Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Quasiclassical asymptotics and coherent states for bounded discrete spectra

We consider discrete spectra of bound states for nonrelativistic motion in attractive potentials V{sub {sigma}}(x)=-|V{sub 0}| |x|{sup -}{sigma}, 0<{sigma}{<=}2. For these potentials the quasiclassical approximation for n{yields}{infinity} predicts quantized energy levels e{sub {sigma}}(n) of a bounded spectrum varying as e{sub {sigma}}(n){approx}-n{sup -}2{sigma}/(2-{sigma}). We construct collective quantum states using the set of wavefunctions of the discrete spectrum assuming this asymptotic behavior. We give examples of states that are normalizable and satisfy the resolution of unity, using explicit positive functions. These are coherent states in the sense of Klauder and their completeness is achieved via exact solutions of Hausdorff moment problems, obtained by combining Laplace and Mellin transform methods. For {sigma} in the range 0 < {sigma}{<=} 2/3 we present exact implementations of such states for the parametrization {sigma}= 2(k-l)/(3k-l) with k and l positive integers satisfying k>l.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Construction of photon-added spin coherent states and their statistical properties

In the present work, we construct and investigate some properties of the photon-added spin coherent states (PA-SCSs). The Klauder’s minimal set of conditions required to obtain coherent states are discussed. We give the analytical form for the positive weight function in the resolution of unity. Finally, we examine the statistical properties of the PA-SCSs in terms of different parameters using the Mandel’s Q-parameter. All these quantities are expressed in terms of hypergeometric and Meijer G-functions, and so, the PA-SCSs are a new field of application for these functions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-destructive depth-resolved characterization of residual strain fields in high electron mobility transistors using differential aperture x-ray microscopy

Localized residual stress and elastic strain concentrations in microelectronic devices often affect the electronic performance, resistance to thermomechanical damage, and, likely, radiation tolerance. A primary challenge for the characterization of these concentrations is that they exist over sub-μm length-scales, precluding their characterization by more traditional residual stress measurement techniques. Here, in this study, we demonstrate the use of synchrotron x-ray-based differential aperture x-ray microscopy (DAXM) as a viable, non-destructive means to characterize these stress and strain concentrations in a depth-resolved manner. DAXM is used to map two-dimensional strain fields between the source and the drain in a gallium nitride (GaN) layer within high electron mobility transistors (HEMTs) with sub-μm spatial resolution. Strain fields at various positions in both pristine and irradiated HEMT specimens are presented in addition to a preliminary stress analysis to estimate the distribution of various stress components within the GaN layer. γ-irradiation is found to significantly reduce the lattice plane spacing in the GaN along the sample normal direction, which is attributed to radiation damage in transistor components bonded to the GaN during irradiation.

42 ENGINEERING↗

Design and Implementation of Distributed Ultra-High Temperature Sensing System With a Single Crystal Fiber

Modern high-temperature processes, such as fossil energy production, nuclear reactors, and chemical reactors lack robust, distributed sensing systems to map temperatures in these high-value harsh-environment systems. Regular silica-fiber-based distributed temperature sensing systems usually only operate at temperatures below about 800 °C. In this paper, we present the design, implementation, and testing of a distributed ultra-high temperature sensing system using Raman scattering intensity, which operates from room temperature to above 1400 °C. Consideration is given to the impacts of thermal radiation, fluorescence, and the multimode nature of unclad single-crystal fiber to optimize the system. Results from picosecond and sub-nanosecond lasers were compared. Measurements were taken with a ~2 m sapphire optical fiber, which represents the longest commercially available length. Here, a spatial resolution of 12.4 cm and position standard deviation of 0.28 mm were achieved up to the maximum testing temperature of 1400 °C, which is a new record for distributed temperature sensing systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploitation of Geometric Occlusion and Covariance Spectroscopy in a Gamma Sensor Array

