Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Synchrophasor-Based Zonal Current Differential Protection for Secondary Low Voltage Networks

This report describes an approach to utilizing phasor measurement unit (PMU) data from multiple Intelligent Electronics Devices (IEDs) in a low-voltage network to produce a differential scheme for protecting the medium-voltage feeder and low-voltage network transformers. The proposed protection scheme is designed and prototyped on a real-time automation controller. Its performance is evaluated using real-time controller hardware-in-the-loop simulation. Lab testing results indicate that the proposed protection scheme allows significant distributed energy resources (DER) backfeed and enables selective and fast protection of medium voltage feeders.

42 ENGINEERING↗

Leveraging PMU for Protection and Control

This presentation discusses the application of synchronized measurement in transmission system protection. The proposed wide area system protection (WASP) scheme uses PMU data to perform zonal current differential protection for the whole transmission system with high IBR penetration. This novel protection concept uses synchronized measurement, which is one of the key tasks proposed in the award DE-EE0010655.

14 SOLAR ENERGY↗

Utility Experience with Inverter-Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. This report identifies various protection challenges due to IBRs that industry is facing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY24 – FY25 Efforts to Revive the ANS-54.8 Liquid Metal Fire Protection in LMR Plants Standard

The current multi-year effort seeks to utilize national laboratory support from Argonne to expedite revival of the ANS-54.8 standard titled “Liquid Metal Fire Protection in LMR Plants.” To achieve that objective, the following tasks were identified: Task 1 involves working directly with ANS to revive the ANS-54.8 Working Group. This was to be accomplished by completing necessary paperwork, submitting that paperwork to ANS for approval, enlisting potential working group members from industry, the NRC, national laboratories, and universities, and organizing and leading Working Group activities. The overall purpose of the Working Group is to develop an updated draft of ANS-54.8 for review and approval by ANS consensus committees, the ANS Standards Board, and certification from ANSI. Task 2 focuses on leveraging historical information and expertise at Argonne related to sodium fire protection systems and strategies. For more than a decade, Argonne has worked on both international and domestic projects related to sodium fire protection system development and evaluation. The goal of this task is to utilize that experience to help inform the ANS-54.8 Working Group on important considerations that may be addressed in an updated draft of ANS-54.8. Task 3 focuses on leveraging Argonne experience in the development of and use of analysis methods and tools for the simulation of sodium fire scenarios and evaluation of the effectiveness of sodium fire protection systems and strategies. For more than a decade, Argonne has recovered, modified, and utilized several historical sodium fire analysis software tools. The goal of this task is to utilize that experience to help inform the ANS-54.8 Working Group of best practices for sodium fire progression analysis that may be addressed in an updated draft of ANS-54.8.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Final report and documentation for the security enabled programmable switch for protection of distributed internetworked computers LDRD.

An increasing number of corporate security policies make it desirable to push security closer to the desktop. It is not practical or feasible to place security and monitoring software on all computing devices (e.g. printers, personal digital assistants, copy machines, legacy hardware). We have begun to prototype a hardware and software architecture that will enforce security policies by pushing security functions closer to the end user, whether in the office or home, without interfering with users' desktop environments. We are developing a specialized programmable Ethernet network switch to achieve this. Embodied in this device is the ability to detect and mitigate network attacks that would otherwise disable or compromise the end user's computing nodes. We call this device a 'Secure Programmable Switch' (SPS). The SPS is designed with the ability to be securely reprogrammed in real time to counter rapidly evolving threats such as fast moving worms, etc. This ability to remotely update the functionality of the SPS protection device is cryptographically protected from subversion. With this concept, the user cannot turn off or fail to update virus scanning and personal firewall filtering in the SPS device as he/she could if implemented on the end host. The SPS concept also provides protection to simple/dumb devices such as printers, scanners, legacy hardware, etc. This report also describes the development of a cryptographically protected processor and its internal architecture in which the SPS device is implemented. This processor executes code correctly even if an adversary holds the processor. The processor guarantees both the integrity and the confidentiality of the code: the adversary cannot determine the sequence of instructions, nor can the adversary change the instruction sequence in a goal-oriented way.

