Affinity maturation of a portable Fab–RNA module for chaperone-assisted RNA crystallography

Antibody fragments such as Fabs possess properties that can enhance protein and RNA crystallization and therefore can facilitate macromolecular structure determination. In particular, Fab BL3–6 binds to an AAACA RNA pentaloop closed by a GC pair with ~100 nM affinity. The Fab and hairpin have served as a portable module for RNA crystallization. The potential for general application make it desirable to adjust the properties of this crystallization module in a manner that facilitates its use for RNA structure determination, such as ease of purification, surface entropy or binding affinity. In this work, we used both in vitro RNA selection and phage display selection to alter the epitope and paratope sides of the binding interface, respectively, for improved binding affinity. We identified a 5'-GNGACCC-3' consensus motif in the RNA and S97N mutation in complimentarity determining region L3 of the Fab that independently impart about an order of magnitude improvement in affinity, resulting from new hydrogen bonding interactions. Using a model RNA, these modifications facilitated crystallization under a wider range of conditions and improved diffraction. The improved features of the Fab–RNA module may facilitate its use as an affinity tag for RNA purification and imaging and as a chaperone for RNA crystallography.

59 BASIC BIOLOGICAL SCIENCES↗

Implementation of a Portable HPGe for Field Contamination Assay

In this work, using MCNP to construct a detector model based initially on x-ray images of a portable high purity germanium (HPGe) detector followed by normalizing covering material values to also agree with check source responses, a validation of the model was attained. By calibrating the detector parameters using large count spectra, rigorous reproducibility is attained for high activity measurements but does not prevent deviations from normality in error distributions at the very low count events where spectral peaks are not always identifiable. The resulting model was created to allow operational assay of contamination over large areal distributions that could not otherwise be measured, such as the exhaust shaft at the Waste Isolation Pilot Plant (WIPP). Results indicate that contamination levels of activity in the exhaust shaft can be assayed to within a factor of 2. Lastly, detection limits are evaluated to be well below the contamination levels, which would constitute a legal environmental release if unfiltered ventilation of the underground facility were used.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Portable laser-heating system for diamond anvil cells

The diamond anvil cell (DAC) technique coupled with laser heating has become the most successful method for studying materials in the multimegabar pressure range at high temperatures. However, so far all DAC laser-heating systems have been stationary: they are linked either to certain equipment or to a beamline. Here, a portable laser-heating system for DACs has been developed which can be moved between various analytical facilities, including transfer from in-house to a synchrotron or between synchrotron beamlines. Application of the system is demonstrated in an example of nuclear inelastic scattering measurements of ferropericlase (Mg{sub 0.88}Fe{sub 0.12})O and h.c.p.-Fe{sub 0.9}Ni{sub 0.1} alloy, and X-ray absorption near-edge spectroscopy of (Mg{sub 0.85}Fe{sub 0.15})SiO{sub 3} majorite at high pressures and temperatures. Our results indicate that sound velocities of h.c.p.-Fe{sub 0.9}Ni{sub 0.1} at pressures up to 50 GPa and high temperatures do not follow a linear relation with density.

43 PARTICLE ACCELERATORS↗

Understanding Performance Portability of Bioinformatics Applications in SYCL on an NVIDIA GPU

Our goal is to have a better understanding of performance portability of SYCL kernels on a GPU. Toward this goal, we migrate representative kernels in bioinformatics applications from CUDA to SYCL, evaluate their performance on an NVIDIA GPU, and explain the performance gaps through performance profiling and analyses. We hope that the findings provide valuable feedback to the development of the SYCL ecosystem.

Jin, Zheming↗

Kernels for scalable data analysis in science: Towards an architecture-portable future

In this paper, we pose and address some of the unique challenges in the analysis of scientific Big Data on supercomputing platforms. Our approach identifies, implements and scales numerical kernels that are critical to the instantiation of theory-inspired analytic workflows on modern computing architectures. We present the benefits of scalable kernels towards constructing algorithms such as principal component analysis and non-negative matrix factorization on an image-analysis use case at the Oak Ridge Leadership Computing Facility (OLCF). Based on experience with the use-case, we conclude that piecing scalable analytic kernels into user-defined analytic workflows are a flexible, modular and agile way to enable architecture-portable productivity for the data-intensive sciences.