The National Security Technologies, LLC, Remote Sensing Laboratory has recently used an array of six small-footprint (1-inch diameter by 3-inch long) cylindrical crystals of thallium-doped sodium iodide scintillators to obtain angular information from discrete gamma ray–emitting point sources. Obtaining angular information in a near-field measurement for a field-deployed gamma sensor is a requirement for radiological emergency work. Three of the sensors sit at the vertices of a 2-inch isosceles triangle, while the other three sit on the circumference of a 3-inch-radius circle centered in this triangle. This configuration exploits occlusion of sensors, correlation from Compton scattering within a detector array, and covariance spectroscopy, a spectral coincidence technique. Careful placement and orientation of individual detectors with reference to other detectors in an array can provide improved angular resolution for determining the source position by occlusion mechanism. By evaluating the values of, and the uncertainties in, the photopeak areas, efficiencies, branching ratio, peak area correction factors, and the correlations between these quantities, one can determine the precise activity of a particular radioisotope from a mixture of radioisotopes that have overlapping photopeaks that are ordinarily hard to deconvolve. The spectral coincidence technique, often known as covariance spectroscopy, examines the correlations and fluctuations in data that contain valuable information about radiation sources, transport media, and detection systems. Covariance spectroscopy enhances radionuclide identification techniques, provides directional information, and makes weaker gamma-ray emission—normally undetectable by common spectroscopic analysis—detectable. A series of experimental results using the concept of covariance spectroscopy are presented.

occlusion, covariance spectroscopy, correlations, ↗

Operation of GRETINA at NSCL

This proposal funded the continued operation of the Gamma-ray Energy tracking Array GRETINA as a user device at the National Superconducting Cyclotron Laboratory (NSCL) at Michigan State University. This was a continuation and covered the operation from January 1, 2017 to December 31, 2017. Twenty-three experiments were completed with GRETINA at NSCL. GRETINA was installed at the reaction target position of the high-resolution, large-acceptance S800 spectrograph and the program started on October 15, 2017. The campaign capitalized on the opportunities provided by NSCL’s energetic rare isotope beams produced by projectile fragmentation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hygroscopicity Evaluation of Halide Scintillators

A collaborative study of relative hygroscopicity of anhydrous halide scintillators grown at various laboratories is presented. We have developed a technique to evaluate moisture sensitivity of both raw materials and grown crystals, in which the moisture absorption rate is measured using a gravimetric analysis. Degradation of the scintillation performance was investigated by recording gamma-ray spectra and monitoring the photopeak position, count rate and energy resolution. The accompanying physical degradation of the samples exposed to ambient atmosphere was photographically recorded as well. The results were compared with ben

Zhuravleva, M↗

Dynamic Rotor Deformation and Vibration Monitoring Using a Non-Incremental Laser Doppler Distance Sensor

Monitoring rotor deformations and vibrations dynamically is an important task for improving the safety and the lifetime as well as the energy efficiency of motors and turbo machines. However, due to the high rotor speed encountered in particular at turbo machines, this requires concurrently a high measurement rate and high accuracy, which can not be fulfilled by most commercially available sensors. To solve this problem, we developed a non-incremental laser Doppler distance sensor (LDDS), which is able to measure simultaneously the in-plane velocity and the out-of-plane position of moving rough solid objects with micrometer precision. In addition, this sensor concurrently offers a high temporal resolution in the microsecond range, because its position uncertainty is in principle independent of the object velocity in contrast to conventional distance sensors, which is a unique feature of the LDDS. Consequently, this novel sensor enables precise and dynamic in-process deformation and vibration measurements on rotating objects, such as turbo machine rotors, even at very high speed. In order to evidence the capability of the LDDS, measurements of rotor deformations (radial expansion), vibrations and wobbling motions are presented at up to 50,000 rpm rotor speed.

42 ENGINEERING↗

Micro-Hall position sensing of magnetic nanowires.

The Hall voltage output of a micro-Hall magnetic sensor depends on the relative position of a magnetic nanowire with respect to its sensing area. Following this idea, we performed analytical calculations which show that, under certain conditions, these devices can track the position of a magnetic nanowire with subnanometer resolution. Our results suggest that micro-Hall sensors can be utilized to provide a direct electronic readout of the position of magnetic nanowires in their applications as biomolecular manipulators or dynamic components in micro- and nanoscale devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HIGH-RESOLUTION IMAGES OF ORBITAL MOTION IN THE ORION TRAPEZIUM CLUSTER WITH THE LBT AO SYSTEM