99 GENERAL AND MISCELLANEOUS↗

Nanolipoprotein particle (NLP) vaccine confers protection against Yersinia pestis aerosol challenge in a BALB/c mouse model

Introduction: Yersinia pestis is the etiological agent of plague, a disease that remains a concern as demonstrated by recent outbreaks in Madagascar. Infection with Y. pestis results in a rapidly progressing illness that can only be successfully treated with antibiotics given shortly after symptom onset. Live attenuated or whole cell inactivated vaccines confer protection against bubonic plague, but pneumonic plague has been more difficult to prevent. Novel effective subunit vaccine formulations may circumvent some of these shortfalls. Here, we compare the immunogenicity generated by an advanced subunit vaccine (F1V fusion protein) and a nanolipoprotein particle (NLP)-based vaccine. Methods: The NLP, a high-density lipoprotein mimetic, provides a nanoscale delivery platform for recombinant Y. pestis antigens LcrV (V) and F1. BALB/c mice were immunized via subcutaneous injection twice, three or four weeks apart. Four weeks later, splenocytes and sera were collected for immune profiling, and mice were challenged with aerosolized Y. pestis CO92. Results: Both formulations induced a strong IgG response against the F1 and V proteins, along with a robust memory B cell response and a balanced cell-mediated immune response as evidenced by both Th1- and Th2-related cytokines. The NLP-based vaccine induced a stronger cytokine response against F1, V, and F1V proteins relative to the F1V vaccine. As with F1V, the inclusion of Alhydrogel (Alu) in NLP vaccine formulations was critical for enhanced immunogenicity and protective efficacy. Mice that received two doses of F1:V:NLP + Alu and CpG were completely protected from a challenge with approximately eight median lethal doses of aerosolized Y. pestis CO92 and this protection confirmed the well-documented synergy between the F1 and V antigens in context of pneumonic plague. The NLPs have defined regions of polarity that facilitates the incorporation of a wide range of adjuvants and antigens with distinct physicochemical properties and are an excellent candidate platform for the development of multi-antigen vaccines.

F1↗

An mRNA vaccine encoding the Ebola virus glycoprotein induces high neutralizing antibody titers and provides strong protection against lethal infections in mouse models

Ebola virus (EBOV) is the causative agent of Ebola disease (EBOD), a viral hemorrhagic fever with a notably high case fatality rate. Current treatments for EBOD are limited to monoclonal antibodies or two licensed viral vector vaccines, a recombinant vesicular stomatitis virus (rVSV)-vectored vaccine or an adenovirus and modified vaccinia Ankara regimen. However, comparisons of protection, efficacy, and durability with alternative nucleotide platforms remain understudied. Here, we evaluated the immunogenicity of an mRNA vaccine expressing the EBOV glycoprotein (GP) in parallel with rVSV- and DNA-based vaccine platforms. The mRNA EBOV-GP vaccine, formulated in lipid nanoparticles, elicited significantly higher levels of total IgG and neutralizing antibody titers compared to the rVSV-EBOV-GP vaccine. Linear antibody epitope analysis indicated a preference for targeting the mucin-like domain in EBOV-GP1 following rVSV-based vaccination, while the mRNA platform distinctly targeted the internal fusion loop of EBOV-GP2. After characterizing the immunogenicity of the mRNA vaccine, two models of EBOD were used to demonstrate its protective efficacy: a surrogate rVSV-based challenge model of EBOD using type-I interferon deficient C57BL/6 mice and infection of BALB/c mice with authentic mouse-adapted EBOV. In both studies, the EBOV mRNA vaccine fully protected the mouse cohorts against morbidity and mortality. Additionally, the EBOV mRNA vaccine produced greater neutralizing antibody titers compared to the DNA EBOV-GP vaccine. These results suggest that an mRNA vaccine expressing EBOV-GP can induce robust, functional humoral responses that are protective against EBOD, warranting further development as an alternative to, or as part of a vaccine strategy including, viral vectored vaccines.

DNA vaccines↗

African Swine Fever Vaccine Candidate ASFV-G-ΔI177L Produced in the Swine Macrophage-Derived Cell Line IPKM Remains Genetically Stable and Protective against Homologous Virulent Challenge