Sukumar, Sreenivas R.↗

Design and development of a portable flash X-ray source driven by battery powered compact Marx generator

The design, construction and operational characteristics of a portable flash X-ray source driven by battery-powered compact Marx is reported. The novel configuration of compact Marx utilizes hollow capacitors in successive stages to enhance the erection reliability. The characteristic impedance of this system is ∼ 200 Ω. At discharge of ∼ 22 kV, >200 kV output pulse of 60 ns duration (FWHM) with rise time of <5 ns (10% - 90%) is produced. The pulser requires Nitrogen gas pressurization up to 3 atm for operation at maximum rating. The Marx generator assembly is fitted in to a stainless steel tube of 10 cm diameter and 1.2 m length. While using a demountable sealed X-ray tube of matched impedance, this device produces an X-ray pulse of approximately ∼ 30 ns duration and has maximum energy of ∼ 200 keV. This true tabletop device is able to produce dose up to 100 mR per shot, measured at the distance of 30 cm from output window. The focal spot size has been passively confirmed to be in the sub-millimeter (<1 mm) range. (author)

43 PARTICLE ACCELERATORS↗

Toward Abstracting the Communication Intent in Applications to Improve Portability and Productivity

Programming with communication libraries such as the Message Passing Interface (MPI) obscures the high-level intent of the communication in an application and makes static communication analysis difficult to do. Compilers are unaware of communication libraries' specifics, leading to the exclusion of communication patterns from any automated analysis and optimizations. To overcome this, communication patterns can be expressed at higher-levels of abstraction and incrementally added to existing MPI applications. In this paper, we propose the use of directives to clearly express the communication intent of an application in a way that is not specific to a given communication library. Our communication directives allow programmers to express communication among processes in a portable way, giving hints to the compiler on regions of computations that can be overlapped with communication and relaxing communication constraints on the ordering, completion and synchronization of the communication imposed by specific libraries such as MPI. The directives can then be translated by the compiler into message passing calls that efficiently implement the intended pattern and be targeted to multiple communication libraries. Thus far, we have used the directives to express point-to-point communication patterns in C, C++ and Fortran applications, and have translated them to MPI and SHMEM.

Mintz, Tiffany M.↗

Then and Now: Improving Software Portability, Productivity, and 100× Performance

The US Exascale Computing Project (ECP) has succeeded in preparing applications to run efficiently on the first reported Exascale supercomputers in the world. To achieve this, it modernized the whole leadership software stack, from libraries to simulation codes. In this article, we contrast selected leadership software before and after ECP. We discuss how sustainable research software development for leadership computing can embrace the conversation with the hardware vendors, the leadership computing facilities, the software community, and the domain scientists who are the application developers and integrators of software products. We elaborate on how software needs to take portability as a central design principle and to benefit from interdependent teams; we also demonstrate how moving to programming languages with high momentum, like modern C++, can help improve the sustainability, interoperability, and performance of research software. Finally, we showcase how cross-institutional efforts can enable algorithm advances that are beyond incremental performance optimization.

97 MATHEMATICS AND COMPUTING↗

Experiments to Quantify the Shielding Efficacy of Materials to be Implemented for Portable Shielding Enclosures that Adequately Mitigate EMI from Lighting Attachment Events

Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling” regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of ~33 kA and a risetime of 1.4 μs is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Least Squares Magnetic-Field Optimization for Portable Nuclear Magnetic Resonance Magnet Design

Single-sided and mobile nuclear magnetic resonance (NMR) sensors have the advantages of portability, low cost, and low power consumption compared to conventional high-field NMR and magnetic resonance imaging (MRI) systems. We present fast, flexible, and easy-to-implement target field algorithms for mobile NMR and MRI magnet design. The optimization finds a global optimum ina cost function that minimizes the error in the target magnetic field in the sense of least squares. When the technique is tested on a ring array of permanent-magnet elements, the solution matches the classical dipole Halbach solution. For a single-sided handheld NMR sensor, the algorithm yields a 640 G field homogeneous to 16 100 ppm across a 1.9 cc volume located 1.5 cm above the top of the magnets and homogeneous to 32 200 ppm over a 7.6 cc volume. This regime is adequate for MRI applications. We demonstrate that the homogeneous region can be continuously moved away from the sensor by rotating magnet rod elements, opening the way for NMR sensors with adjustable"sensitive volumes."