The new 8.4 m LBT adaptive secondary AO system, with its novel pyramid wavefront sensor, was used to produce very high Strehl ({approx}> 75% at 2.16 {mu}m) near-infrared narrowband (Br{gamma}: 2.16 {mu}m and [Fe II]: 1.64 {mu}m) images of 47 young ({approx}1 Myr) Orion Trapezium {theta}{sup 1} Ori cluster members. The inner {approx}41 Multiplication-Sign 53'' of the cluster was imaged at spatial resolutions of {approx}0.''050 (at 1.64 {mu}m). A combination of high spatial resolution and high S/N yielded relative binary positions to {approx}0.5 mas accuracies. Including previous speckle data, we analyze a 15 year baseline of high-resolution observations of this cluster. We are now sensitive to relative proper motions of just {approx}0.3 mas yr{sup -1} (0.6 km s{sup -1} at 450 pc); this is a {approx}7 Multiplication-Sign improvement in orbital velocity accuracy compared to previous efforts. We now detect clear orbital motions in the {theta}{sup 1} Ori B{sub 2} B{sub 3} system of 4.9 {+-} 0.3 km s{sup -1} and 7.2 {+-} 0.8 km s{sup -1} in the {theta}{sup 1} Ori A{sub 1} A{sub 2} system (with correlations of P.A. versus time at >99% confidence). All five members of the {theta}{sup 1} Ori B system appear likely a gravitationally bound 'mini-cluster'. The very lowest mass member of the {theta}{sup 1} Ori B system (B{sub 4}; mass {approx}0.2 M{sub Sun }) has, for the first time, a clearly detected motion (at 4.3 {+-} 2.0 km s{sup -1}; correlation = 99.7%) w.r.t. B{sub 1}. However, B{sub 4} is most likely in a long-term unstable (non-hierarchical) orbit and may 'soon' be ejected from this 'mini-cluster'. This 'ejection' process could play a major role in the formation of low-mass stars and brown dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

Structures of the Ribosome in Intermediate States of Ratcheting

Protein biosynthesis on the ribosome requires repeated cycles of ratcheting, which couples rotation of the two ribosomal subunits with respect to each other, and swiveling of the head domain of the small subunit. However, the molecular basis for how the two ribosomal subunits rearrange contacts with each other during ratcheting while remaining stably associated is not known. Here, we describe x-ray crystal structures of the intact Escherichia coli ribosome, either in the apo-form (3.5 angstrom resolution) or with one (4.0 angstrom resolution) or two (4.0 angstrom resolution) anticodon stem-loop tRNA mimics bound, that reveal intermediate states of intersubunit rotation. In the structures, the interface between the small and large ribosomal subunits rearranges in discrete steps along the ratcheting pathway. Positioning of the head domain of the small subunit is controlled by interactions with the large subunit and with the tRNA bound in the peptidyl-tRNA site. The intermediates observed here provide insight into how tRNAs move into the hybrid state of binding that precedes the final steps of mRNA and tRNA translocation.

36 MATERIALS SCIENCE↗

Beam Position Monitor System for PEP II

We describe the beam position monitor system built for PEP-II, the B-factory at SLAC. The system reports beam position for bunches of between 5 x 10{sup 8} and 8 x 10{sup 10} electron charges, either singly or as continuous streams of bunches every 4.2 ns. Resolution at full charge is to be better than 10 microns in a single turn. Higher resolution is available via on-board multi-turn averaging. The position signal is processed in a 20 MHz bandwidth around 952 MHz. This bandwidth, rather broader than that typical of RF position monitors, allows good resolution for low charge single bunches. Additional novel features include stringent control of return losses in order to minimize cross-talk between nearby bunches which may contain very different charges. The digitizing electronics is multiplexed between the two PEP-II storage rings. Design, construction, and installation experience, as well as first results with beam are presented.