ASFV vaccine candidate ASFV-G-ΔI177L has been shown to be highly efficacious in inducing protection against challenges with the parental virus, the Georgia 2010 isolate, as well as against field strains isolated from Vietnam. ASFV-G-ΔI177L has been shown to produce protection even when used at low doses (10 2 HAD 50 ) and shows no residual virulence even when administered at high doses (10 6 HAD 50 ) or evaluated for a relatively long period of time (6 months). ASFV-G-ΔI177L stocks can only be massively produced in primary cell macrophages. Alternatively, its modified version (ASFV-G-ΔI177L/ΔLVR) grows in a swine-derived cell line (PIPEC), acquiring significant genomic modifications. We present here the development of ASFV-G-ΔI177L stocks in a swine macrophage cell line, IPKM, and its protective efficacy when evaluated in domestic pigs. Successive passing of ASFV-G-ΔI177L in IPKM cells produces minimal genomic changes. Interestingly, a stock of ASFV-G-ΔI177L obtained after 10 passages (ASFV-G-ΔI177Lp10) in IPKM cells showed very small genomic changes when compared with the original virus stock. ASFV-G-ΔI177Lp10 conserves similar growth kinetics in primary swine macrophage cultures than the original parental virus ASFV-G-ΔI177L. Pigs infected with 10 3 HAD 50 of ASFV-G-ΔI177Lp10 developed a strong virus-specific antibody response and were completely protected against the challenge with the parental virulent field isolate Georgia 2010. Therefore, IPKM cells could be an effective alternative for the production of ASFV vaccine stocks for those vaccine candidates exclusively growing in swine macrophages.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of the Reversion to Virulence and Protective Efficacy in Pigs Receiving the Live Attenuated Classical Swine Fever Recombinant Vaccine Candidate FlagT4G

Background/Objectives: Control of classical swine fever virus (CSFV) in endemic countries relies on vaccination using live attenuated vaccines (LAVs). Most of these LAVs do not allow for the differentiation of vaccinated animals from infected animals (DIVA) based on their serological response. FlagT4G vaccine is a novel candidate that confers robust protective immunity early after vaccination and shows DIVA capabilities. Methods: This report presents the characterization of FlagT4G virus in terms of the stability of its genomic and attenuated phenotypes assessed by a reversion to virulence protocol, as well as its protective efficacy by determining the minimal protective dose. Results: Results presented here demonstrate that after five consecutive passages in groups of 5-week-old susceptible domestic pigs, FlagT4G virus remains genetically stable, and its attenuated phenotype remains unaltered. In terms of efficacy, FlagT4G virus induced solid protection against the intranasal challenge with 105 tissue culture infectious dose (TCID50) of virulent field isolate Brescia virus, even with a vaccine dose as low as 102 TCID50. Conclusions: Results presented here indicate that the FlagT4G vaccine may be a useful tool for CSFV control.

Immunology↗

Protection of Hardware: Powering Systems (Power Converter, Normal Conducting, and Superconducting Magnets)

Along with the protection of magnets and power converters, we have added a section on personnel protection because this is our highest priority in the design and operation of power systems. Thus, our topics are the protection of people, power converters, and magnet loads (protected from the powering equipment), including normal conducting magnets and superconducting magnets.

43 PARTICLE ACCELERATORS↗

GKTC ACTIVITIES TO PROVIDE NUCLEAR MATERIAL PHYSICAL PROTECTION, CONTROL AND ACCOUNTING TRAINING FOR 2011-2012

The GKTC was created at the Kyiv Institute of Nuclear Research as a result of collaborative efforts between the United States and Ukraine. The GKTC has been designated by the Ukrainian Government to provide the MPC&A training and methodological assistance to nuclear facilities and nuclear specialists. In 2010 the GKTC has conducted the planned assessment of training needs of Ukrainian MPC&A specialists. The objective of this work is to acquire the detailed information about the number of MPC&A specialists and guard personnel, who in the coming years should receive the further advanced training. As a result of the performed training needs evaluation the GKTC has determined that in the coming years a number of new training courses need to be developed. Some training courses are already in the process of development. Also taking into account the specific of activity on the guarding of nuclear facilities, GKTC has begun to develop the specialized training courses for the guarding unit personnel. The evaluation of needs of training of Ukrainian specialists on the physical protection shows that without the technical base of learning is not possible to satisfy the needs of Ukrainian facilities, in particular, the need for further training of specialists who maintains physical protection technical means, provides vulnerability assessment and testing of technical means. To increase the training effectiveness and create the basis for specialized training courses holding the GKTC is now working on the construction of an Interior (non-classified) Physical Protection Training Site. The objective of this site is to simulate the actual conditions of the nuclear facility PP system including the complex of engineering and technical means that will help the GKTC training course participants to consolidate the knowledge and gain the practical skills in the work with PP system engineering and technical means for more effective performance of their official duties. This paper briefly describes the practical efforts applied to the provision of physical protection specialists advanced training in Ukraine and real results on the way to implement such efforts in 2011-2012.