36 MATERIALS SCIENCE↗

PANDA-FES: Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science

Nuclear fusion is a potential source of carbon-free electricity with many concepts in development. The Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science (PANDA-FES) suite has been deployed since 2021 to measure neutron yield, energy, and spatiotemporal source location at two different Z-pinch fusion devices. This diagnostic can be used at a variety of facilities pursuing fusion in the magnetic, inertial, and magneto-inertial regimes. These different regimes have a wide range of time scales from less than 100 ns to a few μ s, neutron yields from 10 6 to 10 11 , and noise environments. Neutron yield is measured through activation of 79 Br and 89 Y with calibrated detectors. Temporal, spatial, and energy dependence of neutrons is measured with scintillators coupled to photomultiplier tubes (PMTs). Experimental setups and data analysis methods have been developed for these conditions. Finally, neutron yield, neutron energy anisotropy, and spatiotemporal evolution of the source have been measured.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

STEPS: A Portable Numerical Simulation Toolkit for Electrical Power System Dynamic Studies

Numerical simulation is the key technique for large scale power system analysis. Redistribution of global renewable power via international interconnections requires new simulation tools to study the interconnected systems with different nominal frequencies as a whole. In this paper we introduce an open source simulation toolkit for electrical power systems (STEPS) which is hosted at Github. Its kernel is coded in C++ with major functions of power flow and electro-mechanical dynamic simulation. Flexible options are provided and configurable to improve power flow solution and dynamic simulation. Common devices and models are supported in STEPS for AC/DC hybrid system studies. Studies of interconnected systems with different nominal frequencies is supported in STEPS for research of international interconnection. Application program interfaces are provided and wrapped with Python to enable high-level interfaces for general applications. STEPS is thread safe and parallel computation is supported in both kernel and script levels to accelerate simulation. It is portable and works on Windows and GNU/Linux platforms. Cases from small to large scale systems are thoroughly tested to validate the toolkit with commercial packages as benchmarks.

42 ENGINEERING↗

Portable total reflection x-ray fluorescence analysis in the identification of unknown laboratory hazards

In this study, a portable total reflection x-ray fluorescence (TXRF) spectrometer was used to analyze unknown laboratory hazards that precipitated on exterior surfaces of cooling pipes and fume hood pipes in chemical laboratories. With the aim to examine the accuracy of TXRF analysis for the determination of elemental composition, analytical results were compared with those of wavelength-dispersive x-ray fluorescence spectrometry, scanning electron microscope and energy-dispersive x-ray spectrometry, energy-dispersive x-ray fluorescence spectrometry, inductively coupled plasma atomic emission spectrometry, x-ray diffraction spectrometry (XRD), and x-ray photoelectron spectroscopy (XPS). Detailed comparison of data confirmed that the TXRF method itself was not sufficient to determine all the elements (Z > 11) contained in the samples. In addition, results suggest that XRD should be combined with XPS in order to accurately determine compound composition. This study demonstrates that at least two analytical methods should be used in order to analyze the composition of unknown real samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Localization and Quantification of Trace-gas Fugitive Emissions Using a Portable Optical Spectrometer

We present a portable optical spectrometer for fugitive emissions monitoring of methane (CH4). The sensor operation is based on tunable diode laser absorption spectroscopy (TDLAS), using a 5 cm open path design, and targets the 2ν3 R(4) CH4 transition at 6057.1 cm-1 (1651 nm) to avoid cross-talk with common interfering atmospheric constituents. Sensitivity analysis indicates a normalized precision of 2.0 ppmv∙Hz-1/2, corresponding to a noise-equivalent absorption (NEA) of 4.4×10-6 Hz-1/2 and minimum detectible absorption (MDA) coefficient of αmin = 8.8×10-7 cm-1∙Hz-1/2. Our TDLAS sensor is deployed at the Methane Emissions Technology Evaluation Center (METEC) at Colorado State University (CSU) for initial demonstration of single-sensor based source localization and quantification of CH4 fugitive emissions. The TDLAS sensor is concurrently deployed with a customized chemi-resistive metal-oxide (MOX) sensor for accuracy benchmarking, demonstrating good visual correlation of the concentration time-series. Initial angle-of-arrival (AOA) results will be shown, and development towards source magnitude estimation will be described.

03 NATURAL GAS↗

Spectra of clinical CT scanners using a portable Compton spectrometer

Purpose: Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x-ray spectra of CT scanners. Methods: In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x-ray fluorescence from the materials used. The spectrum of Compton scattered x-rays alters from the original source spectrum due to various physical processes. Reconstruction of the original x-ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved. This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x-ray tube. The Compton spectrometer is assessed in a clinical setting by measuring x-ray spectra at various tube voltages of three different medical CT scanner x-ray tubes. Results: The directly and indirectly measured spectra are in good agreement (their ratio being 0.99) thereby validating the reconstruction method. The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x-ray tube manufacturer. Conclusions: A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x-ray spectra of CT scanners. These measurements show that our compact Compton spectrometer can be rapidly set-up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.g., annual performance check-ups of CT scanners.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-P-46: Clinical Acceptance Testing and Implementation of a Portable CT Unit