43 PARTICLE ACCELERATORS↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 {mu}m spot of {approx}5x10{sup 9} photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 {mu}m are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution ({approx}0.2 {mu}m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10{sup -5} strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution ({approx}150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal Structures of Substrate-Bound And Substrate-Free Cytochrome P450 46A1, the Principal Cholesterol Hydroxylase in the Brain

By converting cholesterol to 24S-hydroxycholesterol, cytochrome P450 46A1 (CYP46A1) initiates the major pathway for cholesterol removal from the brain. Two crystal structures of CYP46A1 were determined. First is the 1.9-{angstrom} structure of CYP46A1 complexed with a high-affinity substrate cholesterol 3-sulfate (CH-3S). The second structure is that of the substrate-free CYP46A1 at 2.4-{angstrom} resolution. CH-3S is bound in the productive orientation and occupies the entire length of the banana-shaped hydrophobic active-site cavity. A unique helix B{prime}-C loop insertion (residues 116-120) contributes to positioning cholesterol for oxygenation catalyzed by CYP46A1. A comparison with the substrate-free structure reveals substantial substrate-induced conformational changes in CYP46A1 and suggests that structurally distinct compounds could bind in the enzyme active site. In vitro assays were performed to characterize the effect of different therapeutic agents on cholesterol hydroxylase activity of purified full-length recombinant CYP46A1, and several strong inhibitors and modest coactivators of CYP46A1 were identified. Structural and biochemical data provide evidence that CYP46A1 activity could be altered by exposure to some therapeutic drugs and potentially other xenobiotics.

36 MATERIALS SCIENCE↗

Rapid additive manufacturing of MR compatible multipinhole collimators with selective laser melting of tungsten powder

Purpose: The construction of complex collimators with a high number of oblique pinholes is very labor intensive, expensive or is sometimes impossible with the current available techniques (drilling, milling or electric discharge machining). All these techniques are subtractive: one starts from solid plates and the material at the position of the pinholes is removed. The authors used a novel technique for collimator construction, called metal additive manufacturing. This process starts with a solid piece of tungsten on which a first layer of tungsten powder is melted. Each subsequent layer is then melted on the previous layer. This melting is done by selective laser melting at the locations where the CAD design file defines solid material. Methods: A complex collimator with 20 loftholes with 500 {mu}m diameter pinhole opening was designed and produced (16 mm thick and 70 Multiplication-Sign 52 mm{sup 2} transverse size). The density was determined, the production accuracy was measured (GOM ATOS II Triple Scan, Nikon AZ100M microscope, Olympus IMT200 microscope). Point source measurements were done by mounting the collimator on a SPECT detector. Because there is increasing interest in dual-modality SPECT-MR imaging, the collimator was also positioned in a 7T MRI scanner (Bruker Pharmascan). A uniform phantom was acquired using T1, T2, and T2* sequences to check for artifacts or distortion of the phantom images due to the collimator presence. Additionally, three tungsten sample pieces (250, 500, and 750 {mu}m thick) were produced. The density, attenuation (140 keV beam), and uniformity (GE eXplore Locus SP micro-CT) of these samples were measured. Results: The density of the collimator was equal to 17.31 {+-} 0.10 g/cm{sup 3} (89.92% of pure tungsten). The production accuracy ranges from -260 to +650 {mu}m. The aperture positions have a mean deviation of 5 {mu}m, the maximum deviation was 174 {mu}m and the minimum deviation was -122 {mu}m. The mean aperture diameter is 464 {+-} 19 {mu}m. The calculated and measured sensitivity and resolution of point sources at different positions in the field-of-view agree well. The measured and expected attenuation of the three sample pieces are in a good agreement. There was no influence of the 7T magnetic field on the collimator (which is paramagnetic) and minimal distortion was noticed on the MR scan of the uniform phantom. Conclusions: Additive manufacturing is a very promising technique for the production of complex multipinhole collimators and may also be used for producing other complex collimators. The cost of this technique is only related to the amount of powder needed and the time it takes to have the collimator built. The timeframe from design to collimator production is significantly reduced.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-resolution measurement of absolute {alpha}-decay widths in {sup 16}O

