers was developed as a hail damage warning system and to record and quantify hail events. The Kennedy Space Center (KSC) Hail Monitor System, a joint effort of the NASA and University Affiliated Spaceport Technology Development Contract (USTDC) Physics Labs, was first deployed for operational testing in the fall of 2006. Volunteers from the Community Collaborative Rain. Hail, and Snow Network (CoCoRaHS) in conjunction with Colorado State University were and continue to be active in testing duplicate hail monitor systems at sites in the hail prone high plains of Colorado. The KSC Hail Monitor System (HMS), consisting of three stations positioned approximately 500 ft from the launch pad and forming an approximate equilateral triangle (see Figure 1), was deployed to Pad 39B for support of STS-115. Two months later, the HMS was deployed to Pad 39A for support of STS-116. During support of STS-117 in late February 2007, an unusual hail event occurred in the immediate vicinity of the exposed space shuttle and launch pad. Hail data of this event was collected by the HMS and analyzed. Support of STS-118 revealed another important application of the hail monitor system. Ground Instrumentation personnel check the hail monitors daily when a vehicle is on the launch pad, with special attention after any storm suspected of containing hail. If no hail is recorded by the HMS, the vehicle and pad inspection team has no need to conduct a thorough inspection of the vehicle immediately following a storm. On the afternoon of July 13, 2007, hail on the ground was reported by observers at the VAB, about three miles west of Pad 39A, as well as at several other locations around Kennedy Space Center. The HMS showed no impact detections, indicating that the shuttle had not been damaged by any of the numerous hail events which occurred that day.