Purpose: Planning for the first installation in New England of a new portable CT unit to be used in the Operating Room required the integration of many departments including Surgery, Neurosurgery, Information Services, Clinical Engineering, Radiology and Medical Physics/Radiation Safety. Acceptance testing and the quality assurance procedures were designed to optimize image quality and patient and personnel radiation exposure. Methods: The vendor’s protocols were tested using the CT Dosimetry phantoms. The system displayed the CTDIw instead of the CTDIvol while testing the unit. Radiation exposure was compared to existing CT scanners from installed CT units throughout the facility. Brainlab measures all 4 periphery slots on the CT Dosimetry phantom. The ACR measures only the superior slot for the periphery measurement. A comprehensive radiation survey was also performed for several locations. Results: The CTDIvol measurements were comparable for the following studies: brain, C-Spine, and sinuses. However, the mobile CT measurements were slightly higher than other CT units but within acceptable tolerance if measured using the ACR method.Based on scatter measurements, it was determined if any personnel were to stay in the OR Suite during image acquisition that the appropriate lead apron and thyroid shields had to be worn.In addition, to reduce unnecessary scatter, there were two mobile 6 foot wide shields (1/16″ lead equivalent) available to protect personnel in the room and adjacent areas. Conclusion: Intraoperative CT provides the physician new opportunities for evaluation of the progression of surgical resections and device placement at the cost of increasing the amount of trained personnel required to perform this procedure. It also brings with it challenges to keep the radiation exposure to the patients and staff within reasonable limits.

60 APPLIED LIFE SCIENCES↗

SU-E-T-221: Computational Evaluation of Proton Induced Gain in a Portable Faraday Cup

Purpose: The design of a new Portable Faraday Cup (PFC) used to calibrate proton accelerators was evaluated for energies between 50 and 220 MeV. Monte Carlo simulations performed in Geant4–10.0 were used to evaluate experimental results and reduce the relative detector error for this vacuum-less and low mass system, and invalidate current MCNP releases. Methods: The detector construction consisted of a copper conductor coated with an insulator and grounded with silver. Monte Carlo calculations in Geant4 were used to determine the net charge per proton input (gain) as a function of insulator thickness and beam energy. Kapton was chosen as the insulating material and was designed to capture backscattered electrons. Charge displacement from/into Kapton was assumed to follow a linear proportionality to the origin/terminus depth toward the outer ground layer. Kapton thicknesses ranged from 0 to 200 microns, proton energies were set to match empirical studies ranging from 70 to 250 MeV. Each setup was averaged over 1 million events using the FTFP-BERT 2.0 physics list. Results: With increasing proton energy, the gain of Cu+KA gradually converges to the limit of pure copper, with relative error between 1.52% and 0.72%. The Ag layer created a more diverging behavior, accelerating the flux of negative charge into the device and increasing relative error when compared to pure copper from 1.21% to 1.63%. Conclusion: Gain vs. beam energy signatures were acquired for each device. Further analysis reveals proportionality between insulator thickness and measured gain, albeit an inverse proportionality between beam energy and in-flux of electrons. Increased silver grounding layer thickness also decreases gain, though the relative error expands with beam energy, contrary to the Kapton layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Embedded ensemble propagation for improving performance, portability, and scalability of uncertainty quantification on emerging computational architectures

In this study, quantifying simulation uncertainties is a critical component of rigorous predictive simulation. A key component of this is forward propagation of uncertainties in simulation input data to output quantities of interest. Typical approaches involve repeated sampling of the simulation over the uncertain input data, and can require numerous samples when accurately propagating uncertainties from large numbers of sources. Often simulation processes from sample to sample are similar and much of the data generated from each sample evaluation could be reused. We explore a new method for implementing sampling methods that simultaneously propagates groups of samples together in an embedded fashion, which we call embedded ensemble propagation. We show how this approach takes advantage of properties of modern computer architectures to improve performance by enabling reuse between samples, reducing memory bandwidth requirements, improving memory access patterns, improving opportunities for fine-grained parallelization, and reducing communication costs. We describe a software technique for implementing embedded ensemble propagation based on the use of C++ templates and describe its integration with various scientific computing libraries within Trilinos. We demonstrate improved performance, portability and scalability for the approach applied to the simulation of partial differential equations on a variety of CPU, GPU, and accelerator architectures, including up to 131,072 cores on a Cray XK7 (Titan).

97 MATHEMATICS AND COMPUTING↗