By using a large-acceptance position-sensitive silicon detector array in coincidence with the high-resolution Munich Q3D spectrograph, unambiguous measurements have been made of the absolute {alpha}-particle decay widths from excited states in {sup 16}O* in the energy range 13.85 to 15.87 MeV. Carbon targets have been bombarded with 42-MeV {sup 6}Li beams to induce {sub 6}{sup 12}C({sub 3}{sup 6}Li, d){sub 8}{sup 16}O* reactions. The deuteron ejectiles were measured in the Q3D and the results gated by {sup 4}He+{sup 12}C breakup products detected in the silicon array, the efficiency of which was modeled using Monte Carlo simulations. By comparing total population and breakup-gated spectra, the following absolute {alpha}-decay widths have been measured with high resolution: {Gamma}{sub {alpha}}0/{Gamma}{sub tot} = 0.87{+-}0.11 (13.980 MeV), 1.04{+-}0.15 (14.302 MeV), 0.92{+-}0.10 (14.399 MeV), 0.59{+-}0.04 (14.815 MeV), 0.88{+-}0.18 (15.785 MeV), and {Gamma}{sub {alpha}}1/{Gamma}{sub tot}=1.14{+-}0.08 (14.660 MeV), 0.46{+-}0.06 (14.815 MeV).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solar position confounds the relationship between ecosystem function and vegetation indices derived from solar and photosynthetically active radiation fluxes

Vegetation indices derived from solar and photosynthetically active radiation (PAR) sensors (i.e. radiation derived) have been under-utilized in inferring ecosystem function, despite measurement capability at hundreds of sites. This under-utilization may be attributed to reported mismatches among the seasonality of radiation- and satellite-derived vegetation indices and canopy photosynthesis; herein referred to as measurement biases. In this work, biases in radiation derived reflectance and vegetation indices were assessed using a decadal record of satellite and ground based spectroradiometer data, ecosystem phenology and CO 2 fluxes, and radiation derived vegetation indices (i.e. the Normalized Difference Vegetation Index [NDVI], the two band Enhanced Vegetation Index [EVI2]) from a high latitude tundra site (i.e. Imnaviat). At Imnaviat, we found poor correspondence between the three types of reflectance and vegetation indices, especially during the latter part of the growing season. Radiation derived vegetation indices resulted in incorrect estimates of phenological timing of up to a month and poor relationships with canopy photosynthesis (i.e. Gross Ecosystem Exchange (GEE)). These mismatches were attributed to solar position (i.e. solar zenith and azimuth angle) and a method, based on the diel visible and near-infrared albedo variation, was developed to improve the performance of the vegetation indices. The ability of radiation derived vegetation indices to infer GEE and phenological dates drastically improved once radiation derived vegetation indices were corrected for solar position associated biases at Imnaviat. Moreover, radiation derived vegetation indices became better aligned with MODerate resolution Imaging Spectroradiometer (MODIS) satellite estimates after solar position associated biases were corrected at Imnaviat and at 25 Fluxnet sites (~90 site years) across North America. Corrections developed here provide a way forward in understanding daily ecosystem function or filling large gaps in eddy covariance data at a significant number of Fluxnet sites.

54 ENVIRONMENTAL SCIENCES↗

SU-C-207A-02: Proton Radiography Using Pencil Beam Scanning and a Novel, Low-Cost Range Telescope

Purpose: While the energy of therapeutic proton beams can be adjusted to penetrate to any given depth in water, range uncertainties arise in patients due in part to imprecise knowledge of the stopping power of protons in human tissues [1]. Proton radiography is one approach to reduce the beam range uncertainty [2], thereby allowing for a reduction in treatment margins and dose escalation. Methods: The authors have adapted a novel detector technology based on Micromesh Gaseous Structure (“Micromegas”) for proton therapy beams and have demonstrated fine spatial and time resolution of magnetically scanned proton pencil beams, as well as wide dynamic range for dosimetry [3]. The authors have constructed a prototype imaging system comprised of 5 Micromegas layers. Proton radiographs were obtained downstream of solid water assemblies. The position-sensitive monitor chambers in the IBA proton delivery nozzle provide the beam entrance position. Results: Our technique achieves spatial resolution as low as 300 µm and water-equivalent thickness (WET) resolution as good as 0.02% (60 µm out of 31 cm total thickness). The dose delivered to the patient is kept below 2 cGy. The spatial resolution as a function of sample rate and number of delivered protons is found to be near the theoretical Cramer-Rao lower bound. By extrapolating the CR bound, we argue that the imaging dose could be further lowered to 1 mGy, while still achieving submillimeter spatial resolution, by achievable instrumentation and beam delivery modifications. Conclusion: For proton radiography, high spatial and WET resolution can be achieved, with minimal additional dose to patient, by using magnetically scanned proton pencil beams and Micromegas detectors.

60 APPLIED LIFE SCIENCES↗