Romanova, Olena↗

Systems and methods for photovoltaic string protection

A system and method includes a circuit for protecting a photovoltaic string. A bypass switch connects in parallel to the photovoltaic string and a hot spot protection switch connects in series with the photovoltaic string. A first control signal controls opening and closing of the bypass switch and a second control signal controls opening and closing of the hot spot protection switch. Upon detection of a hot spot condition the first control signal closes the bypass switch and after the bypass switch is closed the second control signal opens the hot spot protection switch.

14 SOLAR ENERGY↗

Protection Coordination of an Inverter Generation Based Microgrid for an Unbalanced Distribution System

In this paper we examine the protection issues that must be dealt with, to successfully operate a microgrid when the utility experiences a grid outage. Changes in fault current levels within microgrids under grid-tied and islanded conditions present challenges to developing robust and reliable protection schemes. These schemes must provide an effective response in both grid-connected and islanded mode and the transition between these modes. In this study, a section of an actual residential community located in the western part of the United States (U.S.) was considered as part of the microgrid evaluation. A sizing analysis was conducted to select the appropriate sizes of DER; simulated using DER-CAM analysis. The two DERs considered for the study included solar PV and Battery Energy Storage System (BESS). This paper highlights the protection coordination issues when an existing unbalanced distribution system encompassing a residential subdivision is converted into a microgrid with generation sources with low fault contribution. It further explains the strategy to coordinate protection devices during grid connected and islanded microgrid operating regimes.

Bello, Mobolaji↗

Protective coating compositions and devices

In one aspect of the present invention, a UV-protective coating composition is described. The UV protective coating composition includes an acrylate polymer; and a non-crystallizing UV-absorber composition. The non-crystallizing UV absorber composition includes a dibenzoylresorcinol and at least one triazine compound. The dibenzoylresorcinol is present at a level in the range of from about 10 weight percent to about 25 weight percent, based on the total weight of the coating composition. Also provided is an article that includes the UV protective coating composition, and a method to protect the article.

Pickett, James Edward↗

Protected electrode structures and methods

An electrode structure and its method of manufacture are disclosed. The disclosed electrode structures may be manufactured by depositing a first release layer on a first carrier substrate. A first protective layer may be deposited on a surface of the first release layer and a first electroactive material layer may then be deposited on the first protective layer. The first protective layer may have a low mean peak to valley surface roughness and/or may be thin. In some embodiments, an interface between the first protective layer and the first electroactive material layer has a low mean peak to valley surface roughness.

Mikhaylik, Yuriy V.↗

Target Control and Protection Systems Lessons from SNS Operations

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory has been in operations since 2006 and proposes a project to build a Second Target Station (STS) to effectively double potential scientific output. The SNS target controls operate in a harsh environment which includes high radiation, exposure to gaseous radionuclides, and activated liquid mercury and mercury vapor. These conditions necessitate protective interlocks and credited controls for protection functions to ensure proper response to off-normal conditions. In order to inform the design of target controls for the STS, we have examined lessons learned during SNS operations regarding the design and implementation of the control and protection systems for the first target station (FTS). This paper will examine various aspects of the performance of the target control and protection systems including reliability, maintainability and sustainability given the challenging environment created by 1.4 MW operations. Specific topics include distributed control of various target subsystems, response to loss of power, selection of nuclear grade instrumentation, and applying these lessons to the design for the STS project.

Humphreys, Dana↗

Bit error protection in cache memories

A computing device having a cache memory that is configured in a write-back mode is described. A cache controller in the cache memory acquires, from a record of bit errors that are present in each of a plurality of portions of the cache memory, a number of bit errors in a portion of the cache memory. The cache controller detects a coherency state of data stored in the portion of the cache memory. Based on the coherency state and the number of bit errors, the cache controller selects an error protection from among a plurality of error protections. The cache controller uses the selected error protection to protect the data stored in the portion of the cache memory from errors.

Kalamatianos, John↗

Adaptive Protective Relay Settings – A Vision to the Future

Adaptive relaying utilizes the continuously changing status of the power system as the basis for online adjustment of the power system relay settings. Fundamentally they are protection schemes that adjust settings and/or logic of operations based on the prevailing conditions of the system. These adjustments can include, but are not limited to, the logging of data for post-mortem analysis, communication throughout the system, as well as changing relay parameters. Adaptive relaying considers the fact that the status of a power system can change. These include system configuration changes, load effect, cold load pickup, end-of-line protection, transformer protection, and automatic reclosing. In this research, the author focus on the need for a secure, selective, and reliable system for adaptive overcurrent protection in T&D and Distributed Energy Systems. Various types of adaptive methods are presented and explained along with some pros and cons of each.

Mukherjee, Srijib↗